Home
GE ZV421 User's Manual
Contents
1. Model ZV54I Actual Chimney Length at Duct Duct Cover Ceiling Hood Installation Height Cover Height 30 31 32 33 34 Kit 10 4 20 for ZV421 10 3 Order 24 for ZV541 10 2 ZX54DC10 a 101 Use Long 10 Support 9 11 and 9 10 Duct Cover 30 Min and 36 Max Order ZX54DC10 Use Short 36 Support to and Countertop r Duct Cover ACCESSORIES ZX42DC10 Optional Accessory for ZV421 ZX54DC10 Optional Accessory for ZV54I ae Accessories for ceiling heights of 8 6 to 10 4 Support Includes telescoping support frames and duct and covers Duct Cover Advance Planning DUCT FITTINGS Use this chart to compute maximum permissable lengths for duct runs to outdoors Note Do not exceed maximum permissable equivalent lengths Maximum recommended duct length for these hoods 150 equivalent feet Flexible ducting Flexible metal ducting is not recommended If it must be used all the equivalent feet values in the table should be doubled The flexible metal duct should be straight and smooth and extended as much as possible Semi rigid flexible duct is preferred when flexible duct must be used
2. Do NOT use flexible plastic ducting Note Any home ventilation system such as a ventilation hood may interrupt the proper flow of combustion air and exhaust required by fireplaces gas furnaces gas water heaters and other naturally vented systems To minimize the chance of interruption of such naturally vented systems follow the heating equipment manufacturer s guidelines and safety standards such as those published by NFPA and ASHRAE Hoods Are Equipped For 10 Round Duct Hoods are supplied with a 10 round transition A locally supplied transition is required for other sizes Note Outlet on top of hood is 8 1 8 x 8 Actual length of straight duct plus duct fitting equivalent Equivalent length of duct pieces are based on actual tests conducted by GE Evaluation Engineering and reflect requirements for good venting performance with any ventilation hood Duct Piece Equivalent Quantity Total Length Used Length Round 1 ft per foot length straight 1 ft per foot length 3 1 4 x 24 straight 90 elbow 15 ft 45 elbow 1 4 x 12 or 1 4 x 24 elbow 1 4 x 24 elbow 1 4 x 24 90 flat elbow 10 round to 3 1 4 x 24 transition 3 1 4 x 24 to 10 round transition 10 round to 3 1 4 x 24 transition 90 elbow 3 1 4 x 24 to 10 round transition 90 elbow Round wall cap with damper 3 1 4 x 24 wall
3. s are required to support the weight of the hood 12 3 4 42 Hood 17 54 Hood Install Cross Framing Symmetrically About Duct Cooktop Centerline EXAMPLE A e The hood should extend beyond the front and rear edge of the cooking appliance e The duct in the ceiling must be centered over the cooktop Ceiling Hood Ducting Centerline Align With Center of eee Cnogiop s Countertop 54 Hood Side View Cooktop e Arrange cross framing in the ceiling to suit the existing structure e Your ceiling joists will be like one of the following examples TEE 2x4 Cross Framing Align duct to center of Cooktop A Cooktop Outline Top View Ceiling Joists Parallel to Front of Hood Installation Instructions STEP 1 CONSTRUCT CEILING SUPPORT CONTINUED EXAMPLE B 12 3 4 42 Hood 17 54 Hood a l Install Cross __ Framing Spaci Symmetrically About re Duct Cooktop Centerline 2x4 Cross Align duct Cooktop to center of Outline Cooktop Top View Ceiling Joists Run Perpendicular to Front of Hood EXAMPLE C 12 3 4 42 Hood 17 54 Hood Install Cross Framing Symmetrically About Duct Cooktop Centerline 2x4 Cross Framing 16 Joist Spacing Align duct to center of Cooktop Cooktop Outline Top View Ceiling Joists at Angle with Front of
4. nouse wiring is not 2 wire with a ground wire a ground must be provided by the installer When house wiring is aluminum be sure to use UL approved anti oxidant compound and aluminum to copper connectors ATTENTION Si le c blage de la maison n est pas du type a deux fils avec un fil de terre l installateur doit fournir un circuit de terre Quand les fils de la maison sont en aluminium il prendre soin d utiliser de la pate antioxidation approuv e par UL et des connecteurs pour l aluminium cuivre STEP 9 INSTALL THE MOTOR Outlet e l Attachment Spring Slot Clip Attachment Screw and Washer e Screw F d Attachment Spring Slot Clip e From the inside of the hood slip motor into the attachment slot on the left e Rotate motor upwards until it snaps into the spring clip on the right e Secure the motor to the hood with the machine screw and lock washer Screw is marked with red paint e Plug blower cable into the connector on the blower e Install strain relief onto the knockout of the junction box e Insert house wiring through strain relief and tighten e Use wire nuts to connect incoming ground to green white to white and black to black e Push wires into junction box and replace cover Be sure wires are not pinched IMPORTANT Connector ends are designed to mate only one way Match flat and round conne
