Home

Extron electronic Extron Electronics Switch CTR 8 User's Manual

image

Contents

1. View the full firmware The CTR 8 allows A V muting for a selected input This feature allows users to press the selected input button to mute and unmute the audio and video as needed during a presentation e Press the button once to select an input Select state e Press the same button again to activate A V mute De select state e Press the button once more to return to the Select state which selects the input and unmutes the audio and video NOTE The A V mute feature is only triggered by contact closure SIS input selection for example entering 1 two times will not trigger the de select state A V Mute Modes There are three A V mute modes based on the device e Mute mode 1 Mutes switcher input by selecting channel O e Mute mode 2 Mutes video and audio individually e Mute mode 3 Mutes video and sync Mute mode O is the normal default single state operation A V mute is not activated in this mode NOTE See the next page for a partial list of Extron switchers that are compatible with the different mute modes CTR 8 e Remote Communication and Control 8 A V mute modes are activated via SIS commands sent to the CTR 8 The COM port then sends SIS commands to the switcher The table below shows the different commands that the COM port sends for each A V mute mode Button Input Button State Mute mode Number 2 1 Select 1 B Z De select 1B 1Z Select 2 OB OZ De select 1B 1Z Select
2. Always on default 1 Off when muted 2 Blink when muted k25 Baud rate 9600 19200 38400 57600 default 9600 NOTE Unless otherwise indicated commands are not case sensitive Error Messages E 1 Invalid output channel number too large E1 Invalid command E13 Invalid value too large CTR 8 e Remote Communication and Control 7 Command and Response Table for SIS Commands ASCII Command host to unit Select input xo View last selected input l Command Query contact closure status S s Example response Unidirectional Serial Data Port Esc 2 25 n 8 1CP lt Example command Esc 2 19200 n 8 1CP lt Configure port parameters View parameters A V Mute Mode Configure A V mute mode Esc 2CP lt Esc x3 x4 JMUTM lt View A V mute mode setting Ese MUTM lt Other Information request Ti Request part number N n Query firmware version Q q Query full firmware version Q q Reset all device settings to Ese zXXX lt factory A V Muting Response unit to host Chnkko Gl ich 21900000 lt 4 Cpon 2eCcpkk25 n 8 1 lt k25 n 8 1 Mutm x3 x4 lt KajKaj CTRe8 lt t 60 Xxxx xx lt 4 xX xx XXX xxx Zpx lt 4 Additional Description input 0 8 Least significant input on far left Contact input 2 is selected n Parity None 8 Data bits 1 Stop bit View the part number Firmware build 2 decimal places
3. CTR 8 Eight Input Contact Closure to RS 232 Control xt Extron POWER OUT CONT 1 0A MAX EM POWER IN 1 0A MAX IEN 1 2 3 4 5 6 7 8 l LLL Switcher Accessories Module ACT IN TALLY OUT 3 Extron Electronics INTE RFACING SWITCHING AND CONTROL 68 2524 01 Rev A 1213 Safety Instructions Safety Instructions e English WARNING This symbol A when used on the product is intended to alert the user of the presence of uninsulated dangerous voltage within the product s enclosure that may present a risk of electric shock ATTENTION This symbol A when used on the product is intended to alert the user of important operating and maintenance servicing instructions in the literature provided with the equipment For information on safety guidelines regulatory compliances EMI EMF compatibility accessibility and related topics see the Extron Safety and Regulatory Compliance Guide part number 68 290 01 on the Extron website www extron com Instructions de s curit e Fran ais AVERTISSEMENT Ce pictogramme lorsqu il est utilis sur le produit signale utilisateur la pr sence a l int rieur du bo tier du produit d une tension lectrique dangereuse susceptible de provoquer un choc lectrique ATTENTION Ce pictogramme A lorsqu il est utilis sur le produit signale a l utilisateur des instructions d utilisation ou de mainte
