GE GFPS & GFPT Installation Guide
Contents
1. 5 201578 E3 3 04
2. EMA EEI specified torque of 35 inch pounds which is best achieved by very firmly tightening to insure applica tion of sufficient torque Tightening must be sufficient to fully depress and load the center contact of the socket MAINTENANCE A CAUTION Risk of burn e Allow lamp fixture to cool before handling A WARNING Risk of burn e Do not touch operating luminaire Periodic cleaning on the outside of the door glass will ensure operation at maximum optical efficiency The glass and reflector if needed should be cleaned with non abrasive soap cleaner or detergent solutions rinsed with cold water and wiped dry NOTE Door may be removed by opening approximately 190 lifting up slightly and sliding to the right The light output is also dependent on the age of the lamp In applications where the light level is critical it may be desirable to replace lamps before they burn out The lamp manufacturer can provide data showing how the lamp light output decreases with use GE Lighting Solutions e 1 888 MY GE LED e www gelightingsolutions com 1 886 69 43 53 3 GE Lighting Solutions is a subsidiary of the General Electric Company Evolve and other trademarks belong to GE Lighting Solutions The GE brand and logo are trademarks of the General Electric Company 2011 GE Lighting Solutions Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 3
3. GE Lighting Solutions READ THOROUGHLY BEFORE INSTALLING 8 038 in 204mm 23 625 in 600mm 20 531 in 521mm 15 453 in R en 29 582 in 751mm 23 250 in R 591mm R Py l Y i 2 000in heres aan 20001 O 875 in DIA a i 22mm DIA l 1 875 in 48mm SET SCREWS 3 750 in 95mm a ee i A20 MAIN HOUSING 7 eacl a iF RUBBER BUSHING CABLE ENTRANCE PROTECTIVE INSULATION SHIELD Figure 1 Risk of electric shock e Turn power off before servicing see instructions GENERAL This luminaire is designed for outdoor lighting applications and should not be used in areas of limited ventilation or in high ambient temperature enclosures Best results will be obtained if installed and maintained according to the following recommen dations UNPACKING This luminaire has been properly packed so that no parts should have been damaged during transit Inspect to confirm MOUNTING A CAUTION Unit will fall if not installed properly e Follow installation instructions WIRING ACCESS 3 298 in 84mm 3 REQUIRED 2 875 in 73mm 1 oO De 7 Fier GEH 3902H INSTRUCTIONS PF 400 Powerflood Floodlight Glarefighter Powerflood and Turnpike Luminaire BOLT PATTERN This floodlight is provided with either trunnion mounting pipe mounting or wall mounting NOTE The unit may be mounted to point from straight up to
4. ameplate IF MULTIWATT Multiwatt ballasts are available in various combinations of wattage See wiring instructions on wiring tag inside the luminaire TRUNNION MOUNTED UNITS NOTE Cable strain relief and sealing are provided by the compression plate and rubber bushing supplied for 9 16 inch O D cable Three conductor AWG No 14 cable is recommended Refer to Figure 1 1 Opentheglassdoor NOTE Door may be removed by opening approximately 190 lifting up slightly and sliding to the right 2 Remove protective insulation shield NOTE On units provided with the power tray option disconnect the two plugs on the top of tray Loosen screws and remove tray 3 Insert cable through compression plate and rubber bushing and secure by tightening screw 4 Makeelectrical connections 5 Reposition protective insulation shield If power tray connect both plugs on top of tray after securing the tray 6 Closeandsecuredoor PIPE AND WALL MOUNTED UNITS Open wiring compart ment cover located on the mounting bracket Make electrical connections and close wiring compartment cover NOTE For multivolt units refer to Ballast Connections on Multivolt Units LAMPS Use only lamps specified on nameplate Observe lamp manufacturer s recommendations and restrictions on lamp operation particularly ballast type burning position etc Lamp Tightness Mogul Base Lamp The lamp should be securely inserted to the N
5. ept with three jam nuts and set screws Tightened to 55 65 foot pounds 3 WALL MOUNTED UNITS The wall mounting plate is provided with four 4 0 438 inch clearance holes spaced 4 375 H x2 875 V inches for mounting AIMING _ FRONT OF SIGHT Y TARGET Up REAR OF SIGHT Figure 2 Located on top of the luminaire above the door locking screw is a sight track optical sight for point aiming Align the front and rear sights so that they have equal space showing on either side of the groove and the target centered in the groove Sighting isnotperformed onthe Turnpike luminaire WIRING Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements Verify that supply voltage is correct by comparing it to nameplate If unit is designated as multivolt or multiwatt follow specific instruction Connect ground lead to the green lead green ground screw on housing or terminal block provided Do not remove insulated connectors from wires not needed for required voltage connection When changing voltage on reconnectable units move only the lead with the insulated connector IF SINGLE VOLTAGE All single voltage ballasts are pre wired such that user need only connect the supply conductors IF MULTIVOLT 120 208 240 277 volts Connect the ballast lead with the insulated terminal to the desired voltage terminal as indicated on the ballast terminal n
6. straight down but in no case may the ballast be located above the optical To mount from overhead structures use the top trunnion option NOTE For aimed up application remove two screws from rear bottom corners of back housing and reinstall them in front housing rear bottom corners TRUNNION MOUNTED UNITS Mounted directly on a flat surface Mounting adapters are available for installation on poles cross arms pipes etc The trunnion bracket has a clearance hole for a 3 4 inch bolt used for attachment to such mountings The 3 8 inch holes on either side permit additional anchoring where required Tighten side trunnion bolts to 50 55 foot pounds A NORMAL PIPE MOUNTED UNITS 2G The slipfitter can be mounted on 1 7 8 inch O D through 2 3 8 inch O D or 2 7 8 inch O D through 3 inch O D pipes Three set screws are used to clamp the floodlight securely to the pipe Tighten set screws to 18 22 foot pounds These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to GE Lighting Solutions B SPECIAL PIPE MOUNTED UNITS 3G For bridge overpass applications custom factory modification required Same as above exc