5. Through The Ceiling 12 Installation Instructions STEP 2 MOUNT TEMPLATE e Select the template for your hood size e Align the template with the marks on the ceiling and tape in place Be sure the template is oriented correctly with the front of the hood e Use a plumb to check to be sure the mounting holes will provide parallel alignment with the countertop below e Center punch all hole locations e Drill pilot holes in the 4 screw locations Use a 3 16 bit and drill approximately 1 1 2 deep e Drive 4 Hex head wood screws Screws A into the center of the ceiling joists and cross framing Leave a 1 4 gap to allow the screw head to engage the keyhole slots on the support frames e Cut the 10 1 2 duct opening through the sheet rock STEP 3 SIZE AND INSTALL DUCTWORK e Measure from house duct flange to bottom of support frame Subtract 4 3 8 for clearance to the bottom of the support frame e Cut the 10 duct length to size e Secure duct to house ducting with sheet metal screws e Seal all connections with duct tape e Attach the duct collar loosely about 1 from the bottom of the duct using Screws B 13 Installation Instructions STEP 4 T Install Safety Screw on Each Side 5 Screws E Installation Hei Install supplied support frame OR telescoping accessory frame e Hang the supplied s
6. cap with damper Round roof cap OOyoVAAPP P IL AOS i Round roof vent Total Duct Run Installation Preparation TOOLS AND MATERIALS REQUIRED NOT SUPPLIED 7 16 Pivoting hex socket with 4 and 6 extensions Duct tape Wire cutter stripper Pencil and tape measure A Spirit level CO Flashlight Saber saw Y or Sawsall Step ladder S Ys Carpenter s square Pliers Metal Snips REMOVE THE PACKAGING e Remove the parts packages and packing materials e Lift the hood out of the box IMPORTANT tit the hood by grasping the outside edges of the exhaust opening on the top Shipping Carton e Place the hood on a protective surface to prevent scratches and damage to the stainless steel finish Electric or battery operated drill and 3 16 bits Phillips and Flat Blade Screwdriver bits Phillips and flat blade screwdrivers Key Hole Saw j Wire nuts 10 round metal duct length to suit installation D Strain relief for junction cover 120V 60Hz 15 or 20 Amp 2 wire with ground Properly A grounded branch circuit e Carefully lay the hood on its side A support frame is secured to the inside top of the hood Remove the attachment screws at the outside top Discard screws e Grasp the support frame inside the hood with both hands and carefully rotate out of the opening Be careful not to scratch the
7. hood T e The hood motor is shipped secured to the skid with 4 screws Locate and remove 2 screws on each side of the motor Discard the shipping skid and screws Installation Preparation PARTS PROVIDED Locate the parts packed with the hood Transition with Damper Support frame for 8 ft ceiling with 4 large pan head screws installed on the bottom corners Implement rods with standoffs 2 piece decorative duct cover Duct collar 2 Grease trays 3 with 54 hood 2 Filters 3 with 54 hood Decorative top cover HARDWARE PACKAGE ACCESSORY PACKAGE Locate and check Check accessory package contents Screws Select the taller set for 9 6 to 10 4 ceilings shown actual size Select the shorter set for 8 6 to 9 6 ceilings Discard unused set Installation Instructions STEP 1 CONSTRUCT CEILING SUPPORT Plan the Location of the Hood and Ductwork e Use a plumb bob to check the location The countertop cooktop below the hood must be centered with the hood Ceiling Hood Ducting Centerline Align With Center of _ Cooktop Cooktop lt S Countertop 42 Hood Side View Ceiling Support Structure e At the hood location install 2 x 4 cross framing between ceiling joists as shown 2x4
