Home

Extron electronic 305SA User's Manual

image

Contents

1. Introduction FCC Class B Notice This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that the interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV
2. Warning Power sources e This equipment should be operated only from the power source indicated on the product This equipment is intended to be used with a main power system with a grounded neutral conductor The third grounding pin is a safety feature do not attempt to bypass or disable it Power disconnection e To remove power from the equipment safely remove all power cords from the rear of the equipment or the desktop power module if detachable or from the power source receptacle wall plug Power cord protection e Power cords should be routed so that they are not likely to be stepped on or pinched by items placed upon or against them Servicing e Refer all servicing to qualified service personnel There are no user serviceable parts inside To prevent the risk of shock do not attempt to service this equipment yourself because opening or removing covers may expose you to dangerous voltage or other hazards Slots and openings e If the equipment has slots or holes in the enclosure these are provided to prevent overheating of sensitive components inside These openings must never be blocked by other objects Lithium battery e There is a danger of explosion if battery is incorrectly replaced Replace it only with the same or equivalent type recommended by the manufacturer Dispose of u
3. 5 VDC 0 10 A for PVT CV D 5 VDC 0 15 A for PVT RGB D Temperature humidity Storage 40 to 158 F 40 to 70 C 10 to 90 noncondensing Operating 32 to 122 F 0 to 50 C 10 to 90 noncondensing legt Wall or furniture mountable with included Decora wall plate PHClOSULE ty De aceon Plastic Enclosure drmensionz PVT CV and PVT RGB D Plus Faceplate 2 8 H x 1 6 W x 0 2 D 7 1 cm H x 4 1 cm W x 0 5 cm D fits the opening in a 1 gang Decora plate Device 2 7 H x 1 7 W x 1 4 D 6 9 cm H x 4 3 cm W x 3 6 cm D Depth excludes connectors height excludes mounting tabs PVT RGB D Faceplate 2 6 H x 1 3 W x 0 3 D 6 6 cm H x 3 3 cm W x 0 7 cm D fits the opening in a 1 gang Decora plate Device 2 6 H x 1 6 W x 0 7 D 6 6 cm H x 4 1 cm W x 1 8 cm D Depth excludes connectors height excludes mounting tabs Product weight 0 2 Ibs 0 1 kg WIAD TALON E ISTA 1A in carton International Safe Transit Association Regulatory compliance SE CE c UL UL E HE LEE CE C tick FCC Class A ICES VCCI RN DEE 30 000 hours de All nominal levels are at 10 Lait Specifications are subject to change without notice PoleVault Systems Installation e Reference Information 4 2 Reference Information cont d Extron PCM 340 Projector Drop Ceiling Mount 2 including Slotted Projector Mount Pole j weight 4 5 Ibs 2 0 kg Extron PMK 550 p e Easy Installation Be ow
4. c Using the X and Y dimensions mark and cut a hole for the slotted pipe in the ceiling tile Place the tile on a box and mark the hole s center on the underside of the tile Use a hole saw bit to start to cut the hole by hand turning bit counter clockwise to avoid damaging the tile When the drill bit is through the tile turn the tile over and finish cutting from the REES top side 90 Top Side of Tile Gc Mark and start cutting the hole on the underside Finish on the top side XN A 5 Preliminary safety hardware installation a Mark and drill holes at 10 degrees out from vertical for each turnbuckle Drill a fifth hole directly centered above the PCM 340 for the safety cable b Install an appropriate anchors or lag eye bolt for the structural ceiling into each drilled hole Mark structural ceiling for lag eye bolt installation 2 5 PoleVault Systems Installation e Installation Stage 1 6 Finish Projector Drop Ceiling Mount installation a Detach the projector bracket projector from the adjuster plate Do not remove the projector bracket from the projector b Unscrew the UPB 25 adapter plate from the mounting pole c Loosen the set screws on the PCM 340 and the pipe location screw and remove the mounting pole then loosen the T frame securing screws and remove the PCM 340 from its marked location d Replace the cut ceiling tile checking its orientation to
5. 800 633 9876 Inside USA Canada Only 1 714 491 1500 1 714 491 1517 FAX Outline of installation steps Stage One Install the Screen and Projector Mark the screen location page 2 3 Install projector to verify location page 2 3 Verify the image location page 2 4 Cut the ceiling tile page 2 5 Preliminary safety hardware installation page 2 5 Finish projector drop ceiling mount installation page 2 6 Secure the projector drop ceiling mount to the ceiling page 2 6 Install the electrical box if required page 2 7 EC EK E A Install the screen page 2 7 Stage Two Install the A V Source Input Wall Plates and MLC 104 IP Plus Install the mud rings page 2 10 Pull cables at the input locations page 2 11 Install the wall plates page 2 12 Install the MediaLink Controller page 2 13 Stage Three Install the FF 120 Speakers LI LI LI LI Cut the ceiling tile page 2 17 Install the speaker on the drop ceiling page 2 17 O O L Terminate the speaker cable for the PVS switcher page 2 18 Stage Four Install the PMK 550 and the PVS 305SA Install the PMK 550 base plate page 2 20 Pull the cables at the switcher location page 2 21 mimg Finish installing the pole mount kit page 2 22 Stage Five Configure the switcher and the system Configure the switcher MLS Switcher Configuration program page 2 24 Configure the system Global Configurator
6. Camera Extron VoiceLift Microphone and Charging Station Optional Accessory PoleVault System installation and wiring overview 1 2 PoleVault Systems Installation e Introduction Before you Begin Installation Planning Before installation is started several major factors must be considered to ensure that the installation process is as smooth and trouble free as possible and that the final finished project meets the needs of the customers users audiences and installer The installation consideration on the following pages though not comprehensive should be consulted to help ensure that key aspects have been considered 1 Room layout a The room The application diagram below shows a typical classroom installation Typical classroom installation Room factors to be considered should include but are not confined to e Room size orientation and layout o Audience factors e g number ADA requirements seating arrangements o Existing installed furniture bookcases racks cabinets workbenches sinks etc o Windows doors and support pillar locations in relationship to the proposed screen location e Ceiling and wall type important in assessing the installation hardware needed o Ceiling type dropped spline hard lid etc structural type wood concrete trusses plenum or non plenum o Wall type drywall cement brick etc HOT Check the structural ceiling
7. d Mount each device into the mud ring using the supplied Screws e Attach the supplied Decora faceplate PVT RGB D Plus f Label the Decora plate with the supplied label using the appropriate input number This makes inputs easier to identify when configuring the switcher g Repeat steps a f for other wall plates Mount the PVT in the mud ring then Gei attach the Decora faceplate PoleVault Systems Installation e Installation Stage 2 2 12 Installation Stage Two cont d 4 install MediaLink Controller Before cabling and installing the MLC 104 IP Plus locate and write down the MAC address of the device for configuring the IP address The 12 character alphanumeric address e g 00 05 A6 03 9G H4 can be found on a label on the side of the controller The length of exposed wire is critical to avoid transmission problems Ensure the lengths given here are adhered to when stripping the cables for connection Kat fa drain wire is used both ends of the wire must be covered by heat shrink to avoid accidental grounding a Connect the MLC power and RS 232 control cable part 26 626 50 as shown The MLC 104 IP Plus is powered from the PVS 305SA DO NOT connect an external power supply to the MLC 104 IP Plus unless installing an optional secondary control panel Wire Bared 3 16 5 mm Max Heat Shrink on Drain Wire Heat Shrink on Outer Jacket to _
8. Inner Conductor Transition Wire stripping lengths RS 232 MLC IR Tx Rx IR 412V PVS 204SA a a SG a K Switcher s rear panel ABCDE RS 232 MLC IR port From MLC 104 IP Plus Wire color To PVS 305SA terminal rr terminal y Heat Shrink A Rx on the MLS port White A Tx on the RS 232 port l SEENEN B Tx on the MLS port Violet B Rx on the RS 232 port MLS RS 232 Ground Drain wire D Ground Power Ground Black D Ground 12 V In Red E 12 V 12 VDC Ground Ground z B Receive ansmit Tx B CIA Transmit Tx Receive Rx A Se u Heat Shrink T L over Drain Wire R gt 8 8 Ka Ifyou use cable that has a drain wire tie the drain wire to ground at both ends 3155 Apply heat shrink cover to both ends of the wire to avoid accidental grounding att RS 232 12V MLC s MLS and Power ports Connecting the MLC to the switcher 2 13 PoleVault Systems Installation e Installation Stage 2 b Connect the IR RS 232 projector communication cable as shown for either RS 232 or IR projector control VIe Some projectors require NULL connection wiring which inverts the Tx and Rx connections See the projector manufacturer s manual for details c To use the MLC 104 IP Plus s IP Link feature connect a network connected CAT 5 5e or 6 straight through cable to the MLC s RJ 45 LAN jack
9. RS 232 connection Transmit Tx Receive Rx Ground Terminal RS 232 Cable color Pin RS 232 IR Tx White 2 MLC 104 IP Plus Right Side Panel Rx Violet 3 Ground Shield 5 IR connection Black IR Emitter G d a EE gt To projector Black q Unidirectional IR Output via White Striped Wire 100 ____ gt 30 5 m OUND x x lt m e e gt d i e bi DISPLAY RS 232 IR MLC 104 IP Plus Right Side Panel Terminal IR RS 232 IR Cable color Cable color Projector Ground Black Black IR Signal Red White Black Connecting RS 232 Cable Connecting IR Cable IR Emitter Projector ges White or striped lI Black ji MLC IR RS 232 aa Comm Cable Black Not Used let White Violet and Shield Not Used Shield Red Black eeglre2g25 reglre2g25 SI Sess el Ree 5 SS 5 2 Ei GB o HOST PROJECTOR HOST PROJECTOR CD dE E CONFIG RS 232 IR MLC 104 IP Plus Connect the MLC to the projector with an RS 232 cable or IR emitter cable as appropriate EZENN DO NOT connect the MLC s RJ 45 LAN jack to the PVS 305SA twisted pair inputs PoleVault Systems Installation e Installation Stage 2 CAT 5 5e or 6 Cable TCP IP Network z PRESS IAR WITH S TWEEKERTO REMOVE MLC 104 IP Plus Right Side Panel Connect to the LAN using a C