4. LATE ERNE mir CAD E Z RRE SER EE SES A HE ER EAT EEA EN ETE AE BEN AZARAE TRIES EMI EMP FAAS PE Ze HCA LE AA AE EA al AlE Extron W i www extron com BEI SP Extron ZEER rr MERI ASE 68 290 01 Japanese SE Corns A PHRLCRRENTUSBAIS BANITHRANT WEBBED TIN RBOCRMNDSCCERLUTWET 8 CORS A PRRLCRRANTUSHBAIS ABHOR c CMAN TWNSBRGRECIAT Bl OFF MIC DUC I 9 O jE BERET SHOTS ZLOTE ART EMLEMESGR COO REIA Ic LYC LIAZKOYOULI 4b www extron com ED Extron Safety and Regulatory Compliance Guide P N 68 290 01 CEE lt TECL Korean aa 0 71s A 7 AZo NSE Be AS SE He AHE Siss Cla ALS GEI A INEA ASE ae sl Ala OFM 2tole sto b i ESI See S24 SOS cela HA Stol Chet AAA et LYS Extron 2 A O E www extron com 2 Extron 97 9 TA ES OKLA E 290 01 FHS YZI FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC rules The Class A limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is
5. enter the requested information then click the Download fw_loader_vnxnxn exe button where n is the Firmware Loader version number 5 Follow the instructions on the rest of the download screens to save the executable Firmware Loader installer file to your computer Note the location to which the file was saved 6 In Windows Explorer or another file browser locate the downloaded executable installer file and double click to open it 7 Follow the instructions on the Installation Wizard screens to install Firmware Loader on your computer Unless you specify otherwise the installer program places the Firmware Loader file FWLoader exe atc Program Files Extron FWLoader CTR 8 Updating Firmware 10 Downloading CTR 8 Firmware Logout D E D p Download Search Q Download Home l Download Center Software Firmware 123 files Dante Controller DSP Configurator Software Global Configurator Global Configurator ML jA B C D E F G H ijI Kk t m NjojP aj RIs T u v wjx Yy z Professional GUI Configurator IP Intercom HelpDesk b Archives Software Pcs Please consult Release Notes for important compatibility information and history TouchLink for iPad XTP System Configuration Software Control System Drivers Firmware Description Part Number Version Date Size Annotator 19 2153 50 2 19 Jul 19 2013 3 3MB Download Firmware for the Annotator 2 modules el Release Notes Resources AVT 100N 19 1532 01 2
6. with tally see page 4 see next page Figure 2 CTR 8 Rear Panel CTR 8 Panels and Cabling 2 ton SST DC power input with loop through Wire the external 12 VDC power MA supply as shown in figure 3 and connect it to the two pole captive screw Power In connector A o S equ GS E Smooth Ridges oa D au SECTION A A i 5 mm Max A Power Supply Output Cord Figure 3 Power Connection mm our The Power Out connector allows power to be looped to an Extron device MAX that uses 12 VDC voltage Follow the same pin diagram above to connect a device to the Power Out connector ATTENTION e Do not tin the wires For best results and to reduce the risk of short circuits trim just 3 16 inch 5 mm of the jacket from the wires If it is any longer the exposed wires may touch causing a short circuit between them If it is any shorter the wires can be easily pulled out even if tightly fastened by the captive screws Always use a power supply supplied by or specified by Extron Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the end product Unless otherwise stated the AC DC adapters are not suitable for use in air handling spaces or in wall cavities The power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location Pollution Degree 2 secured to the equipment rack within the dedicate
7. 3 B Z De select 1B 1Z Select 4 B Z De select 1B 1Z Select 5 OB OZ De select 1B 1Z Select De select Select De select Select 1 2 2 3 3 4 4 5 5 6 6 T T 8 8 O De select NOTES e A V mute commands sent from the COM port B unmute video to the switcher 1B mute video not sync 2B mute video and sync Z unmute audio 1Z mute audio e A V mute mode 0 does not have a De select state The following is a partial list of Extron switchers for A V mute modes 1 2 and 3 NOTE Other switchers and scalers are compatible with the mute modes Contact Extron Technical Support for assistance with your Extron device e Mute mode 1 MLS 608 MPS 602 e Mute mode 2 MLS 608 DSC 301 HD DVS 605 e Mute mode 3 IN1606 IN1608 DSC 301 HD DVS 605 LED Responses for Video Muting The CTR 8 allows button LED responses to indicate when video is muted Button LEDs are controlled by the Tally Output signal The CTR 8 offers three different LED modes which are set by sending SIS commands to the Remote RS 282 port e LED Mode 0 LED of selected input is always on Default e LED Mode 1 LED of selected input turns Off when muted e LED Mode 2 LED of selected input blinks when muted NOTE LED mode can be set only when A V Mute Mode is 1 2 or 3 If AAV Mute Mode is 0 LED mode is O CTR 8 e Remote Communicat
