GE HLUF & VLUF Installation Guide
Contents
1. 24 750 in 629mm WIRING ACCESS 3 298 in 84mm BOLT PATTERN tI 6 gt 2 875 in 73mm F o o 4 HOLES Y 4 375 in 0 436 in DIA Paran 11mm DIA TRUNNION MOUNTED UNITS Mounted directly ona flat surface Mounting adapters are available for installa tion on poles crossarms pipes etc The trunnion bracket has a clearance hole for a 3 4 inch bolt used for attach ment to such mountings The 0 562 inch holes on either side permit additional anchoring where required Tighten side trunnion bolts to 18 22 foot pounds PIPE MOUNTED UNITS The slipfitter can be mounted on 1 7 8 inch O D through 2 3 8 inch O D or 2 7 8 inch O D through 3 inch O D pipes Three set screws are used to clamp the floodlight securely to the pipe Tighten set screws to 18 22 foot pounds WALL MOUNTED UNITS The wall mounting plate is provided with four 4 0 438 inch clearance holes spaced 4 375 H x2 875 V inches for mounting AIMING Slightly loosen bolt A two on trunnion one on slipfitter tilt luminaire to desired position and retighten bolts Both trunnions and slipfitters have vertical degree scales which permit setting the floodlight at a selected These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular prob
2. Electric Company Evolve and other trademarks belong to GE Lighting Solutions The GE brand and logo are trademarks of the General Electric Company 2011 GE Lighting Solutions Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 35 201578 65 1 00
3. GE Lighting Solutions HLU READ THOROUGHLY BEFORE INSTALLING Trunnion Mounted Standard SCREW B 19 500 in 495 mm PE CONTROL AIMING SIGHT Aa WHEN REQUIRED m 17 375 in 441mm iY BOLT A 750 in 578mm 24 938 in 633mm 31 000 in i 787mm 8 812in 224mm i 2 500 in 64mm J H 8 750 in 222mm 44 S in 511mm 0 562 in 14mm DIA 2 HOLES A4 0 875 in 22mm DIA SET SCREWS 3 REQUIRED A WARNING Risk of electric shock e Turn power off before servicing see instructions GENERAL This luminaire is designed for outdoor lighting applica tions and should not be used in areas of limited ventilation or in high ambient temperature enclosures Best results will be obtained if installed and maintained according to the following recommendations UNPACKING This luminaire has been properly packed so that no parts should have been damaged during transit Inspect to confirm MOUNTING CAUTION Unit will fall if not installed properly e Follow installation instructions This floodlight is provided with either trunnion mount ing pipe mounting or wall mounting means Slipfitter Mounted Options K or S GEH 3851C INSTRUCTIONS VLU Powerflood Floodlight Wall Mounted Option V PE CONTROL 7 C WHEN REQUIRED
4. ballast terminal nameplate IF MULTIWATT Multiwatt ballasts are available in various combi nations of wattage See wiring instructions on wiring tag inside the luminaire TRUNNION MOUNTED LUMINAIRES Three conductor No 14 cable with 90 C minimum insulation is recommended for making electrical connections to these units Open the floodlight by loosening two screws B and pulling the door forward Remove the insulation shield from the reflector to expose the wiring entrance and terminal board Loosen screws in pressure plate insert cable through grommet and retighten screws Notice that grommet fits cable of approximately 9 16 inch diameter Grommet and pressure plate form a weatherproof seal and strain relief To maintain this seal screws in pressure plate must be retightened whenever seal is disturbed Connect line lead to first 1 terminal board position and neutral lead to last 3 position and connect ground lead to the terminal with the green lead attached Before closing luminaire be sure insulation shield is properly attached to the reflector SLIPFITTER MOUNTED AND WALL MOUNTED UNITS Splice supply leads to three leads inside wiring box Splice line lead to black lead neutral lead to white lead and ground lead to green lead which is electrically connected to floodlight housing LAMPS Use only lamps specified on nameplate Observe lamp manufacturer s recommendations and restrictions on lamp opera
5. lems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to GE Lighting Solutions angle and facilitate repositioning to the original setting after having moved the floodlight for servicing Also a sight has been cast into the top of the housing as an aid in aiming the unit during daylight hours PHOTOELECTRIC CONTROL Photoelectric control receptacle if present should be oriented before control is installed Loosen the two holding screws and rotate receptacle until North is directed as near as possible to true north Tighten holding screws and install control WIRING Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements Verify that supply voltage is correct by comparing it to nameplate If unit is designated as multivolt or multiwatt follow specific instruction Connect ground lead to the green lead green ground screw on housing or terminal block provided Do not remove insulated connectors from wires not needed for required voltage connection When changing voltage on reconnectable units move only the lead with the insulated connector IF SINGLE VOLTAGE All single voltage ballasts are pre wired such that user need only connect the supply conductors IF MULTIVOLT 120 208 240 277 volts Connect the ballast lead with the insulated termi nal to the desired voltage terminal as indicated on the
6. tion particularly ballast type burning position etc The VLU is designed for high pressure soduim HPS Deluxe White mercury and metal halide lamps of 400 watts and less depending upon the ballast installed The HLU is designed for HPS lamps only Lamp Tightness Mogul Base Lamp The lamp should be securely inserted to the NEMA EEI specified torque of 35 inch pounds which is best achieved by very firmly tightening to insure application of sufficient torque Tightening must be sufficient to fully depress and load the center contact of the socket MAINTENANCE A CAUTION Risk of burn e Allow lamp fixture to cool before handling A WARNING Risk of burn e Do not touch operating luminaire This unit has a ballast tray which can be removed for easy replacement of the ballast ignitor or capacitor To remove the tray disconnect the supply leads from the terminal board separate the disconnect to the lamp and photoelectric control loosen the screws at the top of the ballast tray and slide the tray to the left so that the tray can be pulled free over the keyhole slots Reverse this procedure for installation The ALGLAS finished reflector and door glass may be cleaned with any suitable non abrasive glass cleaning solution soap or detergent and rinsed with clean water GE Lighting Solutions e 1 888 MY GE LED e www gelightingsolutions com 1 888 69 43 533 GE Lighting Solutions is a subsidiary of the General
Download Pdf Manuals
Related Search
Related Contents
CATALOGUE 2015 EXTINCTION AUTOMATIQUE Diazinon 50WSP Insecticide RP- 69 7.8.1 Dulco_turb_C, 1, de_DE 728 EX - STARLIGH Importador y Distribuidor mayorista de sistemas SITES 2006 User Guide for the International Database KIFT – Autonomous Vehicle - Department of Electrical Engineering installation ESCUELA POLITÉCNICA NACIONAL FACULTAD DE INGENIERÍA 334267C, ProMix PD2K Electronic Proportioner Copyright © All rights reserved.