Home

GE DEH-211 User's Manual

image

Contents

1. 4 Fromthe Host Name Wizard Finished dialog box select Add AR Names to display the AR Name Wizard Host Name dialog box below AR Name Wizard Host Name 5 Enter the Host Name of the AR Name being created then choose Next 6 You may skip dialog boxes referring to Seletors by using the Next button until the AR Name Wizard AR Name dialog box appears CIMPLICITY PMCS Read This Book First Using MMS Servers with PMCS e 63 AR Name Wizard AR Name 7 Complete the AR Name configuration by entering an AR Name entering a Comment optional and selecting TCP IP Transport Choose Next to complete the configuration 8 When the Finished dialog box appears select Finished then Finished again to complete and close the wizard 64 e Using MMS Servers with PMCS CIMPLICITY PMCS Read This Book First This page left blank intentionally CIMPLICITY PMCS Read This Book First Using MMS Servers with PMCS e 65 Index A N alarm 4 NetBuilder 48 AX S4 MMS Server 59 Network Builder 48 D O DDE Server 50 option modules 4 E P Ethernet 4 9 16 17 45 47 PEGASYS event 4 nodes 49 Performance 4 F S Fanuc 4 First Steps 8 Servers DDE 50 I T Interface Toolkit 5 9 43 47 TCP IP 4 9 10 16 47 Technical Support 3 8 11 M Terminology 8 minimum system requirements 3 MMS Server 59 W Modbus Monitor Proxy 35 Modbus RTU 4 9 45 waveform capture 4 Windows NT 4 10 14 16 19
2. 66 e Index CIMPLICITY PMCS Read This Book First GE Industrial Systems General Electric Company 41 Woodford Ave Plainville CT 06062 DEH 211 R06 1000 2001 General Electric Company
3. generic topics and that CIMPLICITY Wizards are installed in the generic HMI application WARNING PMCS 5 1 and PMCS 5 1b Modbus DDE Server users only Upgrading from PMCS 5 1 to PMCS 6 9 may cause the Modbus version of the DDE Server to lose its port configuration You may need to reconfigure your communications ports from the PMCS DDE Server after upgrading The Ethernet version of the DDE Server is not affected PMCS 5 0 users Port configuration is lost when a PMCS 5 0 configuration file is converted to a PMCS 5 1b configuration file You will need to reconfigure your communications ports from the PMCS DDE Server Refer to GEH 6510 for instructions Also any generic topics you may have configured at the PMCS DDE Server will be lost and you will need to re configure these generic topics 1 Close any open applications and insert the PMCS 6 9 CD into the CD ROM drive 2 From Start menu select Run and enter X setup where X is the appropriate CD ROM drive designation 3 Read the general information and disclaimers shown then click Next 4 Enter your name your company name and the serial number located on the PMCS CD jewel case then click Next If you make an error in the serial number the installation routine prompts you for a correct PMCS serial number 5 Choose either PMCS PMCS with EPM 7700 Components or Custom installation PMCS or PMCS with EPM 7700 Components installation will reinstall all components of the appr
4. vo Carn gan nadie acosss bo iha Lario ol POMER LEADER dessces and even bo thed party devices or priami With PICS postal snaivicsl bois you cn pakun advanced posset uadit ande monitor energy consumption even manage fonds Ie all readable though scphilicied grsphics and s highly m re rinli Fra Acinic Please Call 1 585 GES SERV Powered hy Thes Tris quies on F bius 25 2001 CLICENSE Los 30 Day Trial You have the option to Trial PMCS for 30 days through the 30 Day Trial selection on this screen All functionality of PMCS is available to trial users and all configurations made for the software will be maintained from one use to the next A single trial is registered to each PC and may not be uninstalled and re installed for another trial Licensing via the Web Choose the Web License option if you have a working internet connection on your PMCS computer This option will automatically connect you to General Electric Industrial Systems eLicense distribution system Once connected an automated process will retrieve your unique PMCS eLicense key Selecting the Web License option from the License Option brings you to the Web License Screen This screen requires you to enter your eLicense Order ID This information is contained on the Order Confirmation Sheet that accompanied your PMCS software or it can be obtained from your Purchase Confirmation e mail Enter the Order ID and click on Get License to initiate the W
5. 12 e Getting Started CIMPLICITY PMCS Read This Book First This page left blank intentionally CIMPLICITY PMCS Read This Book First Getting Started e 13 Installing the Software Computer Preparation 14 e Installing the Software PMCS must be installed on a PC running Windows NT Workstation 4 0 This host PC must be dedicated to the PMCS system Performance and data integrity cannot be predicted unless the PC is configured solely for the purpose of running PMCS The Windows NT System control panel offers a Performance tab that allows you to boost performance for the foreground application For PMCS must be changed to No Performance Boost for Foreground Application default is Maximum as shown below System Properties i2 x Statup Shutdown Hardware Profiles User Profiles General Performance Environment Application Performance Select the performance boost for the foreground application Boost None Maximum Virtual Memory Total paging file size for all disk volumes 12 MB Change Cancel Apply The Virtual Memory setting may be left at the Windows NT defaults Make sure your system meets these requirements before proceeding with the remaining installation steps PMCS will not run correctly unless these requirements are satisfied Installing CIMPLICITY If CIMPLICITY HMI was provided with your PMCS software you must install it before proceeding If your computer already
6. CIMPLICITY HMI Server Development allows you to create new projects and can also function as a runtime system CIMPLICITY HMI Server Runtime CIMPLICITY HMI Server Runtime systems do not support project configuration They may be used as runtime systems only CIMPLICITY HMI Viewer Runtime CIMPLICITY HMI Viewer Runtime connects to Servers for viewing data and controlling actions Commnet A GE Industrial Systems standard for device communications that specifies the communication protocol and the communication network Communication network A physical standard for wiring and interconnection of communicating devices A communication network standard usually includes specifications of voltages maximum cable run lengths shielding termination and CIMPLICITY PMCS Read This Book First cable requirements RS485 and Ethernet are examples of communication network standards Communication protocol A language or convention used for reliable transmission and reception of binary data A communication protocol is often independent of the physical method or network used for transmission Modbus RTU and TCP IP are examples of communication protocol standards DDE Server A software application that typically runs in the background gathering information from the network and providing the information in DDE format for use by one or more applications The PMCS DDE Server is included in the PMCS Network amp Device Configurator and comes in versions o
7. CIMPLICITY PMCS Read This Book First Installing the Software e 17 18 Installing the Software Installing Additional Software Install any additional software such as Microsoft Excel or COMTRADE file browsers for analyzing waveform files at this point in the procedure Follow the instruction procedures provided by the manufacturer Installing the EPM Software Components The EPM 7700 EPM 7600 and EPM 7500 Meters require additional software to operate with PMCS client software such as the Event Logger Waveform Capture Module or CIMPLICITY Wizards This is because the EPM 7700 EPM 7600 and EPM 7500 are not compatible with the standard PMCS DDE Server Instead a separate DDE Server called the 7700 Gateway Server must be installed along with a pair of helper applications the Communications Server and the ION_Link Server The Communications Server processes all communications between the Gateway Server and or the ION_Link and the Ethernet based EPM 7700 EPM 7600 and EPM 7500 meters The EPM 7700 software may be selected during the standard PMCS installation routine If you are not using any EPM devices in your PMCS setup you do not need to install the EPM options during PMCS installation The EPM software components do require some special configuration beyond that required for other PMCS components Refer to the section titled EPM Device Special Considerations for details after running the installation routine described in this
8. Concentrator A POWER LEADER device used to connect eight commnet networks to an RS485 Modbus RTU network The Concentrator provides full compatibility between the PMCS software and the extensive line of POWER LEADER devices with commnet communications as well as simple expansion of a RS485 Modbus RTU network to up to 247 devices Modbus RTU An industry standard nonproprietary communications protocol typically used in medium speed networks up to 38 4 kpbs on RS485 NetBEUIT A network protocol usually used in small department size local area networks of 1 to 200 clients NetDDE A version of Dynamic Data Exchange DDE that allows communications between applications running on different PCs over network connections NT Service A designated piece of software which runs in the background of Windows NT and can be set to automatically start when the machine is booted up For example the PMCS DDE Server can be set to operate as a Windows NT Service rather than a manually launched application Another advantage of NT Services is that they are persistent across multiple user logins and logouts that is PMCS DDE CIMPLICITY PMCS Read This Book First Getting Started e 9 Server when operating as a Windows NT Service will not shut down when a user logs off ODBC Open Database Connectivity An inter application communication protocol required for certain PMCS client applications to share data Automatically installed and configured as part