8. rattles and vibration You should notice an audible difference at each speed setting Clean the hood surfaces and all filters See the Owner s Manual for cleaning instructions They should be free of construction debris such as sawduct Check for foreign material in transition Check that blower screen is not damaged or pushed into the blower impeller The damper should move freely Listen for opening and closing while turning the unit on and off Check that the damper is not damaged does not vibrate and that damper bumper pads are in place Order a damper replacement assembly if needed Check that ductwork is 10 round If duct type is not rigid and less than 10 round inform the consumer that performance will be reduced Check Lighting Function Check that power cable is plugged into the junction box on top of the hood Turn halogen lamps to each setting Note change in brightness at different settings Check that each lamp bezel is secure Turn to the right to tighten Order replacement lamp bezel and socket assemblies if needed 19 Note While performing installations described in this book safety glasses or goggles should be worn For Monogram local service in your area call 1 800 444 1845 Note Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specif
9. read carefully WARNING FOR PERSONAL SAFETY THIS APPLIANCE MUST BE PROPERLY GROUNDED ATTENTION rour ves MA RAISONS DE S CURIT CET APPAREIL DOIT ETRE CORRECTEMENT MIS A LA TERRE Remove house fuse or open circuit breaker before beginning installation Do not use an extension cord or adapter plug with this appliance Follow National electrical codes or prevailing local codes and ordinances Electrical Supply This vent hood must be supplied with 120V 60Hz and connected to an individual properly grounded branch circuit and protected by a 15 or 20 amp circuit breaker or time delay fuse e Wiring must be 2 wire with ground e If the electrical supply does not meet the above requirements call a licensed electrician before proceeding e Route house wiring in the ceiling as close to the installation location as possible Allow additional length from ceiling joists to reach the junction box on the bottom of the hood support frame e Connect the wiring to the house wiring in accordance with local codes Grounding Instructions The grounding conductor must be connected to a ground metal permanent wiring system or an equipment grounding terminal or lead on the hood WARNING tre improper connection of equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded ADVERTIS
10. Duct cleaning instructions Cover Screw E on Each Side Screws D e Install the supplied 2 piece duct cover over the support frame if using supplied frame Snap ends together e Secure duct covers to support frame with 2 Screws D e For a more finished appearance a top cover is supplied and should be installed whenever the top of the hood is visible TIP Place pieces of tape over ends 4 of the cover to prevent scatching the duct cover i To Remove tape before installing amp screws e Engage tabs into slots on each side at the top of the hood The covers should lay flat in the impression on top of the hood Top Cover p Screws C Install Screws Front and Back e Install 2 Screws C to secure the cover to the hood at the front and back 18 Installation Instructions STEP 15 INSTALLATION CHECKLIST Check Blower Safety Screw Ensure that blower safety screw is securely tightened See page 16 Step 9 If screw is missing order replacement parts bag Check appearance and installation Use a spirit level to check that the hood is level Review installation instructions to determine source of problem Top covers if used should lay flat in the recess on top of the hood Make sure side tabs are engaged in slots and the cover is secured with two screws Check Operating Sound and Proper Air Flow Turn blower to each speed setting and listen for
11. Hood Installation Instructions STEP 1 CONSTRUCT CEILING SUPPORT CONTINUED e Secure each 2 x 4 block with at least four 4 10 wood screws 3 long not supplied Use 8 wood screws total for the two supports e The cross framing must be accurately aligned to assure correct positioning of the hood e The cross framing must be level in all directions Check with a spirit level and adjust if necessary IMPORTANT The ceiling structure must be capable of supporting the weight of the hood approximately 300 pounds and any inadvertent user contact loads The hood support frame will be supported by the 2 x 4 cross framing Ductwork e Use the shortest and straightest duct route possible For satisfactory performance duct run should not exceed 150 feet equivalent length for any duct configuration e Refer to Duct Fittings chart to compute the maximum permissible length for duct runs to the outdoors e This vent hood must use 10 round rigid duct e Install the house ductwork to run horizontally between ceiling joists or straight up through the roof Finish the Ceiling e Finish the ceiling surface Be sure to mark location of the ceiling joists and cross framing Check to be sure the ceiling is level use shims if necessary 2x 4 Min Cross Framing Ceiling Joist 42 Hood Height Adjustment i Screw Holes Ceiling Joint eagles a Duct A Vent Straight Up
