1. EMERSON mag Air Comfort Products DIVISION OF EMERSON COMPANY 8100 W Florissant St Louis MO 63136 Part No F40BP72240002 Printed in Taiwan 08 00 Form No BP7224 2
2. 2 ZAMN Figure 3 9 The blade flanges have an interlocking feature that must be fully engaged before tightening the screws Make sure all the flanges are properly engaged and then tighten the flange screws If one of the flanges does not seat properly on the motor hub loosen the adjacent flange screws re engage and reseat the flanges then tighten the screws again Engage the connector of the switch housing assembly with the motor connector Figure 4 The two connectors are keyed and color coded and must be mated correctly color to color before they can be engaged Make sure the con nector latch closes properly SWITCH HOUSING J ASSEMBLY Sam m lt U SWITCH HOUSING a 0 CONNECTOR n i jS TA CTE CONNECT Z N SoS 11 Remove the three switch housing mounting screws Figure 4 from the switch housing plate Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate Secure the switch housing assembly by installing the three mounting screws Figure 5 Figure 4 ANN NOTE Do not pinch wires between the switch housing assembly and the switch housing plate SWITCH HOUSING ASSEMBLY MOUNTING SCREWS 3 l anA A AN 12 You have now completed the assembly of your new ceiling fan You can now proceed with hang ing and wiring your fan Electrical Requirements Your new ceiling fan wi
3. If you are uncertain of part description refer to exploded view illustration Fan motor assembly One switch housing assembly Five fan blades One ceiling cover Five blade flanges One hanger ball downrod assembly One hanger bracket One loose parts bag containing 1 Sixteen 3 16 24 x 1 4 slotted Phillips blade screws Sixteen blade washers Eleven 1 4 20 x 1 2 Phillips oval head flange screws One wood pendant One coupling Three wire connectors Two threaded studs Two lockwashers Two knurled knobs One clevis pin One hairpin clip TO r rODQA0 08 OOONDOF w ye _ eh NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local retail er or catalog outlet for replacement before proceeding 2 Remove the fan assembly from the protective plas tic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly LOOSE PARTS FAN MOTOR HANGER BALL DOWNROD ASSEMBLY gt HANGER BEANGES EX BRACKET CEILING COUPLING SWITCH CUP COVER COVER ASSEMBLY FAN BLADES 1 How to Put Your Ceiling Fan Together A WARNING To reduce the risk of personal injury do not bend the Pass the 80 motor leads through the opening in the ceiling cove
4. Raise coupling cover and tighten setscrew and jam nut securely 2 Tighten the setscrew in the hanger ball downrod assembly 3 Check to be sure screws which attach the fan blade flanges to the motor are tight 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 5 Tighten the hanger bracket screws to the outlet box and or secure outlet box 6 Interchanging an adjacent side by side blade pair can redistribute the weight and result in smoother operation Repair Parts Listing Model No Description CF705WW03 CF705PB03 CF705AB03 CF705W03 CF705WPB03 CF7050B03 Hanger Ball Assembly 760750 3 760750 1 760750 760750 2 760750 3 760750 36 760750 34 760750 37 Consisting of Hanger Bracket Hanger Ball Downrod Parts Bag Containing 761936 761936 3 761936 1 761936 3 761936 3 Wire Connector 3 Threaded Stud 2 Lockwasher 2 Knurled Knob 2 Blade Washer 16 Pin Clevis Clip Hairpin Coupling Chain Wood Pendant Screw 1 4 20 x 1 2 11 Screw 3 16 24 x 1 4 16 Ceiling Canopy 760169 760169 1 760169 2 760169 3 760169 760169 24 760169 20 760169 25 Wiring Harness 761543 1 761543 761543 2 761543 761543 1 761543 2 761543 1 761543 2 Flange set of 5 761933 761933 1 761933 2 761933 3 761933 1 761933 4 761933 5 761
5. 933 6 Blade set of 5 761930 761930 1 761930 1 761930 2 761930 761930 3 761930 4 761930 5 Switch Housing 761935 761935 1 761935 2 761935 3 761935 761935 4 761935 5 761935 6 Owner s Manual BP7224 2 BP7224 2 BP7224 2 BP7224 2 BP7224 2 BP7224 2 BP7224 2 BP7224 2 Oona 1 WO DM Model No Description CF705NW03 CF705BS03 CF705S03 CF705AW03 Hanger Ball Assembly 760750 29 760750 24 760750 38 760750 41 Consisting of Hanger Bracket Hanger Ball Downrod Parts Bag Containing 761936 3 761936 2 761936 1 Wire Connector 3 Threaded Stud 2 Lockwasher 2 Knurled Knob 2 Blade Washer 16 Pin Clevis Clip Hairpin Coupling Chain Wood Pendant Screw 1 4 20 x 1 2 11 Screw 3 16 24 x 1 4 16 Ceiling Canopy 760169 19 760169 15 760169 26 760169 32 Wiring Harness 761543 761543 3 761543 2 761543 1 Flange set of 5 761933 7 761933 8 761933 9 761933 13 Blade set of 5 761930 6 761930 12 761930 8 761930 13 Switch Housing 761935 7 761935 8 761935 9 761935 13 Owner s Manual BP7224 2 BP7224 2 BP7224 2 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION e PART NUMBER e NAME OF ITEM e PART DESCRIPTION e MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545