10. 2 PVT mounting screws 1 Decora Faceplate 2 Faceplate screws 1 Power supply 1 Power cord bart 8 42 109 03 and 42 110 03 contain 3 or 4 PoleVault Wallplates according to the type ordered 60 818 03 DISPLAY ON OFF VCR jl DVD VOLUME 6 PC ED i E O i Extron MLC 104 IP Plus MLC 104 IP Plus MediaLink Controller 1 Mud ring 8 Mud ring screws 8 Replacement screws 2 Faceplates 1 White on unit 1 Black FF 120 FF 120 2 Cable clamps Anchor ring 2 T rails Ia any items in the Pole Vault System boxes are damaged or missing contact the Extron Technical Hotline see rear cover for contact numbers PoleVault Systems Installation e Introduction Inventory Overview 1 7 Introduction Inventory Overview cont d b Items not included The following items are not included However input and display devices are essential parts of the system and at any installation they may vary depending on their use This list suggests various devices that may be used Projector or display device Screen and mounting hardware Input devices such as O O O DVD CD VCR combo player and cables Document camera and cables PC or Mac with keyboard mouse local monitor VGA cables RJ 45 network cables power cords and where desired a P 2 DA2 or DA for
11. Audio Mute Mute All Proarsm Mute Unmute Mic Threshold g Clip 77 er eg Ove O ad O soss Sek win id Select Help Contents and follow outes O on on z Signal Ducking Level i n stru ct 10 n e Or 6 A 6 dB High Pass Filter Enable Disable 0 dB D is D L J Output Mode Stereo O Mono Paging Sensor Mute Delay Pee oes oC OY Enabled O Dissbad 1 sec Video Settings Status Signal Status Input 1 Volume Control Module Not connected Input 2 GE de Paging Sensor Status Offline Input 3 RGB Video Input 4 RGB Video EI The PVS 305SA emulation mode screen PoleVault Systems Installation e Installation Stage 5 2 24 Installation Stage Five cont d 2 Configure the system Global Configurator a Download and install Extron s Global Configurator GC configuration program available at www extron com on the laptop or PC b Ensure the PC and the MLC 104 IP Plus are connected to the LAN If this is not possible connect a 2 5 mm TRS configuration cable part 70 335 01 to the PC and to the front panel configuration port of the MLC 104 IP Plus c Launch the Global Configurator program Click on Help then Contents or press F1 d Select the MLC 104 IP Plus PoleVault system from the drop down box Follow the instructions on the help page e To move to the next page as shown in the yellow box figure 2e click the NEXT button a
12. eu For PVT RGB D and PVT RGB D Plus wall plates two CAT 5 signal cables for each input are needed Maximum distance from the PVS 305SA to the Wall plates is 100 feet The optimum distance is between 50 and 75 feet Minimum distance is 15 feet The CAT 5 cables supplied are terminated to the TIA 568A standard Other CAT 5 cables can be used if they are TIA 568A or 568B standards and terminated to the same standard at both ends XR e CAT 5 cables not included for MLC network connection e PoleVault switcher communication cable from the MediaLink controller MLC PW RS 232 VC 50 part 26 626 50 e Projector communication cables from the MediaLink controller IR Serial Comm 50 part 26 621 50 a Drill cable pathways through any obstructions e g wall caps fire breaks or horizontal studs b Label the CAT 5 signal cables at both ends with the supplied labels c Pull the cabling through the wall from the ceiling space down to the location of the transmitters and other wall devices and out through the openings Secure cables with cable clamps to provide strain relief Trim back the outer foil shield to the point where the cable exits the cable clamp and insulate exposed cable shields with heat shrink to reduce the chance of short circuits Both braided and foil shields should be connected to an equipment ground at the other end of the cable Fasten the colored section to the cable
13. 7 Align the arrows on the housing rim and PMK 550 the dome tab Receiver Dome 9 Disconnect the power from the switcher and plug the included VoiceLift RJ 45 into the PVS 305SA s VoiceLift receiver port C le in AUDIO VIDEO LISTED APPARATUS VOICELIFT i ee RECEIVER 10 Replace power to the switcher This also powers the ee LA mF z ROESCH EEN E em em 4 aa Le i RS 232 MLC IR INPUT 5 SENSOR JOUE VoiceLift receiver VoiceLift input 9 Plug VoiceLift cable into PVS 305SA PoleVault Systems Installation e Optional Accessory Installation 3 1 Optional Accessory Installation Priority Page Sensor Kit The Priority Page Sensor Kit momentarily silences classroom audio whenever a page is made from a public address PA system For detailed information refer to the Priority Page Sensor Kit Installation Instructions supplied with the device Kai The Priority Page Sensor works with traditional 25 V or 70 V and 4 8 ohm PA systems It is not designed for and may not work properly with two way intercoms or systems that are IP based or use digital clocks Priority Page Sensor Kit included parts e Priority Page Sensor e UL compliant junction box with a cable clamp and a lid e 35 ft 10 7 m of sensor cable Installation Procedure C gt WARNING All structural steps anchoring and electrical installation should be performed by qualified personnel in ac
14. H x 15 4 W x 11 9 D 7 6 cm H x 39 1 cm W x 30 2 cm D Product Weight En 2 4 Ibs 1 2 kg Regulatory compliance SE CE c UL UL as an accessory for use with a UL Listed mount and projector ND a OI E ISTA 1A in carton International Safe Transit Association UPB 25 DAT OIG eg Steel Maximum load ssoeeeseeeeeseeeseeeseee 25 lbs 11 3 kg General dimensions Refer to UPB 25 manual PROCUMCE weit NE isos conevatsnaxousacseaneaue 3 7 lbs 1 7 kg Regulatory compliance SE CE UL c UL as an accessory for use with UL Listed mount and projector et OI E ISTA 1A in carton International Safe Transit Association Devices PVS 305SA External power supply eese 100 VAC to 240 VAC 50 60 Hz external to 12 VDC 5 A regulated Power input requirements 12 VDC 5A Temperature humidity Storage 40 to 158 F 40 to 70 C 10 to 90 noncondensing Operating 32 to 122 F 0 to 50 C 10 to 90 noncondensing e eee eee eee eee re ener Convection vents on sides Enclosure TYPE ee Metal Enclosure dimensions 0 0020 1 7 H x 8 7 W x 3 0 D 1U high half rack wide 4 3 cm H x 22 1 cm W x 7 6 cm D Product weit Mi nesciis 2 5 lbs 1 1 kg plus power supply 0 8 Ibs 0 4 kg 4 1 PoleVault Systems Installation e Reference Information Regulatory compliance SE CE c UL UL UL rated for use in plenum airspaces meets UL 2043 for heat and smoke release excluding the power supply meets UL 60065 for
15. Universal Projector Bracket Pole Mount Kit WH oP l 1 V RCA 3 S vS S gt mme 1 MLC PW RS232 VC 50 emm E LO A H 4 10 32 Cover screws 4 Turnbuckles 3 4 40 screws SE 4 Me x40 mm serene 2 Velero pads 2 Cable clamps Gal Steel Ch KAO USCS yee 1 Safety wire 15 ft 1 8 in dia Gi Ge Se Mee 2 Tie wire 30 ft 14 AWG CATS T568A Patch 50 4 T frame screws 4 0 328 ID washers Quantity varies depending 2 Set screws 4 10 washers on PVS system ordered 1 Location screw 4 6 washers aaa 4 Adhesive pads These may be boxed separately 11 Hole plugs 1 Hex key or loose inside larger box 4 Adhesive pads 1 25 in Slotted pipe 1 Escutcheon ring WEEK NB Items not drawn to scale 1 6 PoleVault Systems Installation e Introduction Inventory Overview PoleVault System Devices and Hardware cont d PVS 305SA PVT CVD PVT RGB D Plus PVT CV D White PVT RGB D White 60 819 33 60 820 13 PVS 305SA 60 986 01 PVS 305SA PVT CV D PVT RGB Plus D PoleVault Switcher Wallplate Wallplate or optional PVT RGB D Plus White 60 820 33 COMPUTER Ee e HB 1 Mud ring E 1 3 pole connector 2 PVT mounting screws 3 5 pole connector 1 Decora Faceplate 1 Audio connector 4 pole 2 Faceplate screws PVT RGB Plus D 2 Securing screws 1 2 pole connector Wallplate 5 Tie wraps 1 Mud ring
16. align the hole with the PCM 340 e Replace the PCM 340 over the ceiling tile slide the slotted pipe up through the tile and into the adapter plate Realign the location holes with the pipe holes insert and tighten down the location screw Tighten the set screws f Tighten the four T frame securing screws on the PCM 340 The T frame securing screws can be used on either side of the frame Slide the pipe through the ceiling tile and into the pipe adapter plate Secure the Projector Drop Ceiling Mount to the ceiling a Attach the four turnbuckles to the mounting plate one at each corner SA eldl DO NOT rest or lean on the mounting plate or suspended ceiling when attaching turnbuckles tie wire or when drilling into the ceiling Va For safest installation insert the turnbuckle from the outside so that it hooks inwards b Cut four equal lengths of the supplied hanging wire and loop the wire through the anchors or lag eye bolts and the turnbuckles then twist the wire around itself at least five times tightly at each end c Hand tighten the turnbuckles and level the plate so it just rests on the T frame cr o7 NUR eldl The four hanging wires should be taut taking the full weight of the completed installation Do not overtighten the turnbuckles or the T frame assembly could be lifted making the suspended ceiling bowed and unsafe d Pass the braided safety cable through the fifth
17. ADA Standards for Accessible Design Section 4 4 Head Room for ADA requirements _ ma Walking Parallel to a Wall ADA referenced figure 8a redrawn ADA overhead and side clearance requirements e Viewing obstructions o Pillars furniture etc window locations for glare reduction obstructions between projector and screen 1 4 PoleVault Systems Installation e Introduction Planning c Location of MediaLink Controller and Wall Plates e Forward and side reach for full details refer to a copy of ADA Standards for Accessible Design Section 4 2 Space Allowance and Reach Ranges 10 30 25 5 cm gt 76 cm Max High Forward Reach Limits High Low Side Reach Limits Max Side Reach over Obstruction Limits ADA referenced figure 5a redrawn ADA referenced figure 6b redrawn ADA referenced figure 6c redrawn ADA highllow forward side and over obstruction reach limit requirements e Location of source devices o Desk table or rack mounted and proximity to proposed transmitter location wall podium or furniture e Cabling obstacles o Studs utility pipes power supply location raceway installation needed e Network drop for MediaLink Controller o Wall or floor cabled d Type and location of the speakers e Speaker type based on room ceiling and wall type e Total number and spacing of speakers o Based on ceiling height and room size e Audience seating and room acoustics
