1. 2 09 Rev 0 Printed in USA 81155 Installation 0 950 24 13 060 0 196 4 98 2x 0 951 24 14 060 1 563 39 69 1 450 _ 36 83 9 05 93 68 Emerson Network Power HB Ac Power HB Embedded Computing Ml Outside Plant E Racks and Integrated Cabinets The global leader in enabling E connectivity H Embedded Power HB Power Switching amp Control W services Business Critical Continuity E 0c Power E Monitoring H Precision Cooling a Surge Protection Emerson Network Power Contact information Headquarters Surge Protection 328 Water Street 650 SW 27th Avenue Binghamton NY 13901 Ocala FL 34471 T 607 721 8840 T 352 732 3029 T 800 288 6169 T 800 648 4076 F 607 722 8713 F 352 867 1237 E contactsurge emerson com www emersonnetworkpower com EMERSON Network Pc Business Critical Continuity Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co 2009 Emerson Electric Co
2. E Surge Protection Islatrol INXT120NLO00 1 For Business Critical Continuity AC Power Line Filter The Islatrol INXT120NLO00 1 is a 120 VAC 60A EMI RFI filter The INXT is a series connected device designed to filter electrical type transients impinging A on electrical distribution of a traffic control cabinet NEUTRAL s EMERSON Une Islatrol nx AC Power Filter INXT120NL000 1 120VA 60A 50 60Hz 1D 4508 C General Technical Specifications Part Number Islatrol INXT120NL000 1 Nominal Operating Voltage 120 VAC Operating Voltage Range 120V 25 Features Operating Frequency Range 47 63 Hz Connection Type 1 4 20 Studs E 60 Amp Series Filter Amperes 60 Amperes A E 50 dB attenuation 200 KHz to 75 MHz Phase Configuration Single Phase 2 wire Line and Neutral aS IET KAE KI E High impact thermoplastic enclosure Weight 2 Ibs Maximum Continuous Operating Voltage 150 VAC MCOV WE Epoxy encapsulated Load Surge Current Rating eee Sous E 5 year limited warranty 5 SEC 2 x Nominal Transient Reduction Frequency Attenuation 50 dB min 200 KHz to 75 MHz Packaging Black high impact plastic case Operating Temperature 40 C to 45 C derate linearly to 70 70 C Operating Humidity 0 to 95 non condensing Operating Altitude 100m to 2000m Certifications IEG610 Complies with the requirements of UL1283 Warranty 5 Years bs EMERSON 10 30110
Download Pdf Manuals
Related Search
Related Contents
Honeywell HMLCD17L User's Manual Mode d`emploi - Octagon アイテム詳細データ【PDFファイル】 Manual de instrucciones EOS USER'S GUIDE 5DX PLUNGER PUMP SERVICE MANUAL Avaya 1600 Series IP Deskphones Application Note banc d`essai Qobuz Copyright © All rights reserved.
Failed to retrieve file