Home
Dynasty Spas MC-MP-CE User's Manual
Contents
1. 20 minutes unless manually deactivated first dd The Blower indicator lights up 2 when blower is on at high speed It flashes when blower is on at low speed Automatic water heater start When water temperature is 0 5 C 1 F lower than the Set Point the heater will automatically turn on until water temperature reaches Set Point plus 0 5 C 1 F K The Heater indicator lights up when the heater is on It flashes when there is a request for more heat but the heater has not yet started Note The heater will not start if two pumps or more are rumning at high speed Setting water temperature Use Up or Down arrow key to regulate water temperature The temperature setting will be displayed for 5 seconds to confirm your new selection The Set Point symbol indicates the desired temperature NOT the current water temperature Water temperature can be adjusted by 0 5 C or F increments from 5 to 40 C 59 to 104 F Turning the light on Two intensity spa light Press Light key to turn light on at high intensity Press a second time to turn light to low inten sity A third time turns light off One intensity spa light Press Light key to turn light on Press a second time to turn light off In both cases a built in timer turns light off after 2 hours unless manually deactivated first dy The Light indicator is displayed when 7 light is on at high intensity It flashes when light is on at
2. low intensity Fiber Box Option If your spa has an optional fiber box press Light key to turn fiber box motor amp light on Press a second time to turn fiber box motor off and leave light on A third time turns both motor and light off A built in timer turns fiber box off after 2 hours unless it has been manually deactivated The Light indicator is displayed when fiber box light is on It flashes when fiber box motor and light are on at the same time LED Light Option If spa has an optional LED light Press Light key to tum LED lights on Starting Pump 3 Press Pump 3 Off to turn Pump 3 on Press a second time to turn Pump 3 off A built in timer automatically turns pump off after 20 minutes unless manually deactivated first Troubleshooting To advance to the next color display setting press Light key twice The LEDs will go off with the first press then back on in the next setting with the second press If the LEDs remain off for more than 5 sec the color display sequence will reset and start back at the beginning the next time the Light key is pressed Color display sequences are LEDs light up and slowly cycle through all six colors The slow cycle restarts at the beginning and repeats 2 LEDs light up and remain on in Aqua 3 LEDs light up and remain on in Purple 4e LEDs light up and remain on in Blue 5 LEDs light up and remain on in Gold 6 LEDs light up and remain on in Green 7 L
3. Add water if needed Shut power off and power your spa up again to reset the system supplier if problem persists The display is flashing A power failure has occurred Press any key to reset the system Quick Reference Card Call your dealer or service supplier if problem persists Excalibur Series CDYNASTYSPAS K 4 keypad is mandatory when some options are selected The system automatically performs 2 filter cycles per day at 12 hour intervals During a filter cycle Pumps 2 amp 3 and blower run for one minute Pump then runs at low speed for the remaining of the cycle and Filter Cycle icon lights up If system is equipped with a circulation pump all pumps and blower run for one minute Circulation pump then runs for the remaining of the cycle and Filter Cycle icon lights up Setting filter cycles Press Filter key FDIO 2 The display will show FDxx with xx representing the duration in hours 3 Use Up and Down arrows to change setting 4 Press Filter key again FS06 5 The display will show FSxx with x representing the delay before cycle starts 6 Use Up and Down arrows to change setting 7 Press Filter key to store settings 40 minute filter cycle time out If you turn a pump blower or light on during a filter cycle the cycle will be interrupted and will only resume 40 minutes after the system has turned the last active output off Purge cycles The system can per
4. DYNASTYSPAS e MC MP CE Spa Pack o Excalibur Pump 3 Series Prog CDYNASTYSPAS QQG Pump 1 Pump 2 Blower OOO Econo Filter Light Down The Quick Reference Card provides a quick overview of your spa s main functions and the operations accessible with your digital control pad Note that some functions require the use of the K 4 keypad 10 keys Starting Pump I Press Pump I to turn Pump on at low speed Press a second time to turn Pump to high speed A third time turns Pump off A built in timer automatically turns pump off after 20 min utes unless it has been manually deactivated The Pump I indicator lights up when Pump is on at high speed It flashes when Pump is on at low speed Starting Pump 2 Dual speed pump system Press Pump 2 to turn Pump 2 on at low speed Press a second time to turn pump to high speed A third time turns pump off Single speed pump system Press Pump 2 to turn Pump 2 on Press a second time to turn Pump 2 off In both cases a built in timer turns Pump 2 off after 20 minutes unless it has been manually deactivated The Pump 2 indicator lights up when A Pump 2 is on With a dual speed pump it will flash when Pump 2 is on at low speed Starting the blower Press Blower to turn blower on at high speed Press a second time to turn blower to low speed A third time turns blower off A built in timer automatically turns blower off after
