Home
Gaggenau AH 530-790 User's Manual
Contents
1. 10 1 2 66 3 15 m 3 Operation The AH 530 790 is 35 s 90 cm wide and the AH 330 720 is 47 16 120 cm wide Operation of both extractor hoods is identical After they have been pressed all functions selection keys except 0 Motor off are backlit in green Light The lighting can be switched on or off regardless of whether the wall extractor is in operation by pressing the key see Fig 4 When you briefly press the key the lighting is increased up to the maximum level You can dim the lighting to the required level by keeping the key pressed Fan levels Three fan speeds and one intensive speed are available see Fig 5 You set the fan level required for each respective cooking situation by pressing the function selector keys 1 2 3 or Int The Int key for the intensive level should be pressed when browning and frying in an open pan see Fig 6 If you have switched on the hood by selecting the intensive level it will be switched off again automatically after 5 minutes If you press the Int key while the hood is running at fan level 1 2 or 3 the electronic control will switch back automatically to the previously selected fan level after 5 minutes See Fig 7 If you would like to end the intensive level before the five minutes have elapsed press the 0 key Motor off or select a different level see Fig 8 You can of course switch off the hood s extraction
2. 3 The grease filter can of course be cleaned at any time even if the grease filter saturation display should not start to flash The stainless steel grease filters can be removed easily for cleaning see Fig 13 Grip the grease filter handle and push the slide towards the rear Then pull the grease filter downwards out of the holder repeat the operation for the other grease filters You can clean the stainless steel grease filters ina dishwasher at a maximum temperature of 150 F 65 C where it should be supported vertically to allow food or rinsing residues to drain off The inner parts of the housing should be wiped out with hot rinsing water when replacing the filters Note When cleaning the inside of the housing avoid protruding parts After having cleaned them re insert the grease filters in the hood in reverse order Important The handles of the grease filters must be visible after assembly Press the F key to set the elapsed hours counter to zero Flashing of the indicating lamp goes off OOOO O O Cleaning the extractor hood Clean the extractor hood and the aluminium design ventilation ducts LK 530 011 021 witha soft cloth and mild detergent solution only Clean the stainless steel design ventilation ducts LK 530 010 020 with mild detergent solution and apply stainless steel care agent to the metal s
3. all the things your extractor hood is capable of doing and how the appliance is operated Tips and hints in the chapter entitled Cleaning and care will make sure that your appliance will stay operable and beautiful for a long time And now we wish you lots of fun with your new extractor hood pafety notes Read And Save These Instructions WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer b Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel CAUTION FOR GENERAL VENTILATION USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings b Always turn hood ON when cooking at high heat or when cooking flaming foods c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropri
4. function at any time by pressing the 0 key Motor off Special functions Intensive time You can set the intensive level running time to 3 5 or 10 minutes by simultaneously pressing the Int key and the 1 2 or 3 key and you can store this setting see Fig 9 When delivered the appliance is set to five minutes 1 e the combination of the Int key and the key 2 Delayed shut off Delayed shut off is possible at any level First press the required key 1 2 3 or Int and then press the key see Fig 10 The delayed shut off time for all levels is ten minutes After these ten minutes the ventilation switches off but the lighting stays on Interval ventilation Interval ventilation is a special feature of this appliance which periodically activates the fan for five minutes every hour You can activate this function by simultaneously pressing the 0 key and depending on the required extraction capacity the 1 2 or 3 key see Fig 11 This mode of operation is indicated by alternating illumination of the key together with the corresponding fan level indicator You can switch off interval ventilation by pressing the 0 key see Fig 12 4 Cleaning and care 00000000 10 Cleaning the grease filters The grease filter saturation display F flashes after an operating time of 30 hours to indicate that you should clean the grease filter see Fig
