Home

Energizer ER-PRO1400 User's Manual

image

Contents

1. z ER PRO1400 Git Power Protection Congratulations on your new Energizer ER PRO1000 UPS Power Protection system This product is specifically designed for home office and workstation applications With the newest technology this series can operate under a wide range of input utility power while maintaining steady output voltage Why is this important Some equipment requires consistent backup power under high utility fluctuation Because the number of computer peripherals increase all six outlets provide surge protection and battery back up to protect your printer scanner or other peripheral devices from surges spikes and electromagnetic interference Your box should include the following UPS unit and Input Power Cord User s Manual Telephone Line Communication Connection Cord Remote Monitoring Software Specifications Color Black Waveform Type Stepped Sinewave Run Time 6 60 Joules surge capacity 1482 z EEEE Features ena ME Overload Protection Yes Compact light weight design Battery Backup Outlets l Intelligent microprocessor control Warranty 3 years Recharge Time typical lt 8hrs of 90 Unparalleled communication with your computer internet Ready Phone Fax p40 148 mance A Provides accurate information for control and Modem hookups g monitoring power Overload protection and alarm Smart AVR for low and high input line voltage Fax modem surge suppression port VA Rating 1400 Audible Indicators 4 Connecte
2. FileSaver software in CD ROM drive on computer and follow instructions 3 Plug your modem or fax line into the UPS OUT line and your computer into the IN line Plug the included USB cable from the UPS data port to the USB port on your computer HE Computer phone line to UPS IN plug Modem or fax line to UPS OUT plug Use your battery backup sockets for computer monitor and external storage devices i e zip drive For surge protection plug in non essential equipment such as printers scanners and speakers Do NOT use your UPS for laser printers vacuums space heaters copiers or shredders Trouble Shooting Problem UPS will not turn on LED is not lit UPS system is remaining on battery mode UPS is functioning normally but the computer will not turn on Available backup time is less than the indicated rating The UPS system is continually beeping The Site Wiring Fault LED is on Your communication function is not working oa DATA PORT SITE WIRE FAULT Cause Your On Off switch was not pushed in completely Your battery voltage is too low Your power cord is loose Your input fuse has been blown Your circuit breaker has been tripped Your line voltage is too high or too low Your computer input power cord is loose or disconnected Your battery is not fully charged or your battery is dead Your UPS system is slightly overloaded Your UPS system is overloaded Your UPS system has aut
3. d Equipment Watts 910 3 Years i a Guarantee Site Wiring Fault indicator Input Output Voltage 115 Unit Dimensions Weight 14 6 x 5 9 x 8 3 Easy battery replacement mechanism Frequency 60 Compliance CUL Interface Port USB or Serial RJ48 Cord Length 6 feet Panel Indicator Description On Off Switch Turns UPS system on amp off AC Normal On Battery Indicator Indicate the AC is normal or that the UPS is in battery mode Buck Mode Indicator OVERLOAD Boost Mode Indicator Measures and restores normal AC voltage if it is too high Measures and restores normal AC voltage if it is too low Overload Abnormal Indicator SITE WIRE FAULT Indicates the UPS output is overloaded or that there is UPS failure DATA PORT CIRCUIT Input Circuit Breaker BREAKER AC INPUT or AC Fuse Backup Power FAX MODEM Surge Protection Outlets Data Port Network Connections Protect against UPS system overload Provide output power to computer device and a noise filtering function to computer peripherals Allows remote monitoring and control via serial interface ports Provides Network DSL Internet Connection protection Telephone Surge Protection Port Suppress the spike voltage on the telephone line AC Power Inlet Site Wire Fault Indicator Connects to input utility power through the input power cord Indicate missing ground or polarity reversed Installation 1 Insert
4. d or exposure to a harsh environment will reduce the actual lifetime Charge the internal battery every three 3 months to recover the self discharge capacity that is caused when the unit is in extended storage When replacing your battery ensure that your new battery meets the required specifications Proper disposal of batteries is required Refer to your local codes for disposal requirements Battery Replacement Lay the unit on its side Use a screwdriver to open the battery cover on the bottom of the unit Grasp the tab attached to the battery and slide the battery out Storage Instructions Your unit should be stored in a cool dry location Make sure that the internal battery is fully charged before storage For extended storage in moderate climates the battery should be charged for 12 hours every three 3 months by plugging the power cord into the wall outlet and turning on the main switch Repeat every two 2 months in high temperature locations How do you get service Call 1 866 337 6937 for help Can use this product for life support We do not recommend the use of our products for life support equipment or direct care where failure of the product could cause failure or diminished effectiveness of the life support equipment or patient care Software installation 1 Insert FileSaver CD into CD ROM The software will execute automatically 2 If the software can not perform properly please press Start and execut
5. e the D setup exe
6. nty cover We warrant this product to be free from defects in material and workmanship during the warranty period If a product proves to be defective in material or workmanship during the warranty period we will at our option repair or replace the product with an equivalent model How long is the warranty effective Energizer Power Protection products are warranted for 3 years for all parts and labor from the date of the first consumer purchase What does the warranty NOT cover 1 Any product on which the serial number has been defaced modified or removed 2 Damage deterioration or malfunction resulting from accident misuse neglect fire water lightening or other acts of nature unauthorized product modification or failure to follow instructions supplied with the product 3 Repair or attempt to repair by anyone who is not authorized 4 Any damage of the product that occurred during shipping 5 Installation of the product 6 Any damage that results from the installation of the product 7 Use of supplies or parts not meeting indicated specifications 8 Normal wear and tear 9 Any other cause which does not relate to a product defect Servicing and Replacing the Battery Routine Maintenance Use dry soft cloths to clean the front panel and plastic parts Do not use any detergent that contains any alcohol ingredient The expected lifetime of the internal battery is around three 3 years Improper operation an
7. omatically defaulted to battery mode Your polarity is reversed or another electrical issue You are using the wrong interface cable 2 Plug your Energizer ER PRO1400 UPS Power Protection system into a wall outlet SITE WIRE FAULT DATA PORT CIRCUIT BREAKER QO AC INPUT FAX MODEM ele dii UPS OUTPUT B NETWORK Plug all equipment to the plugs in the back of the UPS SITE WIRE FAULT computer monitor printer speaker other DATA PORT CIRCUIT BREAKER O UPS OUTPUT AC INPUT FAX MODEM Solution Press and hold the On Off switch for 3 seconds or until you hear a beeping sound Call 1 866 337 6937 for help Ensure that the cord is plugged in firmly Remove some loads devices and replace fuse with similar rating Reset circuit breaker Check your input voltage Reconnect your computer input power cord Recharge the battery for 6 hours and retest the backup time If problem persists call 1 866 337 6937 for help Remove the least critical load device Remove the non critical loads devices Remove non critical loads devices and restart the UPS system Call an electrician to check and service your wiring Ensure that you have the correct interface cable or obtain one from your local retailer For any additional questions or questions concerning the FileSaver software please visit www energizerups com or call 1 877 267 4687 Warranty What does the warra