18. Optional accessory cables from the VoiceLift and Page Sensor may also be included QQ QV O O Cables to PVS 305SA O A V wall plate cables CAT 5 2 MLC 104 IP Plus switcher control cable 3 FF 120 speaker cables PoleVault Switcher Projector Pole D Cable Access Slot Cables to Projector de 5 6 4 IR RS 232 projector control cable To Projector 5 VGA cable 6 Video RCA cable K Not all cables that may need to be installed are shown here X Switcher and projector cable overview PoleVault Systems Installation e Installation Stage A 3 Finish installing the Pole Mount kit a Connect the cables as follows to the PVS 305SA Input wall plate CAT 5 cables according to the cable labels If using VGA inputs on switcher input ports 3 or 4 those ports must be reconfigured using the MLS Configuration software utility on the supplied DVD or available at www extron com The default input signal for ports 3 and 4 is video Va p Control power cable from the MLC 104 IP Plus Speaker cables VNU VGA and RCA cables Ga Connect the cables to the switcher VoiceLift Receiver cable optional see page 2 29 Aux audio input 5 cable Paging sensor cable optional Line out cable to an assistive or recording device optional see audio warning card for details Power supply Do not
19. PC signal to local monitor Installation hardware needed may vary per installation O O O OOOO Bolts for concrete structural ceilings where needed Toggles used for screen mounting on dry wall S hooks for hanging the screen Spare ceiling tiles in case of accidental damage during installation Electrical box where installation of a box on the PCM 340 is desired Safety wire lag eye bolts and strain reliefs for installation and securing ceiling speakers Heat shrink extension cord c Optional items The optional Extron products suggested below can be added to or substituted for items in the standard PoleVault System 1 8 Optional accessories OO OO OO 0 Wall mount speakers e g SI 26 or extra ceiling speakers MLC 104 IP Plus DV controller includes DVD VCR IR control MLC 104 IP Plus L controller with lectern faceplate MLC 104 IP Plus AAP controller with AAP opening MLC 226 IP controller Priority Page Sensor Kit P 2 DA2 Optional installation hardware O CO Er E FCMP flat ceiling mount ACMP angled ceiling mount SMB surface mount boxes for installing the MLC on a podium or desk EWB external wall boxes to mount devices for a surface raceway system MLM WB lockable metal wall box with flip down 4U rack space Optional A V source inputs O Err Er Or E EN PVT RGB D Plus RGB Decora mount model with IR and local monitor output PVT CV AAP composite video architectural adapter plate mode
20. a a cables leaving the box must be plenum rated Tighten the cable clamp and secure the lid to the junction box Connect the Priority Page Sensor to MONE To enable the switcher s paging sensor port use the MediaLink Switchers Configuration program for MLS and PoleVault Switchers PVS available at www extron com the Paging Sensor port on the switcher Testing and Adjustment Procedure The fully installed system is shown below To test that the classroom audio is muted when a PA system announcement page occurs 1 Turn the classroom audio on 2 Speak into the PA system microphone The classroom audio should be muted while the PA system page occurs and be restored when the page ends 3 If the program fails to mute the classroom audio during a page turn the Sensitivity adjustment on the front panel of the PVS 305SA clockwise 4 Ifthe classroom audio is muted without a page occurring turn the Sensitivity adjustment counterclockwise Ensure the sensor and wires fit completely inside the junction box before attaching the cover Admin Building Classroom To Classroom Paging Speakers Ceiling Mounted Paging Speaker Priority in FF 120 e Sensor Speakers lee utput K AN Paging Sensor Input PVS 305SA PoleVault Switcher Paging System PVS 305SA POLEVAULT SWITCHER ADJUST J PAGING rea SENSOR D Norma D SIGNAL SENSITIVITY
21. and center anchor and attach it to the center holes on either side of the plate Ensure the cable is of equal length on both sides of the anchor and secure the cable using the cable clamps PoleVault Systems Installation e Installation Stage 1 Gei Hand tighten the turnbuckles 2 6 Installation Stage One cont d 8 Install the electrical box if required MENNA All electrical installation should be performed by qualified personnel in accordance with local and national building codes fire and safety codes and local and national electrical codes If required the following method is recommended for integrating a 4S Raco electrical box not supplied on the PCM base plate e g a Raco 231 2 1 8 inch deep 4x4 inch electrical box and a Raco 778 1 2 inch raised 4x4 inch plaster ring or similar Install the Raco box on the PCM plate as follows a Attach the box to the plate using the smallest notches in opposite corners of the cut out see figure 8a Do not tighten the screws fully at this time b On the opposite side of the PCM plate slide the plaster Use the smallest notches when attaching the Raco box ring under the screws The plaster ring anchors the box in place with PCM plate sandwiched between c Fully tighten the screws EZENNA For safety complete all wiring of the electrical boxes and accessories after the plate is fully installed an
22. de toutes les consignes de s curit et d exploitation avant d utiliser le mat riel Conserver les instructions Ranger les consignes de s curit afin de pouvoir les consulter l avenir Respecter les avertissements e Observer tous les avertissements et consignes marqu s sur le mat riel ou pr sent s dans la documentation utilisateur Eviter les pi ces de fixation e Ne pas utiliser de pi ces de fixation ni d outils non recommand s par le fabricant du mat riel car cela risquerait de poser certains dangers Sicherheitsanleitungen e Deutsch Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung Instandhaltung geben Dieses Symbol soll den Benutzer darauf aufmerksam machen da im Inneren des Geh uses dieses Produktes gef hrliche Spannungen die nicht isoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen e Bevor Sie das Ger t zum ersten Mal verwenden sollten Sie alle Sicherheits und Bedienungsanleitungen genau durchlesen und verstehen Aufbewahren der Anleitungen e Die Hinweise zur elektrischen Sicherheit des Produktes sollten Sie aufbewahren damit Sie im Bedarfsfall darauf zur ckgreifen k nnen Befolgen der Warnhinweise e Befolgen Sie alle Warnhinweise und Anleitungen auf dem Ger t oder in der Benutzerdokumentation Keine Zusatzger te e Verwenden Sie keine Werkzeuge oder Zus
23. first then wrap the clear section around it Use the supplied labels for clear cable identification during installation Signal Cable Label color RGB 1A Input 1 RGB Orange RGB 1 B Input 1 RGB Orange RGB 2A Input 2 RGB Yellow RGB 2B Input 2 RGB Yellow RGB 3A Input 3 RGB Magenta RGB 3B Input 3 RGB Magenta RGB 4A Input 4 RGB Light Green RGB 4B Input 4 RGB Light Green Video 3 Input 3 Composite Vid Dark Green Video 4 Input 1 Composite Vid Red 2 11 PoleVault Systems Installation e Installation Stage 2 Gei Pull the cables at each location 3 Install wall plates a Connect the CAT 5 cables to the rear of the input devices for RGB devices connect cable labeled A to port A and cable B to port B b If desired for PVT RGB D Plus plates use a three conductor audio cable and connect the audio return to the connector marked G ground wire R black wire and L red wire The other end will be connected to the Line Out connection on the PVS 305SA switcher w o T ff c If desired wire the IR connection using a two conductor ee SH cable Wire the ground to G and signal lead to S The Connect the cables to the AIV source other end will be connected to the IR Out port of the input devices at each location MLC 104 IP Plus controller Wall Mounting Bracket mud ring Decora Faceplate
24. level the bracket f Lift the projector up to the adjuster plate and slide it into place Tighten down the locking and pivot screws Gr Slide and lock the projector onto the adjuster plate 3 Verify the image location a Connect a power cable to the projector and turn it on Projector b Verify image size and location by loosening the Center Line PCM 340 pipe adapter plate wing nuts and adjust the plate left right to center the image Remember to include the vertical and horizontal offsets when aligning the projector Refer to the projector manual for information Measure the horizontal offset c When satisfied tighten down the plate wing nuts Lens Center Line Horizontal offset PoleVault Systems Installation e Installation Stage 1 2 4 Installation Stage One cont d 4 Cut the ceiling tile a Mark the location of the PCM 340 on the T frame This aids putting it back in the correct location when the tile is replaced Mark the screen direction on back of the tile e g with an arrow or to front to help orientation of tile when replacing it after cutting b Measure the distances X and Y see figure from the inner vertical section of the front and left T frame runners to the center of the Pipe Adapter Plate Rebeet Maximum Throw Distance Marks Ab Take measurements with the PCM 340 on the T frame
25. page 2 25 Test the system page 2 26 ETELE Final installation page 2 27 Extron USA East Extron Europe Extron Asia Extron Japan Extron China Extron Middle East 800 633 9876 800 3987 6673 800 7339 8766 81 3 3511 7655 400 883 1568 971 4 2991800 Inside USA Canada Only Inside Europe Only Inside Asia Only 81 3 3511 7656 FAX Inside China Only 971 4 2991880 FAX 1 919 863 1794 31 33 453 4040 65 6383 4400 86 21 3760 1568 1 919 863 1797 FAX 31 33 453 4050 FAX 65 6383 4664 FAX 86 21 3760 1566 FAX 2009 Extron Electronics All rights reserved
26. some of the steps discussed in the text Each image has a number e g Ga corresponding to the particular step described 2 1 MIO UO Ooo TTT o OUT a UU OOO Stage Fo Outline of installation steps Stage One Install the Screen and Projector Mark the screen location page 2 3 Install projector to verify location page 2 3 Verify the image location page 2 4 Cut the ceiling tile page 2 5 Preliminary safety hardware installation page 2 5 Finish projector drop ceiling mount installation page 2 6 Secure the projector drop ceiling mount to the ceiling page 2 6 Install the electrical box if required page 2 7 Install the screen page 2 7 Stage Two Install the A V Source Input Wall Plates and MLC 104 IP Plus Install the mud rings page 2 10 Pull cables at the input locations page 2 11 Install the wall plates page 2 12 Install the MediaLink Controller page 2 13 Stage Three Install the FF 120 Speakers Cut the ceiling tile page 2 17 Install the speaker on the drop ceiling page 2 17 Terminate the speaker cable for the PVS switcher page 2 18 ur Install the PMK 550 and the PVS 305SA Install the PMK 550 base plate page 2 20 Pull the cables at the switcher location page 2 21 Finish installing the pole mount kit page 2 22 Stage Five Configure the switcher and the system Configure the switcher MLS Switcher Configuration program pag
