Home
Fisher & Paykel OB30SDEPX2 Installation Manual
Contents
1. 1 1 1 599496B OB30Aerotech installA2 USCA indd 4 6 09 9 40 11 AM Installation instructions Aerotech oven OB30 models Fisher amp Paykel innovative living Important SAVE THESE INSTRUCTIONS The models shown in this document may not be available in all markets and are subject to change at any time For current details about model and specification availability in your country please visit our local website listed at the end of this document or contact your local Fisher amp Paykel dealer 1 SAFETY AND WARNINGS A WARNING Very Heavy A WARNING Electrical hazard Always disconnect the oven from the mains electricity supply before carrying out any maintenance operations or repairs Do not attempt to lift this product unassisted Lifting unassisted may cause serious injury Failure to do so may result in electrical shock or death SINGLE OVEN MODELS A WARNING Cut hazard Take care panel edges are sharp Failure to use caution could result in injury or cuts Important safety instructions Save these instructions for the local inspectors use To avoid hazard follow these instructions carefully before installing or using this product Please make this information available to the person installing the product as it could reduce your installation costs This oven is to be installed and connected to the electricity supply only by an authorized person If the installation re
2. to the oven Make sure the voltage is correct across all phases If a problem occurs consult the Troubleshooting section of the User Guide If after checking these points you still need assistance or parts please refer to the Service amp Warranty book for warranty details and your nearest Authorized Service Center or contact us through our local website listed below www fisherpaykel com www fisherpaykel ca 599496B USCA 06 09
3. width of cabinetry J inside height of cavity J overall height of cabinetry K minimum inside depth of cavity sjapow S 0E gO 27 Vie 688 29 34 757 23 1346 608 26 34 675 28 4 718 22 e 570 1 V2 38 20 7 530 28 Y2 724 30 762 26 1346 681 27 546 693 Proud install 22 6 575 Flush install 24 Ye 613 Note If installing a cooktop above the oven ensure adequate clearance is provided for the cooktop as per the cooktop manufacturer s instructions G PRODUCT AND CABINETRY DIMENSIONS Double oven models Proud install Vg 2 5 mm Flush install e e Y 3A6 16 20 mm 17 116 20 mm _ he 2 5 mm Ensure the cavity is completely sealed with no gaps Product and cabinetry dimensions inches mm overall height of product overall width of product overall depth of product without handle height of chassis width of chassis depth of chassis depth of oven frame and control panel excl knobs depth of oven doors open measured from front of oven frame TIA TM OA WS minimum inside width of cavity overall width of cabinetry o inside height of cavity overall height of cabinetry A minimum inside depth of cavity sjapow aotgo 48 7 6 1230 29 34 757 23 6 608 47 Ae 1217 28 14 718 22 7 6 570 1 2 38 20 530 28 V2 724 30 762 48 Ve 1222
4. 48 5 1235 Proud install 22 3 575 Flush install 24 s 613 2 1 1 599496B OB30Aerotech installA2 USCA indd 4 6 09 9 40 11 AM 4 UNPACK THE OVEN AND REMOVE THE DOOR S Double models featured for illustration purposes only A Important Ensure you remove the long trim from the packaging 5 ELECTRICAL CONNECTION TO JUNCTION BOX A Junction box location ees ee m for undercounter y f installation Junction box location for wall installation AY 0B30 Single Max current draw 194A Max load 46kW OB30 Double Max current draw 38 3 A Max load 9 2 kW white and green grounding oven wires factory taped conduit connector cable from cable from power supply green grounding gt oven wires eS factory taped UL listed conduit connector Disconnect the power supply Remove the junction box cover Connect the oven cable to the junction box through the U L listed conduit connector Connect the two black wires together with twist on connectors Connect the two red wires together with twist on connectors Connect electrical connection according to local codes and ordinances If local codes permit connecting the cabinet grounding conductor to the neutral white wire in the junction box 7a Connect the factory taped green
5. and white oven cable wires to the neutral white wire in the junction box 8a Replace the junction box cover 7b 8b 9b OR If local codes DO NOT PERMIT connecting the cabinet grounding conductor to the neutral white wire in junction box Separate the factory taped green and white oven cable wires Connect the white oven cable wire to the neutral white wire in junction box Connect the green grounding oven cable wire to a grounded wire in the junction box 10bReplace the junction box cover OR If connecting to a four wire electrical system 7c Separate the green and white oven cable wires 8c Connect the white oven cable wire to the neutral white wire in junction box 9c Connect the green grounding oven cable wire to the green grounding wire in the junction box Do not connect the green grounding wire to the neutral white wire in junction box 10c Replace the junction box cover 2 2 1 599496B OB30Aerotech installA2 USCA indd 4 6 09 9 40 11 AM 6 SECURE THE OVEN TO THE CABINETRY AND REFIT THE DOOR S Take care not to damage the lower trim of the oven Ensure supplied spacer is fitted between oven and cabinetry B D FLUSH INSTALLATION ONLY REPLACE THE LOWER TRIM WITH THE SU Unscrew and remove the installed lower trim Ensure the clips on the long trim locate i
