1. GE Installation Guide Lighting Albeo LED Luminaire Linear Lighting ALC3 Series E BEFORE YOU BEGIN Read these instructions completely and carefully WARNING AVERTISSEMENT RISK OF ELECTRIC SHOCK RISQUES DE D CHARGES LECTRIQUES e Turn power off before inspection installation or removal e Coupez l alimentation avant d inspecter installer ou d placer le luminaire e Properly ground electrical enclosure e Assurez vous de correctement mettre la terre le bo tier d alimentation lectrique RISK OF FIRE RISQUES D INCENDIE e Follow all NEC and local codes e Respectez tous les codes NEC et codes locaux e Use only UL or IEC approved wire for input output connections e N utilisez que des fils approuv s par UL ou IEC pour les entr es sorties de Minimum size 18 AWG connexion Taille minimum 18 AWG This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CAN ICES 3 A NMB 3 A This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed o provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate ra
2. Rod Mount Kit Materials Required e 3 8 threaded rod Qty 2 e 3 8 nuts Qty 4 e Rod Mount Kit T Attach to structural member Attach all rod mount brackets to fixture end plates Secure 3 8 threaded rods into structural members in the using screws and lock washers supplied in the Rod ceiling Place a nut on each threaded rod where fixture Mount Kit should hang Slide fixture onto threaded rods and place second nut on to threaded rods to secure fixture in place Assure that the fixture is secure and cannot come free of mounting means GE Lighting 1 888 MY GE LED 1 888 69 43 533 www gelighting com The GE brand logo and Albeo are trademarks of the General Electric Company 2014 GE Lighting LLC Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions ALB008 030714
3. dio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Save These Instructions Use only in the manner intended by the manufacturer If you have any questions contact the manufacturer Prepare Electrical Wiring Tools and Components Required Electrical Requirements e ALC3 Series fixture eal e The LED driver must be supplied with 120 277 VAC 50 60 e Chain or cable 80 Ibs minimum load rated Hz per product label and connected to an individual properly or RodMount kit grounded branch circuit protected by a 15 or 20 ampere Cord Install circuit breaker e SJO or SJOW cable f e UL Listed strain relief s Grounding instructions Hubbell SECSO strain relief or e The grounding and bonding of the overall system shall be UL listed equivalent done in accordance with National Electric Code NEC Article Conduit Install e 1 2 trade size flexible conduit e 1 2 trade size conduit 600 and local codes imagination at work Electrical Connections 1 Carefully unpack unit and properly inspect for defects For safety turn off main power before installation of before installing Wear work gloves to prevent dirt and fixture oil from being t
4. ransferred to the luminaire A Conduit B Power cord Conduit B Power cord Option 1 power input from side Remove knockout in Option 2 power input from top A Install 1 2 conduit endcap and A Install 1 2 conduit or B install AC power or B install AC power cord with strain relief cord with strain relief Plug unused hole on top with appropriate fitting Assuming Option 2 was chosen in previous step remove Connect the green ground black line and white access panel to reach power supply wiring neutral wires of the AC line to the similarly colored wires of the fixture s power supply using UL listed wire connectors Re attach access panel Restore main power Mounting Options Please follow all UL NEC and minimum load rating guidelines when selecting and installing a chain cable or rod ola Cable or Chain Hang two chains cables rated to support a minimum load of 80 Ibs from a structural member of the ceiling Fixture must be supported independently of an outlet box NOTE When selecting chain a joint in a Attach to Attach to circular chain link shall be welded A joint structural member structural member in a chain link of another shape shall not be located within 30 degrees of the vertical unless welded Attach chain or cable to mounting holes on the end plates at both ends of the fixture Assure that the fixture is secure and cannot come free of mounting means 0 aie N

Download Pdf Manuals

image

Related Search

Related Contents

Instrucciones de usuario  Téléchargement de la mode d`emploi bref!  G1595_Longe sangle  TAFCO WINDOWS NU2-067V-W Instructions / Assembly  Cirago IPA1200 USB cable  MegaVox Pro User Manual    Sennheiser MM 30i  Minivandal Day/Night IR COLOR DOME CAMERA  Office 1600/1600IP  

Copyright © All rights reserved.
Failed to retrieve file