9. Explorer is not included as part of PMCS You may obtain the latest version of Internet Explorer by downloading it from www microsoft com 34 e Installing the Software CIMPLICITY PMCS Read This Book First 15 After completing the selected PMCS installation the installation program checks the host PC for an older version of the POWER LEADER Modbus Monitor Proxy software If the installer locates the Proxy software it prompts you to update the Proxy to the PCMS 6 x compatible version before finishing the PMCS installation routine If your system does not use POWER LEADER Modbus Monitor devices or does not have the Monitor Proxy software installed the PMCS installer will skip this step Information Q 16 At this point the installation program copies the appropriate files to your hard drive 17 After the Setup program finishes installing the PMCS components you have selected you will be prompted to install the Adobe Acrobat Reader software If you do not have Acrobat Reader 3 0 or later installed on your PC you may wish to install Acrobat Reader at this time The PMCS CD ROM includes a full complement of technical documentation in Acrobat PDF format which may be viewed with the Acrobat Reader program The documentation is located in the TechDocs directory of the CD ROM Install Adobe Acrobat Q 18 After the installation of Acrobat Reader you will be prompted to install Waveform Analyst software Install Wavefor
10. Server RAS and configure it by enabling NetBEUI if using NetBEUI or if TCP IP is used assign two or more IP addresses starting at xxx xxx xxx 254 and working down Set RAS to start automatically and set access to entire network if available EPM Device Special Considerations e 51 Configuring the EPM Device Network The PMCS installation routine described earlier in this manual creates initial workstation and software node entries in the EPM 7700 network configuration file After EPM 7700 software components are installed the next step is to add Ethernet sites and devices to the PMCS power monitoring network using Network Builder software Running Network Builder Network Builder software presents your EPM power monitoring network graphically showing the installed components in a hierarchical tree Network Builder allows you to edit the Network Configuration file the file that identifies every node in the EPM power monitoring network The first step is to run Network Builder from the Start Menu Programs gt Power Measurement Ltd gt Utilities gt Network Builder The following figure shows how Network Builder displays a system comprised of the basic EPM software components a single EPM 7700 meter a Primary Node and a Stationless Secondary node also called a view node 8 netconfig dat PEGASYS Network Builder E3 File View Item Help Workstation the network name of the Primary Node computer runnin
11. also been provided by the Web Store when you purchased the product Eledronic License Distribution 3 Click the Unlicense button r by VTCyberPak Order ID Unlicense Start Over Proxy enabled The screen will request the eLicense Order ID to be entered CIMPLICITY PMCS Read This Book First A screen will appear to indicate that you have successfully un eLicensed and you may now take the eLicense Order ID for use on another PMCS installation PMCS Unlicense Successful BBE c Success Sf a 3 PMCS Testing has been successfully unlicensed from this m computer and the license has been returned to the license e server a 3 UR ns c To get the license again on this machine or on another 2 f computer run PMCS click the Web License button and La enter ORDER ID in the dialog as the Order ID 2 B 1 a a E J 2 J J by ViCyberPak Please note that you can not retrieve an eLicense for re use through the unlicense process past 3 years of initial Licensing Uninstalling PMCS All PMCS software is provided with an uninstall utility to fully remove PMCS components from your system Uninstalling PMCS will permanently delete any configuration information NOTE The Uninstaller may not delete some files such as error logs system logs and configuration records which are created after the PMCS installation is complete Since these files are not p
12. components are located on the PMCS CD ROM jewel case If you make an error in the serial number the installation routine will prompt you for a correct PMCS serial number When you have completed the registration info click Next User Information x Please enter your name the name of the company for whom you work and the product serial number Name E your name Company E your company name Serial E your serial number lt Back Next gt Cancel 38 e Installing the Software CIMPLICITY PMCS Read This Book First 4 At the Choose Destination Location dialog specify a drive on which to install PMCS Default is C Click Next to continue Choose Destination Drive x Setup will install PMCS on the following drive After selecting an appropriate drive letter click Next Back Cancel 5 Now PQ Analyst setup Dialog box appears Click OK button to continue the PQ Analyst installation PQ Analyst SETUP Welcome to PQ Analyst SETUP This application will install PQ Analyst and its associated components onto your computer If you have an earlier version of PQ Analyst already installed it will be upgraded for you to the latest version To exit SETUP without installing or upgrading this component press Cancel Otherwise press OK to proceed with SETUP Cancel CIMPLICITY PMCS Read This Book First Installing the Software e 39 40 e Installing the Software When all th
13. section CIMPLICITY PMCS Read This Book First Installing the PMCS software Once you have set up Windows NT and any third party software if appropriate you are ready to install the PMCS software PMCS should be installed last after all other software installations are completed Your PMCS software is provided on a CD ROM The diagram below depicts the relationship of the Host PC and any optional Viewer Workstations in your system Follow the specific instructions below for software installation on Host PCs and Viewer Workstations PMCS Network s eLicensing PMCS software General Electric Industrial Systems has added security technology that requires your PMCS software to be licensed in order to run A separate license is required for each computer that will receive PMCS Each eLicense Order ID that is sent with your order corresponds to one license You license your software as part of the automated PMCS installation process When you launch the installation process the first screen that will appear will be your eLicense Option screen see below This screen allows you to either trial or fully license your PMCS software CIMPLICITY PMCS Read This Book First Installing the Software e 19 20 e Installing the Software PHCS Poser Haracement Conso Sister cotter ii He eanHreuns Solve package Pat Lurk a cdeskldop compoler into a run vaida ba eckig aed conici Fach possn aie gud a leche of a Lh
14. 4 e EPM Device Special Considerations CIMPLICITY PMCS Read This Book First Adding an Ethernet Site An Ethernet site defines the network connection between the devices and the Workstation s You add Ethernet sites to Workstations then add devices to the sites To add a new Ethernet site right click a Workstation name and choose Insert Ethernet site from the pop up menu attach it to the current Workstation Click OK to continue 26 netconfig dat PEGASYS Network Builder File View ltem Help mme xlxlm Diagnostic OK Station cc Gateway site Modem site Serial site Cancel Software node Hel Workstation nep Attach to PRIMARY Y An Add Ethernet Site dialog box shown below appears PRIMARY Add Ethernet Site x General Advanced Name PRIMARY Site1 Transmit Delay 100 milliseconds IV Startup Connected Time Synchronization v Enabled for 3xxx devices Interval 500 seconds v Enabled for 7xxx devices Interval fse00 seconds v Enabled for 3720 devices Interval 3600 seconds Use Defaults Set the following communications parameters for the site e Enter the Transmit delay setting in milliseconds This setting determines the level of traffic on the network If the PMCS system is the sole user of the network set this value to 5 or less to maximize performance Increase the transmit delay in situations where the network is shared with ot
15. 9 Motor Management Relay 30D261A8 000 SR 489 Generator Management Relay 1 41 565 Feeder Management Relay VE2 71 735 Feeder Relay 25D152D1 000 SR745 Transformer Management Relay 2 50 SR750 Feeder Management Relay 4 0 SR760 Feeder Management Relay 3 60 POWER LEADER Modbus Concentrator Main Firmware 2 2 Segment Firmware 2 12 POWER LEADER Modbus Monitor 20 GE Fanuc MicroPLC Programmable Logic Controller n a ALPS Advanced Line Protection S ystem V0004 00AA15 LPS Line Protection System V0004 00AA15 DFP 100 Digital Feeder Relay 44 DFP 200 Digital Feeder Relay 2 01 EPM 7300 Meter 1 33 EPM7500 Meter 2 05 EPM7600 Meter 2 01 EPM7700 Meter 2 0 Schweitzer Engineering Laboratories SEL 251 Distribution Relay R406 Schweitzer Engineering Laboratories SEL 321 Phase and Ground Distance Relay R500 Directional Overcurrent Relay and Fault Locator Schweitzer Engineering Laboratories SEL 351 Directional Overcurrent R elay R103 Reclosing Relay and Fault Locator Schweitzer Engineering Laboratories S EL 587 Current Differential Relay R503 System Monitor SM 3 Voltage Regulator 0309B Universal Relay 2 42 CIMPLICITY PMCS Read This Book First Device Firmware Revision Supported Motor Manager II 4 02 CIMPLICITY PMCS Read This Book First Introduction e 7 Getting Started First Steps 8 e Getting Started If you are already familiar with PMCS simply review the system requiremen
16. Confirm that the installation settings are correct then click Next The installation program copies the appropriate files to your hard drive Selected Components x You have selected the following PMCS 6 5 components for installation Press Next to proceed with the installation or Back to change selections Current Settings Waveform Capture Client Waveform Server CIMPLICITY Wizards Target Directory E GE_PMCS Program Folder M gt Cancel If you have selected the EPM 7700 System Components either manually when performing a Custom install or automatically when PMCS with EPM 7700 Components install is selected the installer will check your system for a copy of Microsoft Internet Explorer version 3 02 or higher This is because the EPM 7700 software components use html format help files which require Internet Explorer to view If Internet Explorer is not found the following dialog box appears Information x a suitable version of Microsoft Internet Explorer was not found on this computer You will not be able to use EPM7700 component html help files until Internet Explorer version 3 02 version 4 0 recommended is installed on your system If you wish to view the EPM 7700 software help files you should separately install Microsoft Internet Explorer version 3 02 or higher To take advantage of all available help system features Internet Explorer version 4 0 or higher is required Internet