27. switcher Wall plates included may differ slightly from those shown in this manual A MLC 104 IP Plus MediaLink Controller Mounting screws 4 Captive screw connectors for Display RS 232 IR Comm Link Digital I O MLS RS 232 Power Ethernet N port Extron Rear View MLC 104 IP PLUS Right Side ea e Location of MAC address Where it goes Installs in a wall at a location convenient to user What it does Provides remote control of switcher and projector p PoleVault Systems Installation e Installation Stage 2 2 8 Installation Stage Two cont d Cables PVT transmitter installation e CAT 5 T568A signal transmission cables connects PVT input wallplates to PVS 305SA switcher MLC 104 IP Plus installation e MLC power and RS 232 control cable connects the MLC controller to the MLC Power control port on the PVS 305SA switcher e IR RS 232 communications cable control cable connects the MLC controller to the projector via RS 232 or to an IR emitter e LAN network cables not supplied connects the MLC controller to LAN 2 9 PoleVault Systems Installation e Installation Stage 2 CAT 5 Patch 50 ft 26 637 50 MLC PW RS 232 VC 50 ft 26 626 50 IR SERIAL COMM 50 ft 26 621 50 The installation must conform to national and local building and electrical codes and UL requirements Refer to the devic
28. technician for help This unit was tested with shielded cables on the peripheral devices Shielded cables must be used with the unit to ensure compliance Overview This guide covers the installation of the Extron PoleVault System in a drop ceiling room with a wood or concrete structural ceiling If the location has a concrete or beam style ceiling alternative ceiling mounts can be obtained separately from Extron see 2c Optional items later in this chapter It is assumed that the installer has some knowledge and experience of A V electrical or electronic device installation This guide takes the A V installer through the steps for installation and connection of each of the system s component parts It may be that the locations for the devices e g wall plates projector and screen have been pre determined However some room installation examples are given to help in installations where final location is yet to be determined The PoleVault System va Extron PoleVault Systems are easy to use network enabled all inclusive packages making them ideal for single projector K 12 classrooms PoleVault Systems use economical twisted pair cables for transmitting signals and include network connectivity for Web based asset management monitoring and control Va The hardware and devices listed on the inventory pages have detailed safety information installation set up and configuration instructions and should b
29. the back of the adapter plate Replace the projector with the UPB 25 bracket attached on the adjuster plate and tighten the adjuster plate locking nuts Connect the switcher s VGA and RCA cables to the projector Connect the IR RS 232 projector control cable to the projector Connect the projector power cord ensuring the cord exits via the cable notch in the PMK cover plate PoleVault Systems Installation e Installation Stage A Cable the projector Items needed to help complete this stage Stage Five Configure the Switcher and the System e Laptop or PC with a network connection ES e MLS Configuration program on supplied DVD or by gt Extron download from www extron com MediaLink Switcher Global configurator software Configuration Utility e MLC 104 IP Plus User s Manual e Projector manufacturer s user s manual e Device driver and or driver package download from www extron com ot Configure the switcher MLS Switcher Configuration program a Run the DVD or download and install on a PC or laptop the Extron MediaLink Switcher Configuration program b Ensure the PC and the MLC 104 IP Plus are connected to the LAN Version 1 2 0 6 The MLS Configuration Utility software Add MediaLink Switcher Graz E rn QB import GC Project dr Offline Emulation Emulation Mode fe If this is not possible connect a 2 5 mm
30. to reveal of the sensor two speaker wires MOE Loop only one of the speaker wires around the sensor cover Do not loop both wires Polarity need not be observed a Priority The other speaker wire must bypass the sensor and connect Page directly to the speaker sensor e Fora 25 V or 70 V system wrap 5 to 8 loops Ceiling Mounted e For a4 8 ohm system wrap 2 to 4 loops Paging Speaker Open the sensor and loop a wire around the sensor 3 2 PoleVault Systems Installation e Optional Accessory Installation 5 Close and latch the top of the Priority Page Sensor Reconnect the speaker cable to the speaker f UNE OUT AMPLIFIED AUDIO OUT 6 Strip 3 16 inches of insulation from each conductor on the l DONOT m m e o rT GROUND AL bare wire end of the remaining blue sensor cable Do not tin cl OR SHORT 2 418 S s S mem SPEAKER o o o o Ohms the leads Feed the wire into the junction box clamping it ourpurs J JX S down if necessary and connect the wires to the 2 pole captive Iesse P 10V 50mA CONTROL screw connector on the PVS 305SA Polarity need not be Ga Lo TxRx IR A 12V observed AR LTELUTLI SENSOR VOL MUTE PVS 305SA 7 Ifajunction box is being used in a plenum space ensure the Bane CO sensor and all wires fit inside the box as shown at right All S
31. AT 5 cable Bi 2 14 Installation Stage Two cont d The connections between the MLC 104 IP Plus and the PVS 305SA switcher should look like the figure at right Network 1 US AUDIOWVIDEO RECEIVER TCP IP f z PRESS TAB W 23 TWEEKERTO RE VE J EI E MLC 104 IP Plus Right Side Panel Connections made to the MLC 104 IP Plus e Sliding the cables into the opening secure the MLC 104 IP Plus to the mud ring with the provided machine screws Extron x MR 200 SH Modular Mud Ring Rotate locking arm and insert into wall opening Ae Secure the MLC 104 IP Plus to the mud ring 2 15 PoleVault Systems Installation e Installation Stage 2 Stage Three Install the FF 120 Ceiling Speakers This stage involves installing the devices shown below FF 120 Flat Field Ceiling Speakers FF 120 Speaker 2 Terminal Cover Cable Clamps 2 Seismic Tabs 3 per side Anchor Rings 2 T rails 2 Where it goes Installs in ceiling tiles at predetermined location for best acoustics Connects to switcher What it does Receives and outputs audio signal from PVS 305SA switcher Cables Speaker Installation e Speaker cable connects ceiling speakers to the PVS 3055A switcher SPK 18 35 ft PoleVault Systems Instal
32. Adjusting sensitivity knob Clockwise to increase Counterclockwise to decrease 3 and 4 Sensitivity knob adjustment Typical paging system with the PVS 305SA switcher By PoleVault Systems Installation e Optional Accessory Installation 3 3 Reference Information Specifications For detailed specifications and warranty information of the PoleVault System components refer to the device manuals or the product pages at www extron com Mounting hardware PCM 340 lee E Drop ceiling mountable Maximum load ssoeesoeeeseeeseeeeseee 50 lbs 22 7 kg Material eeeecccccceesssssceseeeeees Baseplate and pipe aluminum tie wire steel 14 AWG 70 000 psi tensile strength Dimensions EE 1 2 H x 26 4 W x 8 0 D 2 9 cm H x 67 0 cm W x 20 3 cm Di Eegeregie 25 length 1 5 11 5 NPT Adjustment ranges 1 5 23 0 drop 21 5 adjustability in 0 5 steps Product weige IM tssteevecpepeersopsestasarsss 4 5 lbs 2 kg Regulatory compliance SE CE c UL UL Mibratpon ccceessecceeesseeeeeseseeeeeees ISTA 1A in carton International Safe Transit Association PMK 550 Mounting POLE MOUNT sssrini Mountable to round projector mount poles either standard 1 5 3 8 cm NPT pipes or pipes with an outer diameter of 1 85 to 1 95 4 7 cm to 5 0 cm using included hardware Maximum load sossiusisannianso 15 lbs 6 8 kg Material Base plate Aluminum Elek S niarassspuncareasetcens High impact plastic IR E ET 3 0
33. Ces ouvertures ne doivent jamais tre bloqu es par des objets Lithium Batterie Il a danger d explosion gll y a remplacment incorrect de la batterie Remplacer uniquement avec une batterie du meme type ou d un ype equivalent recommande par le constructeur Mettre au reut les batteries usagees conformement aux instructions du fabricant Vorsicht Stromquellen e Dieses Ger t sollte nur ber die auf dem Produkt angegebene Stromquelle betrieben werden Dieses Ger t wurde f r eine Verwendung mit einer Hauptstromleitung mit einem geerdeten neutralen Leiter konzipiert Der dritte Kontakt ist f r einen Erdanschluf und stellt eine Sicherheitsfunktion dar Diese sollte nicht umgangen oder au er Betrieb gesetzt werden Stromunterbrechung e Um das Ger t auf sichere Weise vom Netz zu trennen sollten Sie alle Netzkabel aus der R ckseite des Ger tes aus der externen Stomversorgung falls dies m glich ist oder aus der Wandsteckdose ziehen Schutz des Netzkabels e Netzkabel sollten stets so verlegt werden dafs sie nicht im Weg liegen und niemand darauf treten kann oder Objekte darauf oder unmittelbar dagegengestellt werden k nnen Wartung e Alle Wartungsmafnahmen sollten nur von qualifiziertem Servicepersonal durchgef hrt werden Die internen Komponenten des Ger tes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall dieses Ger t selbst ffnen da beim Entfernen der Abdeckungen die Gefahr eines elek
34. Extron Electronics TON z 6 INTERFACING SWITCHING AND CONTROL turio Installation Guide PoleVault Systems featuring the PVS 305SA Installation Guide 68 1691 01 Rev A 08 09 Precautions Safety Instructions e English OG This symbol is intended to alert the user of important operating and maintenance servicing instructions in the literature provided with the equipment A This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product s enclosure that may present a risk of electric shock Caution Read Instructions e Read and understand all safety and operating instructions before using the equipment Retain Instructions e The safety instructions should be kept for future reference Follow Warnings e Follow all warnings and instructions marked on the equipment or in the user information Avoid Attachments e Do not use tools or attachments that are not recommended by the equipment manufacturer because they may be hazardous Consignes de S curit Francais Cesymbole sert avertir l utilisateur que la documentation fournie avec le mat riel contient des instructions importantes concernant l exploitation et la maintenance r paration Ce symbole sert a avertir l utilisateur de la pr sence dans le bo tier de l appareil de tensions dangereuses non isol es posant des risques d lectrocution Attention Lire les instructionse Prendre connaissance