8. The protocol for the RS 232 port is 9600 baud 8 data bits 1 stop bit no parity 9 XY XL Z COM switcher port Connect an Extron switcher to this female captive screw connector as shown below Only connect the Tx and G pins of the CTR 8 The tie Tx G Tx Rx G Transmit Tx Figure 6 COM Input Wiring The protocol for the COM port is 9600 default 19200 38400 or 57600 baud 8 data bits 1 stop bit no parity Application Diagrams Application with Show Me Cables Extron j Contact Closure and Tally CTR 8 Eight Input Contact Closure to RS 232 Control Module OUTPUTS Terme OUTPUTS NN REMOTE Extron IN1606 Scaling Presentation witcher HDMI Video and Embedded Audio Ethernet A S TCP IP Network Contact Closure and Tally Flat Panel Display Ethernet Extron IPL 250 IP Link Control Processor ai a aa i VGA HDMI Show Me Cables CTR 8 Panels and Cabling 4 Application with CCR 4BLB Contact Closure D Power Out Ee 2 EI Extron Ext CTR8 Eremia T E CCR 4BLB Eight Input Contact Closure Four Button Contact Closure to RS 232 Control Module Remote With Customizable Backlit Buttons Three Input Compact HDCP Compliant Video Scaler Power Supply 12V 1A HDMI Video and Embedded Audio Bee DVD Player Flat Panel Display Cable Box The diagram close up below shows how to connect the CCR
9. its quality performance merchantability or fitness for any particular use In no event will Extron Electronics be liable for direct indirect or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage Please note that laws vary from state to state and country to country and that some provisions of this warranty may not apply to you Extron Headquarters 1 800 633 9876 Inside USA Canada Only Extron USA West 1 714 491 1500 1 714 491 1517 FAX Extron USA East 1 919 850 1000 1 919 850 1001 FAX Extron Europe 800 3987 6673 Inside Europe Only 31 33 453 4040 31 33 453 4050 FAX Extron Asia 65 6383 4400 65 6383 4664 FAX Extron Japan 81 3 3511 7655 81 3 3511 7656 FAX Extron China 86 21 3760 1568 86 21 3760 1566 FAX Extron Middle East 971 4 299 1800 971 4 299 1880 FAX Extron Korea 82 2 3444 1571 82 2 3444 1575 FAX Extron India 1800 3070 3777 Inside India Only 91 80 3055 3777 91 80 3055 3737 FAX 2013 Extron Electronics All rights reserved www extron com
10. likely to cause interference the user must correct the interference at his own expense NOTE This unit was tested with shielded I O cables on the peripheral devices Shielded cables must be used to ensure compliance with FCC emissions limits For more information on safety guidelines regulatory compliances EMI EMF compatibility accessibility and related topics see the Extron Safety and Regulatory Compliance Guide on the Extron website Copyright 2013 Extron Electronics All rights reserved Trademarks All trademarks mentioned in this guide are the properties of their respective owners The following registered trademarks registered service marks and trademarks are the property of RGB Systems Inc or Extron Electronics Registered Trademarks AVTrac Cable Cubby CrossPoint eBUS EDID Manager EDID Minder Extron Flat Field GlobalViewer Hideaway Inline IP Intercom IP Link Key Minder Locklt MediaLink PlenumVault PoleVault PowerCage PURE3 Quantum SoundField SoeedMount SpeedSwitch System INTEGRATOR TeamWork TouchLink V Lock VersaTools VN Matrix VoiceLift WallVault WindoWall XTP and XTP Systems Registered Service Mark S3 Service Support Solutions Trademarks AAP AFL Accu Rate Frame Lock ADSP Advanced Digital Sync Processing Auto lmage CDRS Class D Ripple Suppression DDSP Digital Display Sync Processing DMI Dynamic Motion Interpolation Driver Configurat
