Home
EMC LPE11002EG User's Manual
Contents
1. SS EMULEX We network storage LPe11002 HBA Installation Manual lt EMULEX We network storage Copyright 2005 Emulex Corporation All rights reserved worldwide No part of this document may be reproduced by any means nor translated to any electronic medium without the written consent of Emulex Corporation Information furnished by Emulex Corporation is believed to be accurate and reliable However no responsibility is assumed by Emulex Corporation for its use or for any infringements of patents or other rights of third parties which may result from its use No license is granted by implication or otherwise under any patent or patent rights of Emulex Corporation Emulex and LightPulse are registered trademarks and AutoPilot Installer AutoPilot Manager BlockGuard FibreSpy HBAnyware InSpeed MultiPulse SLI and SBOD are trademarks of Emulex Corporation All other brand or product names referenced herein are trademarks or registered trademarks of their respective companies or organizations Emulex provides this manual as is without any warranty of any kind either expressed or implied including but not limited to the implied warranties of merchantability or fitness for a particular purpose Emulex Corporation may make improvements and changes to the product described in this manual at any time and without any notice Emulex Corporation assumes no responsibility for its use nor for any infringements of patents or other right
2. any other electronic system When applying for system level certification to electronic standards such as IEC950 the regulatory engineers may want to see the DHHS and European conformity labeling on the small form LPe11002 Hardware Installation Manual Page 13 TS EMULEX factor transceiver and the system level documentation and labeling Copies of the certificate of conformity for any small form factor transceiver sold by Emulex can be obtained upon request from Emulex Corporation Costa Mesa LPe11002 Hardware Installation Manual Page 14
3. or higher PCle bus slot Press firmly until the adapter is seated Secure the HBA s mounting bracket to the case with the panel screw or clip Replace the computer case and tighten case screws The HBA is now installed in the PC and is ready for media attachment LPe11002 Hardware Installation Manual Page4 lt EMULEX Attaching Media Note The HBA will not allow normal data transmission on an optical link unless it is connected to another similar or compatible laser product that is multimode to multimode Use multimode fiber optic cable with short wave lasers that adheres to the following specifications Table 3 Media Specifications Fiber Optic Cable Maximum Length Minimum Length Connector 62 5 125 um multimode 300 meters at 1 0625 Gb s 5 meters LC 200 MHz km bandwidth 150 meters at 2 125 Gb s cable 70 meters at 4 25 Gb s 50 125 um multimode 500 meters at 1 0625 Gb s 5 meters LC 500 MHz km bandwidth 300 meters at 2 125 Gb s cable 150 meters at 4 25 Gb s To attach media to the HBA 1 Connect the fiber optic cable to the LC connectors on the HBA Figure 3 Connecting Fiber Optic Cables 2 Connect the other end of the cable to the Fibre Channel device After the media is connected to the HBA you are ready to apply power to the computer LPe11002 Hardware Installation Manual Page 5 gt gt EMULEX Applying Power To apply power 1 Verify that the HBA is securel
4. other operating systems Some drivers support both SCSI and IP protocols e Support for remote and fabric boot functionality On board context management by the firmware per port Up to 510 FC port logins e Up to 1023 concurrent exchanges O multiplexing down to the FC frame level e Data buffers capable of supporting 16 buffer to buffer BB credits for short wave applications Link management and recovery handled by the firmware On board diagnostic capability accessible via optional connection e Parts and construction compliant to the European Union Directive of Restriction of Hazardous Substances RoHS Compatibility Table 1 Software and Hardware Environments Software Environments Windows 2000 Server Windows Server 2003 Novell NetWare Sun Solaris Linux and HP UX Hardware Environments PCI Express 1 0a compliant systems Prerequisites e PCI Express 1 0a compliant systems x1 or x4 lane transfer link interface at 2 5 Gb s per lane 3 3 V power from PCle slot is required for operation Setting the Jumpers Caution Emulex LightPulse amp HBAs contain electronic components that can be damaged by static electricity through an electrostatic discharge ESD event To prevent ESD damage maintain constant contact with any grounded metal surface A grounding wrist strap is useful for this purpose Handle the card carefully at all times and preferably by the edges Avoid touching electronic components an