17. Hogmoam a a Woxox wG onam e fan m Peppe nnam a ao m ofce Breaker View Node You should configure View Nodes after you have configured and tested the Host PC to ensure all functions are operating View Nodes require a copy of the network architecture list used above Refer to GEH 6510 Network and Device Configurator for complete configuration instructions CIMPLICITY PMCS Read This Book First Configuration Procedure Follow the procedure below to efficiently configure your system and minimize your time to startup Host PC Configuration 1 Configure the DDE Server Your Host PC will likely have several versions of the DDE Server installed RS485 Modbus TCP IP Modbus TCP IP Encapsulated Modbus and Ethernet TCP IP Configure only the server appropriate for your PMCS network interface GE32MODB GE32MTCP GE32GTWY or GE32ENET See GEH 6510 Network and Device Configurator for complete details EPM 7700 EPM 7600 and EPM 7500 users only all others proceed to step 3 Configure the Communications Server and GE 7700 Gateway Server If you installed the EPM software options and you are going to use EPM 7700 EPM 7600 or EPM 7500 devices in your PMCS network you will need to configure both the Communications Server and the GE 7700 Gateway Server For Comm Server configuration instructions refer to EPM Software Components Configuration later in this guide For GE 7700 Gateway Server configuration inst
18. IEDs but will be used to access data from other network workstations choose Stationless For more details on EPM 7700 network configuration refer to the EPM Device Special Considerations section later in this manual or to DEH 40035 the GE 7700 Gateway User s Guide Select EPM7700 view node type 28 e Installing the Software CIMPLICITY PMCS Read This Book First 10 If you did not select PMCS with EPM 7700 Components in the Setup Type dialog box Step 7 or if you selected Primary Node Installation in Step 8 skip this step and proceed to Step 11 If you selected Secondary Node installation in Step 9 the following dialog box appears prompting you for the name of the computer on which the Primary Node is installed Primary Node Selection PRIMARY NODE CIMPLICITY PMCS Read This Book First Installing the Software e 29 11 Select the Program Folder for PMCS installation It is recommended that the default Program Folder be chosen Click Next to continue Select Program Folder GE PMCS Administrative Tools Common Microsoft Reference Startup 30 e Installing the Software CIMPLICITY PMCS Read This Book First 12 If you chose the PMCS installation you may be presented with one or more DDE Server selections depending upon the PMCS catalog number you entered in the User Information screen Select only the DDE communications servers that you will be using in your system S
19. Measurement 7700 ION e Type a name in the Group box or choose a Group from the list by default the Group will be the name of the workstation e Enter a name for the meter or accept the default The meter name must begin with a letter e Enter the IP address for the meter e Enter the IP Service Port number socket for the meter For a 7700 7600 and 7500 ION this number is 7700 for a 3720 ACM 3721 Saving and Exiting Once you have added all of your sites and devices to the network tree click the Save button or choose Save from the File menu and exit Network Builder You have now configured your EPM 7700 EPM 7600 and EPM 7500 meters to operate with the PMCS and you should be able to access EPM 7700 EPM 7600 and EPM 7700 metering data from PMCS client applications CIMPLICITY PMCS Read This Book First EPM Device Special Considerations e 57 This page left blank intentionally 58 e EPM Device Special Considerations CIMPLICITY PMCS Read This Book First Using MMS Servers with PMCS What is an MMS Server PMCS is an extremely flexible system which supports generic DDE Servers One such server is the SISCO AX S4 MMS Server MMS stands for Manfacturing Message Specification AX S4 MMS Access for MMS is an easy to use tool that provides real time data integration for Windows applications PMCS applications can access data from MMS servers as well as the PMCS DDE Server The MMS Server should only be used with PMCS
20. PC This information is used throughout the configuration process and you should archive it for any future maintenance of your system For RS485 PMCS network interfaces you need to list all devices in the power management network including Modbus Concentrators with associated device types Modbus RTU addresses and COM ports Assign names of less than 20 characters no spaces to these devices For example in a simple system with four devices and one Modbus Concentrator you may have a table similar to the following COM port Modbus RTU Address Device Type Device Topic Name MODCONC 3720 PLEPH Mfg Meter ifs Breaker MUS Wi Rely For an Ethernet PMCS network interface Ethernet Gateway you must list all devices in the power management network including the device types and Modbus RTU addresses You need to know the appropriate Ethernet Gateway IP address and COM port 1 4 to which each device is connected Assign names of less than 20 characters no spaces to these devices For example in a simple system with 10 devices you may have a table similar to the following this system uses one Ethernet Gateway and three Modbus Concentrators CIMPLICITY PMCS Read This Book First Configuring the Software e 45 46 e Configuring the Software Ethernet Gateway COM Modbus RTU IP Address port Address Device Type Device Topic Name onam 2 Je ren om Hogmoam 2 m Pim omen onam gt Jo nor Feederi Rely
21. PM 7600 and EPM 7500 meters are compatible with PMCS and its client applications Waveform Capture custom wizards etc and EPM 7700 EPM 7600 and EPM 7500 meters may co exist on the same Ethernet as other PMCS network segments the EPM 7700 EPM 7600 and EPM 7500 use a slightly different metaphor than a straight PMCS network An EPM device power monitoring network is comprised of a number of nodes that are connected to the PMCS workstation through Ethernet links Nodes in the power monitoring network are IEDs such as the EPM 7700 meter power meters are also referred to meters or devices IEDs may be distributed across one or more networks as required to service the particular application CIMPLICITY PMCS Read This Book First EPM Device Special Considerations e 49 EPM Software Components There are four major components of the EPM software The Network Builder ION Designer Communications Server and ION_LINK DDE Server each interact to support the EPM 7700 EPM 7600 and EPM 7500 Meters When you selected the PMCS with EPM 7700 Components selection during the PMCS installation routine these software components were installed automatically The four components and their functions are described below Network Builder Building the Network Configuration File The Network Builder presents a graphical view of the EPM 7700 EPM 7600 and EPM 7500 devices in your network allowing you to easily add remove or configure sites s
22. POWER LEADER TM PMCS 6 9 Read This Book F irst Installation Guide DEH 211 GE Power Management Control System 6 9 Notice The information contained in this document is subject to change without notice GE makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability and fitness for a particular purpose GE shall not be liable for errors contained herein or incidental consequential damages in connection with the furnishing performance or use of this material This document contains proprietary information which is protected by copyright All rights are reserved No part of this document may be photocopied or otherwise reproduced without consent of GE Copyright 2001 by GE Published in a limited copyright sense and all rights including trade secrets are reserved Document Edition First 4 98 Second 5 99 Third 8 99 Fourth 11 99 Fifth 03 00 Sixth 10 00 Seventh 02 01 The following are products of General Electric Company POWER LEADER Meter 239 Motor Protection Relay GE Fanuc Series 90 30 PLC POWER LEADER Modbus Monitor 269 Plus Motor Management Relay GE Fanuc Series 90 70 PLC POWER LEADER Electronic Power 369 Motor Management Relay Power Quality Meter PQM Meter Spectra MicroVersaTrip SR469 Motor Management Relay EPM 7300 Electronic Power Meter Enhanced MicroVersaTrip C SR489 Generator Management Relay EPM 7700 Electronic Power Meter EPM 7600 Electro
23. R reete Re ORE 14 Instalng CIMPLICTLY ans reri dee ii aee edente 14 Installing Additional Software ss 15 Installing Additional Software ss 18 Installing the EPM Software Components sse 18 Installing the PMCS Softwares ete opo e eapite pst etitm eter edd 19 eLicensing PMCS software ss 19 License by Phone pea tete RR pte rens epe de dee pete eee bee tit 21 Host PC Installation msi D bRRPH De rE PERS Eep aa TRU 21 Viewer Workstation Installation esses eene 21 PMCS Installation Steps ss 22 PQ Analyst Installation Steps nennen 37 Un elicensing PMOS arce DE Tr ipe DE Re etre danseuse ut 40 Uninstalling PMCS etna optet een Slated neato nien 41 Reinstallation Steps ceci cepe dete eri harnais 43 Upgrading from previous versions to PMCS 6 9 44 CIMPLICITY PMCS Read This Book First Back to Main Page i ii e Contents Configuring the Software 45 Organize Your Informati n i oper e eee prp din 45 Configuration Procedure s r reui e rere ere e i e rdi un 47 EPM Device Special Considerations 49 Introduction 49 EPM Softwate Components eere bet eite rr ede ette pid eoe Re ege 50 Network Builder Building the Network Configuration File 50 ION Designer Programming Devices and Software Nodes ss 50 Communications Server System Communications 50 ION LINK DDE Server Commu