12. Installation Instructions If you have questions call 800 GE CARES or visit our website at www monogram com Island Vent Hoods Models ZV421 ZV54I Monogram Installation Instructions Read these instructions completely and carefully e IMPO RTANT Save these instructions for local inspector s use e IMPORTANT observe all governing codes and ordinances e Note to Installer Be sure to leave these instructions with the Consumer e Note to Consumer Keep these instructions for future reference e Skill Level Installation of this vent hood requires basic mechanical and electrical skills Completion time 1 to 3 hours Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the Warranty CAUTION Due to the weight and size of these vent hoods and to reduce the risk of personal injury or damage to the product THREE PEOPLE ARE REQUIRED FOR PROPER INSTALLATION BEFORE YOU BEGIN PRUDENCE cause du poids et des dimensions du ces hottes et pour r duire les risques de blessures ou de dommages du produit IL FAUT TROIS PERSONNES POUR FAIRE UNE INSTALLATION CORRECTE WARNING To reduce the risk of fire or electrical shock do not use this range hood with any external solid state speed control device Any such alteration from original factory wiring could result in damage to the unit and or create an electrical safety h
13. SEMENT Le mauvais branchement du fil de mise a la terre peut causer un choc lectrique En cas de doute consulter un lectricien qualifi ou un technicien pour d terminer si l appareil est a la terre Advance Planning INSTALLATION HEIGHT REQUIREMENTS e These vent hoods must be installed 30 min and 36 max Actual et eae oaeee sat ae above the cooking surface regardless of the ceiling sean rt rtd Ki 2 height Therefore installation height of the hood depends on the exact ceiling height of the kitchen Order e Accessories are available for ceiling heights 8 6 and up ZX42DC10 to 10 4 Use Long at i Support Example Hood installation height with 8 ft ceilings i and 8 ft Ceiling 8 ft Ceiling Duct Cover 9 5 Supplied Supplied Duct Duct i Order ver Cover Co k ZX42DC10 Use Short i Support i and ZV421 ZV54I Duct Cover e Both models are shipped with a support frame and duct cover for 7 11 to 8 5 ceilings e f the ceiling height is 7 11 the installation height above the cooking surface will be 30 e f the ceiling height is 8 5 the hood installation height will be 36 iiss DETERMINE INSTALLATION HEIGHT Supplied 1 Measure the exact ceiling height aa 2 Review the chart to determine the range of hood i Duct Cover installation heights that can be accomplished with or without an accessory kit
14. azard ADVERTISSEMENT Pour r duire le risque d incendie ou de choc lectrique il ne faut pas utiliser cette hotte avec un r gulateur de vitesse lectronique externe Toute modification de ce type du branchement d usine peute endommager l appareil ou cr er un risque de choc lectrique TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARNING to rebuce tHe RISK OF FIRE ELECTRICAL SHOCK OR INJURY OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer B Before servicing or cleaning unit switch power off at the service panel and lock service panel to prevent power from being switched on accidentally If the service panel cannot be locked fasten a tag or prominent warning label to the panel ADVERTISSEMENT POUR REDUIRE LE RISQUE D INCENDIE DE CHOC ELECTRIQUE OU DE BLESSURES IL FAUT OBSERVER LES REGLES SUIVANTES A Utiliser cet appareil uniquement de la mani re pr vue par le fabricant En cas de question consulter le fabricant B Avant toute intervention ou nettoyage couper l alimentation lectrique au disjoncteur et verrouiller le panneau du disjoncteur pour viter la mise sous tension accidentelle S il n est pas possible de verrouiller le panneau du disconcteur attacher un placard ou une tiquette tr s visible au panneau e For general ventilating use only Do not use to exhaust hazardous or explosive materials