11. to the serial port If you have not already done so download and install the Firmware Loader executable installer file to your computer see Downloading and Installing Firmware Loader on the previous page If necessary download the latest version of CTR 8 firmware and install it on your computer see the previous section Downloading CTR 8 Firmware Open Firmware Loader The Firmware Loader dialog box opens with the Add Device dialog in front of it CTR 8 Updating Firmware 11 Figure 9 Opening Firmware Loader Inthe Add Device dialog select the device from the Device Names drop down list From the Connection Method drop down list select RS 232 RS 232 Select the appropriate options from the Com Port and Baud Rate menus this information is provided by your system administrator Click Connect If the connection is successful CTR 8 is displayed in green in the Connected Device panel followed by a green check mark Click Browse in the New Firmware File Optional panel In the Open dialog navigate to the new firmware file which has an S19 extension and double click it Search CTR8 P LJ Open Share with Name Date modified Type 1 CTR8V100 0023_B S19 11 25 2013 902 ANM S19 File E Recent Places Libraries E Documents di Music Pictures E Videos PP Computer E Network CTR8V100 0023_B S19 Date modified 11 25 2013 9 03 AM Date created 11 25 2
12. 013 9 03 AM S19 File Size 49 5 KB Figure 10 Open Window for Firmware File Selection ATTENTION Valid firmware files must have the file extension 19 A file with any other extension is not a firmware upgrade for this product and could cause the CTR 8 to stop functioning CTR 8 Updating Firmware 12 NOTES In a e The original factory installed firmware is permanently available on the CTR 8 If the attempted firmware upload fails for any reason the unit reverts to the factory version By default when the firmware is downloaded from the Extron site it is saved in one of the following paths C Program Files Extron Firmware folder_name Windows XP or C Program Files x86 Extron Firmware folder_name Windows 7 where folder_name may be CTR 8 or something similar the Add Device dialog the path to the new firmware file is displayed in the Path field New Firmware File Optional Path C Users csanchez Desktop CTR8 CTR8V100 Browse Aines Figure 11 Path to the New Firmware File on the Add Device Window 10 If this is the only device to which you are uploading firmware click Add The CTR 8 information is added to the Devices section of the Firmware Loader dialog box and the Add Device dialog closes If you want to upload the firmware to multiple units that are connected to your computer do the following a b Click Add Next Your first device is added to t
13. 05 Jan 24 2008 1 9MB amp Download Toner Kl Release Notes Apea Design AVT 100P 19 1533 01 2 05 Mar 15 2012 1 9MB amp Download el Release Notes Figure 8 Firmware Link on the Download Tab To obtain the latest firmware version for the CTR 8 1 Visit the Extron website www extron com click the Download link at the top of the page 2 Click the Firmware link on the left sidebar menu 3 On the Download Center screen locate the section for the CTR 8 firmware 4 Optional click Release Notes These notes show the issues that are addressed by the latest update If these issues do not affect you you may decide not to upgrade the firmware 5 Click the CTR 8 Download link 6 On the next screen enter the requested user information then click Download 7 Follow the instructions on the rest of the download screens to save the executable firmware file to your computer Note the location to which the file was saved 8 In Windows Explorer or another file browser locate the downloaded executable file and double click to open it 9 Follow the instructions on the Installation Wizard screens to install the new firmware on your computer A Release Notes file and a set of instructions for updating the firmware are also loaded Installing Firmware with Firmware Loader To load a new version of firmware to the CTR 8 connect your computer serial port to the Remote port 1 see Remote RS 232 port on page 4 for information on connecting