5. AH 530 190 AH 530 120 Preface Safety notes 1 Important notes 1 1 For your safety 1 2 Operating for the first time 1 3 About use 2 Features 3 Operation 4 Cleaning and care 5 Maintenance 6 Assembly instructions 6 1 Technical data 6 2 Installation Page 3 Page 4 5 Page 4 Page 5 Page 5 Page 6 Page 7 9 Page 10 11 Page 12 Page 13 17 Page 13 Page 14 17 Preface 00000000 With your new extractor hood working in the kitchen will be even more fun The appliance offers you a number of advantages A good extraction capacity with low noise values a large number of control functions optimum illumination of the cooking surface by a dimmable halogen light To ensure that you will be able to use this appli ance in all its diversity read through the operating and assembly instructions conscientiously before operating it for the first time The instructions contain important notes on use installation and maintenance of the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting value of your appliance You will find notes on Page 4 that you ought to observe before operating the appliance for the first time The chapters entitled Features and Operation will tell you
6. appliance to the user with refe rence to the operating instructions He must explain to the user how the appliance can be isolated from the mains whenever required Connection possibilities It must be possible to isolate all poles of the appliance from the mains by way of the domestic fuse or by means of accessible isolating device with a contact gap of at least 3 mm 13 6 2 Installation WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction b Sufficient air is needed for proper combustion end exhausting of gases through the flue chimney of fuel buming equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American society for Heating Refrigeration and Air Conditioning ASHRAE and the local code authorities c When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities d Ducted fans must always be vented to the outdoors e If this unit is to be installed over a tub or shower it must be marked as appropriate for the appli cation and be connected to a GFCI Ground Fault Circuit Interrupter protected branch ci
7. ate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be bumed c DO NOT USE WATER including wet dishcloth or towels a violent steam explosion will result d Use an extinguisher ONLY if 1 You know you have Class ABC extinguisher and you already know how to operate it 2 Lhe fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit 1 Important notes 1 1 For your safety Damaged appliances must not be operated The appliance must only be connected by an authorised specialist paying attention to the relevant regulations of the power supply companies and the regional construction regulations Also observe the assembly instructions Connecting cables must not come into contact with hot cooking surfaces Do not operate the extractor hood without inserted lamps Never operate the appliance without a grease filter Hazardous or explosive substances and vapours must not be extracted The user 1s responsible for expert use and the perfect condition of the appliance On
8. d does not exceed 4 Pa 0 04 mbar This can be achieved whenever the alr needed for combustion 1s able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or other technical means If the appliance is to be operated only with the window open to ensure adequate incoming air you can use the window switch A switch normally open is fitted on the window On the appliance this switch is connected to the window switch terminal on the main electronics The appliance can now only be operated when the window is open Important The window switch must only be connected by an authorised specialist Note The light function works without restriction After a power failure the extactor will not go on again automatically You can recommence operation by turning a knob or by pressing any key Technical modifications reserved 1 2 Operating for the first time Before operating the appliance for the first time please pay attention to the following notes The appliance must be installed and connected by a specialist before it is operated for the first time The rating plate for this appliance is included with the instructions on a separate sheet Store the rating plate in the same location as your operating and assembly instructions You need the rating plate for possible damage and warranty cases Conscientiously read through the operating and assembly instructions before o
9. e bottom from edge of the hood Using the drilling template drill the 6 holes for the hood area I of the drilling template and the two holes for suspending the chimney area II of the drilling template In the top two securing holes for the hood fix the two hooks d with the countersunk screws ce Make sure that the hooks lie flatly on the wall In certain circumstances you may have to countersink the drill holes Fit the included dowels a in the other drill holes Note Pay attention to any special accessories that you may have to fit Screw on the retaining bracket for the chimney paneling Detach the grease filters Hang the hood on the two hooks Adjust the suspended element with the recessed head screw and align the hood using a spirit level Fig 20 Secure the hood on the wall with the four screws b Fig 21 Establish the pipe connection Establish the electrical connection Stainless steel chimney only LK 530 010 020 Pull the protective film off the chimney s trims Note Avoid damaging the sensitive metal surfaces Fit the top of the chimney into the base Make sure that the fastening holes on the side are at the top Put both chimney parts onto the hood Pull the chimney top duct up into its final position and secure the top duct unit with 2 screws on the ceiling holder Fig 22 Note Avoid scratching the surface when pulling out the t
