Home

GE Compact Fluorescent Installation Guide

image

Contents

1. N Mounting Plate e q I i e Figure 2 Figure 3 These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to GE Lighting Solutions a Screws 6 Inches 152 mm A ob Gasket 07 ONT Cover Figure 6 D Luminaires with primary disconnects outlet box hanging hardware Figure 7 rigid pendant hardware Figure 8 and flexible pendant hanging hardware Figure 9 1 Remove cover plate s and attach hanging hardware to pendant conduit and tighten set screw Figure 9 Figure 7 Figure8 2 Feedsupplywirethrough conduit andinto disconnect housing Make necessary wire connections 3 Slide the extrusion attached to the luminaire completely into the hanger extrusion Replace cover plate Cover plate is necessary to lock luminaire into place on the hardware cover electrical connections and if so equipped seal unit from water WIRING Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements Verify that supply voltage is correct by comparing it to nameplate For Rigid Pendant and Flexible Pendant mounting customer s supply connections must be above t
2. Tous les ballasts de tension puissance unique sont pr c bl s et peuvent se laver avec une solution de d tergent m nager doux dans de l eau ti de avec l utilisateur n a qu brancher les fils secteurs d arriv e rin age l eau claire et essuyage Si l ensemble optique int rieur devenait sale nettoyez r flecteur et l int rieur du r fracteur comme d crit plus haut Remplacez le joint s il est endommag APPAREIL MULTITENSIONS 120 208 240 277 V Les unit s arrivent par s curit pr cdbl es pour du 277 V Pour modifier l unit si la tension secteur est inf rieure D branchezle fil d arriv e d alimentation du fil de ballast 277 V dont vous isolerez l extr mit nue Rebranchez le fil d arriv e d alimentation sur le fil du ballast marqu la tension voulue Le fil d arriv e d alimentation doit tre d nud sur 9 mm et fermement ins r dans le bloc de terminaison en plastique sur le fil de ballast de tension voulue Remplacement d ampoule Le niveau d clairage d un luminaire est galement d pendant de l ge de son ampoule Dans les applications o le niveau lumineux est critique il peut tre judicieux de remplacer les ampoules avant qu ellesne soient grill es Consultez les donn es du fabricant d ampoules pour la fr quence des remplacements et d autres aspects de s curit AMPOULES N utilisez que des mod les d ampoules sp cifi s sur la plaque signal tique Suivez les recommandations et les restri
3. 10 MAINTENANCE CAUTION Risk of burn e Allow lamp fixture to cool before handling WARNING Risk of burn e Do not touch operating luminaire Cleaning Occasionally it will be necessary for the refractor to be cleaned to maintain appearance and light levels The frequency of cleaning will be dependent on the ambient dirt level and minimum light level required Refractor and housing should be washed with a solution of warm water and mild household detergent rinsed with clean water and wiped dry Should the interior optical assembly become dirty clean the reflector and interior of refractor as described above Replace gasket if damaged Lamp Replacement Light output of a luminaire is also dependent on the age of the lamp In applications where light level is critical it may be desirable to replace lamps before the burn out Consult lamp manufacturer s data for lamp replacement frequency and other safety issues Replace blackened lamps immediately GE Lighting Solutions GEH 5971B INSTRUCTIONS Garage Guardian Luminaire de garage avec bande d clairage vers le haut LIRE ATTENTIVEMENT AVANT L INSTALLATION CONSERVER CES INSTRUCTIONS POUR UTILISATION ULT RIEURE A AVERTISSEMENT Risque de commotion e Coupezl alimentationsecteur avanttoute intervention Reportez vous aux instructions GENERALITES Ce luminaire est con u pour des applications montage coll ou pendant au plafond dans un garage
4. GEH 5971B INSTRUCTIONS Garage Guardian Garage Luminaire with Uplight Band GE Lighting Solutions READ THOROUGHLY BEFORE INSTALLING SAVE THESE INSTRUCTIONS FOR FUTURE USE A WARNING Risk of electric shock e Turn power off before servicing see instructions GENERAL This luminaire is designed for pendant or ceiling mounting applications in a garage and should be installed and maintained according to the following recommendations UNPACKING This luminaire has been properly packed so that no parts should have been damaged during transit Inspect to confirm The carton should contain a luminaire complete with mounting assembly and the lamp installed in the socket medium base version only B Rigid Pendant Mounting 1 Loosen three lens screws and remove refractor and refractor ring from luminaire housing INSTALLATION 2 Loosen reflector screws remove reflector Remove nomex wire shield 3 Thread pendant conduit into top housing Figure 4 or mounting hub Figure 6 and tighten lock nut A N 4 Feed wires through pendant and extend approximately 6 inches of wire into housing and make necessary connections See Wiring section Connect supply ground lead to the luminaire green lead Unit will fall if not installed properly e Follow installation instructions WARNING By Use By User Risk of fire e Keep combustible materials away from lens see instructions e Use lamps specified on nameplate
