Home
Extron electronic Extron Electronics TV Mount WMK 100 User's Manual
Contents
1. safely routed to the electrical outlet and switcher alike c Re attach the plate to the wall and secure firmly 2 4 40 x 1 4 screws Figure 5 Attach switcher and power supply to base plate 3 Run cables Run signal cables from the proposed PoleVault input wall plates control device location and the speakers to the WMK 100 location Cables can be routed behind the walls or through a surface raceway e g Wiremold 700 or 2400 series directly to the WMK 100 3A If running cable behind the walls i Runall the cables from the various locations to the WMK and through the access hole 3B If using a surface raceway i Attach the WMK cover to the base plate then identify and mark the most suitable raceway entrance to the WMK 100 ii Run the raceway from the signal source speaker and display locations to the marked raceway entrance at the WMK iii Remove the WMK cover and remove the desired knockout iv Attach the raceway to the wall and run cables from the sources and outputs through the raceway to the WMK Signal Cable Access Cutout Option Figure 6 Cabling run options 4 Cable the switcher a Connect the cables from the PoleVault transmitters control device MediaLink Controller speakers and optional accessories VoiceLift
2. to display MLC Wire Colors PVS Switcher A Rx White A Tx B TX Violet B Rx Ground Drain Wire D Ground PVT CVD Ground Black D Ground x 12V In Red E 12 V Cabling the switcher WMK 100 Installation Notes cont d 5 Final installation a After completion of cabling place the cover over the installed plate and secure at each corner with the provided 6 32 button head screws Noyes Ensure any cables exiting the box e g to display device and external electrical outlet pass through a raceway knockout b Switch on the display device control device signal sources and adjust and configure the system as needed For full configuration and setup details refer to the PoleVault System Installation Manual the MLC 104 Plus Series Reference Manual and the PVS 305SA User s Manual all available online at www extron com General Specifications Mounting Wall Mount iccissscvteteominee Yes with included hardware Figure 7 Attach WMK 100 cover Maximum load capacity 15 lbs 6 8 kg Materialien Steel Dimensions Dabe Plate epia 12 8 H x 12 8 W x 0 5 D 32 5 cm H x 32 5 cm W x 1 3 cm D COVE an 13 0 H x 13 0 W x 2 5 D 33 0 cm H x 33 0 cm W x 6 4 cm D Product weight oriseiiiiueisinen 4 lbs 1 8 kg Shipping weight ees 6 lbs 3 kg VOTA ON siseosas ISTA 1A in carton Internati
3. Page Sensor Kit to the rear ports of the switcher see below Refer to the PVS 305SA Setup Guide for additional details Noi f using a device other than a PVS 305SA e g PVS 204SA Plus refer to that device s user manual for details b Run VGA and composite video cables from the switcher to the output display device through the wall or where fitted the raceway c Connect the power supply to the switcher and plug it in to the electrical outlet NO Lf the electrical outlet is outside the WMK pass the IEC power cable out through one of the raceway knockouts Audio output to speakers Line out output 4 audio RGB signal input 2 CAT 5 cables A and B left and right with RJ 45 Bi el Positive Negative C ous ion AUDIO VIDEO LISTED APPARATUS PVT RGB D Plus VOICELIFT Power o o o o o m OuIFUTS VIDEO T Connector cs 5 o go a poo Op A Ge AA AAA AAAA External 12V 1B RGB AUX Lh PAG RS 232 MLC IR Power Supply 5A MAX 2 AVIDEO INPUT 5 SENSOR TT 12 VDC 5 A max Se N aT oe A mi lll RS 232 Control Composite video input CAT 5 cable with VGA RCA RJ 45 connector Connector Connector 0 Aux Audio 4 Input 5 RGB output VoiceLift to display 4 Receiver t aa Ta Composite eo video output Transmit Tx A
4. existing electrical outlet v At this time lightly tighten all the screws to secure the plate to the wall and verify level and position Nop Do not over tighten as the plate needs to be removed to attach the switcher and power supply before cabling Figure 2 Masonry wall mounting 68 1738 01 Proceed to Step 2 Rev A 06 09 1 WMK 100 Installation Notes cont d 1B To mount the WMK 100 onto a non masonry wall WMK 100 Mounting Cutout for Werker tar i At the desired site locate the wall studs and mark their Pase Plate Holes Signal Cable Level Pilot Hole Access locations E e m 4 Noi For ideal installation secure the base plate to at least one Af i i i i wall stud see figure 3 Drywall Kap toggles can be used r for holes not aligned with studs o The base plate can be installed over an existing electrical outlet The opening fits standard sized 2 75 x 4 5 wall plates See inset on figure 2 ii Hold and level the base plate against the wall and mark the positions of the slotted mounting holes that are on the stud lines see figure 3 indicated by marks Where applicable mark the mounting holes on the wall for drywall toggles Set the plate aside iii Drill 1 75 4 4 cm deep pilot holes at the marked locations Cutout for Electrical L Outlet iv Insert the self tapping screws into the pilot holes until a gap of 1 8 to 3 8 3 to 9 mm rema
