Home
Electrolux E32AF75FPS User's Manual
Contents
1. 79 H x 66 W with minimum cabinet side panels of 25 1 4 D x 3 4 W e Minimum 25 1 4 depth requires recessed electrical outlet and water line Note For planning purposes only Refer to Product Installation Guide on the web at electroluxicon com for detailed instructions Electrolux Major Appliances N A USA e 250 Bobby Jones Expressway Augusta GA 30907 1 877 4electrolux 1 877 435 3287 e electroluxicon com Pr iLiad Apia gl sedi os io change CANADA e 5855 Terry Fox Way Mississauga ON L5V 3E4 1 800 265 8352 electroluxicon ca specifications or discontinue models without notice AFARLVRKIT INST 09 09 2009 Electrolux Home Products Inc Printed in the U S A
2. 33 C 25 min A 79 B 66 C 251 4 min Water Supply Hookup ae Minimum depth from face of cabinet side panels and requires recessed electrical outlet and water line For All Freezer All Refrigerator Side by Side Installation Ice maker Note Refer to detailed Louvered Trim Kit Installation connection instructions included with kit or on web Water filter connection Recessed water line Recessed All Freezer units only electrical outlet Note For single unit installation direct plumbing to ice maker recommended Top View Refer to web for details on R Pn ice maker water efrigerator supply hookup Z a Cabinet Side rr 3 4 min width All Freezer and All Refrigerator Optional Louvered Trim Kits Specifications e To use Single Louvered Trim Kit PN SFRRSRKIT or PN SRRRSRKIT e Cabinet or soffit above unit must extend out to same depth as an enclosure is required around All Freezer or All Refrigerator having an side panels opening of 79 H x 33 W with minimum cabinet side panels of e Minimum 7 x 8 clear floor space required for Single Trim Kit assembly 25 1 4 D x 3 4 W a minimum 10 x 8 clear floor space required for Double Trim Kit assembly e To use Double Louvered Trim Kit PN DUORSRKIT an enclosure is e For detailed All Freezer and All Refrigerator installations refer to required around All Freezer and All Refrigerator having an opening of model specific product page and installation guide on web
3. A Electrolux E3S2AF75FPS profes ICON if N N AN O na AR O rie Q arik a ML i X N WY Built In Side by Side Configuration Shown with companion All Refrigerator model E32AR7FPS and optional coordinated Double Louvered Trim Kit DUORSRKI 7 d ape Shown with optional coordinated Single Louvered Trim Kit SFRRSRKIT PureAdvantage Air Filtration System Yy Continuously filters the circulated air to maintain yy a fresher cleaner interior A status light alerts YY d when the filter needs to be replaced then with 23 one touch the filter exchange is made simple and easy Theatre Lighting Transition lighting that is so thoughtfully designed that it gradually illuminates the interior of the freezer with soft but ample light Smooth Glide Full Extension System Freezer storage drawers slide in and out with ease extending completely for convenient access to stored food i Tilt Out Wire Door Bins gt Help you store a variety of frozen food items m in a smaller space hes BUILT IN ALL FREEZER CAPACITIES Total Capacity Total Shelf Area INTERIOR CONVENIENCES PureAdvantage Air Filter SpillSafe Sliding Glass Shelves Fixed Glass Shelf Smooth Glide Full Extension Storage Drawers 3 Position Adjustable Storage Drawer Dividers per Drawer Tilt Out Tall Doo
4. bottom rear i Dn includes cabinet plus 24 w 4 riser 7 32 hinge Shown with optional 4 trim kit riser Allow at Note Optional Louvered Trim Kits available for Built In All Freezer For specifications refer to Louvered Trim Kits Installation page on web Minimum depth from face of cabinet side panels and requires recessed electrical outlet and water line 32 Built In All Freezer Specifications e Product Weight approx 266 Lbs e An electrical supply with grounded three prong receptacle is required The power supply circuit must be installed in accordance with current edition of National Electrical Code NFPA 70 and local codes amp ordinances e Voltage Rating 115V 60 Hz 15 or 20 Amps e Connected Load kW Rating 115 Volts 0 55 kW e Amps 115 Volts 5 Amps e Always consult local and national electric amp plumbing codes e Minimum opening of 66 H x 33 W x 25 1 4 D required for single unit Built In Look installation 66 W required for double unit installation 66 H to be measured from finished floor to underside of soffit or overhead cabinet e Remove all wall floor molding prior to built in installation e Water filter system for ice maker is located in All Refrigerator model E32AR7FPS For side by side installation refer to web for details on ice maker water supply hookup If All Freezer unit is to be installed alone direct plumbing recommended e Minimum 25 1 4 depth requir