35. OTE p pply installed above the suspended ceiling in wall cavities or similar locations To mount the PoleVault switcher invert the base plate and attach the switcher to the plate by inserting the two supplied 4 40 x 3 16 inch screws up through the plate and into the top of the switcher The switcher should be mounted on the same side as the base plate s pipe collar Using a 3 32 inch hex wrench loosen the four pipe XN Using a 5 32 inch hex wrench remove the four cover screws from the center of the PMK 550 and slide the two halves apart Remove them from the base plate au Ifthe PoleVault switcher and its power supply are already installed go directly to step 2d PVS 305SA and power supply on the PMK 550 base plate inverted The top of the switcher should be secured to the plate so that when the plate is inverted to hang from the ceiling the device will be in its correct orientation Use only the supplied screws to avoid damaging the switcher Attach the associated power supply with the supplied Velcro strap and pads by passing the strap through the appropriate slots and around the power supply Tighten until snug Slide the base plate up onto the pole and secure with the set screws collar set screws and slide the plate up the pipe until the base plate is touching the drop ceiling Level the plate and secure it in place with the four set screws located on the collar ensur
36. TRS configuration cable part 70 335 01 to the PC and to the front panel configuration port of the MLC 104 IP Plus Select a MediaLink switcher from the list provided below and click OK Select Switcher pys 30554 Description Five Input PoleArray PoleYault Twisted Pair Switcher with built in power amplifier c Launch the MLS Configuration utility Select the connection format RS 232 or TCP IP or select the emulation mode see figure o Noy Au offline emulation of the PVS 305SA can aid in becoming familiar with the PVS 305SA before configuring an active unit S 1c Launch the MLS Configuration program d Once the program is running click on Help Contents or press F1 and follow the instructions mi gi Connect wile Disconnect E Refresh S clone H Reset Zo Security Gain Attenuation Audio Video Inputs Global AA Configuration a A S 7 z e P o 23 EE pa CS SE Eer BAG DE veces seg Miel Untitled MLS Configuration Offline PVS 305SA S SE z i 3 R E File view Tools Help i 3 New P3 d C E3 Open Led 9 Contents Fl ke kel kel kee ke kat Sege E kl bg Le LE Extron Home Page g Signal Gi Gi MT j L Tr i Check For Updates voll WA MLS View deel Es Audio Settings VoiceLift Mic Mic Talk Over Offline PYS 305SA Clip Status
37. al Wire color Left and Right AMPLIFIED OUTPUTS TTTtIttit 4 8 o o o Ohms Red Positive GES Black Negative PVS Switcher Rear Panel Wire the captive screw connector Stereo output Dual mono output AMPLIFIED OUTPUTS AMPLIFIED OUTPUTS 8 Ohms 8 Ohms Stereo L Stereo R Stereo L Stereo R 8 Ohm Load J K Stereo or dual mono output using parallel speaker wiring AMPLIFIED OUTPUTS Two 8 ohm speakers Mono 4 8 OhmS Mono wired in parallel equal a 4 ohm load ohms Stereo L Stereo R 4 Ohm Total Load 4 Ohm Total Load Mewes By default the amplifier is set for dual mono output Use the software or SIS Extron Special Instruction Set commands to change the setting to stereo if desired For full details refer to the PVS 305SA Users Manual available online at www extron com PoleVault Systems Installation e Installation Stage 3 2 18 Stage Four Install the PMK 550 and the PVS 305SA This stage covers installing the devices shown below PMK 550 Pole Mount Kit To open remove 4 cover screws 10 32 button head hex and slide the covers away PMK Covers 2 Where it goes Attaches to slotted pipe above the projector and close to the drop ceiling What it does Supports and hides the installed PVS 305SA swi
38. apply power yet at Do not thread any high voltage power cabling such as power supply or projector power cords through the projector pipe This violates National Electrical Code assi CAT 5 cables with RJ 45 connectors PVT RGB D Input 2 cables A and B Power ED ae Connector ne Li i el Se External 4B RGB Power Supply 12 VDC 5 A max CAT 5 cable with Y RJ 45 connector E Ii Paging VGA RCA Sensor g SERIES Connector Aux Audio g U Input 5 E 4 Voice Lift oy RGB output 1 Receiver to projector E ewe F Input ES Video ouput MLC104 IP Plus 2 geusi C le ion AUDIO VIDEO LISTED ER G a Se UA 7 H gi to projector Line out output to stive recording device Audio output to speakers Speaker PVS terminal wire color left and right Positive Negative APPARATUS VOICELIFT T o 50mA CONTROL ere TxRxIR 12V AUX AUDIO RS 232 dl Se ie ere Receive Rx B Transmit Tx A RS 232 input MLC To PVS terminal wire color White A Tx on RS 232 port B Rx on RS 232 port D Ground D E Violet Drain wire Black Red Ground 12V A PoleVault Systems Installation e Installation Stage A 2 22 Installation Stage Four cont d b d e f 2 23 Screw the UPB 25 adjuster plate back onto the base of the pipe and tuck the cables through
39. atzger te die nicht ausdr cklich vom Hersteller empfohlen wurden da diese eine Gefahrenquelle darstellen k nnen Instrucciones de seguridad e Espanol EN A Precaucion Leer las instrucciones e Leer y analizar todas las instrucciones de operaci n y seguridad antes de usar el equipo Este s mbolo se utiliza para advertir al usuario sobre instrucciones importantes de operaci n y mantenimiento o cambio de partes que se desean destacar en el contenido de la documentaci n suministrada con los equipos Este s mbolo se utiliza para advertir al usuario sobre la presencia de elementos con voltaje peligroso sin protecci n aislante que puedan encontrarse dentro de la caja o alojamiento del producto y que puedan representar riesgo de electrocuci n Conservar las instrucciones e Conservar las instrucciones de seguridad para futura consulta Obedecer las advertencias e Todas las advertencias e instrucciones marcadas en el equipo o en la documentaci n del usuario deben ser obedecidas Evitar el uso de accesorios e No usar herramientas o accesorios que no sean especificamente recomendados por el fabricante ya que podrian implicar riesgos ZEM e PM J N BE SERA PRE A REI RSS bi Cep SBR BE ARB eke it ee In Dirt HAASE AS Ls AK aL FIER AE Aa De HE OI REHAB HMR ZC DE DS RAE N OPES o HPN EPS LMOTP EU SIM AE AP a BATHE RE LAI I DGS EI D
40. bove the drop down box Repeat as needed following the instructions on the pages to configure the MLC 104 IP Plus as needed ean X Extron Global contigurator File Edit View Build Tools Help 0 adla aal Contents F1 About GC2 IP Link Settings Schedule Monitor Port Summary Front Panel gt Front Panel Sgt Oo IP Link Device Type Brand GlobalViewer md MLC 104 IP Plus Series 192 168 CH Control Ports S Display Serial Display IR CH MLS Port none Control Modules BR Address 1 BR Address 2 j Address 3 ES Address 4 Dikan Minar ziessen Gei Launch Global Configurator E Global Configurator 2 4 Help File af gt amp amp Hide Back forward Refresh Print Options ES gt ns Contents Index Search Previous Next Ka E Ka Ka 4 Configure Configure Assign Set HiSystem 5 1P D Contacts Email Device COM Co The GE 2 4 Help File Global Configurator Prere Wi System P Ip Introduction Getting Started Step by Step Product Cor Globalviewer How dol Reference Information Common Global Configure BHIPLT S Series Glossay Sal and Set the IP Address BIL PC BIPLT CR48 WE Se Ways w Add a Device dialog box g Global Configurator 1 Click Edit gt Add Device File Edit View Build Tools H i Sele
41. cordance with local and national building codes fire and safety codes and or local and national electrical codes To meet the plenum rating requirement the Priority Page Sensor assembly must be installed in a UL compliant junction box with a cover and all cables to and from the sensor must be plenum rated 1 Choose a suitable location for the sensor It must be located near and in series with the speakers 2 If the sensor is to be located in a plenum space the junction box provided can be used Knock out an opening at one end of the junction box and attach the cable clamp see figure at right Secure the box where the sensor will go 3 Disconnect the PA system speaker cable from the speaker Remove the outer protective jacket from the speaker cable to L expose the two speaker wires from the sensor to the speaker as shown at right Do not remove the inner protective jackets that cover the individual wires Y e D gt J Open the If the sensor is to be located in a plenum space feed a loop Page Sensor of one of the exposed speaker wires through the cable clamp into the junction box The other wire must bypass the sensor to be connected later directly to the speaker Speaker Cable with 4 Open the top of the Priority Page Sensor and loop the speaker GE Jacket Intact Strip plenum jacket from wire that is inside the junction box tightly around the top part N speaker cable
42. ct MLC 104 IP PlusiPoleVault System GN Global Configurator Help Configure the MLC 104 IP Plus Front Panel The Front eri pryder e cerca roetoatspt pcfpes HL rau Pius toencoieci pass none Pe ais bs a hay be ZE rd Sage bimbi Bee BE et oe er n Kr ie Lass Veh e si origan SV Ee Ire hast Configure the MLC 104 IP Plus LG ef d 2 25 PoleVault Systems Installation e Installation Stage 5 3 Test the system a Connect all the input devices e g PC DVD document camera etc to the transmitters and power up the input devices Check that power and signal are present at the transmitters The LEDs light red when only power is present and light green when power and a signal are present Extron ug RAR PU b At the MLC 104 IP Plus turn on the Display Once the the projector is powered up check with an active video source PC or DVD that a good image is shown on screen Let Check the MLC controller configuration and wiring if the display does not turn on c Properly align and adjust projector settings as follows Bb 6b Connect and turn on the input devices and turn on the display at the MLC e Adjust the rotation yaw by turning the unit on the projector pole Secure the location by tightening the two set screws on the UPB mount plate to the pole see below e Loosen all pivot screws and adjust the vertical angle pitch of the projector Lock down the