6. COVER THREADED STUD LOCKWASHER KNURLED KNOB Figure 10 A WARNING To avoid possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling C 6 Cut the 3 speed switch pull chain to a desired length optional Connect the wood pendant supplied to the 3 speed switch pull chain by sliding the wooden pendant small hole first onto the pull chain Attach the chain coupler to the end of the chain and allow the wooden pendant to fall down over the coupling Using Your Ceiling Fan 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 Check the operation of the fan by gently pulling on the pull chain switch 3 All fans are shipped from the factory with the reversing switch positioned to circulate air down Your fan model is equipped with a 4 position 3 speed pull chain switch The operating sequence is as follows THREE SPEED ward If airflow is desired in opposite direction turn 1st PullL HIGH oe your fan off and wait for the blades to stop turning ond Pull Medi SWITCH Bo een i then slide the reversing switch to opposite position ae eon SWITCH and turn fan on again The fan blades will turn in 3rd Pull Low the opposite direction and reverse the airflow 4th Pull OFF Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Perio
7. READ AND SAVE THESE INSTRUCTIONS 52 NORTHWIND Model No Ceili ng Fan CF705WW03 CF705PB03 CF705AB03 CF705WPB03 I Owner s Manual cr7oswo3 CF7050B03 CF705HTW03 CF705TGO3 Net Weight 14 4 Lbs CF705NWO03 CF705BS03 CF705S03 CF705AWO3 LIMITED WARRANTY What The Warranty Covers This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials You must be the original purchaser or user of the product to be covered What The Period Of Coverage Is As it applies to the motor this warranty will last for twenty years from the date you purchased your ceiling fan All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR What Will Emerson Company Do To Correct Problems Emerson Company will replace a defective Emerson Air Comfort Ceiling Fan motor blade component or other accessory at no charge to you If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided Emerson will refund the actual purchase price of your fan We will ship the repaired product or replacement to you at no charge but you are responsible for all costs or removal reinstallation and shipping of the produ
8. anual carefully and keep it for future reference Before servicing or cleaning unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel Be careful of the fan and blades when cleaning painting or working near the fan Always turn off the power to the ceiling fan before servicing Do not put anything into the fan blades while they are turning Do not operate reversing switch until fan blades have come to a complete stop Additional Safety Instructions for Installation To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades All wiring must satisfy National and Local Electrical Codes Use the National Electrical Code if Local Codes do not exist The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a
9. ble fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket Figure 9 How to Wire Your Ceiling Fan If you feel that you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician A WARNING To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is ground ed contact a licensed electrician for advice as it must be grounded for safe operation 1 Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply this may be a bare wire or wire with green colored insulation Securely connect wires with wire con nectors supplied Figure 9 NOTE If you are using an Emerson Light Fixture with your fan see Light Fixture Owner s Manual for wiring A WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or acces sories not designated for use with this product by Emerson Company could result in personal injury or property damage C 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 9 Securely connect the fan m
10. ct to Emerson Company How Can You Get Service YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE You can return the product to our factory or to your nearest authorized service center e To return the product to the factory obtain a return authorization and service identification tag by writing to Air Comfort Products Division of Emerson Co 8100 W Florissant Ave St Louis MO 63136 Include all model numbers shown on the product with your request e To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by e Repairs by persons not authorized by Emerson Company e Use of parts or accessories not authorized by Emerson Company e Mishandling improper installation modifications or damage to your ceiling fan while in your possession or e Unreasonable use misuse abuse including failing to do reasonable and necessary maintenance and norma