6. codes permit and a separate grounding wire is used it is recommended that a qualified electrician determine that the grounding path and wire gauge are in accordance with local codes Do not use an extension cord with this appliance When you install the oven Do not seal the oven into the cabinetry with silicone or glue This makes future servicing difficult Fisher amp Paykel will not cover the costs of removing the oven or of damage caused by this removal Use the supplied screws to secure the oven to the cabinetry Do not over tighten the screws Do not stand on the door or place heavy objects on it Do not lift the oven by the door handle Take extra care not to damage the lower trim of the oven 1 2 1 599496B OB30Aerotech installA2 USCA indd 4 6 09 9 40 11 AM PRODUCT AND CABINETRY DIMENSIONS Single oven models Installation diagrams for illustration purposes only Ve 2 5 mm Proud install Flush install 8 136 1346 16 20 mm 16 20 mm LW G C 4 _ 2 5 mm Ensure the cavity is completely sealed with no gaps Product and cabinetry dimensions inches mm overall height of product overall width of product overall depth of product without handle height of chassis width of chassis depth of chassis depth of oven frame and control panel excl knobs depth of oven door open measured from front of oven frame TUDO TM OA DS minimum inside width of cavity overall
7. nto the Replace with the supplied long trim Please turn over gt 1 1 2 599496B OB30Aerotech installA2 USCA indd 4 6 09 9 42 48 AM FINAL CHECKLIST OO 0O OOO Make sure the appliance is level and securely fitted to the cabinetry and both oven doors open and close freely Make sure all the internal packaging has been removed from the oven cavity Make sure all oven vents and openings are clear and are free of any obstruction damage Important Failure to make sure all oven vents are unobstructed may result in poor product performance Turn the power to the oven on The clock should light up and flash 12 00pm Set the clock to the current time Turn the oven function knob to Bake and the oven temperature knob to 350 F 180 C Air should blow out of the vent at the bottom of the oven Inside the oven cavity all three oven lights should come on After five minutes open the oven door and the air inside should feel warm and the top element should be glowing red Turn both the oven function knob and oven temperature knob back to OFF and repeat for the other oven if the appliance is a double model 9 TROUBLESHOOTING OOOOOO If the appliance is not functioning correctly after installation check the following Check that the circuit breaker has not tripped or the fuse blown Make sure that the electrical connections have been correctly made Make sure that power is being supplied
8. quires alterations to the domestic electrical system call a qualified electrician The electrician should also check that the socket cable section is suitable for the electricity drawn by the oven The oven must be grounded To connect the oven to the mains do not use adapters reducers or branching devices as they can cause overheating and burning Installation must comply with your local building and electricity regulations Failure to install the oven correctly could invalidate any warranty or liability claims Before you install the oven please make sure that The oven will rest on a surface that can support its weight The countertop and oven cavity are square and level and are the required dimensions The height from the floor suits the user The oven door can open fully without obstruction Electrical requirements Connect oven with copper wire only Do not cut the conduit A ULL listed conduit connector must be provided at the junction box Do not ground to a gas pipe Do not have a fuse in the grounding or neutral circuit Fuse both sides of the line A time delay fuse or circuit breaker is recommended If using a time delay fuse then fuse both sides of the line Flexible armored cable from the appliance should be connected directly to the junction box Connect directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable with grounding wire If
Download Pdf Manuals
Related Search
Related Contents
ATTO ATTO GBC ClickBind 15 Mustek VDC-300 Camcorder User Manual SPARC T5-8 Server Service Manual Samsung T24B750EW Manual de Usuario Head-End Digital Transmodulator 2 x DVB-C2/T2 700IP-I2 User Manual - Smart Bus Home Automation Control HTD-710SF MP Jolie Manual de instruções para o usuário Internal Kick-Off Meeting Réunion de lancement interne Copyright © All rights reserved.
Failed to retrieve file