43. d safety goggles Razor knife 2 hole saw Painter s tape to mark up walls pencil and marker pen RJ 45 crimpers and RJ 45 connectors Voltage tester Fish tape pull string and electrical tape for taping fish tape to pull string Zip ties Vacuum cleaner Heat gun PoleVault Systems Installation e Introduction Inventory Overview 1 9 Installation Overview This overview outlines the basic steps for installing the PoleVault System Detailed description of these steps is given in five sections Stages One though Five Carefully check inventory of PoleVault system packages input and output devices any optional accessories and Noyes Additional installation hardware is needed and should be supplied by the installer See Introduction Items not included on page 1 8 for a list Optional accessories may be desired for this installation For a list see Introduction Optional items on page 1 8 or visit www extron com for details Refer to local building standards and codes to verify that the installation will meet all the regulatory requirements Observe all local and national building and safety codes UL requirements and ADA Accessibility Guidelines Refer to the specifications at the end of this guide for system hardware weights and dimensions installation hardware before commencing Where possible in the following pages line drawings and photos from an actual installation are used to clarify
44. d secure d Mark and cut a hole in the ceiling tile for the electrical box opening Install Raco box and plaster ring 9 Install the Screen a Following the screen manufacturer s guidelines continue to install the screen mounting brackets and then hang the screen Use S hooks to hang the screen from the brackets Bend the ends of the S hooks so the screen does not fall when it is rolled up 2 7 PoleVault Systems Installation e Installation Stage 1 Stage Two Install the Wall Plates and MLC 104 IP Plus This stage involves installing the devices shown below PVT CV D and PVT RGB D Plus PoleVault AIV Source Input Wall Plates PVT CVD PVT RGB D Plus O Line Out Audio and fg Audio Output VIDEO IN See SCH A VIDEO IN Video GIE Pat Port at Audio Input apen Connectors Llaes Connector Connectors wes E Local Monitor at rear inet IR Input elle Output Port Connector ffe 2 IR Output Beie at rear esteem pra ees IR Input i Connector IR Output CO at rear Audio and Video Audio and Video Decora Mountin Faceplate Screws 2 PEIEE ORALE EEN Each RGB Wall Plate needs 2 Output Cables A and B Where it goes What it does Installs in a wall near input source location Transmits an input source s composite or RGB video signal and audio signals to the
45. e 2 24 Configure the system Global Configurator page 2 25 Test the system page 2 26 Final installation page 2 27 PoleVault Systems Installation e Installation Stage One Install the Screen and Projector This stage involves installing the three pieces of hardware shown below PCM 340 Projector Drop Ceiling Mount Slotted Pipe 1 gang and 2 gang Accessory Mounting Points e g Power Sockets Pipe Adapter Pipe Adapter Plate Wing Nuts 4 Base supplied with PCM 340 projector T frame Securing Screws 4 Pipe Adapter Slotted Set Screws 2 Pipe e P Where it goes Ge Eeer ceiling rests on Where it goes Locks into place in P ei PCM 340 pipe adapter What it does Holds slotted pipe PoleVault pole l mount kit PMK 550 see Stage 4 and Wee ne a DEER UPB 25 Universal Projector Bracket shown separated into the two sections Adjuster Plate Top Section Set Screws 2 Vertical Angle Horizontal Angle Adjustment Screws 4 ecurity Flange on rear Adjuster Plate screws onto base Attaches projector to PCM 340 Where it goes What it does Sg Adjustment Screws 4 2 L pivot Point Screws 4 Projector Bracket Bottom Section Screw _ Y IZ Threaded Barrels 4 Arm Adjustment Screws 4 Security Flange on rear w 360 Movement of slotted pipe and Project
46. e kg e VLR 102 Receiver e Wall charger Installation Procedure a WARNING All structural steps anchoring and electrical installation should be performed by qualified personnel in accordance with local and national building codes fire and safety codes and local and national electrical codes E E a e PARERS SW Oe Q Attach the Z Bracket to the ceiling tile 1 Determine the optimal receiver location and mark and drill a 2 5 inch hole in the ceiling tile where it is to be installed and the back plate 2 Insert the ceiling bracket screw through the back plate attached to the housing and the hole in the ceiling tile and loosely attach the Z bracket 3 Align the back plate knockout over the hole in the ceiling tile and tighten the bracket screw to secure Arrow Replace the ceiling tile Pull the communication power RJ 45 Ethernet cable and other secondary use cables through the receiver s base ge and connect the Ethernet cable to the Receiver OUT port cae the RJ 45 connector on the left on the receiver base 6 If desired set the Tone and Mix DIP switches on the receiver base Align Arrows 7 Place the dome onto the housing align the arrows on the dome s locking tab and on the housing rim Turn the dome until it locks in place approximately 1 8 turn 8 Pull the cables from the receiver to the PVS 305SA switcher s location through the pipe and down into the
47. e referred to as needed For operation and setup of the projector screen and input devices refer to the relevant manufacturer s manuals supplied with those devices A PoleVault System Installation video is viewable online at www extron com This video is also a step by step guide to installing Pole Vault System and is useful for first time installations PoleVault Systems Installation e Introduction 1 1 Introduction cont d Extron FF 120 Flat Field Extron Priority Extron Ceiling Speakers SPK 18 35 1 Pair Page Sensor Cable lt A Optional Accessory From NZ J PA system UTP Cable CAT 5 5E 6 Ceiling Mounted Paging Speaker Extron E PCM 340 xtron Projector Drop VoiceLift Receiver Ceiling Mount Optional Accessory Extron Nf PVS 305SA Tei PoleVault Switcher BZ Sa ee one Extron gt 3 J e PMK 550 a L Easy Installation Pole Mount Kit Extron UPB 25 Universal Projector Mounting Bracket Assistive Listening System Extron PVT CVD R Composite Video gt amp Audio Input j N Wallplate lt L p ge Dr l S ES Ly gt A RS 232 to Switcher Emi Extron Emitter PVT RGB D Plus VGA amp Audio Input Wallplate Extron pang PVT RGB D to Projector VGA amp Audio Input Wallplate DVD VCR Combo Extron TCP IP MLC 104 IP Plus Newari MediaLink Controller Extron PVT CV D Composite Video amp Audio Input Wallplate
48. e talk over threshold level range default 6 0 to 30 program audio ducking level in talk over mode default 15 Lineout status 1 variable default 2 fixed Paging delay on 1 second steps default 0 disabled 1 1 0 second 2 0 2 second 8 8 0 second Response switcher to host Ty pka k23 4 Ty pki k23 4 Status Commands View all input status View paging sensor status Frq Sts42 k3 e Mic Talk over Threshold Adjust talk over threshold Decrement threshold Increment threshold View mic threshold Thrik25 e4 Thrk25 Thrk25 e4 Thrk25 Program Audio Ducking Level Adjust audio ducking level Increment audio ducking Decrement audio ducking View audio ducking Adlk26 4 Ad k26 4 Adlk26 4 Ad k26 lt 4 Set Lineout Mode Set lineout to variable Set lineout to fixed View lineout mode LineOut k27 44 LineOut k27 44 LineOut k27 44 Set Audio Output Mode Set audio output mode to mono Set audio output mode to stereo PreAmpMod k2e4 PreAmpMod k2 e4 Set Output Volume Level Specify volume Increment volume Decrement volume View volume Volke Volke Volke Volke Paging Sensor Delay Set paging sensor delay View paging sensor delay PageDly k29 44 PageDly k29 For full Pole Vault device specifications optional accessories and part numbers visit www extron com PoleVault Systems Installation e Basic SIS Commands 5 1 Extron USA West Headquarters
49. each speaker that needs to be AER A installed connecting the speakers according to the system preferred e g in parallel see page 2 18 Remove terminal cover and attach clamp and ring j If you wish to install an optional seismic safety cable at each speaker location do the following i Anchor this end to a g Mark drill and install a lag eye bolt for the seismic lag eye bolt screwed safety cables not included in the structural ceiling into the structural ceiling above the speaker location Route the safety cable through the anchor ring h Pass the seismic cable through the anchor ring down gt an and the seismic tab to the seismic tab and twist the end around the cable 5 times Pass the other end up through the lag eye bolt and twist that end around the cable 5 times Seismic Safety Cable h Attach safety cable 2 17 PoleVault Systems Installation e Installation Stage 3 3 Terminate the speaker cable for the PVS switcher e ae oe i Wi a To terminate the cable strip the end of the cable 0 2 inch WOOP e e 5 mm and secure the wires into the supplied pekinese Ee Speaker 1 Speaker 2 4 pole captive screw connector Lait The correct speaker impedance loading must be observed when setting up a speaker system See figures below for examples Audio output to speakers 4 pole Captive Screw Connector Speaker To PVS 305SA termin
50. er oupply Pole Mount Kit y Ze included with weight 2 4 lbs 1 2 kg l 9 p q PVS switcher D R D SS e weight 0 9 Ibs 0 4 kg Extron x 7 PVS 305SA PoleVault Switcher weight 2 5 Ibs 1 1 kg Extron Total weight UPB 25 without projector Universal Projector or electrical boxes Mounting Bracket 14 16 Ibs 6 4 7 3 kg weight 3 7 lbs 1 7 kg Projector weight must not exceed 25 lbs 11 3 kg Ceiling mount installation diagram with item weights for PoleVault System 4 3 PoleVault Systems Installation e Reference Information SIS Commands PVS 305SA specific symbol definitions MOJI For a complete list of SIS commands for the PVS 305SA refer to the PVS 305SA User s Manual available online at www extron com CR LF carriage return line feed hex 0D 0A lt CR no line feed e Space Esc Escape key k Input numbers 1 through 4 and 7 0 all outputs muted both audio and video 1 and 2 RGB inputs 3 and 4 Composite video inputs Audio mode 1 Dual mono default 2 Stereo x3 Status 0 Off 1 On Volume 0 100 default 50 R II SIS Command Response Table Command Video Configuration Set the video signal type View the video signal type X23 ASCII Telnet host switcher Video type inputs 3 and 4 only 1 Composite video default 2 RGB Video signal status 1 A video signal present 2 No video signal detected 0 to 15 microphon
