Home
GE SAM Installation Guide
Contents
1. Grasp spring loaded PE control receptacle P and lift up rotate receptacle clockwise until North arrow Q printed on top of receptacle points North Reseat receptacle If this orientation prevents light from reaching control window R rotate arrow to point South Toinstallthe photoelectriccontrol Seeillustration C Insert the PE control S in its proper keyed socket slots on top of fixture making certain that the largest of the three prongs is inserted onto the slot located adjacent to the word North on the socket Press downward and twist clockwise about 1 8 of a turn to secure LLAI ES d P 5 ae LIFT TWIST AND RESEAT ILLUSTRATION B ILLUSTRATION C STEP 4 Installationoflampintosocket CAUTION Risk of burn e Allow lamp fixture to cool before handling Use only lamps specified on nameplate The lamp should now be screwed into socket making sure lamp is firmly seated to insure good electrical contact STEP 5 Installation ofopticalassemblytohood Optical assembly should be handled carefully to prevent damage from surface abrasion or severe impact For Non UL fixtures attach optical assembly to hood by snapping two latches on reflector to ears on hood See illustration D For UL fixtures attach optical assembly to hood by aligning mounting holes in top of reflector with two pe in kaa housing and attach with screws and washers making sure dimple in top of ee reflec
2. e Couper l alimentation avant toute intervention Voir les instructions ATTENTION Le luminaire de type 201 SA a t concu pour de l clairage ext rieur et ne doit pas tre utilis dans des zones ventilation limit e ou dans des enceintes temp rature ambiante lev e CROU RONDELLE CARR E BOULON TRAVERSANT BRAS D EXTENSION N TIRE FONDS 4 Om RQ SUPPORT DE MONTAGE Type 201SA Montage sur conduite Pour luminaires non catalogu s UL TAPE 1 POUR LUMINAIRES NON CATALOGUES UL Installation dubrasdemontagesurlepoteau Le luminaire type 201 SA un par emballage est con u pour tre mont sur un poteau en bois cylindrique voir l illustration ci dessus pour l identification et la localisation des pi ces Le bras de montage doit tre fix en premier sur le poteau Il faut percer un trou de passage pour le boulon de diam tre 16 mm 5 8 au travers du poteau Le boulon traversant de 25 cm 10 doit tre ins r au travers de ce trou avec une rondelle carr e de 5 cm 2 serr e l chement par un crou en bout de tige de boulon La plaque d appui du bras de montage doit tre plac e sur la t te carr e du boulon traversant pour que cette t te soit prise par les deux taquets en retrait de la plaque d appui sur poteau voir l illustration A ILLUSTRATION A L crou doit alors tre serr fond pour que le bras de montage soit bien fix sur le poteau Des tire fo
3. allumera galement en une a deux minutes mais il lui faudra jusqu sept minutes pour atteindre la pleine luminosit Enlever le masquage de la fen tre le luminaire doit automatiquement s teindre GE Lighting Solutions 1 888 MY GE LED e www gelightingsolutions com 1 888 69 43 533 GE Lighting Solutions is a subsidiary of the General Electric Company Evolve and other trademarks belong to GE Lighting Solutions The GE brand and logo are trademarks of the General Electric Company 2011 GE Lighting Solutions Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 35 201578 146 6 06
4. be connected to two incoming black line service leads and white to incoming white neutral Some 240 volt service are two wire and will be furnished with two black leads for operation of both ballast and PE control at 240 volts These two black leads should be connected to two black service leads as outlined above Units with terminal board have terminals plainly marked L for line and N for neutral or L and L for both sides of line in two wire system unit and L L for line and N for neutral in a three wire system unit Always check terminal screws after final tightening to make sure that they are tight STEP 7 Checkingoutthesystem Your luminaire should be ready for operation Make sure lamp and photoelectric control are correctly installed Check PE control to insure it faces North Turn on power Cover PE control window with black tape a glove or some masking object A high pressure sodium lamp should light within one to two minutes It will take three to four minutes for lamp to warm up to full brightness A mercury vapor lamp will also light within one to two minutes but will take five to seven minutes to reach full brightness Remove black tape etc and luminaire should shut off automatically GE Lighting Solutions GEH 5953A INSTRUCTIONS Type 201SA Luminaires catalogu s UL ou non A LIRE ATTENTIVEMENT AVANT D INSTALLER A AVERTISSEMENT Risque d lectrocution