11. d branch circuit fuses or circuit breakers Check line wire connections to fan and switch switch wire connections in the switch housing wire connections in the switch housing WARNING Make sure main power is turned off Make sure reversing switch position is all the way to one side Blades not attached to fan Screws securing fan blade flanges to motor are loose Wire connectors inside switch housing rattling 2 Fan sounds noisy Motor noise caused by solid state variable speed control Screws holding blades to flanges are loose 3 Fan wobbles 1 Setscrew and jam nut in motor coupling are not excessively tightened securely 2 Setscrew in the hanger ball downrod assembly is loose 3 Screws securing fan blade flanges to motor are loose 4 Fan blade flanges not seated properly 5 Hanger bracket and or ceiling outlet box is not securely fastened 6 Fan blades out of balance Attach blades to fan before operating Check to make sure the screws which attach the fan flanges to the motor are tight Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned off Some fan motors are sensitive to signals from Solid State variable speed controls If Solid State Control is used and motor noise results choose an alternative control method Tighten screws securely 1
12. dic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish A WARNING Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock Accessories 1 Ceiling Fan Light Kits see store or catalog 2 Ceiling Fan Light Controls see store or catalog 3 Downrod Extension Kits see store or catalog A WARNING The use of any other control not specifically approved for this fan could result in fire shock and personal injury A WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or acces sories not designated for use with this product by Emerson Company could result in personal injury or property damage a WARNING For your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan Trouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1 Fan will not start Fuse or circuit breaker blown Loose power line connections to the fan or loose switch wire connections in the switch housing Reversing switch in neutral position Check main an
13. l wear and tear Additionally this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when e The original purchaser or user ceases to own the product or e The fan is moved from its original point of installation This warranty is only valid within the 50 states of the United States and the District of Columbia No other written or oral warranties apply and no employee agent dealer or other person is authorized to give any warranties on behalf of Emerson Company REPAIR REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES Incidental damages include but are not limited to such damages as loss of time and loss of use Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly How State Law Relates To The Warranty Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Part No F40BP72240002 Form No BP7224 2 A WARNING WARNING To avoid fire shock and serious personal injury follow these instructions Safety Instructions Read your owner s m
14. ll require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capa ble of withstanding a load of at least 50 pounds 2 WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked acceptable for fan support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not accept able for fan support and may need to be replaced Consult a qualified electrician if in doubt If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture 5 Figure 7 A WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electri cal shock A WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician How to Hang Your Ceiling Fan A WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 6 b CEILINGZ T AT LEAST 7 Figure 6 FLOOR OOOO 4 WARNING The outlet box must be securel
15. otor black wire and blue wire to the supply black hot wire using wire connector supplied Figure 9 6 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box NOTE CEILING COVER BLACK AND BLUE OMITTED FOR CLARITY al Grounn FANWIRES WIRE LISTED WIRE CONNECTOR 3 WHITE SUPPLY NEUTRAL GREEN WIRE GROUND FROM HANGER BRACKET AmE FAN GREEN WIRE GROUND FROM HANGER BALL BLACK SUPPLY HOT A WARNING Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result 3 Screw the two threaded studs supplied into the tapped holes in the hanger bracket 4 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 10 5 Secure the ceiling cover in place by sliding lockwash ers over the threaded studs and installing the two knurled knobs supplied Figure 10 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod Your fan is now wired to be turned on and off from the fan switch CEILING