10. eiling heights of 1 3 8 67 2 20 2 66 m LK 530 020 for ceiling heights of 867 10 1 2 66 3 15 m Aluminium design ventilation duct LK 530 011 for ceiling heights of 1 3 8 67 2 20 2 66 m LK 530 021 for ceiling heights of 867 10 1 2 66 3 15 m The dimensions above refer to a distance of 5 37 1 60 m from the floor to the bottom edge of the hood If required individually sized ventilation ducts are available at an extra charge The power connection must be placed behind the duct cover on the wall ad 600 1550 24 5 1 Hood height e wis gt D lt D I D O o a 2110 16 min 600 24 over electric cooker 100 min 700 271 2 over gas cooker 1600 5 3 200 8157 2 15 1782 1 082 3j 47 3 lt min 600 24 electric 35 3 8 47 3 16 gt min 700 271 2 gas Important Before marking the securing holes make sure that no electricity or water lines or other lines are laid at the drilling points in the wall Proceed as follows From the bottom edge of the hood mark a center line on the wall With the aid of the drilling template mark the positions of the screws on the wall Fig 19 Pay attention to the minimum clearance of 24 600 mm for electric cookers and 27 2 700 mm for gas cookers The bottom edge of the template corresponds to th
11. ly ever operate the appliance under super vision Caution Over greased filters are a fire risk Only ever deep fry under the extractor under constant supervision Pay attention to cleaning the grease filter on a regular basis Fire risk Do not flamb meals under the extractor hood Operation of the extractor hood above a hearth for solid fuels coal or wood etc is only partly pemnitted Gas appliances may only be used under the extractor hood when pots and pans are placed on them When using more than 3 gas operated rings at the same time please operate the extractor hood at level 2 or higher This prevents a build up of heat in the appliance For safety reasons do not place any heavy objects on the top of the appliance Do not clean the appliance with a steam cleaning apparatus or with water pressure because this poses a risk of short circuits Isolate the appliance from the mains during every maintenance operation To do this actuate the corresponding fuse Repairs must be carried out by authorised specialists thus ensuring electrical safety No warranty claims can be lodged in the event of damage caused by failure to observe these instructions Adequate incoming air must be ensured if a wood coal gas or oil heater or an open hearth is operated in the same room as the one in which the hood is installed safe operation is possible whenever the partial vacuum in the place where the firing equipment is installe
12. op duct element for example by placing the assembly template over the edge of the bottom chimney duct to protect it Reinsert the grease filters Place the glass plates on the appliance with the printed side facing down Note When putting the glass trays in place make sure that you do not scratch the chimney 5750197383 en 11 01 SK lv Operating and assembly instructions AH 530 790 AH 530 720 Extractor hood OVYVAODMWO O GAGGENAU
13. perating the appliance for the first time Remove the packaging from the appliance and dispose of it properly Pay attention to the fact that there are accessories in the packaging Keep packaging elements out of the reach of children Thoroughly clean the appliance before using it for the first time see chapter entitled Cleaning and care Before operating the appliance for the first time check that the mains connection is in proper working order 1 3 About use The appliance is intended solely for use in the household and must not be put to any other uses In the event of malfunctions first of all check the household fuses If the problem has nothing to do with the power supply please contact your specialist dealer or your local Gaggenau after sales service Features ODOOM OOO Grease filter saturation display Lighting Run on Extraction level intensive Extraction level 3 Extraction level 2 Extraction level 1 Motor off Fig 3 1 Outgoing air duct 2 Control panel 3 Grease filter 4 Lighting Installation accessories Stainless steel design ventilation duct LK 530 010 for ceiling heights of 1 3 8 67 2 20 2 66 m LK 530 020 for ceiling heights of 867 10 1 2 66 3 15 m Aluminium design ventilation duct LK 530 011 for ceiling heights of 1 3 8 67 2 20 2 66 m LK 530 021 for ceiling heights of 867
