Home
Dialogic Board D/41JCT-LS-EW User's Manual
Contents
1. Reasonable effort is made to ensure the accuracy of the information contained in the document However Dialogic does not warrant the accuracy of this information and cannot accept responsibility for errors inaccuracies or omissions that may be contained in this document INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH DIALOGIC PRODUCTS NO LICENSE EXPRESS OR IMPLIED BY ESTOPPEL OR OTHERWISE TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT EXCEPT AS PROVIDED IN A SIGNED AGREEMENT BETWEEN YOU AND DIALOGIC DIALOGIC ASSUMES NO LIABILITY WHATSOEVER AND DIALOGIC DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY RELATING TO SALE AND OR USE OF DIALOGIC PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE MERCHANTABILITY OR INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT OF A THIRD ARTY Dialogic products are not intended for use in medical life saving life sustaining critical control or safety systems or in nuclear facility applications It is possible that the use or implementation of any one of the concepts applications or ideas described in this document in marketing collateral produced by or on web pages maintained by Dialogic may infringe one or more patents or other intellectual property rights owned by third parties Dialogic does not provide any intellectual property licenses with the sale of Dialogic products other than a license to use such product in accordance with in
2. do not require media sharing or switching across the CT Bus you may use the D 41J CT LS EW or VFX 41 CT LS EWby itself with no CT Bus cable If you are not using a CT Bus connection you do not need to set the CT Bus jumpers and you can proceed to Section 4 Choosing a Slot Note If you are operating the board without a CT Bus connection you must configure the board to H 100 bus mode Otherwise all attempts to download to the board will fail because the CT Bus clock is absent The following instructions apply only to the boards at each end of the CT Bus cable Boards that are in the middle of the CT Bus cable should not be terminated Note If these boards are operating in SCbus mode CT Bus H 100 termination is not required JP1 jumper is reserved and unused Do not install a jumper link across the pins of J P1 JP2 is a 2 pin jumper that is used to terminate the CT Bus ensuring that proper electrical characteristics exist on the CT Bus By factory default this jumper is not terminated on the board To use the CT Bus Install a jumper link on the JP2 jumper of a board to terminate the CT Bus at that board Only terminate the first and last boards the boards located at each end on the CT Bus cable Do not install a jumper link across the pins of JP2 on boards located between the end boards on the CT Bus cable the jumper link must be disconnected on the J P2 jumper to disable termination The J P2 jumpe
3. the D 41J CT LS EW and VFX 41J CT LS EW are supported in the release and for information on any new features or issues that may relate to it The Regulatory Notices document that is packed with each D 41J CT LS EW and VFX 41J CT LS EW Part number 64 0177 02 Physical Layout CT Bus Connector Slot Retainer Bracket JP2 top row pins 1 and 2 JP1 bottom row pins 1 and 2 PCI Express Connector Rear Bracket board contains safety warnings and national 3 Lay the board on the static dissipative work requirements for proper operation of surface telecommunications equipment Note Place boards in static shielding bags when E carrying boards from station to station 2 Before You Begin Protecting the Board from Damage anti static packaging until you are ready to install EARS it Observe proper anti static precautions at all CAUTI ON All computer boards are sensitive to times electrostatic discharge ESD Handle all static sensitive boards and components at a static safe S work area and observe anti static precautions at 3 Configuring the Board all times The D 41J CT LS EW and VFX 41J CT LS EW boards use Plug and Play technology to simplify installation No user configuration is required for IRQ or memory address The D 41J CT LS EW and VFX 41J CT LS EW boards have the following manually configurable options Board ID m Initial hook state CT Bus termination If you are n
4. times while handling and installing the board To install a D 41 CT LS EW or VFX 41 CT LS EW board perform the following steps 1 Turn off all power to the system and disconnect the system s power cords 2 Remove the computer s cover 3 Choose an empty PCI Express expansion slot and remove the slot s retaining screw and access cover plate Note If you are not installing the board in a full length form factor PCI Express slot remove the slot retainer bracket from the end of the board before installation 4 Insert the board s edge connector into the bus slot and apply firm pressure to the top edge of the board until the board is fully seated in the edge connector Remove cor PCI Express Pate Zs Board Computer Chassis Reinstall the retaining screw Repeat steps 1 through 5 for any additional boards you are installing If applicable connect the telephony boards together with a CT Bus cable of the appropriate size not included If possible use a cable assembly that matches the number of boards in your system If the cable has more than one unused connector install the cable so that all the unused connectors are at one end of the cable Replace the computer s cover Reconnect the computer s power cord Colored Your CT Bus cable may have a different number of connectors drops 6 Connecting to External Equipment Each RJ 11 jack on the rear bracket of the D
5. 41J CT LS EW and VFX 41 J CT LS EW boards supports a single channel Use RJ 11 connectors and telephone cable to connect each channel to an analog PBX or standard telephone outlet Note Since these boards emulate a standard telephone a standard telephone will not function when directly connected to the board Rear 2 bracket on board Channel 1 a lt 2 To analog Channel 2 ia one PBX or standard Channel 3 eB lt lt FS telephone outle Channel 4 a m6 J1 J4 on the D 41JCT LS pin Signal and VFX 41JCT LS Board RJ 11 Connector Unused Station Earth Recall 123456 Station Ring Mf Note Connect the Earth Recall signal to pin 2 Do not connect Tip or Ring lines to pin 2 or improper operation of the D 41J CT LS EW or VFX 41 CT LS EW will result 7 After Installing the Board The D 41J CT LS EW and VFX 41J CT LS EW boards require the use of an Dialogic System Software version that specifically supports it If this is the first Dialogic telecom board you have installed in your system you will need to install an appropriate version of the Dialogic System Software and configure the software for the specific board s you are using Refer to the installation and configuration documentation that accompanies the release for instructions Station Tip Unused oj a a wf rm Unused 1 Required Dialogic System Softw