24. all the CIMPLICITY Wizards from any third party HMI tools Close any open applications Insert the PMCS Version 6 9 CD into the CD ROM drive From Start menu select Run and enter X setup where X is the appropriate CD ROM drive designation Read the general information and disclaimers shown on the screen and click Next Enter your name your company name and the serial number located on the PMCS CD jewel case then click Next If you make an error in the serial number the installation routine will prompt you for a correct PMCS serial number Choose the installation type either PMCS PMCS with EPM 7700 Components or Custom installation PMCS or PMCS with EPM 7700 Components installation will reinstall all components of the appropriate PMCS catalog number Select Custom if you wish to reinstall only selected PMCS software components CIMPLICITY PMCS Read This Book First Installing the Software e 43 44 e Installing the Software Upgrading from previous versions to PMCS 6 9 PMCS 6 9 provides an easy to use automatic upgrade path from previous versions of PMCS The software installer examines your hard drive and if it locates any previous version of PMCS it makes decisions on upgrading each component Follow the procedure below to upgrade your currently installed PMCS version such as 5 0 5 1 or 6 0 to PMCS version 6 9 This procedure assumes you have an existing PMCS installation with configured ports topics and optionally
25. art of the initial installation they will not be removed by the Uninstaller and must be deleted manually If you are uninstalling EPM 7700 components be aware that the Pegasys System Log Service does not properly unregister itself as an NT Service The following procedure will allow you to manually uninstall this component the remaining PMCS software can then be uninstalled in the usual manner Uninstalling the Pegasys System Log Service 1 Open a Command Prompt window 2 Make the C drive the current directory assuming your Windows system files reside on the C drive 3 Type slservice e EXACTLY as shown and hit enter 4 Ifthe Pegasys System Log Service was installed and running you will receive the message Pegasys System Log Service stopped If you do not receive this CIMPLICITY PMCS Read This Book First Installing the Software e 41 message the Log Service was not installed on your system Exit the command prompt and continue uninstalling PMCS 5 If you received the correct message in step 4 uninstall the service Type slservice u EXACTLY as shown and hit enter A message appears indicating Pegasys System Log Service uninstalled Exit the command prompt and continue uninstalling PMCS 42 e Installing the Software CIMPLICITY PMCS Read This Book First Reinstallation Steps Follow the procedure below to reinstall your PMCS software 1 If your system includes the PMCS Interface Toolkit uninst
26. chronization options then choose OK Repeat this step to add additional sites to the workstation if necessary 4 Insert devices to the site Select Items gt Insert gt Device and complete the dialog box with the proper device type Group Ethernet address and name for an Ethernet device EPM 7700 EPM 7600 or EPM 7500 The device name may be no more than eight alphanumeric characters and the first character must be alphabetic The IP service port field must be 7700 for any device connected to the Ethernet and 7800 for any additional device connected through an EPM 7700 s RS485 port Choose OK to close the Insert Device dialog box Repeat this step as necessary to add additional devices to the site 5 Save and exit When all workstations sites and devices have been added select the save icon and then exit CIMPLICITY PMCS Read This Book First EPM Device Special Considerations Introduction The GE EPM 7700 EPM 7600 and EPM 7500 devices add new level of power management capabilities to PMCS These EPM devices also require some special configuration which is not necessary for other PMCS compatible devices This section describes the additional requirements and configuration steps necessary to use the EPM 7700 EPM 7600 and EPM 7500 in conjunction with PMCS NOTE If you are not using the EPM 7700 EPM 7600 or EPM 7500 meters in your PMCS network it is not necessary to read this section of the manual Although the EPM 7700 E
27. d directly to step 4 Click the Start button from the Windows NT Task Bar and select Run 1 In the Run dialog box enter X setup where X is the appropriate CD ROM drive designation Iv Burin Seperate Memory Space ok cnoe Bronse CIMPLICITY PMCS Read This Book First Installing the Software e 37 2 The GE PMCS 6 9 Setup screen appears as shown below Read the general information and disclaimers shown on the screen and click Next Welcome x Welcome to the GE PMCS 6 9 Setup program This program will install GE PMCS 6 9 on your computer It is strongly recommended that you exit all Windows programs before running this Setup program Click Cancel to quit Setup and then close any programs you have running Click Next to continue with the Setup program WARNING This program is protected by copyright law and international treaties Unauthorized reproduction or distribution of this program or any portion of it may result in severe civil and criminal penalties and will be prosecuted to the maximum extent possible under law When you select the Next button in the Welcome screen the PMCS 6 9 license agreement screen is shown Please take a moment to read over the license agreement then click Next 3 At the User Information screen shown below enter your name your company name and the serial number for the PMCS component you are installing Serial numbers for PMCS
28. d install all of the PMCS software Any special installation steps are outlined for each software module Chapter 4 Configuring the Software describes how to efficiently configure PMCS to get up and running in the shortest time Chapter 5 EPM Device Special Considerations details the additional configuration required to use EPM 7700 EPM 7600 and EPM 7500 meters in a PMCS network You will find this book easy to use if you look for these simple conventions CIMPLICITY PMCS Read This Book First Boldface type indicates the name of an item you need to select Monospace type indicates an example or text that is displayed on the screen UPPERCASE type indicates a file name command name or acronym Introduction e 3 About CIMPLICITY PMCS Version 6 9 CIMPLICITY PMCS Version 6 9 is the latest Power Management Control System in the robust line of POWER LEADER power management products from GE Industrial Systems CIMPLICITY PMCS seamlessly integrates the comprehensive line of POWER LEADER devices as well as many new Modbus RTU devices and systems PMCS comes with built in Ethernet compatibility and is optimized for the Windows NT 4 0 operating system All of this adds up to the most flexible high performance open architecture power management system available PMCS software is the backbone of your new power management system with state of the art graphics and features designed to maximize productivity and minimize downtime and ener
29. e installations are complete the Setup Complete dialog box shown below prompts you to restart your computer Setup Setup has finished copying files to your computer Before you can use the program you must restart Windows or your computer C No will restart my computer later Remove any disks from their drives and then click Finish to complete setup NOTE Your computer must be restarted after installing PMCS software This step is critical to proper operation of software Un elicensing PMCS In order to unlicense your software to use your eLicense Order ID for another computer you must have an internet connection To retrieve your license for use on another PMCS installation simply right click on any PMCS executable on your desktop and select unlicense PMCS Unlicense PIS E3 If you unlicense PMCS your license will be removed from this computer and returned to the license server You can get the license again using your Order ID IMPORTANT Make sure you see the Unlicense Successful message If you don t see the message press Unlicense again Follow these steps 1 Make sure you are connected to the Internet If you are not sure click the link below to check your connection venise http www geindustrial com industrialsystems pmes ems softwarepmes html 2 Enter your Order ID in the space below Your Order ID has been given to you in your Purchase Confirmation e mail It has
30. e manufacturer s disk into the A drive Network 2x Identification Services Protocols Adapters Bindings Network Adapters LU Madge oman 16 7 AT Plus Ningnode j From the Network control panel select the Adapters tab then click Add len Notes CIMPLICITY PMCS Read This Book First Installing the Software e 15 Select Network Adapter HE Click the Network Adapter that matches your hardware and then EH click OK If you have an installation disk for this component click Have Disk Network Adapter BY SMC 9232 Fast Ethernet Adapter BY SMC 9332 EtherPowerl 0 100 PCI Fast Ethernet Adapter Star Gate ACL Avanstar Family Adapter BY SysKonnect SK NET 4 16 Token Ring Adapter BY SysKonnect SK NET FDDI PCI Adapter BTC nl Seen CK MOT RIC E Haenel Adler a Have Disk OK Cancel Select the appropriate network adapter from the list and click Have Disk Follow the instructions provided on the screen to complete the network card installation For PMCS systems using one or more GE Multilin RS232 to RS485 converters or equivalent no additional drivers are required Ethernet PMCS Network Interfaces If you are using an Ethernet interface card to connect to the PMCS network through one or more Ethernet Gateways or directly to a network of Universal Relays Modbus TCP IP follow the manufacturer s installation instructions and be sure to install the provided Windows NT drivers using Control Pan
31. eb connection to General Electric Industrial Systems eLicense distribution system CIMPLICITY PMCS Read This Book First Similar to the trial each eLicense is registered to the computer In which case the eLicense Order ID can only be used for one computer The software must be unlicensed to be re licensed with the same eLicense Order ID on another computer Select Launch from your License Installation Success Screen to continue installing PMCS License by Phone If your PMCS computer does not have an internet connection you may license your PMCS software over the phone by selecting the By Phone option on the Licensing Option Page This will bring you to a Phone License screen This screen provides a Toll Free Assistance Line 1 888 GE 4 SERV international callers please use 540 378 3888 that can be used to retrieve your unique eLicense key from a General Electric Industrial Systems customer support representative please select Technical Support then Software Licensing from the phone menu You will be asked over the phone for your System Identifier Version ID and Order ID and in return you will be given your eLicense key The eLicense Order ID from the License Confirmation sheet and the eLicense key given over the phone are required to Install the eLicense Similar to the trial each eLicense is registered to the computer In which case the eLicense Order ID can only be used for one PMCS computer The software must be unlicensed to be