5. secteur en 120 ou 240 volts Les ballasts ne sont pas raccordables et sont pr vus pour tre utilis s uniquement si sp cifi s sur l tiquette V rifier que le secteur disponible est appropri en comparant avec la plaque signal tique Les luminaires pour 120 V sont livr s avec un fil d alimentation blanc et un noir Le fil blanc correspond au neutre et doit tre connect avec le fil d arriv e du neutre du monophas Le fil noir doit tre branch avec la hase du monophas Pour les appareils UL tous les raccordements lectriques doivent tre r alis s en conformit avec la norme lectrique am ricaine et toutes les exigences locales applicables V rifier que toutes les connexions sont bien isol es et que le luminaire et bien reli la terre Tous les raccordements lectriques une fois r alis s doivent tre prot g s l int rieur du bras de montage Installer la fiche l extr mit ouverte du bras et le fixer avec les deux vis fournies Le c blage qui reste doit maintenant tre ins r dans la conduite non fournie et la conduite fix e au raccord qui est install sur le capuchon de connecteur L extr mit oppos e de la conduite doit tre termin e par un second connecteur de conduite qui est reli une bo te de raccordement comme illustr Pour tous les appareils les luminaires en 240 V sont normalement pr vus pour tre aliment s en 3 fils 240 V au pour 240 V sont livr es avec trois fi
6. GE Lighting Solutions GEH 5953A INSTRUCTIONS Type 201SA For Non ULand UL Listed Fixtures READ THOROUGHLY BEFORE INSTALLING A WARNING Risk of electric shock e Turn power off before servicing seeinstructions CAUTION Type 201 SA luminaire is designed for outdoor lighting and should not be used in areas of limited ventilation or in high ambient temperature enclosures EXTENSION ered x LAG BOLTS 4 umm eJ A H MOUNTING BRACKET Type 201SA Conduit Mounting For Non UL Listed Fixtures STEP 1 FOR NON UL LISTED FIXTURES Installationofmountingarmtopole Type 201 SA luminaire unit pack is designed for mounting on a round wood pole See above illustration for identifica tion and location of parts The mounting arm should first be mounted to pole A clearance hole fora 5 8 inch diameter bolt must be drilled through pole The 10 inch through bolt should be inserted through clearance hole and 2 inch square washer and nut screwed loosely onto opposite end of through bolt The pole plate on mounting arm should be placed over square head of through bolt so that square head is engaged by two indented tabs on pole plate See illustration A ILLUSTRATION A Nut should be tightened down so that mounting arm is securely attached to pole Lag bolts should be inserted into outside lower holes of mounting arm pole plate Hammer lag bolts in to within approximately 1 of head then tigh
7. ation delacapuchesurlebrasde montage ATTENTION L appareil peut tomber s il est mal install e Bien suivre les instructions d installation Les fils du capuchon doivent d abord tre pass s au travers de l extr mit du bras de montage pour les amener jusqu l autre extr mit au niveau de l arriv e de conduite d alimentation Pour les appareils non UL il est recommand de former une boucle d gouttement la sortie du bras de montage comme indiqu sur le sch ma ci dessus Ces instructions n ont pas pour destination de couvrir tous les d tails ou variantes de l quipement ni de r pondre toutes les ventualit s que vous pourriez rencontrer pendant l installation le fonctionnement ou l entretien Si vous souhaitez des informations compl mentaires ou si vous rencontrez un probl me particulier qui ne soit pas adress de votre point de vue d acheteur le sujet doit tre remont jusqu la soci t GE Lighting Solutions Pour tous les appareils v rifier que l ouverture de l trier pour bras de montage de l adaptateur d emboitement est assez large pour que le bras puisse y tre ins r Sinon desserrer les deux boulons de collier jusqu ce que son ouverture soit assez grande L adaptateur d emboitement est alors ins r sur l extr mit ext rieure du bras de montage jusqu ce que le bras bute sur l arr t de tuyau l extr mit int rieur de l adaptateur environ 6 35 cm Une fois que le b