5. used when configuring your system The serial number is used when communicating with Emulex All numbers are clearly marked on the board We recommend that you record these numbers before installation 2 Turn off and unplug the computer LPe11002 Hardware Installation Manual Page 3 e gt gt EMULEX Remove the computer case Note For best I O performance place the adapter into an empty PCle x4 or higher slot PCle slots are shorter than standard PCI 64 bit slots Do not attempt to plug the adapter into a standard PCI slot Remove the blank panel from an empty PCle bus slot Follow steps 5 8 to change the bracket if they are different sizes Otherwise skip to step 9 Note The HBA comes with a standard PCI bracket installed A low profile bracket is included in the box with the HBA The low profile mounting bracket is shorter than the standard bracket approximately 3 11 in 7 9 cm compared to 4 75 in 12 06 cm long Remove the mounting bracket screws from the top of the HBA Figure 2 Removing the Bracket 6 T 10 11 Remove the bracket and store it for future use Align the new mounting bracket tabs with the holes in the HBA Note Be careful not to push the bracket past the transceiver housing s grounding tabs Make sure the light emitting diodes LEDs are properly aligned with the holes in the bracket Replace the screws that attach the HBA to the bracket Insert the HBA into the empty x4
6. 002 Class A Japan VCCI Class A Taiwan BSMI Class A Korea MIC Class A LPe11002 Hardware Installation Manual Page 8 lt EMULEX FCC and Regulatory Notices LPe11002 HBA Models This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Responsible Party Paul Folino Chief Executive Officer Emulex Corporation 714 662 5600 3333 Susan St Costa Mesa CA 92626 USA Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The reader is cautioned that changes or modifications made to the equipment not expressly approved by Emulex could void the user s authority to operate this equipment The above statement applies to prod
7. A is Emulex s eighth generation FC controller The controller incorporates a multifunction native PCle core that is compliant to the PCle Base Specification 1 0a and PCI Express CEM Specification 1 0a The HBA supports packet transfers up to 2048 bytes on the PCle link with support for x1 or x4 lane negotiation The supported physical PCle connector is x4 or higher x8 or x16 The two independent fully featured FC ports are compliant to various American National Standards Institute ANSI FC standards The product is targeted at FC storage networking environments that require the highest degrees of robustness performance and ease of management Major Features Multifunction PCle device with two fully independent FC ports e Auto negotiation between 1 Gb 2 Gb or 4 Gb link attachments High performance FC HBA with the PCle to FC controller with two internal processors e Full support for all FC topologies including point to point arbitrated loop and fabric e Full support for FC service class 2 and 3 Maximum FC throughput achieved via full duplex hardware support End to end data path parity and cyclical redundancy check CRC protection including internal data path random access memory RAM e Architectural support for multiple upper layer protocols State of the art circuitry All PCle and FC functionality contained within a single custom high density fully inte grated FC controller nternal ARM 1136J S processors with i
8. EX le network storage Yellow LED Green LED State Slow Blink Slow Blink Off line for download Fast Blink Slow Blink Restricted off line mode Waiting for restart Flashing Slow Blink Restricted off line mode Test active LPe11002 Hardware Installation Manual Page 7 References Specifications SE EMULEX le network storage Table 5 LPe11002 Specifications Parameter Range Media Interface The controller interfaces to the physical media through an FC 0 Media Interface FC PI compliant transceiver and then connects through dual optical fiber LC connectors Physical Dimensions Low profile MD2 form factor 6 600 inches by 2 536 inches and accommodates both the full height and low profile bracket Power Requirements In a PCle x4 slot e 5 9 watts typical 3 3 VDC 8 5 watts maximum 3 3 VDC Airflow 100 If min minimum Temperature 32 to 131 F 0 to 55 C Operating 40 to 158 F 40 to 70 C Storage Humidity 5 to 95 non condensing Agency Approvals for LPe11002 Class 1 Laser Product per DHHS 21CFR J amp EN60825 1 UL recognized to UL60950 1 2003 CUR recognized to CSA 22 2 No 60950 1 03 Baurt certified by TUV to 60950 1 FCC Rules Part 15 Class A Industry Canada ICES 003 Class A EMC Directives 89 336 EEC and 2004 108 EC CE Mark EN55022 Class A EN55024 Australian EMC Framework C Tick Mark ASINZS CISPR22 2