32. el gt Network gt Adapters gt Add Adapter Refer to the screen shots above for an example though the selections will differ based on the hardware you are installing Ethernet requires the TCP IP protocol for compatibility with the Ethernet Gateway or Universal Relays TCP IP should have been installed with Windows NT Workstation 4 0 you can check this using Control Panel gt Network gt Protocols The screen shot below shows a system with TCP IP installed If TCP IP is not installed on your system refer to the Windows NT documentation for installation instructions 16 e Installing the Software CIMPLICITY PMCS Read This Book First Y AppleT alk Protocol Ethernet users HF NetBEUI Protocol Check the Y NwLink IPX SPX Compatible Transport Protocols tab of the Network control panel pened for TCP IP Protocol Local Area Network LAN Interfaces PMCS supports multiple Viewer Workstations through links over a local area network Thus in addition to the PMCS network interface the Host PC may also have a LAN interface A Host PC with an Ethernet PMCS network interface may use either the same Ethernet card as the LAN interface or a separate LAN interface card A Host PC with an RS485 PMCS network interface requires an additional LAN interface card to support Viewer Workstations Typical LAN interface cards include Ethernet and Token Ring Any LAN interface card should be installed according to the manufacturer s instructions
33. elect Components a XE I XI CIMPLICITY PMCS Read This Book First Installing the Software e 31 13 Next the installer prompts you to choose how you wish to install the PMCS components You may install them as standard applications which may be launched from the Start menu or you may choose to install the PMCS components as Window NT Services NT Services can be set to start automatically when the machine is powered up and have the powerful advantage of running in the background with no regard to users logon logoff cycles For example the PMCS Waveform Server when set to run as an NT Service continues to collect waveform data whether or not a user is logged on For further information on NT Services refer to your Windows NT documentation Choose whether to configure your PMCS components as NT Services then select Next Configure PHCS Windows NT Services 32 e Installing the Software CIMPLICITY PMCS Read This Book First If you chose to configure NT Services you ll also need to select the appropriate DDE Server The Select DDE Sever Configuration dialog is displayed for this action Select the DDE Server s you will be using with your application then choose Next Select DDE Server Configuration CIMPLICITY PMCS Read This Book First Installing the Software e 33 14 The Selected Components screen offers you the opportunity to verify the installation settings before any files are copied to your hard drive
34. ervices and meters Network Builder creates a central network configuration file that holds information for the workstation the network connections and every connected device You may want to restrict access to Network Builder or the network configuration file since if the file is tampered with EPM 7700 EPM 7600 and EPM 7500 components may be rendered inoperable ION Designer Programming Devices and Software Nodes The ION Designer component allows you to customize the operation of an ION compliant node such as 7000 series meters and 3000 series meters Be aware that misuse of ION Designer can adversely affect the operation of your meters IMPORTANT For purposes of PMCS network compatibility it is CRITICAL that any EPM 7700 EPM 7600 and EPM 7500 meters be configured with the GE PMCS standard configuration Using ION Designer to customize EPM 7700 EPM 7600 or EPM 7500 functionality can compromise compatibility with the PMCS client applications attempting to access the device Communications Server System Communications The Communications Server is the core communications component for EPM 7700 EPM 7600 and EPM 7500 meters The Communications Server manages all communications between the meters connected to your network and the GE77GTWY and ION_Link DDE Server software applications ION_LINK DDE Server Communication with Windows Applications The ION_LINK DDE Server uses Dynamic Data Exchange to share information with applicatio
35. g the Communications Server and GE 7700 a Software nodes Stationless Secondary EE Software Nodes nodes appear here DDESRV INSTALL DDESRV REM TE DESIGNER INSTALL Ethernet Site Defines the Ethernet DESIGNER REMOTE connection between the PMCS system UPGRADE INSTALL and the connected device s UPGRADE REM TE cx INSTALL Site INSTALL ETHER220 Device Name s of attached device s 52 e EPM Device Special Considerations CIMPLICITY PMCS Read This Book First Building the Power Monitoring Network in NetBuilder When Network Builder is running you can begin configuring your EPM system by adding a site to the workstation then adding devices to the site For larger systems multiple sites are added one for each network of devices monitored NOTE The PMCS installation wizard creates initial entries for the workstation and software nodes If you do not need to make changes to the information provided during installation skip this section and begin with the section title Adding an Ethernet Site Adding a Workstation When you use the PMCS installation wizard to install a Primary node or Full Station Secondary node it creates a Workstation in the Network Configuration for you Stationless Secondary nodes do not appear in the network configuration as workstations but as software nodes under the Primary workstation See the section on software nodes for more information To add a new workstation r
36. gy costs Performance With built in Modbus RTU and Ethernet compatibility PMCS delivers critical power management information faster than ever PMCS supports baud rates of up to 38 4 kbps on a Modbus RTU network and 10 Mbps on an Ethernet TCP IP network This results in near real time screen refresh rates and immediate access to critical event and alarm data Features PMCS comes with the following features that make the system more powerful and easy to use e Compatible with industry standard third party SCADA platforms e Built in Modbus RTU network compatibility for an open network architecture and high speed communications e Built in Ethernet TCP IP network compatibility for very high speed communications and reduced wiring costs e Built in support for the comprehensive line of POWER LEADER power management devices as well as additional GE meters and relays Fanuc 90 30 and 90 70 programmable logic controllers plus support for third party meters and relays e 3D virtual device interaction with accurately reproduced device look and feel e Improved waveform capture including extensive analysis tools e Comprehensive alarm and event reporting for immediate diagnosis of electrical system problems e Multiple Viewer Workstation support for seamless access and sharing of power management data across your existing LAN e Configurable password protection and user activity logging for improved security and restrictio
37. has CIMPLICITY HMI installed make sure the following requirements are met CIMPLICITY PMCS Read This Book First e CIMPLICITY HMI for Windows NT Intel Version 4 01 with HMI Service Pack 9 or CIMPLICITY HMI for Windows NT Intel Version 5 00 with HMI Service Pack lis required Other versions of CIMPLICITY may not be compatible with PMCS If you are installing CIMPLICITY HMI follow the directions provided with the software inside the CD jewel case Choose CIMPLICITY HMI as the product to install then select either the HMI Server or Viewer as the product option to install and C CIMPLICITY HMI as the installation directory If you install the Server option also install Server Option Communications Advanced DDE DDE Client Installing Additional Software Install any additional software such as Microsoft Excel at this point in the procedure Follow the instruction procedures provided by the manufacturer For instructions on installing SISCO Systems MMS Server for use with PMCS refer to the section titled Using MMS Servers with PMCS RS485 PMCS Network Interfaces If you are using an RS485 interface card to connect to the PMCS network install the card following the manufacturer s installation instructions Be sure to install any Windows NT drivers provided by the interface card vendor Typically drivers are installed at Control Panel Network Adapters Add Adapter by following the instructions You may be prompted to insert th
38. her users CIMPLICITY PMCS Read This Book First EPM Device Special Considerations e 55 such as on a corporate LAN Refer to the PMCS Network Architecture Guide for guidelines on setting this parameter for best system performance e Change the RX timeout delay from 10000 to 30000 on the Advanced tab See the following figure for Advanced tab All other parameters may be left at their default values for most applications When you click OK in the Add Site dialog box Network Builder will inform you if there is additional information you must enter PRIMARY Add Ethernet Site Ok f cm He 56 e EPM Device Special Considerations CIMPLICITY PMCS Read This Book First netconfig dat File View Item r System cj Big PRIMARY E a Software DDE DES m PRIMAF Ready misil ERST COE Ethernet Device x General Advanced sjaje l Type Power Measurement 7700 ION Group PRIMARY Name EPM 7700 IP Address s 46 9 215 IP Service Port 7700 Priority Time i it ID Priority Unit ID 100 The p Numbe Timen r MEM NUM h Adding Devices Meters To add a meter right click on the Ethernet site you want to add the meter to and select Insert Device from the pop up menu The Add Ethernet Device dialog box appears shown below Contin Diagnc Maxim Enter the following information e Choose the meter type from the Type list Power