51. es user manuals for details XN Be 1 Install the mud rings ae These devices can be installed using the supplied mud ring or a wall box If installing a box allow enough depth for the plate and the cables The box should be at least 2 5 inches 6 4 cm deep to accommodate the connectors and cables If a suitable wall box is already installed follow step 2 onwards Wall Mounting Mud Ring XX a Using the mud ring as a template trace the inside of the mud ring onto the mounting surface b Cut out the material within the marked area c Insert the mud ring into the opening The mud ring s rear doglegs should fit easily into the opening Flip over the mud ring doglegs and secure with the screws provided TIP Use a level when fitting the mud ring Repeat steps a to c for each additional input wall plate that needs to be installed d At the desired location mark the opening for the larger Rome the dociep autor MLC 104 IP Plus mud ring the way to insert the e Repeat steps b and c S Dogleg i e Screw Equipment Mounting Holes Surface Mounting Mud Ring Features for mud ring installation PoleVault Systems Installation e Installation Stage 2 2 10 Installation Stage Two cont d 2 Pull the cables at the input locations The following cables need to be installed e CAT 5 cables for signal transmission from the A V wall plates to the PVS 305SA
52. evel i e where the input normal LED flashes indicating the level is set properly This ensures there is no clipping if the MLC volume is turned to maximum during operation e Repeat step e for all inputs Where installed to adjust the microphone sensitivity switch on the microphone press and hold the volume down button until no beeps are heard from the speakers Then press and hold the volume up button until six beeps are heard To adjust the VoiceLift audio output level rotate the VoiceLift encoder on the PVS 305SA switcher to the normal setting and the LED lights Test and adjust the microphone so that the amplified voice is heard just above the normal voice level at each speaker location Refer to the VoiceLift Users Manual for details de The MLC volume control does not control the VoiceLift volume By default the switcher has been configured properly where the input level adjustment and VoiceLift input adjustment may not be required Where installed if necessary adjust the sensitivity of the Priority Paging system During a test transmission of the Paging system rotate the Paging Sensor encoder until program audio is no longer heard from the PoleVault speakers Refer to the Priority Page Sensor Installation Instructions for full details et The Paging Sensor feature must be enabled using the MLS Configuration software or SIS commands prior to adjustment 4 Final installation a 2 27 Slide the co
53. four adjustment screws e Adjust the horizontal tilt roll of the projector Lock down all the remaining adjustment and pivot screws e Adjust the image settings on the projector zoom focus keystone brightness contrast etc Refer to the manufacturer s user manual Extron Electronic Vertical C Horizontal Angle Angle Adjustment Adjustment and and Pivot Pivot Point Screws Point Screws K e these 2 set screws J one each side to lock the Yaw Rotation Roll Tilt gos UPB onto the pole o Gei Check that an image is present adjust as needed Adjuster Plate Locking Screws 4 a PoleVault Systems Installation e Installation Stage5 2 26 Installation Stage Five cont d d Test the controller s configuration with the following e Check that the MLC is controlling the PVS 305SA switcher and projector and output s the correct image when switching inputs e Check the projector s power control turn it off and on at the MLC controller e Adjust the configuration as necessary e Adjust the audio input sensitivity as follows e Ensure there is an audio source at each transmitter e Set the MLC controller s volume to maximum e On the PVS 305SA switcher set the volume for each input by selecting an input and rotating the Volume encoder to a comfortable maximum l
54. ing that a minimum of three set screws are tightened firmly against the pole PoleVault Systems Installation e Installation Stage A 2 20 Installation Stage Four cont d 2 Pull the cables at the switcher location a 2 21 Gather all the cables from the speakers A V wall plates MLC 104 IP Plus controller and any installed optional devices that have been run to the switcher location and pull them down through the ceiling hole and the pipe These cables are e the MLC power RS 232 cable e the CAT 5 input cables from the wall plates e the speaker cables e the MLC to projector IR RS 232 projector control cable e any optional device cables e g Aux audio input Priority Page Sensor Kit VoiceLift etc Pull the cables out of the pipe slot towards the switcher ready for connection Leave the IR RS 232 projector control cable to hang out of the bottom of the pipe Connect the output video signal cables VGA and RCA to the switcher and pull the loose ends down the pipe so that they hang out the pipe with the IR RS 232 projector SS Va control cable These cables connect to the projector later et Do not thread any high voltage power cabling such as power supply or projector power cords through the projector pipe This violates National Electrical Code Gather the cables pass them the pipe down Cables from A V wall plates MLC 104 IP Plus and FF 120 speakers
55. l PVT RGB AAP RGB architectural adapter plate model PVT RGB RGB rack mount model PVT SW RGB RGB rack mount model with switching capabilities PVT CV composite video rack mount model PVT RGB CV RGB and composite video rack mount model Optional speakers O O Ov Os OO SI 3 Compact Full Range Surface Mount Speakers SI 26X Two Way Open Back Ceiling Speakers SI 26W Two Way In Wall Speakers with 6 5 Woofer SI 28W Two Way In Wall Speakers with 8 Woofer SI 26CT Two Way Ceiling Speakers with 8 Back Can and Transformer SI 26 Two Way Surface Mount Speakers with 6 5 Woofer SI 3C LP Full Range Ceiling Speakers with 4 Low Profile Back Can PoleVault Systems Installation e Introduction Inventory Overview d To aid the professional installer this checklist gives the tools recommended to complete the installation Installation tools Tools should include but are not confined to Laser level or two levels large for screen installation small for wall plates and projector mounts Tape measure Stud finder Drill and drill bit set including a Unibit to cut through metal studs Extension drill bit 3 4 min 4 to 8 foot length to drill through fire breaks Socket set Pipe strap or wrapped pipe wrench Lineman s pliers and wire strippers Standard screwdriver set and Tweeker Cable cutters to cut safety wire Dry wall saw and hacksaw blade mounted on handle for cutting ceiling tiles Flashlight an
56. lation e Installation Stage 2 2 16 Installation Stage Three cont d at The installation must conform to national and local electrical codes and UL requirements Refer to the device s user manual for details Ne d 1 Cut ceiling tile If installing FF 120 speakers do the following a Remove the ceiling tiles where the speakers are to be installed For ease of working on the speaker when it is replaced on the T frame remove an adjacent tile s b Mark a line 12 inches from one of the short sides of the tile and cut along the line Discard the short portion Use a fine hacksaw blade to cut the tile without damaging the face and place an empty box under the tile for support and to collect the waste 2 Install the speaker on the drop ceiling a At the speaker location lay one of the supplied T rails 12 inches from one end of the T frame The speaker will be placed into the small section b Remove the terminal cover from the rear of a speaker and attach the anchor ring and cable clamp to the cover c Place the speaker onto the T frame and passing the speaker cable through the cable clamp connect the speaker wires to the speaker terminals e Red wire positive e Black wire negative d Reattach the terminal cover e If possible bend the seismic tabs over the T rails f Replace the ceiling tile Repeat the steps 1 and 2 for
57. o Desired spread and evenness of sound coverage and ambient noise level compensation SSES SE Student Desks Wa Ka Each speaker covers one fourth of listening area ee Speaker Windows Location Projector Switcher Location mm ee _ MLC Controller Geen E Location K Teachers f Desk TV VCR DVD Inputs ETE ee eee ee PVT A V Wallplate Screen White board Location Location Example classroom with four speaker installation PoleVault Systems Installation e Introduction Planning 1 5 Introduction Inventory Overview 2 Inventory a Included items The PoleVault System PVS xxx ships in two boxes The larger box 42 1xx xx contain the devices and hardware individually boxed and labeled The smaller box 42 120 03 contains only the FF 120 speakers Each PVS system has the same quantities of speakers hardware and devices but differs in the number and type of PoleVault A V Source Input Wall Plates and are shipped as follows e PVS 200 part 42 108 03 includes one PVT RGB D and one PVT CV D e PVS 300 part 42 109 03 includes two PVT RGB D and one PVT CV D e PVS 400 part 42 110 03 includes two PVT RGB D and two PVT CV D Carefully check all the received items against the following lists PoleVault System Devices and Hardware CABLES UPB 25 White 60 773 03 1 MVGA MM 3 PCM 340 Projector Drop Ceiling Mount UPB 25 PMK 550 JO
58. or Bracket attaches to projector Allows projector orientation to be adjusted in three planes Projector Securing PoleVault Systems Installation e Installation Stage 1 2 2 Installation Stage One cont d 1 Mark screen location a Mark the center line and the outer edges of the screen When marking the location of screens devices or the site for installing transmitters and MediaLink control devices use painters tape to avoid wall surface damage When marking the center line of the screen where possible keep it aligned with the center of the ceiling tile This makes the projector installation and alignment easter b Mark any structural studs utility pipes conduits or fire breaks before drilling the hardware holes Do not drill the holes at this time 2 Install projector to verify location a Remove the ceiling tiles and mark the maximum and Minimum Maximum minimum throw distances on the T frame Refer to the Throw Distance Marks projector manufacturer s installation manual for more information b Place the PCM 340 over the T frame between the two marks Lightly tighten the T frame securing screws The T frame screws can be used on the outside or the inside to secure the PCM to the T frame Place the PCM 340 on the T frame so that the pipe adapter slides left to right in relation to the proposed screen location rather than towards and away from it This make
