1. simulates a real world load The LPS features a durable water resistant and lightweight remote Hand Held Controller This controller is user friendly and controls the functions of the entire system The controller displays Volts Amps Frequency KW KVAR KVA and Power Factor along with any alarm conditions The LPS System is integrated on a rugged structural steel skid with provisions for overhead four point lifting The LPS load bank system is ideal for high power resistive and reactive testing of AC generating systems in factory production lines or in the field after installation LPS 1875 KVA Portable Resistive Reactive Avtron Load Bank A EMERSON Network Power Avtron LPS Resistive Reactive High Capacity Portable Load Bank 937 5 to 2500 KVA Specifications subjectto change without notice Construction Typical Capacity Ratings The system consists of individual resistive and Total Load reactive load banks and a load connection KVA at Resistive Reactive ad Bank Weight approx box factory mounted on a rugged structural 0 8 p f Load KW Load KVAR steel skid All load bank exterior panels are SPa 13 000 Ibs 5900 kg constructed out of aluminized steel for supe 937 5 750 562 5 rior corrosion protection Hot air exhaust is 1250 1000 750 Options rtical f l Bethe ERE 1562 1250 937 5 SIGMA Network Control Controls i r The entire system is controlled by a rugged 183 1500 ues 400 Hz
2. Avtron LPS Resistive Reactive High Capacity Portable Load Bank 937 5 to 2500 kva Testing Your Emergency Standby Generator with a Load Bank Means Reliability When it Matters Most Key Features e Resistive and Reactive Loading e Outdoor Weatherproof Design Single Point Load Connection e Modern Hand Held PLC Controller e Aluminized Steel Construction e Vertical Air Discharge Superior Avtron quality combined with simple operation and maintenance will provide years of trouble free service Avtron s extensive line of Load Bank and Industrial Resistor Products are solid performers used throughout the world For total technical support or additional information please contact Avtron at 216 573 7600 or LBsales Emerson com Quality System Certified to ISO 9001 Av TRON The Avtron Model LPS Load Bank is ideal for high power resistive reactive testing of AC power systems The Avtron LPS Load Bank System provides an economical and convenient means for high capacity resistive and reactive loading of AC power systems such as diesel generator sets turbines or Unin terruptible Power Supplies UPS Many specifications and local codes demand that such testing be performed at less than unity power factor typically 0 8 p f lagging To achieve a 0 8 power factor the LPS combines resistive load KW with reactive load KVAR This combination provides a true test of the actual generator or UPS nameplate rating KVA and
3. Designs Available compact 7 x 7 x 2 lightweight Hand Held 2500 2000 1500 Controller The controller is easy to operate and load values are activated by pressing a membrane style keypad All resistive reac tive jog and blower functions are displayed NOTE Standard voltage is 480 VAC 3 Phase 60 Hz Other voltages and frequencies are available Consult factory onan LCD display A hard wired E Stop push STAINLESS STEEL yoy button is provided on the controller The con PRANTE EXHAUST HATCHES x troller communicates to load bank PLC via a REACTIVE LOAD BANK 200 cable with an MS style connector m Resistor Elements TS The resistive elements are manufactured rom corrosion resistant chromium alloy wire 03200 and are fully supported on stainless steel rods or long life 97 00 2464 00 63 00 1600 00 Reactive Elements moore th E 1 The reactive elements are non saturating e o F12 00 308 00 single and 3 phase iron core reactors im m EREET 255 00 6477 00 pregnated with high dielectric varnish LOAD CONNECTION ENCLOSURE RESISTIVE LOAD BANK Cooling APPROX WIDTH 76 00 1930 00 The LPS resistive elements are cooled by two integrally mounted fan motors each rated 10 HP 460 VAC 3 phase 60 Hz Protection The LPS features branch circuit fusing on all load steps and overtemperature protec tion Air switches on the fans are electrically inte
4. rlocked to remove load if air flow is not sufficient to provide proper cooling All dimensions are in inches millimeters Emerson Consider it Solved and Emerson Network Power are trademarks of Emerson Electric Co E Emerson Network Power or one of its affiliated companies All the other marks are the property of their respective owners Avtron 6255 Halle Drive Cleveland Ohio 44125 U S A Communicator EXT is a trademark of Electro Industries GaugeTech ADMS is a trademark of Avtron e 216 573 7600 FAX 216 573 5953 LBsales Emerson com SIGMA is a trademark of NJ Froment amp Co Ltd Specifications subject to change without notice EmersonNetworkPower com loadbank 2015 Emerson Network Power Bulletin 426 Rev B EMERSON CONSIDER IT SOLVED
Download Pdf Manuals
Related Search
Related Contents
Aérogénérateur Bornay 1500 User manual IBM Cognos Express Advisor Version 10.1.0: User Guide The service manual has been restructured to add a “Low TELÉFONO CELULAR CON DOBLE TARJETA SIM Diplomarbeit von Katalin Biró C 280 / S 280 C 310 / ST 310 OWNER`S MANUAL Worldwide Lighting W83098C28 Instructions / Assembly Copyright © All rights reserved.
Failed to retrieve file