5. ins between the wall and the screw heads ETA f using toggle assemblies see figure 4 for installation f 8 1088 fig fi a Grasp handle collapse b Slide plastic washer method toggle and insert into wall down into pilot hole Figure 3 Non masonry wall mounting v Align the base plate s slotted mounting holes 6 l over the installed screws then slide the plate down so the screws fit into the slots vi At this time lightly tighten all the screws to ensure plate c Cut off handle close to wall d Hand screw in pan head fits flush to the wall and verify level and position porate ga ean No Do not over tighten as the plate needs to be removed to attach the switcher and power supply before cabling vii If the cables are to be run behind the wall to the WMK location mark the cutout area on the wall for the signal Figure 4 Toggle assembly installation cable access hole see figure 3 Vili Remove the base plate and cut out the marked area 2 Mount the switcher and power supply a Remove the WMK 100 base plate from the wall and with the switcher s rear ports facing the cable access hole align the two corner holes in the base of the switcher with the two outermost device mounting holes in the WMK 100 base plate Secure with the supplied 440 x 14 screws b Attach the power supply above the electrical outlet cutout with the supplied hook and loop straps Attach it so the cables are easily and
6. of Q Ora cA Extron Electronics INTERFACING SWITCHING AND CONTROL eyo WMK 100 Installation Notes The Extron WMK 100 Wall Mounting Kit is used for hanging PoleVault System A V products on a wall near a flat screen display or short throw projector The WMK 100 has a 13 x 13 x 2 5 deep enclosure to mount the PoleVault switcher and the power supply with room for cable management It also has knockouts on all four sides which allow external raceways to be used where necessary for cabling 4 1 4 20 x 2 op NU Maximum load for the WMK 100 is 15 Ibs 7 kg 037501 The key components base plate and cover of the WMK 100 are shown in figure 1 Included in the kit are 4 14 20 x 2 pan head bolts 4 4 Kap toggle assemblies 4 1 4 x 1 masonry screws 4 14 x 1 self tapping metal wood screws 4 6 32 x 1 4 button head hex screws Not shown but included are 3 4 40 x 1 4 screws 2 hook and loop 4 1 4 Kap Toggle Assemblies 40 374 01 4 1 4 x 1 3 4 Masonry Screws 40 373 01 4 14 x 1 3 4 Self tapping Metal Wood Screws straps 40 372 01 F 4 6 32 x 1 4 Button Head Hex Screws 40 363 17LF Installation Figure 1 WMK 100 parts Moli Refer to local building standards and codes to verify that the installation will meet the regulatory requirements Obse
7. onal Safe Transit Association Regulatory compliance O eee c UL UL Warranty sesrcisesnna inatin 3 years parts and labor NOTE Specifications are subject to change without notice 12 83 13 32 59cm __ 33 02 cm Side View Side View les Both Sides 12 83 a p 13 32 59 cm 33 02 cm Base Extron USA West Extron USA East Extron Europe Extron Asia Extron Japan Extron China Extron Middle East Headquarters i 800 633 9876 800 3987 6673 800 7339 8766 81 3 3511 7655 400 883 1568 971 4 2991800 800 633 9876 Inside USA Canada Only Inside Europe Only Inside Asia Only 81 3 3511 7656 FAX Inside China Only 971 4 2991880 FAX Inside USA Canada Only 1 919 863 1794 31 33 453 4040 65 6383 4400 86 21 3760 1568 1 714 491 1500 1 919 863 1797 FAX 31 33 453 4050 FAX 65 6383 4664 FAX 86 21 3760 1566 FAX 1 714 491 1517 FAX r 2009 Extron Electronics All rights reserved
8. rve all local and national building and safety codes UL requirements and ADA accessibility guidelines Before installation identify the type of wall masonry or non masonry and the location where the WMK 100 will be installed This determines the installation approach and the type of fasteners needed to secure the plate to the wall 1 Mount the base plate Follow the steps within 1A or 1B below as applicable A D Ung u Marker for Base Plate Holes Signal Cable Level Pilot Hole The base plate can be installed over an existing electrical outlet The opening fits standard sized 2 75 x 4 5 wall plates See figure 2 inset 1A To mount the WMK 100 onto masonry walls CCess i Hold the base against the wall level it and mark the positions of four slotted mounting holes indicated by marks in figure 2 Set the plate aside Nozi Use the top slot position at each mounting hole Do not use both top and left slots as this will make it difficult to slide the plate down see step 1v ii Using a masonry drill bit drill 1 75 4 4 cm deep pilot holes at the marked locations iii Screw in masonry screws until a gap of 1 8 to 3 8 Cuim tior 3 to 9 mm remains between the wall and the screw heads Electrical Outlet iv Align the base plate s slotted mounting holes over i D the installed screws then slide the plate down so h fit i he slots eee wor The plate can be aligned over an