14. rcuit f NEVER place a switch where it can be reached from a tub or shower WARNING To reduce the risk of fire use only metal ductwork 14 The applicable regulations of the energy supply companies and the regional construction regulations must be observed when installing the hood The minimum distance from the worktop to the bottom edge of the wall hood is for electrical appliances 247 600 mm and for gas appliances aL 1 2 T00 mm The wall hood was conceived for the exhaust air mode The exhaust air can be routed into a separate exhaust air shaft or directly into the open through the outside wall It is not allowed to pass the exhaust alr into a flue or exhaust air chimney that is in operation or into a shaft that is linked to the heating basement Consult the chimney sweep responsible for your district whenever you wish to pass the exhaust air into a chimney that is not in operation During the course of planning a chimney sweep must be consulted if a room alr dependent hearth is operated in the same room as the one in which a hood is operated in the exhaust air mode Adequate incoming air must be ensured The applicable construction and safety regulations must be observed Adequate incoming air must be ensured if a wood coal gas or oil heater or an open hearth is operated in the same room as the one in which the hood is installed safe operation is possible whenever the partial vacuum in the place where
15. service agent or contact Gaggenau USA on 800 828 9165 Specify the appliance type see rating plate Repairs may only be carried out by authorised technicians in order to guarantee the safety of the appliance Unauthorised tampering with the appliance will invalidate any warranty claims Only ever use original spare parts Lamp replacement Caution Disconnect the power supply before replacing lamps switch off the fuse Caution Lamps may still be hot shortly after use Risk of burns Detach the ring from the lamp cover Note Make sure that the glass will not fall out Fig 16 Pull out the lamp Fig 17 Defective lamps must only be replaced by lamps of the same type 12 V 20 W G4 lampholder Inserting the lamp Insert the lamp in the lampholder Note Do not touch the halogen lamps with your hands Use a cloth and touch the lamp only on its edges Engage the lamp cover Connect the appliance to the mains again 6 Assembly instructions 6 1 Technical data AH 530 790 Weight 23 0 Kk Dimensions 353 8 x 20 19 16 898 x 550 mm AH 530 720 Weight 21 5 K9 Dimensions 473 16 x 20 10 16 1198 x 550 mm Electrical connection Pay attention to the rating plate data The appliance must only be connected by an authorised specialist The specialist is respon sible for perfect functioning of the appliance at its installation location He must explain the operating principle of the
16. the firing equipment is installed does not exceed 4 Pa 0 04 mbar This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or other technical means Flexible aluminium pipes corrosion protected sheet metal pipes and exhaust air pipes whose material conforms to fire B1 in accordance with DIN 4102 can be used Exhaust air pipes should have a nominal diameter of 6 150 mm Pay particular attention to ensuring that the exhaust air ducts and pipes are kept as short as possible the pipes are not laid at an acute angle but as bends and that they are inserted into the shaft at an inclined upward angle and there are no cross sectional constrictions in the upward direction this reduces the volume flow As standard the blow out opening of the wall hood is In the upward direction To pass exhaust air through the outer wall we recommend the use of our telescopic wall box TM 150 045 6 150 mm Note To prevent the ingress of water e g condensate or rain water from an uncovered exhaust air shaft our condensate separator RV 060 150 must be installed in the exhaust air line The condensate separator must still be acciessible after installation The duct units listed below are available depending on the height of the ceiling Stainless steel design ventilation duct LK 530 010 for c
17. urface using a soft cloth Cleaning the glass plates Apply commercially available window cleaning agent with a soft moist cloth To facilitate cleaning you can detach the glass plates as follows Detach the grease filters Inside the extractor hood you will find three openings on the upper side through which you can lift the glass plates singly with a blunt object e g handle of a wooden spoon to detach them with greater ease If they are extremely soiled the glass plates can be cleaned in a dishwasher at a maximum temperature of 130 F 55 C Note When putting the glass trays back in place make sure that you do not scratch the chimney Cleaning the aluminium panel Clean the aluminium panel with a sponge and mild detergent solution only Wipe with a soft dry cloth Do not use any strong or caustic cleaning agents or brushes and abrasive cleaner to clean it Do not use strongly alkaline cleaning agents such as oven spray because these are aggressive to the aluminium surface Do not use any abrasive sponges either ll 5 Maintenance 12 The appliance must be disconnected from the power supply during all repair work If the appliance does not function correctly check the fuses first If the power supply is functioning correctly but your appliance still does not work please contact your Gaggenau dealer who will provide you with the address and telephone number of your nearest manufacturer s authorized
Download Pdf Manuals
Related Search
Related Contents
Dayton 2E783D User's Manual DirectLogic DL05 and DL06 PLCs Bedienungsanleitung - Besøg masterpiece.dk Pontiac 2002 Sunfire Automobile User Manual User Manual MANUAL DE USUARIO 用戶手冊 Jasco RM25001 User's Manual Ultra-Fast AA/AAA Battery Charger User`s Manual Grilles d`évaluation CAP Maintenance des Matériels : Mode d`emploi Copyright © All rights reserved.
Failed to retrieve file