9. adapters The small form factor transceiver is the primary cable connection mechanism for any optical port on the host adapter This data is not intended to be a replacement for any safety regulations and standards relevant safety documents should always be consulted if necessary Contact Emulex Corporation with any questions or concerns about laser safety Certification and Classification The LPe11000 LPe11002 and LPe1150 host adapters may contain a laser product known as a small form factor transceiver This transceiver provides the physical connection to the optical cable and its LC style connector extends through the mounting bracket In turn the host adapter can be inserted into any host system s appropriate PCI PCI X expansion slot In the United States all optical small form factor transceivers sold by Emulex are certified as Class 1 laser products that conform to the requirements contained in the Department of Health and Human Services DHHS regulation 21 CFR subchapter J The certification is indicated by a label located on the optical small form factor transceiver In Europe all optical small form factor transceivers sold by Emulex are certified as Class 1 laser component assemblies that conform to the requirements contained in the CENELEC European Committee for Electrotechnical Standardization standard EN60825 1 1994 including amendment 11 and EN60825 2 1994 Small form factor transceivers are certified by a recognized European t
10. d keep the card in the original packaging until you are ready for installation The device ID jumpers are used in custom applications Do not change the jumper settings for a standard Emulex installation LPe11002 Hardware Installation Manual Page 2 The host adapter has two six post jumper blocks one jumper block for each port that control the host adapter s device ID The ID is selected by installing a jumper between posts 1 and 2 or 3 and 4 or 5 and 6 If no jumper is installed the default device ID is 1AE5 Port 0 is the top transceiver and port 1 is the bottom transceiver Table 2 Jumper Settings Port 0 and Port 1 PCI Identifier PO JX Port 0 P1 JX Port 1 FEOO 1 2 1 2 FEO1 3 4 3 4 1AE5 5 6 5 6 Note Without a jumper the HBA reports a device ID of 1AE5 Most software drivers require a PCI device ID of FEOO to properly identify and control the HBA Do not attempt to operate the HBA with the PCI device ID set to 1AE5 unless recommended by the driver installation instructions Jumper Settings Figure 1 The LPe11002 Jumper Settings Installing the Host Bus Adapter To install the HBA 1 Each HBA is shipped with a unique 64 bit identifier called the IEEE address The FC industry uses a World Wide Name WWN derived from the IEEE address and this number is needed for FC connectivity Since this adapter has two ports there are two IEEE addresses The IEEE address is
11. esting agency and have appropriate markings on the assembly The DHHS conformity label and European conformity mark will not be visible externally once the optical small form factor transceiver is connected to or inserted in the host adapter and the adapter is installed into a system Labeling Requirements No caution or danger labels are required for use of the small form factor transceiver since they are Class 1 laser component assembly In the U S the only laser safety label required is the DHHS certification label that already appears on the small form factor transceiver In Europe the EN60825 1 EN60825 2 standards require that the system level product has a Class 1 information label permanently attached and clearly visible whenever access to the GLM GBIC 1x9 and small form factor transceiver optical port is possible Each Class 1 product shall have affixed an explanatory label bearing the words CLASS 1 LASER PRODUCT LPe11002 Hardware Installation Manual Page 12 Ts EMULEX Alternatively at the discretion of the manufacturer the same statement may be included in user information If a label is used an example of the IEC Class 1 information label that is suitable for most European countries is shown below The label consists of black printing on a white background Languages represented on this label are English German Finnish and French and they represent the minimum set for acceptance of a Class 1 product in most European c
12. ion Technology Equipment ITE Product Safety UL Recognizedto UL 60950 1 2003 First Edition CUR Recognized to CSA22 2 No 60950 1 03 IEC 60950 1 2001 CB Scheme EN 60950 1 2001 All EN 60825 1 1994 Al A2 EN 60825 2 1994 CFR Title 21 Laser AEL Class 1 FDA CDRH EMC FCC Rules CFR Title 47 Part 15 Subpart B Class A Industry Canada ICES 003 Class A EN55022 1998 CISPR 22 1997 Class A EN55024 1998 AZINZS CISPR22 2002 Class A VOCI V 2 V 3 Class CNS 13438 1997 Class A KN22 2000 Class A KN24 Supplementary 1 The Product was tested in a typical configuration Information 2 The product complies with the requirements of the following directives European Union Low V oltage Directive 73 23 EEC e European Union EMC Directives 89 336 EEC and 2004 108 EC CE Marking Directive 93 68 EEC C arries the CE Mark accordingly e Australian EMC Framework Carries the C Tick mark accordingly June 13 2005 e Costa Mesa CA VED AA Faul Folino Chief Executive Officer European Contact eect Die ee Telephone 44 118 977 2929 orest Court 3 Oaklands Paxk Fax 44 113 977 3237 Fishponds Road Wokingham Berks hie RG41 2FD England LPe11002 Hardware Installation Manual Page 11 e Pac EMULEX Laser Safety Notice This laser safety information contains certification and product information covering laser products known as optical small form factor transceivers incorporated in Emulex LightPulse host