15. ctors as shown Junction Box e Plug cable at the top of the hood into the junction box connector Route cable so it won t be pinched or damaged when the duct cover is lowered 16 Installation Instructions STEP 10 SLIDE DUCT COVER STEP 12 INSTALL RODS DOWN e Use a flat blade screwdriver to install stand offs into SKIP THIS STEP IF USING THE SUPPLIED DUCT the bottom of the hood COVER e Align implement rod to stand offs with the screw hole towards the inside of the hood Secure the rod to the e Hold the duct cover in place and remove the stand offs with the supplied Allen wrench temporary stop screw Return the screw to the e Follow the same procedure on the opposite side storage location for future use e Slide the lower duct cover down onto the hood Stand offs Into Hood tee Use Allen STEP 11 INSTALL FILTERS ee Secure Rod to Stand offs e Place filter drip trays into the rear of the hood 4 e Insert the filter into the upper opening and drop into the trays To remove the filters grasp the knobs and push the filter up and lift out 17 Installation Instructions STEP 13 INSTALL SUPPLIED DUCT STEP 14 FINALIZE INSTALLATION COVER AND TOP COVER e Check all lamps to assure tightness in sockets e Turn power on at the circuit breaker e Refer to the Owner s Manual for operating and Install
16. e length for duct runs to the outdoors e Use rigid metal ductwork only e Install a roof cap with damper at the exterior opening Order the cap and any transitions needed in advance Ceiling Framing for Adequate Support e These vent hoods are heavy Adequate structural support must be provided The ceiling structure must be capable of supporting the weight of the hood and any inadvertent user contact loads approximately 300 pounds The hood support frame will be supported by 2 x 4 cross framing Accessory Frames and Duct Covers e All models are shipped with a support frame and duct covers for ceilings heights of 7 11 to 8 5 e Optional accessories include telescoping support frames and duct covers to reach 8 6 and up to 10 4 ceiling heights e Optional accessories must be ordered with the hood and be on site before final framing and wall finishing Mounting the hood without a support frame The distance between the cooking surface and the bottom of the hood must be 30 to 36 In situations where the ceiling is low the hoods may be secured directly to the ceiling without the supplied frame Use the bottom of the supplied support frame as a template to locate the mounting holes in the top of the hood Use shims on the ceiling joists or cross framing in the mounting hole locations This will allow the mounting screws to engage the recessed keyhole slots in the top of the hood See Step 2 POWER SUPPLY IMPORTANT Please
17. ications are subject to change without notice Monogram Pub No 49 80209 1 Dwg No 164D4290P361 09 03 JR GE Consumer Products General Electric Company Louisville KY 40225 2003 General Electric Company
18. mager l enceinte du conduit La vis de but e emp che l enceinte inf rieure du conduit de descendre pendant l installation Secure house wiring e Route house wiring through the ceiling and pull a length to reach the hood junction box approximately 6 below the support Tape to the right side of the support frame IMPORTANT Again check to be sure the support is level in both directions There is no way to level the hood after the hood is secured to the frame Installation Instructions STEP 5 INSTALL DUCT TRANSITION WITH DAMPER Bumper Pads Duct Transition Attachment Screws F IMPORTANT Remove shipping tape from damper and check that damper moves freely e Place the transition piece over the hood exhaust and secure with 4 Screws C provided e Use duct tape to seal the connection Check to be sure the damper moves freely 15 STEP 6 INSTALL HOOD Note THREE PEOPLE ARE REQUIRED TO COMPLETE THIS INSTALLATION Attachment Keyholes e Back out the hanging screws on the bottom of the support frame to a 1 4 gap e Lift the hood up to the support frame Carefully align the hood keyhole to the screws on the support frame Slide the hood to engage the keyhole slots e Tighten the screws Install 2 Safety Screws Slide Duct Collar Down lto Cover Gap Installation Instructions STEP 8 CONNECT ELECTRICAL Verify that power is turned off at the source WARNING
19. or vapors e Structural framing installation work and electrical wiring must be done by qualified person s In accordance with all applicable codes and standards including fire rated construction e Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities e Local codes vary Installation electrical connections and grounding must comply with applicable codes In the absence of local codes the vent should be installed in accordance with National Electrical Code ANSI NFPA 70 1990 or latest edition CAUTIONS to reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages PRUDENCE Il faut prendre soin d installer un conduit vers l ext rieur pour r duire le risque d incendie et pouvoir vacuer l air correctement Il ne faut pas vacuer l air correctement Il ne faut pas vacuer l air dans l espace entre les parois d un mur un plafond ou un grenier un espace sanitaire ou un garage Design Information CONTENTS Design Information Produc