16. qualified electrician if in doubt The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To avoid fire shock or injury do not use an Emerson or any other brand of control not specifically approved for this fan WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage WARNING To Reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades DATE CODE The date code of this fan may be found on the box stamped in ink on a white label You should record this data above and keep it in a safe place for future use This Manual Is Designed to Make it as Easy as Possible for You to Assemble Install Operate and Maintain Your Ceiling Fan Tools Needed fo
17. r Be sure the cover is oriented correctly Figure 1 Separate untwist and unkink the three motor leads Route the motor leads through the hanger ball downrod assembly Align the clevis pin holes in the downrod with the holes in the motor coupling Install the clevis pin and secure with the hairpin clip Figure 1 The cle vis pin must go through the holes in the motor cou pling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved por tion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to pre vent the clevis pin from working loose Pull on the hanger ball to make sure the clevis pin is properly installed 4 WARNING It is critical that the clevis pin in the motor coupling 3 16 24 x 1 2 SCREW WITH JAM NUT Figure 1 4 is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed could result in the fan falling MOTOR COUPLING HANGER BALL DOWNROD ASSEMBLY PIN A Back off the jam nut until it rests loosely against the setscrew head Install the setscrew in the motor coupling Figure 1 and tighten securely while pulling up on the downrod Using a 5 16 inch open end wrench or pliers tighten the jam nut securely against the motor coupling NOTE The setscrew and jam nut m
18. r Assembly One Phillips head screwdriver One stepladder One 1 4 blade screwdriver One wire stripper One 5 16 open end wrench or pliers Three wire connectors supplied MATERIALS Wiring outlet box and box connectors must be of type required by the local code The minimum wire would be a 3 conductor 2 wire with ground of following size Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 A WARNING Before assembly your ceiling fan refer to section on proper method of wiring your fan page 6 If you feel you do not have enough wiring knowledge or experi ence have your fan installed by a licensed electrician Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted A WARNING Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 A WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or acces sories not designated for use with this product by Emerson Company could result in personal injury or property damage 1 Check to see that you have received the following parts NOTE
19. ust be properly installed as described above or fan wobble could result 5 J6 The fan comes with blue black and white leads that are 80 inches long Before installing the fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads Mount blade flanges to fan blades using three 3 16 24 x 5 16 slotted Phillips screws and three blade washers Figure 2 E 10 4 Figure 2 blade flange when installing the blade flanges bal ancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades 3 16 24 x 1 4 SLOTTED PHILLIPS EW 3 BLADE WASHER 3 NOTE Take care not to scratch fan housing when installing blades NOTE Remove and discard the four shipping S 7 8 pacers and screws from the motor hub Turn the fan assembly upside down in preparation for mounting the fan blade assemblies Rotate the motor hub until the flange screw hole is next to the cutout in the switch housing plate Attach one blade assembly to the motor hub using two 1 4 20 x 1 2 Phillips oval head flange screws Make sure the screws are NOT tightened Figure 3 Repeat this procedure for the other four blade assemblies BLADE FLANGE LT SE SS 1 4 20 x 1 2 PHILLIPS OVAL MOTOR HUB Cig U fom lt gt HEAD FLANGE SCREWS
20. y anchored and capable of with standing a load of at least 50 Ibs 4 WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked acceptable for fan support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not accept able for fan support and may need to be replaced Consult a qualified electrician in in doubt 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 7 A WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket con tacts box If bracket and or outlet box are not securely attached the fan could wobble or fall mors OUTLET l th fe ee BOK TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 8 Be sure the groove in the ball is lined up with tab on the hanger bracket Figure 7 4 WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard a NOTE CEILING COVER SUPPLY WIRES AND Z oo eX M 1 OA FAN WIRES OMITTED _ ro o FOR CLARITY i S a HANGER BRACKET Figure 8 HANGER BALL DOWNROD ASSEMBLY 4y WARNING To avoid possi