5. EDs light up and remain on in Red 8 LEDs light up for 2 sec flash off then flash on in the next color until all six colors have been displayed The flashing cycle then repeats itself LEDs flash on off quickly for a strobe light effect A built in timer turns lights off after 2 hours unless manually deactivated first 9 soe The Light icon is displayed 21 when LED light is on Standby mode Press and hold Filter key for 5 seconds to turn the system down i e to set it to Standby mode for 60 minutes The display toggles between SBY message and the time re maining All keys are then disabled unless you press Filter key to reactivate the system before the expiration of the 60 minute delay Y Pumps have started up for one minute on several occasions and Filter Cycle icon is flashing displayed Water temperature is Water temperature in 3 flashing dots are displayed A problem has been detected the spa has reached 44 C Not a bug but a feature 1 12 F Do not enter the water Check and open water Our Smart Winter Mode Do not enter the water valves Clean filters if nec protects your system from the cold by automatically turning pumps on for one minute several times a day to prevent water from freezing in pipes Allow water to cool down The system will reset au tomatically when water reaches 43 C 109 F Call your dealer or service essary Check water level
6. e is especially helpful when young children have access to the keypad There are two modes you can choose from Full lock or Partial lock Full lock means that all keypad functions are locked Partial lock means that the basic functions of the spa will remain accessible pumps blower and light but it will be impossible to change the temperature Set Point to override the Economy mode or to enter the Programming mode When control pad is locked the Lock icon will be displayed Locking your digital control pad Press and hold Econo key for 5 seconds LocP 2 The display will show LoeP with P representing Partial lock LocF 3 Release key and keypad will be in Partial lock mode Keep key pressed down for 5 more seconds if you want to be in Full lock mode The LocF message will then be displayed When control pad is locked all automatic functions of the system run as usual If a key is pressed down a LocP or LocF message will be displayed for second To unlock the keypad simply press and hold Econo key again for 5 seconds Economy mode To save energy the Economy mode Set Point is C 20 F below the Normal mode Set Point The Economy Mode icon lights up when Economy mode is on Setting Economy mode Press Econo key EDI2 2 The display will show EDxx with xx representing the Economy mode duration 3 Use Up or Down key to change setting 4 Press Econo key again ES20 5 The display will sh
7. form a number of purge cycles per day During a purge cycle pumps and blower run for two minutes and Filter Cycle icon lights up Setting purge cycles Press Filter key P 24 2 The display will show P xx with xx representing the currently set number of daily purge cycles 3 Use Up and Down arrows to change setting 4 Press Filter key to store settings Boost filtration mode This function allows you to speed up filtration after intensive use of your spa or to mix chemicals Simply keep Pump I key pressed down for 5 seconds Pump will run at high speed for 45 minutes and BOO message will be displayed Ozonator is also activated CLE message Every two weeks the CLE message might be displayed indicating to clean the filter depending on your spa configuration Press any key to reset the message Real time clock Use Clock key to set real time clock The display toggles every 5 seconds alternately showing the hourly time and the current water temperature Water level sensor lf the system is equipped with an optional water level sensor and the sensor detects an insufficient level of water in the tub the system will prevent pumps from starting and will display the H20 message Pumps will be allowed to turn back on when water level returns above sensor j SPA DYNASTYSPAS Digital control pad lockout This function allows you to prevent unauthorized parameter setting of the unit This featur
8. ow ESxx with xx representing the delay before mode starts 6 Use Up and Down arrows to change setting 7 Press Econo key a third time to store settings 40 minute Economy mode time out If you tum a pump blower or light on while Economy mode is on the Economy mode will be interrupted and will only resume 40 minutes after the system has turned the last active output off The Econ message or Economy Mode icon will flash depending on your system configuration Inverted display Press and hold Light key for 5 seconds to invert the display Ifa power up occurs the display always returns to default mode Summary of control panel parameters FDxx Filter cycle duration FSxx Filter cycle start delay LocX Control pad lockout EDxx Economy mode duration ESxx Economy mode delay Pxx Purge cycles 9919 100614
Download Pdf Manuals
Related Search
Related Contents
1.- OBJETIVO Definir la información a recabar, tanto documental SERVICE MANUAL Detailed Specification Poulan 425182 Lawn Mower User Manual Print BDL190S - pdf.lowes.com 2 - KYOCERA Document Solutions prévention, médecine générale et milieux défavorisés HealthCo Training and Implementation Guide Copyright © All rights reserved.