59. raciones mantenimiento e Solicitar siempre los servicios t cnicos de personal calificado En el interior no hay partes a las que el usuario deba acceder Para evitar riesgo de electrocuci6n no intentar personalmente la reparaci6n mantenimiento de este equipo ya que al abrir o extraer las tapas puede quedar expuesto a voltajes peligrosos u otros riesgos Ranuras y aberturas e Si el equipo posee ranuras o orificios en su caja alojamiento es para evitar el sobrecalientamiento de componentes internos sensibles Estas aberturas nunca se deben obstruir con otros objetos Bater a de litio e Existe riesgo de explosi n si esta bater a se coloca en la posici n incorrecta Cambiar esta bater a nicamente con el mismo tipo o su equivalente recomendado por el fabricante Desachar las bater as usadas siguiendo las instrucciones del fabricante 2a CBIR Wo EI r RII W WAR LRA BENE BATRI o BRER ee TEL RAR FL FILER Rem ZEM neg RERE mmm o AREARE VERA A DUET EASA Ee rell EA J ae HL wun E EE CURT TE TA BLA MAL AEREE ABERI CERDA BUREE BERETA PREL SRT KEMERE WAIRERE o DIES RREA E PAIRE PAT ARETE BE FPL ib Vm FAA WRUHA RR ER IA Bk FR ID EE DI EEN Zb H AYE ny 224 TH
60. s aligning centering the image easier e SC c Slide the slotted pipe up into the pipe adapter Adjust to the desired height and align the location holes and pipe holes Insert the location screw lightly tightening it down using a 5 32 inch hex wrench Insert and lightly tighten down the set screws onto the pipe Do not overtighten as the pipe is removed and replaced later during installation Align Pipe holes with location screw holes d Take the UPB 25 and back out the set screws using a G ON Be eg 3 32 inch hex wrench on the top portion of the adjuster and secure plate see below and then screw the plate onto the base of the pipe Align it so the security flange is at the Gei Insert and secure the slotted pipe rear Set Screws 2 Adjuster Loosen the four Adjuster Plate Locking Screws and slide the Adjuster Plate away from the Projector Bracket T Oe the base Screw the adjuster plate onto of the pipe 2 3 PoleVault Systems Installation e Installation Stage 1 e Using suitable screws mount the projector onto the projector bracket i e the lower portion of the UPB 25 as shown in step 2e s image Align it so the security flange is at the rear A minimum of three arms need to be attached to the projector Adjust the arms to fit as needed Lock down the arm adjustment screws Adjust the threaded barrels at the end of each arm to
61. safety ER EE eegen CE C tick FCC Class B ICES VCCI Environmental 004 Complies with the appropriate requirements of ROHS WEEE Klee te NEE ISTA 1A in carton International Safe Transit Association MEID EE 30 000 hours Ee 3 years parts and labor EE Supplied by the PVS 305SA twisted pair receiver switcher Power input requirements 12 VDC 0 19 A 0 305 A if used with an optional IRCM DV Temperature humidity Storage 40 to 158 F 40 to 70 C 10 to 90 noncondensing Operating 32 to 122 F 0 to 50 C 10 to 90 noncondensing R ck ne E Wall and furniture mountable Enclose EE Plastic faceplate metal rear Enclosure dimensions 00 MLC 104 IP Plus faceplate 4 5 H x 4 6 W x 0 1 D 11 4 cm H x 11 7 cm W x 0 3 cm D MLC 104 IP Plus device 2 7 H x 3 4 W x 1 8 D 6 9 cm H x 8 6 cm W x 4 6 cm D Depth excludes knob and buttons Fits some 2 gang boxes Allow at least 1 9 4 8 cm depth in the wall or furniture PrOGuct WEIGH E 1 9 Ibs 0 9 kg Keele EE ISTA 1A in carton International Safe Transit Association Regulatory compliance DALCLY ai a aRt CE c UL UL EMY Ee CE C tick FCC Class A ICES VCCI ACCESSI DIIY asns EA Complies with the appropriate requirements of Section 508 of the Rehabilitation Act 29U S C 794d ORK 30 000 hours PVT CV D PVT RGB D and PVT RGB D Plus POW ee Supplied by the PVS 305SA twisted pair receiver switcher Power input requirements
62. sed batteries according to the manufacturer s instructions Avertissement Alimentationse Ne faire fonctionner ce mat riel qu avec la source d alimentation indiqu e sur l appareil Ce mat riel doit tre utilis avec une alimentation principale comportant un fil de terre neutre Le troisi me contact de mise a la terre constitue un dispositif de s curit n essayez pas de la contourner ni de la d sactiver D connexion de l alimentation Pour mettre le mat riel hors tension sans danger d connectez tous les cordons d alimentation de l arri re de l appareil ou du module d alimentation de bureau s il est amovible ou encore de la prise secteur Protection du cordon d alimentation e Acheminer les cordons d alimentation de mani re ce que personne ne risque de marcher dessus et a ce qu ils ne soient pas cras s ou pinc s par des objets R paration maintenance e Faire ex cuter toutes les interventions de r paration maintenance par un technicien qualifi Aucun des l ments internes ne peut tre r par par l utilisateur Afin d viter tout danger d lectrocution l utilisateur ne doit pas essayer de proc der lui m me ces op rations car l ouverture ou le retrait des couvercles risquent de l exposer de hautes tensions et autres dangers Fentes et orifices e Si le bo tier de l appareil comporte des fentes ou des orifices ceux ci servent emp cher les composants internes sensibles de surchauffer
63. tcher power supply and any installed optional accessories PVS 305SA PoleVault Switcher PVT RGB D Plus Inputs Voice Lift Lineout Speaker 1 4 A and B Receiver Port Output Output N15779 AMPLIFIED AuDIO OUT T n n 177 E US au VIDEO LISTED API ans VOICELIFT OUTPUTS RECEIVER RGB VIDEO c L R 10V 50mA CONTROL oo Ab be kel TxRxIR 12V PAGING AUX AUDIO RS 232 MLC IR ING L R 4B RGB EN 3VIDEO 4VIDEO INPUT 5 SENSOR VOL MUTE Power Suppl A i di 7 ower Supply RGB Video UX Audio MLC Control Connector PVT CV D Inputs Output Output Input Port 3 and 4 r Paging Sensor Volume Mute Rear View Port Control Port Where it goes PVS 305SA and power supply installs onto the base plate of the PMK 550 What it does Receives input video and audio signals from A V source input wall plates Outputs and switches the signals to projector and ceiling speakers f Cables VGA cable connects to RGB output and projector MVGA M M 3 ft RCA cable connects to video output and projector T TN Se V RCA 3 ft 2 19 PoleVault Systems Installation e Installation Stage A 1 Install the PMK 550 base plate a et The installation must conform to national and local building and electrical codes and UL requirements Refer to the device s user manual for details de The included power supply MUST NOT be N
64. to ensure that it can handle a load four times the weight of the final setup PoleVault Systems Installation e Introduction Planning 1 3 Introduction Planning cont d e Lighting o Type and control important for projector image viewing o Ambient light from windows Student Desks Speaker Location Windows Projector Switcher Location hee MLC Controller Location Teachers Desk TV VCR DVD Inputs PVT A V Wallplate Screen White Board Location Location Example classroom installation b Location of the screen and projector e Proposed screen location o Normally located at the front center of the room not covering fire alarm strobes when screen is lowered o Dimensions and type of screen maximum image size motorized or hanging screen e Proposed projector location Aligned with center of the screen and not an obstruction to viewing Projector s throw distance maximum and minimum limits to the screen of the image Horizontal offset horizontal distance from the center of the lens to the center of the projector Vertical offset of the projected image height relationship between the projector and the screen Projector angle image projected up down or horizontal to screen Power source for the projector existing and accessible or needing installation Projector weight The Universal Projector Bracket UPB 25 supports a maximum weight of 25 lbs O O O O 0 Overhead clearances refer to a copy of
65. trischen Schlags und oder andere Gefahren bestehen Schlitze und ffnungen e Wenn das Ger t Schlitze oder L cher im Geh use aufweist dienen diese zur Vermeidung einer berhitzung der empfindlichen Teile im Inneren Diese ffnungen d rfen niemals von anderen Objekten blockiert werden Litium Batterie e Explosionsgefahr falls die Batterie nicht richtig ersetzt wird Ersetzen Sie verbrauchte Batterien nur durch den gleichen oder einen vergleichbaren Batterietyp der auch vom Hersteller empfohlen wird Entsorgen Sie verbrauchte Batterien bitte gem f den Herstelleranweisungen Advertencia Alimentaci n el ctrica e Este equipo debe conectarse nicamente a la fuente tipo de alimentaci n el ctrica indicada en el mismo La alimentaci n el ctrica de este equipo debe provenir de un sistema de distribuci n general con conductor neutro a tierra La tercera pata puesta a tierra es una medida de seguridad no puentearia ni eliminaria Desconexi n de alimentaci n el ctrica e Para desconectar con seguridad la acometida de alimentaci n el ctrica al equipo desenchufar todos los cables de alimentaci n en el panel trasero del equipo o desenchufar el m dulo de alimentaci n si fuera independiente o desenchufar el cable del recept culo de la pared Protecci n del cables de alimentaci n e Los cables de alimentaci n el ctrica se deben instalar en lugares donde no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos Repa
66. vers of the PMK 550 onto the base plate ensuring the power cable can exit the unit through the power cable access slot Using a 5 32 inch hex wrench tighten down the four screws on the PMK 550 to secure the sides in place Check and tighten the adjuster plate locking screws on the projector bracket Hole plugs can be used to cover any exposed holes in the slotted pipe if necessary PVS 305SA mee Level set too high POLEVAULT SWITCHER O PEAK lower input gain AUDIO LEVEL ADJUST INPUT PEK mio Gre ae NORMAL Level has been roperly adjusted normal Norma properly aaj ou VOICELIFT om SENSITIVITY SIONAL Signal threshold 20 dBV 18 dBu at Kauag aw Slide the covers onto the PMK 550 PoleVault Systems Installation e Installation Stage 5 Optional Accessory Installation VoiceLift System The Extron VoiceLift system is an easy to use low power voice amplification system that ensures the speaker s voice can be clearly heard at a comfortable level throughout the classroom Speech is picked up by the pendant microphone worn by the teacher and is transmitted wirelessly via a base station receiver and the PVS 305SA to the installed ceiling speakers For detailed installation information refer to the VoiceLift Installation Instructions supplied with the device VoiceLift System included parts e VLP 102 pendant microphon

Download Pdf Manuals

image

Related Search

Related Contents

Mode d`emploi  American Standard Cadet Deck-Mount Tub Filler 3985 User's Manual  KitchenAid 8269909 User's Manual  System Configuration LMS-Z620  PM100 Series AC Motor Drive User`s Manual  manuale - Swiminn.com  User Manual - Marvel-tec  Kenmore 5.6 cu. ft. Gas Range w/ True Convection - Black Installation Guide  AVPTC-183014 technic..  デジタルテロッパ EN-NL1068 取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file