Home

GE WM7M Installation Guide

image

Contents

1. Verify that supply voltage is correct by comparing it to nameplate If unit is designated as multivolt or multiwatt follow specific instruction Do not remove insulated connectors from wires not needed for required voltage connection Route incoming supply conductors through clips provided and maintain half inch minimum spacing from ballast and reflector These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to GE Lighting Solutions IF SINGLE VOLTAGE All single voltage ballasts are pre wired such that user need only connect the supply conductors IF MULTIVOLT 120 208 240 277 volts Connect the ballast lead with the insulated terminal to the desired voltage terminal as indicated on the ballast terminal nameplate IF MULTIWATT Multiwatt ballasts are available in various combinations of wattage See wiring instructions on wiring tag inside the luminaire LAMPS The Wallmount 175 is designed for High Pressure Sodium Mercury and Metal Halide lamps of 175 watts and less depending on the ballast installed A CAUTION Risk of burn e Allow lamp fixture to cool before handling A WARNING Risk o
2. GE Lighting Solutions GEH 5809 INSTRUCTIONS Wallmount 175 Luminaire READ THOROUGHLY BEFORE INSTALLING A WARNING Risk of electric shock Turn power off before servicing see instructions A WARNING Risk of fire e Use supply wire specified on nameplate MOST DWELLINGS BUILT BEFORE 1985 HAVE SUPPLY WIRE RATED 60C CONSULT A QUALIFIED ELECTRICIAN BEFORE INSTALLING GENERAL This luminaire is designed for outdoor lighting service and should not be used in areas of limited ventilation or in high ambient temperature enclosures Best results will be obtained if installed and maintained according to the following recommendations UNPACKING This luminaire has been properly packed so that no parts should have been damaged during transit Inspect to confirm INSTALLATION CAUTION Unit will fall if not installed properly e Follow installation instructions The refractor door is made with slide off hinges and should be removed during installation and wiring to prevent possible damage and permit better access Customer wiring enters through the center hole in the rear or through the conduit hole located on the top An easy access wiring compartment behind the reflector is provided for electrical connection Knockout holes are provided to permit mounting on vertical surfaces with two or four bolts not provided through the rear of the
3. aire Wallmount 175 A LIRE AVEC SOIN AVANT D INSTALLER DANGER Risque d lectrocution e Mettre hors tension avant d intervenir Suivez les instructions DANGER Risque d inflammation e Utilisez les fils d alimentation sp cifi s sur la plaque d identification AUX USA LA PLUPART DES HABITATIONS B TIES AVANT 1985 ONT UN CABLAGE SECTEUR DE TYPE 60C CONSULTEZ UN ELECTRICIEN PROFESSIONNEL AVANT L INSTALLATION PR SENTATION Ce luminaire est con u pour fournir un clairage l ext rieur et ne doit pas tre utilis dans des zones ventilation limit e ou sous des temp ratures ambiantes lev es Les meilleurs r sultats sont obtenus avec une installation et un entretien conformes aux recommandations qui suivent D BALLAGE Ce luminaire a t emball correctement de fa on ce qu aucune de ses pi ces ne soit endommag e pendant son transport Veuillez proc der une v rification pour le confirmer INSTALLATION A ATTENTION Risque de chute en cas de mauvais montage Suivez les instructions La porte du r fracteur est pourvue de charni res d boitables et doit tre t e pendant installation et c blage pour viter de l endommager et avoir un meilleur acc s Le c blage local arrive par le trou central l arri re ou par l arriv e de conduite situ e sur le dessus Un compartiment de raccordement lect
4. aut pour que son rebord sup rieur s engage dans le cran du bo tier Effectuez tous les raccordements en conformit avec les normes nationales et les ventuels r glements locaux applicables V rifiez que la tension secteur disponible est la bonne en comparant avec l indication de tension sur la plaque d identification Si l appareil est con u pour tre multi tensions ou multi puissances suivez les instructions sp cifiques N enlevez pas les connecteurs isol s des fils non concern s par le raccordement de la tension Faites passer les fils d alimentation d arriv e par les colliers fournis en laissant un espacement de 12 7 mm 1 2 au moins par rapport au ballast et au r flecteur Ces instructions n ont pas pour destination de couvrir tous les d tails ou variantes de l quipement ni de r pondre toutes les ventualit s que vous pourriez rencontrer pendant l installation le fonctionnement ou l entretien Si vous souhaitez des informations compl mentaires ou si vous rencontrez un probl me particulier qui ne soit pas adress de votre point de vue d acheteur le sujet doit tre remont jusqu la soci t GE Lighting Solutions MONO TENSION Tous les ballasts sont pr cdbl s et l utilisateur n a qu relier les fils d alimentation pour la tension pr vue MULTI TENSIONS 120 208 240 277 volts Reliez le fil de ballast avec sa terminaison isol e sur la borne de tension ad quate comme indiqu sur la p