8. eads exit mounting arm as indicated in above drawing These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to GE Lighting Solutions For all fixtures check to see if opening of mounting arm clamp in slipfitter is large enough to allow mounting arm to be inserted If not loosen two clamp bolts until opening is large enough The slipfitter is then inserted over outboard end of mounting arm mounting arm being inserted until it comes to rest at pipe stop on inboard end of slipfitter approx 2 Y inches Once mounting arm is fully inserted level hood with mounting arm clamp relatively loose by placing outboard end of mounting arm on appropriate step of leveling pipe stop then tighten two clamp bolts securely taking care not to disturb position of hood torque should be approx 10 15 foot pounds NOTE The mounting arm clamp is factory installed for use with a 1 inch pipe If a 2 inch pipe is being used it will be necessary to flip the mounting arm clamp over For UL fixtures install first weatherproof conduit connector not provided into the conduit connection cap STEP 3 Toorientthephotoelectricreceptacle See illustration B
9. ls deux noirs et un blanc Les deux fils noirs doivent tre connect s avec les deux fils noirs d arriv e et le blanc avec le neutre de l arriv e secteur Certains appareils pour 240 V sont en deux fils et les lumi naires sont livr s avec deux fils noirs pour le fonctionnement la fois du ballast et de la commande photo lectrique en 240 volts Ces deux fils noirs sont raccorder aux deux fils noirs d arriv e secteur comme pr c demment Les appareils avec bornier comportent des bornes clairement identifi es avec L pour la phase et N pour le neutre ou L gt et L pour les deux c t s de la ligne dans les unit s deux fils et L gt pour phase et N pour neutre dans les unit s a trois fils V rifier toujours les vis du bornier apr s le raccordement pour s assurer qu elles sont bien serr es TAPE 7 V rification fonctionnelle du syst me Votre luminaire devrait tre pr t fonctionner V rifier encore que l ampoule et la commande photo lectrique sont bien install es V rifier que la commande photo lectrique est bien dirig e vers le Nord Envoyer l alimentation secteur Recouvrir la fen tre de commande photo lectrique avec de la bande noire un gant o un objet pour la masquer Une ampoule au sodium haute pression doit s allumer en une ou deux minutes Il faut ensuite trois quatre minutes pour que l ampoule atteigne sa pleine luminosit Une ampoule vapeur de mercure s
10. nds peuvent tre ins r s dans les trous inf rieurs ext rieurs de la plaque d appui du bras de montage Les enfoncer au marteau jusqu environ 2 5 cm de leur t te puis finir de les enfoncer avec une cl FICHE DE CONTACT RACCORD DE CONDUITE NON FOURNI CON NON FOURNIE RACCORD DE CONDUIT NON FOURNI BOITE DE RACCORDEMENT NON FOURNIE ETAPE 1 TYPE 201 SA A MONTAGE SUR CONDUITE POUR LUMINAIRES CATALOGUES UL Installationdubrasdemontagesurlepoteau REMARQUE Cet appareil est con u pour tre branch par un conduit sur une bo te de raccordement tanche convenablement install et reli la terre non fourni Tous les raccords de conduite le conduit et la bo te de raccordement non fournis doivent tre catalogu s UL pour emplacements humides Fixer le support de montage en deux parties sur le bras d extension en les verrouillant ensemble et en les tenant par le boulon de carrosserie 74 20 et l crou 6 pans 44 20 fournis Le support de montage doit tre serr en laissant environ 2 5 cm de bras d extension d passer du bas du support de montage comme illustr Placer l ensemble de bras d extension sur la surface de montage voulue et marquer l emplacement des quatre trous de fixation Enlever le bras et percer ces quatre trous Monter en place le bras d extension en utilisant les tire fonds t te 6 pans fournis Les serrer fond avant de poursuivre TAPE 2 Install
11. ras est bien ins r mettre au niveau voulu le capuchon avec le collier du bras de montage relativement l che en pla ant l extr mit ext rieure du bras de montage sur le cran appropri de la but e de r glage de niveau puis bien serrer les deux boulons de collier en prenant garde de na pas perturber la position de la capuche Le couple de serrage doit tre d environ 13 55 18 36 N m 10 15 livres par pied NOTE L attache du bras de support est mont e d usine pour l usage avec un conduit de 1 pouces Si un conduit de 2 pouces est utilis il sera n cessaire de renverser l attache Pour les appareils UL installer d abord le raccord tanche de conduite non fournis dans le chapeau de raccordement de conduite TAPE 3 Orientation du receveur photo lectrique Voir l illustration B Prendre le receveur de commande photo lectrique ressort P et le lever le tourner dans le sens des aiguilles d une montrer jusqu ce que la fl che indiquant le Nord Q grav e North sur le dessus pointe vers le Nord Laisser revenir en place le receveur Si l orientation emp che la lumi re d atteindre la fen tre de commande R faire tourner la fl che pour pointer vers le Sud Installation de la commande photo lectrique Voir l illustration C Ins rer la commande photo lectrique S correctement dans ses fentes de douille d trompeur sur le dessus du receveur en s assurant que la plus grosse des trois broches es