5. es recessed electrical outlet and copper water line Electrolux Major Appliances N A USA 250 Bobby Jones Expressway Augusta GA 30907 1 877 4electrolux 1 877 435 3287 electroluxicon com CANADA e 5855 Terry Fox Way Mississauga ON L5V 3E4 1 800 265 8352 electroluxicon ca E32AF75FPS 09 09 2009 Electrolux Home Products Inc e Water line can enter opening through floor or rear wall Copper tubing recommended between cold water line and water connection location Water line tubing recommended is 48 minimum length by 1 4 diameter Installation of easily accessible shutoff valve in water line required e To allow for ease of moving out side by side units after installation 84 minimum length of coiled copper tubing recommended e When installing next to wall where handle may make contact allow 4 minimum clearance for 90 door swing At 90 door stop position drawer access will be maintained but removal will be restricted e Freezer must be placed on level surface of hard material same height as flooring Surface must support approximately 600 lbs when fully loaded Unit equipped with 4 point leveling e f optional Single or Double Louvered Trim Kit is to be used different cutout dimensions are required Refer to cutout dimensions on this page and to Louvered Trim Kits Installation Specifications page on web Note For planning purposes only Refer to Product Installation Guide on the web at electrol
6. r Wire Bin Tilt Out Short Door Wire Bins White Adjustable Door Bins Interior Light with Dual 40W Short Blue Bulbs Theatre Lighting Mid Level Lighting with Dual 25W Short Blue Bulbs Dynamic Cool Digital Temperature Control System Ice Maker Door Closer UltraQuiet Sound Package ADDITIONAL FEATURES ENERGY STAR ACCESSORIES Single Louvered Trim Kit PN SFRRSRKIT Double Louvered Trim Kit PN DUORSRKIT SPECIFICATIONS Overall Exterior Dimensions Height Not Including 21 32 hinge cover Cabinet Cabinet Including Optional Trim Kit Riser Width Depth Including Door with 90 Door Open Voltage Rating Connected Load kW Rating 115 Voltst Power Cord Location Water Inlet Location Shipping Weight Approx Water filtration for All Freezer ice maker located in All Refrigerator 16 8 Cu Ft 17 Sq Ft Yes N N 1 2 2 Yes Yes Yes Yes Yes Yes Yes Yes Optional Optional 65 1 8 69 1 4 min 70 1 4 max 32 26 3 4 57 1 4 115V 60Hz 15 or 20A 0 55 Right Bottom Rear Left Bottom Rear 297 Lbs An electrical supply with grounded three prong receptacle is required The power supply circuit must be installed in accordance with current edition of National Electrical Code NFPA 70 and local codes amp ordinances NOTE Always consult local and national electric and plumbing codes Refer to Product Installation Guide for detailed installation ins
7. tructions on the web at electroluxicon com Specifications subject to change Optional Trim Kits Single Louvered Trim Kit SFRRSRKIT For single All Freezer installation Includes louvered top grille and vented louvered toe kick 4 riser with leveling system and side top trim pieces Double Louvered Trim Kit DUORSRKIT For All Freezer All Refrigerator side by side installation Includes full width louvered top grille and vented louvered toe kick two 4 risers with leveling systems and side top trim pieces electroluxicon com Built In All Freezer E32AF75FPS professional series Recessed water line Top View Cabinet Side Panels 3 4 min width with Louvered Trim Kit i f ur A Cutout Dimensions ee Built In All Freezer Built In All Freezer without Trim Kit amp Riser Single Unit Installation A 66 B 33 C 25 min Double Unit Side by Side Installation A 66 B 66 C 251 min Single Unit Installation A 79 B 33 C 251 min Double Unit Side by Side Installation A 79 B 66 C 251 min least 571 4 with door in 90 open position a lt 29 16 to handle height not Pees aa So extension included with Louvered Trim Kit amp Riser Water inlet location left bottom rear and ice maker connection hie location left top rear 32 Il 21 39 hinge height 69 1 4 min 70 1 4 max Power cord location right
8. uxicon com for detailed instructions Optional Accessories e Single Louvered Trim Kit PN SFRRSRKIT e Double Louvered Trim Kit PN DUORSRKI1 G High standards of quality at Electrolux Home Products Inc mean we are constantly working to improve our products We reserve the right to change specifications or discontinue models without notice Printed in the U S A Ww Louvered Trim Kits Installation W WU N WA WEA IRSA Wi A 4 Eh a Y E32AF75FPS E32AR75FPS AWN AUN CNI AAA Ni NW Wed Y AAAY NG AAA A WA AAA Ni ANA WO AN Louvered Trim Kits ae N Single All Freezer Kit SFRRSRKIT lt 21a Single All Refrigerator Kit GRRRSRKIT C hinge height Single Kits include Louvered top grille and vented louvered toe kick 4 riser with leveling system and side top trim pieces Double All Freezer All Refrigerator Kit DUORSRKIT Double Kit includes Louvered top grille and vented louvered toe kick two 4 risers with leveling systems and side top trim pieces ca Single Louvered Trim kit installation shown Louvered ZZ Trim Kit y i E 4 riser with leveling system All Freezer 69 1 4 E32AF75FPS min 70 1 4 All Refrigerator max E32AR75FPS B a Cutout Dimensions ba Height includes Single Unit Installation Double Unit Side by Side Installation cabinet plus 4 riser I 1 TT x 1 1 i rna ce Maker 21 u A 79 B
Download Pdf Manuals
Related Search
Related Contents
Manuel d`utilisateur Onisep. Webclasseur orientation, équipe éducative (mode d`emploi Sony Ericsson DAV-DZ280 User's Manual Kaspersky Lab Small Office Security Physio Relax Manual Príručka k zariadeniu „Handycam“ NEX No.CGMT/MH/S & M/ERP Corr/ 46 03/05/2014 裏面・PDFダウンロード(263KB) Operating Instructions - VEGAPULS 65 - 4 … 20 mA/HART - two-wire vote mode d`emploi - SE-Unsa Copyright © All rights reserved.