14. 4BLB to the CTR 8 Ground caTtTwcatwcatwcatw 1 2 3 4 BER 6 7 8 catTwcatwcatwecatw CCR 4BLB Application with Individual Contact Closure Switch Normally Open NO LED PC LED Two Contact Closure Switch AAP Common Resistor R NOTE Determine and select the appropriate Ground C current limiting resistor if needed Some button switches have the resistor built in Normally Closed NC Solder Cups POWER OUT 1 00 MAX COATS CGT CGTV CGT CTR 8 Panels and Cabling 5 Remote Communication and Control This section covers the following e Using Simple Instruction Set SIS Commands e Symbols Used in this Guide e Command and Response Table for SIS Commands e A V Muting Using Simple Instruction Set SIS Commands The CTR 8 is controlled remotely using Extron SIS commands issued from a host computer running the Extron DataViewer utility or other control system The host device is connected to the 3 pole captive screw connector on the rear panel The protocol is 9600 baud 8 data bit 1 stop bit and no parity Host to CTR 8 Communications SIS commands consist of strings one or more characters per command field No special characters are required to begin or end a command sequence When the CTR 8 determines that a command is valid it executes the command and sends a response to the host device Most responses from the CTR 8 end with a carriage return and a lin
15. Street Anaheim CA 92805 U S A Europe and Africa Extron Europe Hanzeboulevard 10 3825 PH Amersfoort The Netherlands Asia Extron Asia Pte Ltd 135 Joo Seng Road 04 01 PM Industrial Bldg Singapore 368363 Singapore Japan Extron Electronics Japan Kyodo Building 16 Ichibancho Chiyoda ku Tokyo 102 0082 Japan China Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China Middle East Extron Middle East Dubai Airport Free Zone F12 PO Box 293666 United Arab Emirates Dubai This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or if modifications were made to the product that were not authorized by Extron NOTE If a product is defective please call Extron and ask for an Application Engineer to receive an RA Return Authorization number This will begin the repair process USA Asia 714 491 1500 or 800 633 9876 65 6383 4400 Europe Japan 31 33 453 4040 81 3 38511 7655 Units must be returned insured with shipping charges prepaid If not insured you assume the risk of loss or damage during shipment Returned units must include the serial number and a description of the problem as well as the name of the person to contact in case there are any questions Extron Electronics makes no further warranties either expressed or implied with respect to the product and
16. d closet podium or desk e The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI NFPA 70 article 75 and the Canadian Electrical Code part 1 section 16 The power supply shall not be permanently fixed to building structure or similar structure Contact closure inputs with tally outputs Connect contact closure source devices to these 4 pole female captive screw connectors Wire each connector as shown in figure 4 NOTES e For Show Me cables the ground pin connection is optional e Do not connect Show Me cables to the V pin Contact C Cen Th Ground G I Q Tally output T L s Tally voltage V Al Om Figure 4 Contact Input Wiring e C Contact input pin Momentary closure of this pin to ground selects the corresponding number input Selection is triggered specifically at the moment of closing not opening e G Ground pin e T Tally output pin controls the LEDs on push buttons When an input is selected only the tally corresponding to that input is active e V Tally voltage output pin optional provides the 5 VDC supply voltage needed to illuminate tally LEDs CTR 8 Panels and Cabling 3 Remote RS 232 port Connect the serial port of a control computer to this female captive screw connector as shown below Transmit Tx T o_a Receive Rx ken D 33 Ground G m rt GI Figure 5 RS 232 Input Wiring
17. duct specifications are available on the Extron website www extron com Contents DEENEN 1 About thE GIR O erreen Hanwontaiwondeerv 1 STEE 1 Panels and Cabling sscssseccsssesesseessreneeees 2 Front Panel Features 2 Rear Panel Features and Cato 2 Application Diagorams 4 Remote Communication and Control 6 Using Simple Instruction Set SIS Commands 6 Host to CTR 8 Communications 0 00 6 CTR 8 Initiated Messages 6 Symbols Used in this Guide 7 Error Messages oriori iennsssaniiininr hia 7 Command and Response Table for SIS r elle EE 8 AIN MIULING E 8 A V Mute MOdES ccccccccececesssteeeesssseeeeeeesas 8 LED Responses for Video Muting eee 9 Updating Firmware cscsscscseeesesseeeseesees 10 Downloading and Installing Firmware Loader 10 Downloading CTR 8 Firmware seee 11 Installing Firmware with Firmware Loader 11 MOUNN g EE 15 Tabletop Placement AAA 15 RACK MOUNTING prere anuetiephaueecnane 15 Under desk and Furniture Mounting 15 EXtron Warranty sescsssviscciscsesscsscsssivsncsnescersccescrss 16 CTR 8 e Contents v Introduction About the CTR 8 Features The Extron CTR 8 control module provides contact closure input switching for most Extron switchers with RS 232 capability It allows simple push buttons to remotely switch and mute audio and video sources The CTR 8 accepts up to eight contact closure inputs and converts them to SIS