13. n they are connected to another compatible laser product Short wavelength and long wavelength small form factor transceivers embedded in Emulex host adapter are non OFC For non OFC links a compatible laser device must be non OFC and certified as a Class 1 laser product Any system level product that incorporates the small form factor transceivers must provide power supply protection that guarantees a voltage of 5 0 volts or less at the small form factor transceivers The functional power supply range of the small form factor transceivers product is specified as 3 135 to 3 465V typically Operation outside of this range may degrade the performance and lifetime of the transceiver The transceiver will remain operational with laser emissions below Class 1 limits provided the power supply level at the adapter remains at or below 5 0 volts If the power supply level rises above 5 0 volts the small form factor transceiver cannot be guaranteed to operate correctly and could result in laser emissions that may exceed Class 1 limits System Level Certification All host adapters containing embedded small form factor transceivers are certified as Class 1 laser products within the U S and Class 1 laser component assemblies outside of the U S Manufacturers of products properly incorporating the small form factor transceiver do not need to recertify their product for laser safety The procedure for full system certification is therefore identical to that used for
14. nstruction and data cache for each port e Internal serializer deserializer SerDes 1 Gb 2 Gb 4 Gb cores for FC and 2 5 Gb cores for PCle e Complies with the PCle base and CEM 1 0a specifications x1 or x4 lane link interface auto negotiated with system at 2 5 Gb s e Supports VCO 1 Virtual Channel and TCO 1 Traffic Class e Configuration IO Memory read write completion and message e Supports 64 bit addressing ECRC for all transmitted PCle data packets Link CRC on all PCle packets and message information e Supports large payload size 2048 bytes for read write e Supports large read request size 4096 bytes Internal high speed static RAM SRAM e Error correcting code ECC protection of local memory including single bit correction and double bit protection The LPe11002 HBA provides two embedded short wave optical LC connections with link diagnostics capability LPe11002 Hardware Installation Manual Page 1 gt gt EMULEX Host interface via Emulex standard drivers or through custom drivers written to the Emulex Service Level Interface SLI 2 that is compatible with the many existing Emulex drivers for products such as LP8000 LP9002L LP9802 LP10000 HBAs Comprehensive array of operating system OS drivers Emulex standard and OEM derivatives of device drivers for Windows 2000 Server Win dows Server 2003 Novell NetWare Sun Solaris Linux and HP UX e OEM specific drivers for AIX and some
15. ountries CLASS 1 LASER PRODUCT LASER KLASSE 1 LUOK AN 1 LASERLAITE APPAREIL amp LASER DE CLASSE 1 Product Information Small Form Factor Transceiver The small form factor transceiver is an integrated duplex data link for bi directional communications over multimode or single mode optical fiber Each small form factor transceiver consists of a transmitter and receiver optical subassembly The transmitter subassembly contains a semiconductor laser emitting in the wavelength range of 770 to 860 nanometers for shortwave length small form factor transceivers and 1270 to 1355 nanometers for long wavelength small form factor transceivers For non OFC links the optical power from the laser transmitter is controlled and maintained at a lower power level The power emitted from either an open fiber or open laser transmitter is guaranteed to be below the Class 1 limit Class 1 laser products are not considered hazardous No user maintenance service operations or adjustments can be performed the small form factor transceiver Usage Restrictions Failure to comply with these usage restrictions may result in incorrect operation of the system and could possible lead to points of access that may emit laser radiation levels above the Class 1 limits established in the U S by the DHHS and within Europe by EN60825 1 EN60825 2 Short wavelength and long wavelength small form factor transceivers allow normal data transmission on the optical link whe
