1. manner Aging lamps should be replaced based upon the Lamp Manufacturer s recommendations and the lighting requirements for the installation Mounting Arm Washer Spacer 1 req d more as needed 3 Nuts W x screw 2 3 Studs 2 Adapter GE Lighting Solutions e 1 888 MY GE LED e www gelightingsolutions com 1 888 69 43 533 GE Lighting Solutions is a subsidiary of the General Electric Company Evolve and other trademarks belong to GE Lighting Solutions The GE brand and logo are trademarks of the General Electric Company 2011 GE Lighting Solutions Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 35 201578 Y2 11 99
2. GE Lighting Solutions GEH 5774B INSTRUCTIONS Dimension 1000 Luminaire READ THOROUGHLY BEFORE INSTALLING A WARNING Risk of electric shock e Turn power off before servicing seeinstructions GENERAL This luminaire is designed for outdoor lighting applications and should not be used in areas of limited ventilation or in high ambient temperature enclosures it should be installed and maintained according to following recommendations UNPACKING This luminaire has been properly packed so that no parts should have been damaged during transit Inspect to confirm INSTALLATION To install it is necessary to open the luminaire A flat blade screw driver socket wrenches for 1 4 5 16 3 8 and 9 16 hex head bolts are required Figure 1 Reflector Plate Retaining Screw Reflector Attachment Screws 4 from opposite side of plate To reinstall reflector plate assembly slide plate between hinges and housing flange Door Latches Make reflector aiming and wiring adjustments prior to mounting the luminaire on the pole Power leads should be pulled as mounting parts are assembled REFLECTOR AIMING ADJUSTMENT Reflectors can be rotated to any of four beam aiming positions by removing the screws holding the reflector to the reflector plate rotating the reflector into the desired position and replacing the screws Take care in replacing the reflector plate so tha
3. amp fixture to cool before handling Use only lamps specified on nameplate Observe lamp manufacturer s recommendations and restrictions on lamp operation particularly ballast type burning position etc Observe lamp manufacturer s handling instructions Lamps should be installed to NEMA EEI specified tightness of 35 inch lbs torque MOUNTING A CAUTION Unit will fall if not installed properly e Follow installation instructions Figure 2 DRILLING TEMPLATES Nut Plate 438 DIA 11mm 2 HOLES 312 DIA 8mm HOLE 1 25 DIA 32 mm HOLE 438 DIA 11 mm 2 HOLES Round Poles Predrill pole as directed in Figure 2 Install the two 2 Studs into the nut plate or nuts in the round pole adapter until the threads are fully engaged CAUTION Ensurethatnuts fully engagethetwostuds Correct tightening ofstudnutsis importanttoensureproperfunction of mountingsystem Torqueto 18 22 foot pounds PHOTOELECTRIC CONTROL If present the receptacle should be oriented to true North before the control is installed Loosen the two 2 screws holding the receptacle rotate it until the arrow points North and retighten the two 2 screws MAINTENANCE AND CLEANING The exterior of the door glass should be cleaned when dirty with a warm solution of mild non abrasive detergent and water Rinse with water and wipe dry If required the inside of the optical assembly may be cleaned in a similar
4. t the lamp socket leads are not pinched between the plate and the housing See Figure 1 WIRING AND WIRING ADJUSTMENTS Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements Verify that supply voltage is correct by comparing it to nameplate If unit is designated as multivolt or multiwatt follow specific instruction Do not remove insulated connectors from wires not needed for required voltage connection Terminal Board will accept power leads from AWG No 14 through No 6 wire size IF SINGLE VOLTAGE All single voltage ballasts are pre wired such that user need only connect the supply conductors IF MULTIVOLT 120 208 240 277 volts Connect the ballast lead with the insulated terminal to the desired voltage terminal as indicated on the ballast terminal nameplate These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to GE Lighting Solutions IF MULTIWATT Multiwatt ballasts are available in various combinations of wattage See wiring instructions on wiring tag inside the luminaire LAMP INSTALLATION AY CAUTION Risk of burn e Allow l

Download Pdf Manuals

image

Related Search

Related Contents

New York Wire FCS8732-M Instructions / Assembly  Manual del Usuario – Aplicativo  Tecumseh AE4430U-AA1ACK Technical Data Sheet  Sanyo SR-L4110W User's Manual  Archos FM Remote Control User's Manual  Major - Saelen  Yamaha Portatone PSR-31 Owner's Manual  TRAC Angler Anchor Winch User Manual  

Copyright © All rights reserved.
Failed to retrieve file