18. e feed CR LF ah which signals the end of the response character string CTR 8 Initiated Messages When a local event such as a change in signal status takes place the CTR 8 sends a message to the host indicating the status change No response is required from the host When the CTR 8 is first switched on it sends the message c Copyright 28yy Extron Electronics CTR 8 Vx xx 60 1408 1 lt where 2 yy is the year the currently installed version of the firmware was released and V x xx is the firmware version number CTR 8 e Remote Communication and Control 6 Symbols Used in this Guide When programming in the field certain characters are most conveniently represented by their hexadecimal rather than their ASCII values The table below shows the hexadecimal equivalent of each ASCII character rc mn A An CG u SE DI ON soa S0OQOrvnN D EI A E 1 e Dw See TN Oe Table 1 ASCII to HEX Conversion Table carriage return with line feed carriage return no line feed e space character Esc Escape key The ka values defined in this section are the variables used in the Command Response Table Input 0 8 K Input selection status Not Selected 1 Selected x3 A V mute mode Normal operation no muting default 1 Channel 0 A V mute 0 2 Video Mute 1B and Audio Mute 12 3 Video and Sync Mute 2B Mute LED mode
19. ections other than direct connections Rack Mounting Procedure These units can be mounted an optional rack systems listed on the website see www extron com To mount the unit on a rack shelf follow the instructions provided with the shelf accessories Back of the Rack Mounting Procedure The CTR 8 can be mounted to the rear of a rack using an optional back of rack mounting kit see www extron com The kit allows the product to be vertically mounted to the front or rear rack supports and face either the front or the rear of the rack To mount the unit follow the instructions provided with the kit Under desk and Furniture Mounting Mount the unit under a desk or podium using the included under desk mounting kit Follow the instructions provided with the kit CTR8e Mounting 15 Extron Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase In the event of malfunction during the warranty period attributable directly to faulty workmanship and or materials Extron Electronics will at its option repair or replace said products or components to whatever extent it shall deem necessary to restore said product to proper operating condition provided that it is returned within the warranty period with proof of purchase and description of malfunction to USA Canada South America and Central America Extron Electronics 1230 South Lewis
20. he Devices section of the Firmware Loader dialog box and the Add Device dialog remains open For each additional device you want to add repeat steps 4 through 9 then click Add Next For the last device click Add instead of Add Next to add the device and to close the Add Device dialog CTR 8 Updating Firmware 13 Ke EE EC K File Edit Options Help KSE Transfer Time Total Progress Remaining Time 00 00 00 Elapsed Time 00 00 00 Device 1 Device Name Part Number Current Firmware Version 60 1408 01 Figure 12 Firmware Loader Screen with the CTR 8 Added 11 If you want to remove a device do the following a Click the names of the devices to be deleted to highlight them b Select Edit gt Remove Selected Device s from the toolbar c Onthe Remove Device s window select or deselect any devices on the list as desired then click Remove To remove all devices select Edit gt Remove All Devices from the toolbar 12 Click Begin The following indicators show the progress of the update e The Transfer Time section shows the amounts of remaining and elapsed time for the update e The Total Progress section displays a progress bar with Uploading above it e Inthe Devices panel the Progress column displays an incrementing percentage and another progress bar The Status column displays Uploading 13 The upload is complete when the Remaining Time field shows oo op og the Progress column