39. ight click System and choose Insert Workstation from the pop up menu The System Add Workstation dialog box appears as shown below Type the network name of the computer in the Name field Use the default settings on the Advanced tab Click OK then proceed to Adding Software Nodes below amp netconfig dat PEGASYS Network Builder Ele View ltem i zu Pele eal el Add Workstation System General Advanced Name PRIMARY Cancel Help b NUM Z CIMPLICITY PMCS Read This Book First EPM Device Special Considerations e 53 Adding Software Nodes Software nodes identify the various software components in the network Stationless Secondary nodes although they are physically separate computers do not run a Communications Server and are therefore not considered Workstations by Network Builder Instead Stationless Secondary nodes appear in the network diagram as software nodes under the Primary Workstation Full Station Secondary nodes appear as Workstations because they do run an instance of the Communications Server Acknowledging the Add Workstation dialog brings up a message box asking if you want to set up the default software nodes choose Yes to display the software nodes dialog shown below Select only ION Designer and Pegasys ION_Link DDE Server as shown then click OK to proceed The other options are not supported in PMCS 5
40. iguration for running PMCS Version 6 9 Note that regardless of configuration the PC system must be Windows NT certified according to the Microsoft Windows NT 4 0 Hardware Compatibility List available from Microsoft www microsoft com In addition to the requirements described below setting up PMCS and EPM 7700 workstations will require Windows NT Administrator level authority privileges Pentium Il processor 300 MHz Pentium IIl processor 600 MHz Microsoft Windows NT 4 0 Workstation Microsoft Windows NT 4 0 Workstation or Service Pack 6 Windows 2000 Professional Server Service Pack 6 Windows 2000 Cimplicity version 4 01 Service Pack 9 or Professional Cimplicity version 4 01 Service Cimplicity version 5 0 Service Pack 1 Pack 9 or Cimplicity version 5 0 Service Pack 1 128 megabytes of RAM 256 megabytes of RAM 512K cache 512K cache 4 gigabyte hard disk 10 gigabyte hard disk CD ROM drive CD ROM drive Note For systems using MMS technology refer to Using MMS Servers with PMCS for minimum system requirements Additional hard disk space is recommended for increased storage of log and trend data Also recommended are an uninterruptable power supply UPS 17 or larger monitor tape drive or other backup mechanism and if Remote Access technical support is desired a 28 8 Kbps or faster modem The version of CIMPLICITY installed must be 4 01 or greater and HMI Service Pack 9 must be installed Also the Adva
41. ion information click Next User Information lt your name here gt your company here gt your serial number here When you select the Next button in the User Information screen a registration confirmation screen prompts you to verify your entries Ensure that you have made no mistakes in the User Information fields then continue 24 e Installing the Software CIMPLICITY PMCS Read This Book First 6 At the Choose Destination Location dialog specify a drive on which to install PMCS Default is C Click Next to continue Choose Destination Location CIMPLICITY PMCS Read This Book First Installing the Software e 25 7 At the Setup Type screen select either a Custom installation standard PMCS installation or PMCS with EPM 7700 Components PMCS installation is recommended and will install all components for the PMCS catalog number you entered in the User Information screen Select PMCS with EPM 7700 Components if you will be installing EPM 7700 EPM 7600 or EPM 7500 devices in your network Select Custom if you wish to select specific PMCS software components to install Click Next to continue Setup Type If you select PMCS with EPM 7700 Components you may also be required to view an additional license agreement for MS Data Access components This software is required by the EPM 7700 software Take a moment to read the license agreement information then continue 26 e Insta
42. llation procedures assume that you are familiar with Windows NT 4 0 and your computer Carefully read the following notes that pertain to installing your AXS MMS 132 095 product Follow the steps below to install AX S4 MMS for Windows NT on your system 1 Insert the AXS4 MMS 132 095 CD ROM into the CD ROM drive 2 Ifthe Autorun feature is enabled on your computer go to Step 3 Otherwise click on Start select Run and enter X disk1 setup where X is the appropriate CD ROM drive designation 3 When the AX S4 MMS Setup initializes you are presented with three installation choices Typical Minimal and Custom Typical the recommended selection will install the core AX S4 MMS and SISCO OSI Stack components including AX S4 MMS samples Minimal will only install the AX S4 MMS and SISCO OSI Stack components Custom will allow you to select only those components that are required for your installation When using this option you may also choose to install the electronic copy of the AX S4 MMS User s Guide 4 Follow the instructions on the screen to complete the AX S4 MMS installation Note When the AX S4 MMS Setup is complete you will be asked if you want to restart the computer Select the option No I will restart my computer later Click the Finish button 5 Install the OSI LLC Protocol Driver for Windows NT Note If you are replacing an existing version of the OSI LLC Protocol Driver you need to remove the current version Selec
43. lling the Software CIMPLICITY PMCS Read This Book First 8 If you did not select PMCS with EPM 7700 Components in the Setup Type dialog box Step 7 skip this step and proceed to Step 11 If you are installing the EPM 7700 Components select whether this is to be a Primary node installation or Secondary node installation You must install at least one Primary node on your PMCS network it is recommended that you install the Primary node at the same machine as the PMCS DDE Server for convenience in configuration Secondary nodes are akin to PMCS view nodes and may be installed on remote machines to access EPM 7700 data from the Primary node For additional details on Primary and Secondary nodes see the section on configuring EPM 7700 components later in this chapter Select EPM 7700 installation type CIMPLICITY PMCS Read This Book First Installing the Software e 27 9 If you did not select PMCS with EPM 7700 Components in the Setup Type dialog box Step 7 or if you selected Primary Node Installation in Step 8 skip this step and proceed to Step 11 If you selected Secondary Node installation in Step 8 the following dialog box appears prompting you to select either Full Station or Stationless node installation If you are installing software on a computer that will service EPM 7700 EPM 7600 or EPM 7500 IEDs directly choose Full Station If you are installing software on a computer that will not be connected to
44. m Analyst application to browse a large amount of power quality survey data with ease using a graphical interface on a Microsoft Windows platform Waveform Analyst SETUP CIMPLICITY PMCS Read This Book First Installing the Software e 35 19 When all the installations are complete the Setup Complete dialog box shown below prompts you to restart your computer Setup Complete After restarting your computer be sure to view the ReadMe file to check any late breaking information useful to the configuration or operation of your PMCS system NOTE Your computer MUST be restarted after installing PMCS software This step is critical to proper operation of the software as it enables the following to happen e The operating system will register the new software components e The MMS Server if installed will update its alias table e Initial network configurations for EPM7700 EPM 7600 and EPM 7500 devices will be created 36 e Installing the Software CIMPLICITY PMCS Read This Book First PQ Analyst Installation Steps Follow the procedure below to install each PMCS catalog number Be sure the catalog numbers you are installing are appropriate for the destination PC Host PC or View Node Close any open applications before installation Insert the PMCS Installation CD into the CD ROM drive If CD AutoStart is enabled the PMCS installation routine will launch automatically In this case skip steps 2 and 3 and procee
45. n of setup or control operations PMCS option modules are available to further increase productivity and reduce energy costs Your system may include one or more of the following modules 4 e Introduction CIMPLICITY PMCS Read This Book First e CIMPLICITY PMCS Interface Toolkit with tools to quickly create accurate intelligent floorplans one line diagrams and elevation views e System Test Simulator to design and test PMCS systems without connection to real networks or devices CIMPLICITY PMCS Read This Book First Introduction e 5 6 e Introduction Supported Devices CIMPLICITY PMCS 6 9 supports the following devices Firmware revisions other than those listed may not be compatible with PMCS Contact your GE Sales Representative or the GE Resolution Center at 1 888 GE RESOLV for more information Device Firmware Revision Supported POWER LEADER EPM commnet communications option Modbus communications option POWER LEADER Meter EPM 3710 Electronic Power Meter EPM 3720 Electronic Power Meter P ower Quality Meter PQM POWER LEADER MDP Overcurrent Relay commnet communications option Modbus communications option Spectra MicroVersaT rip Enhanced MicroVersaTrip C Enhanced MicroVersaTrip D 4 13 Spectra ECM Electronic Control Module 72 239 Motor Protection Relay 24 269 Plus Motor Management Relay D 6 0 4 369 Motor Management Relay 1 45 SR46