12. t ins r e dans la fente situ e c t du mot North sur la douille Presser pour enfoncer et tourner dans le sens des aiguilles d une montre de 1 8 de tour pour verrouiller S R LEVER TOURNER ET REPLACER ILLUSTRATION B ETAPE 4 Installation de l ampoule dans la douille ATTENTION Risque de brulure e Laisser refroidir ampoule et luminaire avant de manipuler ILLUSTRATION C N utiliser que le type d ampoules mentionn sur la plaque signal tique L ampoule doit maintenant tre viss e dans sa douille en tant bien mise en place pour assurer un bon contact lectrique TAPE 5 Installation de l ensemble optique sur la capuche L ensemble optique doit tre manipul avec pr cautions pour viter de l endommager par abrasion de sa surface ou par des chocs importants Pour les appareils non UL fixer l ensemble optique la capuche en enfichant deux taquets du r flecteur dans les ouvertures de la capuche voir l illustration D Pour les appareils UL fixer l ensemble optique la capuche en alignant les trous de montage en haut du r flecteur avec deux trous dans l enveloppe de l appareil et utilisant des vis et rondelles en v rifiant que l encoche en haut du r flecteur est orient e vers l extr mit de montage de l unit A ILLUSTRATION D TAPE 6 Cablage du circuit lectrique du luminaire Diverses r f rences catalogue sont fournies pour une utilisation sur
13. ten down with wrench CONNECTION PLUG CONDUIT CONNECTOR NOT PROVIDED CONDUIT NOT PROVIDED CONDUIT CONNECTOR 2 NOT PROVIDED JUNCTION BOX NOT PROVIDED STEP 1 TYPE 201 SA CONDUIT MOUNTING FOR UL LISTED FIXTURES Installationofmountingarmtopole NOTE This fixture is intended to be conduit con nected to a properly installed and properly grounded weatherproof junction box not provided All conduit connectors conduit and junction boxes not pro vided should be UL listed suitable for wet locations Attach two piece mounting brackets to extension arm by interlocking bracket and securing with 1 4 20 carriage bolt and 1 4 20 hex nut provided Mounting bracket should be secure leaving approximately one inch of extension arm protruding from bottom of bracket as shown Place extension arm assembly onto desired mounting surface and mark four hole locations required mounting Remove arm assembly and drill four marked locations for ease of mounting Mount extension arm assembly using hex head lag bolts provided Tighten bolts securely before proceeding STEP 2 Installationofhoodtomountingarm A CAUTION Unit will fall if not installed properly e Follow installation instructions The leads from hood should first be inserted through outboard end of the mounting arm and brought out through inboard end adjacent to the pole plate For Non UL fixtures it is recommended a drip loop be formed where l
14. tor is oriented to mounting end of ti unit TN ILLUSTRATION D STEP 6 Wiring luminaire to electrical circuit Different catalog numbers are furnished for use on120 volt or 240 volt service Ballasts are not reconnectable and are intended for use only as specified on label Verify that supply voltage is correct by comparing it to nameplate 120 volt luminaires are furnished with one black and one white wiring lead White lead is neutral and should be connected to white neutral service lead Black line lead should be connected to black line service lead For UL fixtures all wiring connections should be made in accordance with National Electric Code and any applicable local code requirements Ensure that all connections are properly insulated and that luminaire is grounded correctly All wiring connections should be made and then concealed in mounting arm Install plug in open end of arm and secure with 2 screws provided The remaining wire should now be inserted into conduit not provided and the conduit secured to connector which is installed in connector cap The opposite end of conduit should be terminated by second LL connector which is then joined to junction box as shown For all fixtures 240 volt luminaires are normally intended for use on three wire electrical service 240 volts to ballast and 120 volts to PE control 240 volt units are furnished with three wiring leads two black and one white Two black leads should