21. ion and Control 9 Updating Firmware Updates to the CTR 8 firmware are released periodically on the Extron website You can find which version is currently loaded on your CTR 8 using SIS commands Compare this with the latest release on the Extron website and decide whether to update your firmware TIP Read the Release Notes provided on the website with the latest firmware to determine whether you need the latest version This section covers the following Downloading and Installing Firmware Loader Downloading CTR 8 Firmware Installing Firmware with Firmware Loader Downloading and Installing Firmware Loader Extron recommends using the Firmware Loader software to update the firmware on Extron products If you do not already have Firmware Loader installed on your computer download it as follows 1 Go to the Extron website at www extron com and click the Download link 2 Click the Software link on the left sidebar menu 3 On the Download Center page locate Firmware Loader and click its Download link Firmware Loader 79 508 01 5 1 Jul 20 2012 13 5 MB Extron Firmware Loader is a oomputer software applioation that allows you to update Extron produots with field upgradable firmware The software supports firmware updates to Extron produots oonneoted via USB serial RS 232 or addressable on your looal area network LAN gt Learn More J Release Notes ES Figure 7 Firmware Loader Download Link 4 On the next screen
22. nance importantes qui se trouvent dans la documentation fournie avec le mat riel Pour en savoir plus sur les r gles de s curit la conformit a la r glementation la compatibilit EMI EMF l accessibilit et autres sujets connexes lisez les informations de s curit et de conformit Extron r f 68 290 01 sur le site Extron www extron com Sicherheitsanweisungen e Deutsch WARNUNG Dieses Symbol A auf dem Produkt soll den Benutzer darauf aufmerksam machen dass im Inneren des Geh uses dieses Produktes gef hrliche Spannungen herrschen die nicht isoliert sind und die einen elektrischen Schlag verursachen k nnen VORSICHT Dieses Symbol A auf dem Produkt soll dem Benutzer in der im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung Instandhaltung geben Weitere Informationen Uber die Sicherheitsrichtlinien Produkthandhabung EMI EMF Kompatibilitat Zuganglichkeit und verwandte Themen finden Sie in den Extron Richtlinien f r Sicherheit und Handhabung Artikelnummer 68 290 01 auf der Extron Website www extron com Instrucciones de seguridad e Espa ol ADVERTENCIA Este s mbolo A cuando se utiliza en el producto avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del producto lo que puede representar un riesgo de descarga el ctrica ATENCI N Este s mbolo A cuando se utiliza en el producto avisa al usuario de la presencia de importantes in
23. or DSP Configurator DSVP Digital Sync Validation Processing FastBite FOXBOX IP Intercom HelpDesk MAAP MicroDigital ProDSP QS FPC QuickSwitch Front Panel Controller Scope Trigger SIS Simple Instruction Set Skew Free SpeedNayv Triple Action Switching XTRA ZipCaddy ZipClip Conventions Used in this Guide Notifications The following notifications are used in this guide ATTENTION Attention indicates a situation that may damage or destroy the product or associated equipment NOTE A note draws attention to important information Software Commands Commands are written in the fonts shown here AR Merge Scene Op scene 1 1 B51 W C G1 R 4 BOID GG400 BOBBO GBEBSD 02 35 17 G3 Ese x1 x17 k20 x23 x21 CE lt lt NOTE For commands and examples of computer or device responses mentioned in this guide the character is used for the number zero and 0 is the capital letter o Computer responses and directory paths that do not have variables are written in the font shown here Reply from 208 132 180 48 bytes 32 times 2ms TTL 32 C Program Files Extron Variables are written in slanted form as shown here ping XXX XXX XXX XXX E SOH R Data STX Command ETB ETX Selectable items such as menu names menu options buttons tabs and field names are written in the font shown here From the File menu select New Click the OK button Specifications Availability Pro