16. s of third parties that may result Periodic changes are made to information contained herein although these changes will be incorporated into new editions of this manual Emulex Corporation disclaims any undertaking to give notice of such changes LPe11002 Hardware Installation Manual Page ii 21e EMULEX Table of Contents 2a EMULE INtrodUGtioni s ivuriiiiiaga ebano ahi darla EET 1 MajoriFeatureS iuuiaicaai 1 Compatibility creati sai alia rali alia 2 Prerequlsites rei oto e oet lariana iaia 2 Setting the Jumlp6rs c ataca aiar aiat E kid ast a bed dc dt ri da c i ids eta eda d a Add 2 Installing the Host Bus Adapter redo e oet ER LOIRE in 3 prz terio 5 Applying POW i reor och esae rd aee ai iaia 6 Viewing the LEDS ttd ache plc dac cec o rea coe abc d andae epa he n eu dc ddr 6 POST Conditions and Results critt Ernte c rr ED HDD e OR ais 6 pii qm HM 8 Specifications asic EA 8 FCC and Regulatory NOuCes iss i222 obtineri retenti Ho ce ater ebd sven ili 9 Declaration of Comfonmity ct 2 ote T bere ER I E D eda ai 10 Laser Satety NOUCE sp 12 LPe11002 Hardware Installation Manual Page iii lt EMULEX Introduction The Emulex LPe11002 host bus adapter HBA is a dual channel 4 25 gigabit per second Gb s Fibre Channel FC Peripheral Component Interconnect Express PCle HBA The core technology of this HB
17. terference in which case users will be required to correct the interference at their own expense Notice for South Korea and Translations MIC ASI E 2 2 lls H898 HIIS ESS 2 IVOCL Ser 2 elo mola SS SHAM uieje aos DESAI BIELICIH Translation Class A Equipment Please note that this equipment has been approved for business purposes with regards to electromagnetic interference If purchased in error for use in a residential area you may wish to exchange the equipment where you purchased it Declaration of Conformity LPe11002 HBA This equipment complies with CISPR22 EN55022 Class A WARNING This is a class A product In a domestic environment this product may cause radio interference requiring the user to take adequate measures Note Changes or modifications not expressly approved by Emulex Corporation could void the user s authority to operate this equipment LPe11002 Hardware Installation Manual Page 10 2S EMULEX INP Da EMULEX DECLARATION OF CONFORMITY We network storage Manufacturer Emulex Design and Manufacturing Corporation 3333 Susan Street Costa Mesa California 92626 USA declares under sole responsibility that the product Product Name LightPulse Fibre Channel Host Bus Adapter Models LPe11002 M4 LPe11000 M4 LPe1150 F4 Assembly Number FC1120005 XX FC1110406 X X To which this Declaration relates is in conformity with the following standards or other documents for informat
18. ucts marketed in the USA This class A digital apparatus meets all requirements of the Industry Canada IC Interference Causing Equipment Standard ICES 003 Cet appareil numerique de la Classe A respecte toutes les exigences du reglement sur le materiel brouilleur du Canada This statement applies to products marketed in Canada Notice for Japan and Translations VCCI Product Label This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures VCCI A CIEME TAATBEUSIYnEREUCY MENA ENTE cum EIEG5BsEITIEmaeuuid nmm iiuggemcu cae ERTS RDEREMS LEO BUET VCCI Manual Notice Translation This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions CORRI PLES ES TAMER eR VECI Oe CEJ SAAR ETT CRE CERA TER TALE WE T cua Va TT CORSA ME EE amp ct5SshkeHnaccausuiEd LPe11002 Hardware Installation Manual Page 9 Pac EMULEX Notice for Taiwan and Translations BSMI Zoe SNITZ gt VE for and gt WieisHsCTH C found Shae HE RARKS BRIN Translation This equipment is a Class A ITE and operation of this equipment in a residential area is likely to cause harmful in
19. y installed in the computer Verify that the correct media is attached 2 3 Plug in and turn on the computer 4 Observe LEDs for Power On Self Test POST results Viewing the LEDs Green and yellow LEDs can be seen through openings in the HBA s mounting bracket Green indicates firmware operation and yellow signifies port activity Each port has a corresponding set of green and yellow LEDs Port 0 LEDs M r e LEDs di Figure 4 LEDs POST Conditions and Results POST conditions and results are summarized in the following table Note For the Link Rate conditions there is a 1 Hz pause when the LED is off between each group of fast blinks 1 2 or 3 You should observe the LED sequence for several seconds to ensure that the pause is correctly identified Table 4 POST Conditions and Results Yellow LED Green LED State Off Off Wake up failure Dead board On Off POST failure Dead board Slow Blink Off Wake up failure monitor Fast Blink Off POST failure Flashing Off POST processing in progress Off On Failure while functioning On On Failure while functioning 1 Fast Blink On 1Gb Link rate Normal link up 2 Fast Blinks On 2Gb Link rate Normal link up 3 Fast Blinks On 4Gb Link rate Normal link up Off Slow Blink Normal link down or not started LPe11002 Hardware Installation Manual Page 6 Table 4 POST Conditions and Results Continued SE EMUL
Download Pdf Manuals
Related Search
Related Contents
BWLC OPR Documentación de apoyo al auto aprendizaje del MC68000 PDF - 6,5 Mb - Regione Veneto LOG WINDOW (4.03.04) Users Manual "取扱説明書" NanoDrop 3300 ver. 2.8 Users Manual 日本語 (3.7 Bedienungsanleitung SG4 Extended Sistema di trasmissione STar™ microTargeting ATCA-7368 Basic Blade Services Programmer`s Reference Copyright © All rights reserved.