5. f burn e Do not touch operating luminaire Use only lamps specified on nameplate Observe lamp manufacturer s recommendations and restrictions on lamp operation particularly ballast type burning position etc Lamp Tightness Mogul Base Lamp The lamp should be securely inserted to the NEMA EEI specified torque of 35 inch pounds which is best achieved by very firmly tightening to insure application of sufficient torque Tightening must be sufficient to fully depress and load the center contact of the socket Lamp Tightness Medium Base Lamp The lamp should be tightened to a light firmness sufficient to depress the center contact CHECKING OUT THE SYSTEM When the luminaire is ready for operation turn on the power If there is a photoelectric control cover the control window with some black tape or other masking The lamp arc should strike and the lamp should reach full brightness within a few minutes 3 4 minutes for high pressure sodium Remove the photoelectric control masking and this should turn the fixture off if installed during daylight hours TROUBLESHOOTING If the fixture does not operate after installation reread the instructions and perform the following checks 1 Is there proper incoming power to the fixture as specified on the nameplate 2 Is the lamp damaged Replace with new lamp Is lamp seated in socket properly 3 For models with optional photoelectric control a During dayl
6. fixture You can also attach the luminaire to a suitable surface mounted outlet box 3 or 4 octagon or 2x4 rectangular The unit may be attached to the outlet box not provided with two 10 24 screws approxi mately 3 4 long not provided An alternate method of mounting the unit over a surface mounted outlet box is to position the unit over the box and mount on the vertical surface as above with two or four bolts not provided through the rear of the fixture A gasket is provided with the unit to be placed on the back of the housing between the luminaire and the mounting surface If additional sealing is desired caulk the back of the housing with generic non hardening sealer not provided across the top and down both sides For access to the mounting knockouts and wiring compartment remove the reflector by gently pushing down ward on the top of the reflector allowing the lip of the reflec tor to clear the notch in the housing Rotate the reflector forward and remove After installation and wiring is com plete replace the reflector by fully inserting the bottom edge of the reflector into the two slotted tabs in the housing Rotate the reflector back into the housing and gently push down ward on the top of the reflector to allow the top edge to engage the notch in the housing WIRING Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements
7. ight operation does the lamp come on when the photoelectric control window is covered If not retest with a known good lamp If it still does not light replace the control device b During daylight operation does the lamp go out within two minutes after the control window is uncovered If not replace the control device c After having operated correctly in service does the lamp burn continually all day If so replace the control device 4 With high pressure sodium HPS lamps the end of life failure mode is one of cycling The lamp will come on for a short time and then shut off The initial on off period may be as long as an hour or more but will shorten over time to as little as one minute Replacement of the lamp will correct the cycling condition 5 For replacement parts contact a local authorized General Electric Company lighting systems distributor MAINTENANCE AND CLEANING It will occasionally be necessary to clean the optical parts in order to maintain the light level Frequency of cleaning will depend on the dirt level in the area and the minimum light level which is acceptable The reflector should be cleaned with any suitable non abrasive glass cleaning solution soap or detergent and rinsed with clean water The glassware may be cleaned with any conventional glass cleanser NOTE Use of abrasive cleaners will shorten the life of any reflector surface GE Lighting Solutions GEH 5809 INSTRUCTIONS Lumin
8. ip d une commande photo lectrique masquez la fen tre de d tection de cette commande avec une bande noire ou tout autre obturation L arc de la lampe doit s amorcer et elle doit atteindre sa pleine luminosit en quelques minutes 3 4 minutes pour les lampes vapeur de sodium haute pression Enlevez le masquage de la com mande photo lectrique le luminaire doit s teindre si son installation a lieu la lumi re du jour 2 DEPANNAGE Si le luminaire ne fonctionne pas apr s son installation relisez les instructions et faites ces v rifications 1 La tension secteur est elle conforme la tension d alimentation pr conis e sur la plaque d identification 2 La lampe est elle endommag e Remplacez la par une neuve La lampe est elle bien ins r e dans sa douille 3 Sur les mod les commande photo lectrique a la lumi re du jour la lampe s allume t elle quand la fen tre de cette commande est masqu e Sinon refaites l essai avec une autre lampe que vous savez bonne Si elle ne s allume toujours pas remplacez le module de commande photo lectrique b la lumi re du jour la lampe s teint t elle dans les deux minutes apr s le d masquage de la fen tre de commande Si ce n est pas le cas remplacez le module de commande photo lectrique c Apr s avoir fonctionn correctement pendant un certain temps la lampe reste t elle allum e toute la journ e Si c est le cas remplacez le module de commande pho