24. serial commands that select the corresponding input on an Extron switcher e Eight contact closure inputs with tally allow remote switching and selection status using simple push button control e COM switcher port sends SIS commands to the Extron switcher for input switching and muting e A V muting allows the user to mute a switcher output by consecutively pushing the same input button e 5 VDC output on each contact closure input is used to light an LED indicating input selection e Remote RS 232 port for remote control using Extron Simple Instruction Set SIS commands e DC power input with loop through allows one power supply to power the CTR 8 and an additional Extron device CTR 8 Introduction 1 Panels and Cabling This section covers the following e Front Panel Features e Rear Panel Features and Cabling e Application Diagrams Front Panel Features 4 Power LED Lights green when the unit is receiving power Figure 1 CTR 8 Front Panel Rear Panel Features and Cabling The following section covers rear panel features and cabling procedures If mounting is necessary before connecting cables see the Mounting section on page 15 POWER OUT CONTACT IN TALLY OUT 1 0A MAX CATH CGATH CGATH CG Ta 1 2 3 4 xl E switcher port 12V POWER IN 7 8 EA 232 see page 4 Power o Connectors i CGTwWcCGT W CGT wz CGT HA DU see next page Contact inputs Remote RS 232 port
25. shows 188 and Completed is displayed above the progress bar and in the Status field Close the Firmware Loader dialog CTR 8 Updating Firmware 14 Mounting Tabletop Placement Attach the four provided rubber feet to the bottom of the unit and place it in any convenient location Rack Mounting UL Guidelines for Rack Mounting The following Underwriters Laboratories UL guidelines are relevant to the safe installation of these products in a rack e Elevated operating ambient temperature If the unit is installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient temperature Therefore install the equipment in an environment compatible with the maximum ambient temperature TMA 122 F 50 C specified by Extron e Reduced air flow Install the equipment in the rack so that safe operation and adequate air flow is provided to the unit e Mechanical loading Mount the equipment in the rack so that a hazardous condition is not achieved due to uneven mechanical loading e Circuit overloading Connect the equipment to the supply circuit and consider the effect that circuit overloading might have on overcurrent protection and supply wiring Consider the equipment nameplate ratings when addressing this concern e Reliable earthing grounding Maintain reliable grounding of rack mounted equipment Pay particular attention to supply conn
26. strucciones de uso y mantenimiento recogidas en la documentaci n proporcionada con el equipo Para obtener informaci n sobre directrices de seguridad cumplimiento de normativas compatibilidad electromagn tica accesibilidad y temas relacionados consulte la Guia de cumplimiento de normativas y seguridad de Extron referencia 68 290 01 en el sitio Web de Extron www extron com Wxnctpykuua no TexHuke GesonacHoctTn e Pycckn DPEDNDIDEKDEHME Danuupp cumBon A ecnu yKasaH Ha npogykte npeszynpexgaeT NONb3OBATENA O HANNYNN HeEUZONUPOBAaHHOrO onacHoro Hanps KeHUA BHYTPU KOpNyca npogykta KOTOPOe MOxeT DDMBGCTH K NOpakKeHUIO NEKTpNYECKNM TOKOM BHMMAHME Daunpp cumeon A ecnn yKasaH Ha NposyKte npegynpexgaeT NONb3OBATENA O HANNYNN BadkKHbIX MHCTDNKUAD no kcnnyataynn n O CNYKNBAHNIO B PyKOBOACTBe npunaraemom K AAHHOMY O6OpyYAOBaAHNIO Dna nonyyenna nuoopmaynn o npaBunax TexHUKU Dez2OnaCHOCT co6ntogeHun HOPMATNBHbIX Tpe6oBaHUi NEKTPOMATHNTHO cosmectumoctn MN AC BO3MOxHOCTM gocTyna n Apyrnx BONpocax CM PyKOBOACTBO NO 6eE3onNaCHOCTN N CO6NOAEHNIO HOpPMAaTNBHbIX Tpe6oBaHn Extron Ha Cape Extron www extron com HoMep no Katanory 68 290 01 Chinese Simplified ik BS Aangel RANSREM EM BE AMEE SS AP RLHEARRBERTAPRSMNNAA SEPA BEM EMA EE LA F ll p le AMIE EMEM HAE FA GAWSESHAAR WGA Extron Muh www extron com Zb Extron ZEA r iSb 68 290 01 Chinese Traditional FPX SS Aen L