46. nced DDE Communications option must be installed Microsoft Internet Explorer 3 02 or later is required to run the EPM 7700 component help system To take advantage of all available HTML help features Internet Explorer version 4 0 or higher must be installed The latest version of Internet Explorer is available at www microsoft com Please note that the host PC requirements are directly tied to the complexity of your PMCS system The minimum requirements will suffice for a simple PMCS system However as the number and complexity of your power management device grows and you add more complex software requirements such as custom interfaces designed with third party HMI tools your PC requirements increase as well A faster processor and more memory provide better performance for your PMCS system Where to Get Help The GE Industrial Systems Resolution Center is available at 1 888 GE RESOLV to answer your questions about installing or using PMCS Please have your product serial number s ready when calling Also technical notes are available on the Internet at http www ge com industrialsystems pmsys Technote noteidx htm CIMPLICITY PMCS Read This Book First Getting Started 11 What s next The following chapters discuss the details of installing and getting quick results from your new PMCS software Set aside at least an hour and be sure to follow the procedures carefully to guarantee correct installation of your PMCS software
47. nic Power Meter EPM 7500 Electronic Power Meter Enhanced MicroVersaTrip D 565 Feeder Management Relay EPM 3710 Electronic Power Meter MDP Overcurrent Relay 735 Feeder Relay EPM 3720 Electronic Power Meter System Monitor SM 3 SR745 Transformer Management Relay Spectra Electronic Control Module Universal Relay SR750 SR760 Feeder Management Motor Manager II MMII Relay Microsoft Microsoft Excel and Microsoft PowerPoint are registered trademarks and Windows NT is a trademark of Microsoft Corporation DFP 100 and DFP 200 Feeder Management Relay and Multilin 269 Motor Management Relay are registered trademarks of Multilin Inc and Multilin SR489 Generator Management Relay and Multilin SR745 Transformer Management Relay are trademarks of Multilin Inc US Pat Nos 5 768 148 5 764 155 5 862 391 Back to Main Page Contents Introduction 3 Welcome te OUR m ES SEE Guu cold EI E ESI p e ules EEEE 3 How to Use this Book e oett E er UR En e SOT E 3 About CIMPLICITY PMCS Version 6 9 eene eene nennen 4 Performance E 4 Dini pe E 4 Supported Devices ec ette ir ette cet etre Redde cte ire het dete ederet 6 Getting Started 8 First Steps esce teret Hee ti itr eer E LRG Ate cose e eb Lames 8 Understanding Terminology ss 8 System Requirements ss 11 Where to Get Help lies sn interne ere DER Deme 11 Wh t Snext sans nn Hero e efie el oe e rented 12 Installing the Software 14 Computer Preparation nette Dem D e ROSE ERREU
48. nication with Windows Applications 50 Workstation Configuration Guidelines ss 51 Configuring the EPM Device Network ss 52 Running Network Builder 5 eite tee te rete tetigerit eite 52 Building the Power Monitoring Network in NetBuilder sss 53 Adding Devices Meters seen tete ere eet a eben xoti Ee eer Riera 57 Saving and Exiting aio oa rte et eer EP eee ERR Pee et bete de eeu ch 57 Using MMS Servers with PMCS 59 What isan MMS Server innana aa E e eie etur ee teet 59 System Requirements ss 59 Installation for Windows NT 4 0 iii 60 Preparing the MMS Server for use with PMCS sse 61 Index 66 CIMPLICITY PMCS Read This Book First Introduction Welcome Hello and welcome to the POWER LEADER Power Management Control System for CIMPLICITY HMI You are about to begin using your computer in an exciting new way as a tool to help you increase productivity while reducing downtime and energy costs This book is for anyone getting started with CIMPLICITY PMCS It contains the information you need to install and begin using PMCS effectively How to Use this Book Chapter 2 Getting Started explains the terminology of power management systems describes each of your PMCS items outlines the minimum system requirements and lists methods of getting GE Technical Support Chapter 3 Installing the Software explains how to prepare your system an
49. ns describe how to set up your MMS Server for DDE access by PMCS applications such as Event Logger and Waveform Capture Both MMS Server and PMCS must be properly installed before following these instructions 1 Launch the AX S4 MMS Configuration Program Start gt Programs gt Sisco gt AXS4 MMS gt AXS4 MMS Configuration and select Configure gt Configuration gt Network gt Addressing This displays the Network Addressing window shown below o Network Addressing Se Host Names AR Names HostName Network Address IP Address axs mms 27 0 0 1 Close Refresh Goto PEE Host Name a s4mms Advanced Network Address IP Address 127 0 0 1 v Duplicate Delete E e j amp veneedy w Daise pas M Local Host Choose New to start the wizard for creating a new host The Host Name Wizard Host Name dialog box is displayed CIMPLICITY PMCS Read This Book First Using MMS Servers with PMCS e 61 Host Name Wizard Host Name 2 Enter a name for the host you are creating then choose Next to display the Host Name Wizard Addressing dialog box Host Name Wizard Addressing 3 Complete the TCP IP Network question by selecting the Yes checkbox and entering an IP address for the new host then select Next 62 e Using MMS Servers with PMCS CIMPLICITY PMCS Read This Book First Host Name Wizard Finished TES 4 VAE 4 2 Saw
50. ns such as Microsoft Excel or the CIMPLICITY Wizards 50 e EPM Device Special Considerations CIMPLICITY PMCS Read This Book First Workstation Configuration Guidelines If you are using the EPM 7700 EPM 7600 or EPM 7500 Meters in your PMCS network the following guidelines in this section must be adhered to before continuing with the EPM configuration NOTE If you are adding a PMCS installation to an existing network please refer your network administrator to GEH 6502 the PMCS Network Architecture Guide for integration details CIMPLICITY PMCS Read This Book First Each computer in the network must be assigned a Windows NT computer name The name must be one to fifteen alphanumeric characters in length Spaces may not be used and the first character of the computer name may not be numeric The System Control Panel should have the Performance Boost for Foreground Application value set to None and a paging file should be created on the C drive with the Initial and Maximum sizes set to twice the workstation s installed RAM The Network Control Panel s Adapter tab should have the MS Loopback adapter installed if a physical network adapter is not installed in the workstation Under the Protocols tab TCP IP or NetBEUI should be installed if TCP IP is installed use IP address 192 168 100 xxx and subnet mask 255 255 255 0 unless your network administrator has assigned you an IP address Under the Services tab install Remote Access
51. nuals provided See step 3 of the Host PC Configuration for the appropriate instruction manual numbers CIMPLICITY PMCS Read This Book First Configuring the Software e 47 48 e Configuring the Software EPM Software Components Configuration The EPM 7700 EPM 7600 and EPM 7500 requires several separate software components which are installed during the PMCS setup This section provides a brief overview of the steps required to configure these components the following section describes the EPM software components in greater detail For details of using the NetBuilder software refer to the Configuring the EPM 7700 Device Network section of this manual and to DEH 440035 the GE 7700 Gateway User s Guide 1 Launch the NetBuilder application From the Start menu select Programs gt Power Management Ltd gt Utilities gt Network Builder 2 Insert a workstation s Normally all the workstations in a PMCS network are automatically configured during the installation of the software these instructions are provided in case you need to enter the information manually Select the Items menu from NetBuilder and choose Workstation to insert a workstation Name the workstation up to 15 alphanumeric characters the first character must be alphabetic and choose OK Repeat this step for each workstation computer in your network 3 Insert Ethernet Sites Select Items gt Insert gt Ethernet Site to insert an Ethernet site Set the proper time syn
52. of the PMCS installation routine PMCS Power Management Control System GE s high performance power management system for Windows NT including open network protocols waveform capture and analysis event logging and several optional modules POWER LEADER The family of GE power management devices including meters relays trip units and software RS485 An industry standard communication network supporting up to 32 networked devices RS485 provides medium speed reliable communication transport through shielding balanced transmission voltages and termination SCADA Supervisory Control and Data Acquisition A category of systems that primarily acquires data for logging and analysis as well as providing supervisory control in applications without time critical requirements Power management systems are a direct application of SCADA technology TCP IP Transmission Control Protocol Internet Protocol An industry standard protocol typically used on Ethernet or Token Ring local area networks LANs Waveform Capture A standard PMCS application that provides a window into power quality data in an electrical system Waveform Capture is used to view snapshots of voltage and current waveforms from various points in an electrical system to analyze harmonics and unusual system behavior CIMPLICITY PMCS Read This Book First 10 e Getting Started System Requirements The following table shows the minimum and recommended PC system conf
53. opriate PMCS catalog number Select Custom if you wish to reinstall only selected PMCS software components 6 After upgrading existing HMI applications that use PMCS wizards will continue to work If you upgrade device firmware you will need to replace the old wizard screens with new screens to maintain compatibility between your application and the device The old PMCS wizards will remain on your system unless you uninstall the previous version of PMCS It is highly recommended that all new applications use PMCS 6 9 Advanced wizards exclusively 7 After upgrading launch the PMCS DDE Server The Server will convert your previous PMCS configuration to a PMCS 6 9 configuration WARNING Event Logger users only Upgrading your EventServer or Eventlogger application will result in the loss of all device configurations and annunciator panel items Make a list of these items so that they may be reconstructed in the new application Existing database files will be backed up by the installation program but they cannot be viewed with the PMCS 6 9 EventViewer To view databases created with earlier editions of PMCS use Microsoft Access to open the mdb files CIMPLICITY PMCS Read This Book First Configuring the Software To get the most out of your new PMCS system follow the directions below to configure your system Organize Your Information Host PC You need the following information to properly configure the PMCS software for the Host