9. laque du ballast MULTI PUISSANCES Les ballasts multi puissances sont disponibles en diverses combinaisons de wattages Reportez vous aux instructions de c blage sur l tiquette l int rieur du luminaire LAMPES Le Wallmount 175 est con u pour des lampes vapeur de sodium haute pression ou de mercure ou aux halognures m talliques de 175 watts ou moins suivant le ballast install a ATTENTION Risque de brdlure e Laissez le bloc d ampoule refroidir avant d y toucher DANGER e Risque de br lure e Ne touchez pas le luminaire allum utilisez que le type de lampe sp cifi sur la plaque d identification Observez les recommandations et restrictions du fabricant sur le fonctionnement de la lampe en particulier pour le type de ballast la position d utilisation etc Serrage de lampe culot goliath La lampe doit tre ins r e de acon s re avec un couple de serrage NEMA EEI sp cifi 4 4 mkg 35 ivre pouce ce qui est le mieux r alis en serrant fortement la main pour mettre un couple suffisant Le serrage doit compl tement appuyer et charger le contact central de la douille avec le culot de la ampe Serrage de lampe culot moyen La lampe doit tre serr e avec une orce mod r e permettant de faire contact au centre de la douille V RIFICATION DU SYST ME Quand le luminaire est pr t fonctionner mettez le sous tension S il est qu
10. mation provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 35 201578 1E 10 00
11. rique facile d acc s se trouve derri re le r flecteur Des trous enfon ables sont pr vus pour un montage en surface verticale avec deux ou quatre boulons non fournis au travers de l arri re de l appareil Vous pouvez aussi fixer le luminaire sur une bo te de raccordement mont e en surface de taille convenable octogonale de 7 6 ou10 1 mm soit 3 ou 4 ou rectangulaire 5 1x10 2 mm soit 2x4 L appareil se fixe alors avec deux vis non fournies 10 24 d environ 19 mm 3 4 Une autre fa on de le monter est de le positionner sur la bo te de raccordement et de le fixer la surface verticale comme au d but avec deux quatre boulons non fournis qui traversent son arri re Un support est livr avec le luminaire pour s intercaler entre lui et la surface de montage S il y a besoin de plus d tanch it enduisez l arri re du bo tier avec un produit d tanch it g n rique non durcissant non fourni sur les bords haut et bas et les c t s Pour acc der aux trous enfon ables pour le montage et au compartiment de c blage enlevez le r flecteur en poussant doucement son dessus pour que son rebord d passe le cran du bo tier Faites tourner le r flecteur vers l avant et dtez le Une fois intallation et c blage termin s remettez le r flecteur en place en ins rant fond son rebord inf rieur dans les deux pattes rainur es du bo tier Faites le pivoter vers l arri re dans le bo tier et poussez doucement sur son h
12. to lectrique 4 Avec les lampes vapeur de sodium haute pression HPS la manifestation de panne en fin de vie est un cycle d clairage La lampe s allume pendant une dur e limit e et s teint d elle m me Le cycle d allumage extinction qui peut tre de plus d une heure au d but va en se raccourcissant pour arriver tre de l ordre d une minute seulement Le remplacement de la lampe corrige ce probl me 5 Pour les pi ces de rechange contactez un revendeur local des syst mes d clairage de General Electric Company ENTRETIEN ET NETTOYAGE Il sera n cessaire de nettoyer l occasion les parties optiques pour maintenir le niveau lumineux La fr quence de ce nettoyage d pend de l empoussi rage de l environnement et du seuil minimum d clairage tol r Le r flecteur doit tre nettoy avec avec toute solution non abrasive appropri e pour le nettoyage des vitres du savon ou du d tergent puis rinc e l eau claire Les parties en verre peuvent tre nettoy es avec tout nettoyant pour vitres NOTE L utilisation de nettoyants abrasifs diminurait la dur e de vie de la surface du r flecteur GE Lighting Solutions e 1 888 MY GE LED e www gelightingsolutions com 1 888 69 43 533 GE Lighting Solutions is a subsidiary of the General Electric Company Evolve and other trademarks belong to GE Lighting Solutions The GE brand and logo are trademarks of the General Electric Company 2011 GE Lighting Solutions Infor

Download Pdf Manuals

image

Related Search

Related Contents

.... ..ー-害・土王・手持主------..............----  Tract des pique  Blodgett DFG-100 User's Manual  MBS598228 - MyBioSource  FRIBOURGEOIS Mode d`emploi 2.0  ECS Z77H2-A3D (V1.0) motherboard  SoftBank 101SI 取扱説明書  "user manual"  

Copyright © All rights reserved.
Failed to retrieve file