5. Te sini GEN 2 ERAL G etecraie EAT NO Tue ATTENTION 2 Passez les fils d alimentation par le conduit dans le bo tier d accouplement R alisez les Risque de br lure a connexions e Laissezl ampouleetl appareilrefroidir avanttoute 3 Faites glisser l extrusion fix e au luminaire compl tement dans l extrusion de la suspension manutention Remettez la plaque de couvercle La plaque de couvercle est n cessaire pour bloquer le luminaire en place sur le dispositif recouvrir les connexions lectriques et si c est la configuration isoler l unit de l eau Figure 7 Figure 8 Figure 9 CABLAGE AVERTISSEMENT R alisez toutes les connexions lectriques en conformit avec la norme nationale am ricaine ou toute r glementation locale applicable Risque de br lure e Netouchez pas unluminaire allum V rifiez que le secteur d alimentation a la bonne tension indiqu e sur la plaque signal tique Pour les montages en suspension pendante rigide ou flexible les connexions d alimentation du client doivent arriver au dessus de l cran maille Nomex R f rence B Montage suspendu rigide au plafond paragraphes 2 et 5 Nettoyage Il sera de temps en temps n cessaire de nettoyer le r flecteur afin de conserver l apparence et le niveau d clairage La fr quence des nettoyages d pendra du niveau de poussi re ambiant et du niveau d clairage minimum tol rable Le r fracteur et le carter APPAREIL MONOTENSION
6. ctions de fonctionnement de son fabricant en particulier concernant type de ballast position d allumage etc Remplacez imm diatement les ampoules grill es ou noircies Serrage d ampoule Culot Mogul L ampoule doit tre bien ins r e au couple de serrage sp cifi NEMA EEI de 35 pied livres ce qui s obtient en serrant tr s fermement la main Le serrage doit tre suffisant pour bien enfoncer et charger le contact central de la douille Serrage d ampoule Culot moyen L ampoule doit tre serr e avec une fermet mod r e suffisante pour enfoncer le contact central de la douille Quartz commut Les unit s quip es pour ce type de fonctionnement auront leur douille install e dans le d flecteur Il suffit d y installer une ampoule quartz GE Lighting Solutions 1 888 MY GE LED e www gelightingsolutions com 1 888 69 43 533 GE Lighting Solutions is a subsidiary of the General Electric Company Evolve and other trademarks belong to GE Lighting Solutions The GE brand and logo are trademarks of the General Electric Company 2011 GE Lighting Solutions Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 35 201578 163 3 08
7. e Maintain minimum 3 below luminaire 6 Inches 152mm Cover Figure 4 If unit is multi volt see Wiring Section Luminaire Mountings A Ceiling Mounting 1 Attach mounting plate to electrical junction box and pullincoming powerleads through oval hole in mounting plate 2 Suspend luminaire below j box and attach wireform by squeezing legs together slightly and inserting through rectangular j box mounting plate holes 3 With luminaire hanging below j box make electrical connections and place wires into j box Figure 1 4 Swing luminaire into place mate two mounting plates and slide together until plates lock into place Figure 2 5 To remove fixture from j box luminaire must be opened by loosening three lens screws then loosening reflector screws and removing reflector The locking screw must be backed out approximately one half inch Figure 3 Figure5 Mounting Wireform Plates 5 Route incoming supply conductors through wire clip D Figure 5 provided Re attach nomex shield 6 Reassemble luminaire Figu rel C Flexible Pendant Mounting 1 Follow procedure for rigid pendant mounting B1 B6 2 If adjustment is needed to balance luminaire and have conduit hang vertical loosen the four screws in the slotted holes slide the mounting hub until luminaire hangs straight re tighten screws Use widest bolt spacing possible to secure hub to cover Junction Box
8. et doit tre mont et entretenu en respectant les recommandations qui suivent D BALLAGE Ce luminaire a t correctement emball de fa on ce qu aucune de ses parties n ait t endommag e durant le transport Inspectez le pour confirmation Le carton doit contenir un luminaire au complet avec ensemble de montage et ampoule install e dans sa douille version culot moyen seulement INSTALLATION ATTENTION L unit peut tomber si elle est mal install e e Suivezlesinstructions d installation AVERTISSEMENT Risque de d part d incendie e Gardezles mat riaux combustibles l cart de la lentille Reportez vous aux instructions e Utilisezdes ampoules sp cifi es surla plaque signal tique e Maintenezunespacelibre d au moins 90 cm sous le luminaire Si l unit est multi tensions consultez la section sur le c blage Montages du luminaire A Montage contrele plafond 1 Fixez la plaque de montage au bo tier de raccordement lectrique et tirez les fils d arriv e d alimentation par le trou ovale dans la plaque de montage 2 Suspendez le luminaire sous le bo tier de raccordement et fixez le Wireform en pressant l g rement les pattes ensemble et en les ins rant au travers des trous de plaque de montage du bo tier de raccordement 3 Avec le luminaire pendant sous le bo tier de raccordement r alisez les connexions lectriques et ramenez les fils dans le bo tier Figure 1 4 Basculez le lum