20. supplied support frame and duct cover Order ZX42DC10 for ceiling heights of 8 6 to 104 ZV54I 5 for ceiling heights 7 11 to 8 5 using the supplied support frame and duct cover Order ZX54DC10 for ceiling heights of 8 6 to 104 These accessories include telescoping support frames and decorative covers Order the accessory for your model at the same time as the vent hood and have on site before installation begins PRODUCT CLEARANCES 36 Y These vent hoods must be installed 30 min to 36 max above the cooking surface Exact installation height is determined by ceiling height The cooking surface should be at least 36 above the floor IMPORTANT Clearances may vary due to type of cooking product and local codes Check with local inspectors to be sure standard is applicable e When installing these Island Hoods above a Monogram Professional Range or Cooktop installation clearance must be at least 30 Advance Planning ADVANCE PLANNING Ductwork Planning e These vent hoods are equipped for 10 round ductwork e Determine the exact location of the vent hood e Plan the route for venting exhaust to the outdoors e Use the shortest and straightest duct route possible For satisfactory performance duct run should not exceed 150 ft equivalent length for any duct configurations e Refer to Duct Fittings chart to compute the maximum permissibl
21. t Dimensions Duct Cover Accessories Product Clearances Advance Planning Ductwork Planning Ceiling Framing for Support Accessory Frames and Duct Covers Power Supply Installation Height Duct Fittings Installation Preparation Tools and Materials Required Remove the Packaging Parts Hardware Accessory Packages 42 HOOD DIMENSIONS Model ZV42I Supplied duct covers dimensions 16 W x 12 D x 9 H These vent hoods are supplied with a support frame and decorative duct cover for ceiling heights of 7 11 to 8 5 The hood installation height is determined by the ceiling height Accessories are available to reach ceiling heights from 8 6 to 104 Installation Instructions Step 1 Construct Ceiling Support Step 2 Mount Template Step 3 Size and Install Ductwork Step 4 Install Support Frame and Duct Covers Step 5 Install Duct Transition and Damper Step 6 Install Hood to Support Step 7 Connect Duct Step 8 Connect Electrical Step 9 Install the Motor Step 10 Slide Duct Cover down Step 11 Install Filters Step 12 Install Rods Step 13 Install Supplied Duct Cover Top Cover Step 14 Finalize Installation Step 15 Installation Checklist 54 HOOD DIMENSIONS Model ZV54I Supplied duct covers dimensions 20 1 4 W x 12 D x 5 H Design Information DUCT COVER ACCESSORIES A Heig to Ceili 20 For ZV42I 24 For VMI ZV 421 9 for ceiling heights 7 11 to 8 5 using the
22. upport frame or telescoping accessory frame to the ceiling joists and cross framing on the 4 hex head screws by engaging the keyhole slots on the frame e Check to be sure the support frame is level vertically and horizontally e Tighten the hex head screws securely e Install safety screws Screws E on each side of the frame Adjust telescoping accessory frame to length e Remove the 8 frame adjustment screws Adjust the lower support up or down to the pre determined length Reinstall and securely tighten the 8 adjustment screws e Slide the top inner accessory duct cover up and over the frame Secure the duct cover to the frame as shown using Screws D e Locate and remove the safety stop screw Slide bottom duct cover up and over the top duct cover Align bottom duct screw hole to the hole in the frame Hold the duct cover in place while installing screw 14 INSTALL ACCESSORY OR SUPPLIED SUPPORT AND DUCT COV Install Small Pan Head Screws on Each Side Pali Top Duct Cover Lyt Bottom Duct Cover F Screws D Install Stop Screw i ase Screw Storage Location A CAUTION tre stop screw must be installed Failure to do so could result in personal injury or damage to the duct cover The stop screw will prevent the lower duct from sliding down while completing the installation A PRUDENCE Il faut mettre en place la vis de but e afin d viter des blessures ou d endom
Download Pdf Manuals
Related Search
Related Contents
Montageanleitung Automatic-Antenne AUTA 6000 KE Industrial Computing Solutions Applied Panel Display DESCRIPCIÓN: Revestimiento liso Marley Aquatower Installation, Operation and Maintenance User Manuale - Cambridge Audio English Franke FSI 912 GR INSTRUCTION MANUAL Microwave Oven MEDIDORES DE TIERRA - Chauvin Arnoux Group Epson Perfection® V500 Photo - Epson America, Inc. Copyright © All rights reserved.
Failed to retrieve file