54. ptimized for Ethernet TCP IP or RS485 Modbus RTU networks DDE Dynamic Data Exchange A Microsoft Windows standard for efficient sharing of data between applications on the same PC See also NetDDE Ethernet Gateway A POWER LEADER device used to connect four RS485 Modbus RTU networks to an Ethernet TCP IP network The Gateway increases performance of a PMCS system through multiple Modbus networks and reduces overall wiring costs through reuse of existing Ethernet LAN wiring Ethernet An industry standard communication network commonly used for local area networks LANs of PCs Ethernet PMCS systems provide very high speed reliable communications at 10 megabits per second Event Logger A standard PMCS application that efficiently analyzes sorts and logs unusual system behavior such as circuit breaker trips undervoltages and overcurrents Extensive data logging capabilities make it a useful tool for analyzing and predicting system maintenance patterns Host PC The PC running the PMCS DDE Server is referred to as the Host PC All other PCs running PMCS client programs are referred to as Viewer Workstations or networked PCs Interface Toolkit An optional PMCS tool used to quickly generate accurate and friendly graphical user interfaces The Interface Toolkit provides dozens of wizards to efficiently create intelligent one line diagrams equipment elevation views floor plans 3D virtual faceplate views and tabular displays Modbus
55. re licensed with the same eLicense Order ID on another computer Select Launch from your License Installation Success Screen to continue installing PMCS Host PC Installation Every PMCS system requires one Host PC that is directly connected to the PMCS network and communicates with the power management devices The Host PC is also typically used to view and analyze data If you are installing multiple PMCS catalog numbers on the Host PC you will need the CD and serial number from each package Follow the Installation Steps section below If the Host PC will be providing data to View Nodes be sure to refer to GEH 6510 Network and Device Configurator to configure NetDDE for operation with the View Node PCs Viewer Workstation Installation PMCS supports optional Viewer Workstations which interact with the power management network through NetDDE links to the Host PC Viewer Workstations are not directly connected to the PMCS network but are connected via LAN to the Host PC Viewer Workstations are not mandatory in a PMCS system because the data is available for display and analysis at the Host PC When installing PMCS View Nodes be sure to use only an appropriate catalog number for the installation Do not install any other PMCS software on a PMCS Viewer Workstation CIMPLICITY PMCS Read This Book First Installing the Software e 21 NOTE The EPM software differs from the standard PMCS usage of Viewer Workstations Refer to the section
56. ructions refer to DEH 40035 the GE 7700 Gateway Server User s Guide Configure the user interface If your system was provided with a generic HMI software application either load or create the custom HMI using the Interface Toolkit wizards if appropriate see DEH 210 CIMPLICITY PMCS Interface Toolkit or refer to the HMI software s documentation Configure the applications As appropriate configure the following application modules referring to the instruction manuals provided e Event Logger GEH 6512 e Waveform Capture GEH 6511 Test the applications Test the functioning of all applications to ensure proper Host PC operation Do not proceed to step 5 until you are sure the Host PC operates as expected Set up NetDDE If your system has one or more View Nodes set up NetDDE shares and trusts in the Host PC following the procedures in GEH 6510 Network amp Device Configurator and the CIMPLICITY HMI documentation Set up NetDDE If your system uses the PMCS Waveform Capture client and you intend to access waveform data from View Nodes set up NetDDE shares and trusts for the PMCS Waveform Server following the procedures in GEH 6511 PMCS Waveform Capture Module Viewer Workstation Configuration 1 Configure the user interface Load the custom MMI Refer to the CIMPLICITY HMI documentation as appropriate Configure the applications As appropriate configure the application modules referring to the instruction ma
57. t the Services dialog tab highlight the OSI LLC Protocol Driver and click the Remove button Click on OK Click the Close button and reboot your computer When the system reboots set the directory to the Windows System Drivers System32 Drivers and delete the file osillc sys The installation process will fail to load the correct OSILLC device driver if an older version of the device driver is present in the system directory 6 Click on Start gt Settings gt Control Panels From the Control Panel folder select the Network shortcut 7 Select the Protocols dialog tab and click the Add button 8 From the Select Network Protocol dialog box click the Have Disk button 9 From the Insert Disk dialog box type the path d osillc winnt where d designates the letter of your CD ROM drive and click on OK to accept the path 10 From the Select OEM Option dialog box click on OK then click the Close button and restart your computer 11 The following directory structure should now appear on your computer lt Drive gt OSILL2 All OSI Stack files lt Drive gt AXS4MMS All AX S4 MMS files Note If you are installing for both Windows 95 and Windows NT you should install the product into the same directory This will allow you to share the same configuration database between both platforms 60 e Using MMS Servers with PMCS CIMPLICITY PMCS Read This Book First Preparing the MMS Server for use with PMCS The following instructio
58. titled EPM Device Special Considerations for more details on EPM Workstations and View Nodes PMCS Installation Steps Follow the procedure below to install each PMCS catalog number Be sure the catalog numbers you are installing are appropriate for the destination PC Host PC or View Node Close any open applications before installation 1 Insert the PMCS Installation CD into the CD ROM drive 2 Click the Start button from the Windows NT Task Bar and select Run 3 In the Run dialog box enter X setup where X is the appropriate CD ROM drive designation D Setup exe v L CGR canoe Bronse 22 e Installing the Software CIMPLICITY PMCS Read This Book First 4 The GE PMCS 6 9 Setup screen appears as shown below Read the general information and disclaimers shown on the screen and click Next When you select the Next button in the Welcome screen the PMCS license agreement screen is shown Please take a moment to read over the license agreement then click Next CIMPLICITY PMCS Read This Book First Installing the Software e 23 5 At the User Information screen shown below enter your name your company name and the serial number for the PMCS component you are installing Serial numbers for PMCS components are located on the PMCS CD ROM jewel case If you make an error in the serial number the installation routine will prompt you for a correct PMCS serial number When you have completed the registrat
59. ts and skip ahead to Chapter 3 Getting started with PMCS is easy This chapter explains power management and leads you through the steps to take prior to installing your PMCS software If you need help with your PMCS system the GE Technical Support telephone number is given at the end of this chapter Understanding Terminology Power management system terminology can be intimidating to new PMCS users The list below defines many of the important terms and acronyms used in this guide and other PMCS manuals Refer back to this list as new terms are presented later Baud rate measurement of a communication channel s signaling rate or information carrying capacity Communicating devices typically have configurable baud rates to provide compatibility with various speed communication networks Higher baud rates generally provide faster data refresh times CIMPLICITY HMI An industry standard SCADA software package providing flexible accurate and easy to use graphics CIMPLICITY HMI is based on a client server architecture consisting of Servers and Viewer Workstations Servers are responsible for the collection and distribution of data Viewer Workstations connect into Servers and have full access to the collected data for viewing and control actions Servers and Viewer Workstations can be easily networked together to seamlessly share data without the need to replicate your point database from node to node CIMPLICITY HMI Server Development
60. when integrating devices that comply to the UCA MMS 2 0 standard For details on the SISCO AX S4 MMS Server refer to the AX S4 MMS for Windows 95 and Windows NT User s Guide which shipped with your MMS software product For convenience installation and setup instructions to prepare an MMS Server for access by PMCS applications are provided here System Requirements The following table shows the minimum recommended PC system configuration for running the MMS Server and software with PMCS Version 6 9 Note that regardless of configuration the PC system must be Windows NT certified according to the Microsoft Windows NT 4 0 Hardware Compatibility List available from Microsoft www microsoft com In addition to the requirements described below setting up PMCS and EPM7700 workstations will require Windows NT Administrator level authority privileges as described earlier in the Getting Started section Minimum PC Requirements for using MMS Technology with PMCS Dual Pentium IIl processor 500 MHz or better Microsoft Windows NT 4 0 Workstation Service Pack 3 SP5 recommended Windows 2000 Professional Cimplicity version 4 01 Service Pack 9 or Cimplicity version 5 0 Service Pack 1 256 megabytes of RAM 512K cache 10 gigabyte hard disk Super VGA video adapter and monitor CD ROM drive CIMPLICITY PMCS Read This Book First Using MMS Servers with PMCS e 59 Installation for Windows NT 4 0 The following insta