9. he Nomex Wire Shield Reference B Rigid Pendant Mounting Note 2 and 5 IF SINGLE VOLTAGE All single voltage wattage ballasts are pre wired such that user need only connect supply conductors IF MULTIVOLT 120 208 240 277 Units are pre wired for 277 To change voltage of unit to a voltage other 277 volts Disconnect incoming power lead from 277 volt ballast lead Insulate the end of the 277 volt ballast lead Reconnect incoming power lead to the ballast lead marked with the correct voltage Incoming power lead should be stripped back 3 8 and firmly inserted in the plastic termination block on the desired voltage ballast lead LAMPS Use only lamps specified on nameplate Observe lamp manufacturer s recommendations and restrictions on lamp operation particularly ballast type burning position etc Lamp Tightness Mogul Base Lamp Lamp should be securely inserted to the NEMA EEI specified torque of 35 inch pounds which is best achieved by very firmly tightening to insure application of sufficient torque Tightening must be sufficient to fully depress and load the center contact of the socket Lamp Tightness Medium Base Lamp Lamp should be tightened to a light firmness sufficient to depress the center contact of the socket Switched Quartz Units equipped for switched quartz operation will have the socket installed in the reflector Install quartz lamp o 10 Inches 254 mm Bird Shield Wireform Figure
10. inaire en place appairez deux plaques de montage et glissez les ensemble jusqu leur verrouillage en place Figure 2 5 Pour enlever le luminaire du bo tier de raccordement il fait l ouvrir en desserrant les vis de lentille puis en desserrant les vis de r flecteur et en tant le r flecteur La vis de blocage doit tre sortie d environ 1 3 cm Figure 3 Plaques de montage Wireform Figure 1 Vis de blocage Bo tier de fis raccordement y rw de montage eS SC r Figure 2 LE Montage suspendu rigide au plafond 1 Desserrez les trois vis de lentille et 6tez le r fracteur et son anneau du carter du luminaire 2 Desserrez les vis de d flecteur tez le d flecteur Enlevez l cran en maille Nomex 3 Vissez le conduit de suspension dans le haut du carter Figure 4 ou le moyeu de montage Figure 6 et serrez l crou de blocage 4 Passez les fils dans le conduit de suspension et sortez les d environ 15 cm dans le carter puis r alisez les connexions n cessaires voir la section sur le c blage Branchez le fil de terre de l arriv e d alimentation sur le fil vert du luminaire crou de blocage par utilisateur 6 pouces 152 mm Couvercle Figure 4 Connecteurs Serre fils Fil de terre Figure 5 5 Faites passer les fils d arriv e d alimentation dans le serre fils D Figure 5 fourni Fixez nouveau l cran en Nomex 6 Remontez le luminaire Mo
11. ntage suspendu flexible au plafond 1 Suivez la m me proc dure que pour le montage suspendu rigide B1 B6 2 Si un r glage est n cessaire pour quilibrer le luminaire et que le conduit pende bien verticalement desserrez les quatre vis dans les trous allong s glissez le moyeu de montage jusqu ce que le luminaire pende droit et resserrez ces vis Utilisez l espacement de boulons le plus grand possible pour fixer le moyeu sur le couvercle Ces instructions n ont pas pour destination de couvrir tous les d tails ou variantes de l quipement ni de r pondre toutes les ventualit s que vous pourriez rencontrer pendant l installation le fonctionnement ou l entretien Si vous souhaitez des informations compl mentaires ou si vous rencontrez un probl me particulier qui ne soit pas adress de votre point de vue d acheteur le sujet doit tre remont jusqu la soci t GE Lighting Solutions o Vis 6 pouces 152 mm Joint Li N CES 10 pouces 254 mm Figure 6 Couvercle i Ecrananti oiseaux D Luminaires avec accouplement d alimentation dispositifs de suspension sur bo tier lectrique en Figure 7 pendant rigide en Figure 8 et pendant flexible en Figure 9 1 Enlevez la les plaque s de couverture et fixez le dispositif de conduit de suspension puis serrez les vis de fixation Wireform Couvercle Figure 10 ENER 6 CAT NO Fon Power AL etectaic it sg 5 conn SEE MODULE WaMepig

Download Pdf Manuals

image

Related Search

Related Contents

Product Manual - Pro Water Treatment  Audiovox FRS-3000PK Two  Sanus Systems VMF408  Korg EASYSTART D32XD User's Manual  Dehumidifier Service and Parts Manual  2000-2001 ZagNet User`s Manual  South Shore Furniture 3170043 Instructions / Assembly  Hotpoint HS1621 refrigerator  World Marketing of America ELCG240 fireplace  

Copyright © All rights reserved.
Failed to retrieve file