6. Dialogic Dialogic D 41 CT LS EW and VFX 41 CT LS EW Installation Guide Copyright 2006 2007 Dialogic Corporation All rights reserved 1 Product Description The Dialogic D 41J CT LS EW and VFX 41J CT LS EW boards are combined media analog boards with H 100 connectivity and four ports of voice fax and speech in a full length PCI Express form factor The D 41 CT LS EW board supports basic fax while the VFX 41J CT LS EW board supports enhanced fax The D 41J CT LS EW and VFX 41J CT LS EW boards include the following components J 1 J 4 jacks Four RJ 11 jacks to connect to PBX or telephone network Central Office lines SW30 Rotary switch used when setting board ID SW4 Slide switch used to set hook state at startup CT Bus connector H 100 telephony bus connector J P2 jumper CT Bus termination jumper J P1 jumper Not used PCI Express connector Host bus connector Compatible with x1 or larger PCI Express Link connectors Additional Information Additional information about the D 41J CT LS EW and VFX 41J CT LS EW boards is available from a number of sources The product data sheet available at http www dialogic com products list asp provides a functional description as well as information about applications and configurations features and technical specifications Refer to the Release Guide and the online Release Update for your Dialogic System Software release to verify that
7. ademarks of their respective owners
8. are System Release 6 0 PCI for Windows Ser vice Update 131 or higher System Release 6 1 for Linux Service Update 232 or higher If you are installing the board in a system that already has the Dialogic System Software installed you should verify that your installed software version supports the board If not you will need to obtain and install a Service Update that does support the D 41 CT LS EW and VFX 41J CT LS EW boards before configuring the system for the newly installed board s Please refer to the Release Update document for your release version on the Dialogic Telecom Support Resources web page for up to date information about support for PCI Express boards and any known issues relating to their use 8 Removing the Board Removal of the D 41J CT LS EW and VFX 41 J CT LS EW board is essentially the reverse of the installation procedure Observe anti static precautions Disconnect the telephony cables Remove the computer s power cord Remove the computer s cover Disconnect the CT Bus cable if applicable Remove and set aside the board s retaining screw 7 Remove the board and place it in static protective packaging Oy UT WE 9 Warranty and Return I nformation For specific warranty information for this board refer to the Warranty section of the Products page located at this URL http www dialogic com warranties Contacting Technical Support Dialogic provides technical suppor
9. gned to the boards in the Dialogic Configuration Manager DCM after you start the system and invoke that tool Linux Systems In a Linux system you must explicitly specify the board ID numbers by setting SW30 on each board to a different position 0 9 or A F Refer to the Configuration Guide for Springware architecture products in your Dialogic System Software documentation for further information about the board ID numbers Setting the Initial Hook State The position of slide switch SW4 determines how the board responds to an incoming call when the chassis power is on but the board is not initialized Set the SW4 slide switch as follows m SW4 off default Callers hear ringing on hook Ringing On Hook _ ee J m SW4 on Callers hear a busy signal off hook ON Busy Off Hook Sw4 Note If the chassis power is off callers hear ringing on hook regardless of the setting of SW4 Setting the CT Bus Termination The Computer Telephony bus CT Bus provides communication and flexible resource sharing among the boards connected to the bus The D 41 CT LS EW and VFX 41J CT LS EW boards have a CT Bus connector that complies with the ECTF H 100 specification and as such can be connected to the CT Bus with a CT Bus cable To connect the boards to the CT Bus set the CT Bus jumpers according to instructions in this section If you
10. ot familiar with ESD safety precautions visit http dialogic com support hwinstall to learn more Unpacking the Board Unpack the board according to the following steps 1 Prepare a static safeguarded work area 2 Carefully remove the board from the shipping carton and anti static packaging Handle the board by the edges and avoid touching the board s components CAUTI ON Do not remove the board from the Setting the Board I D When the system is started each Dialogic telecom board is assigned a board instance ID number that programs can use to identify individual boards in a multi board system The setting of SW30 controls the generation of the instance numbers Windows Systems In a Windows system leaving SW30 set to the 0 position the factory default setting on all Dialogic telecom boards causes the system software to assign instance numbers geographically based on the bus and slot numbers Note that when using this method there is no way to know what the instance numbers will be until the system is started and configured and the instance number for any given board is likely to change when there is any change in the number or arrangement of boards in the system As an alternative you may set SW30 on each board to a different position 0 9 or A F to explicitly assign specific ID numbers to the boards Note that each board must be set to a different ID number In either case you can read the ID numbers assi
11. r terminates the following H 100 signals CT_FRAME_ A amp B and CT_C8 A amp B 4 Choosing a Slot The D 41 CT LS EW and VFX 41J CT LS EW boards implement a PCI Express x1 lane configuration allowing them to be used in any full length PCI Express slot that fully meets PCI Express Card Electromechanical Specification Revision 1 0a or higher If the D 41J CT LS EW or VFX 41J CT LS EW is the only Dialogic telecom board in the system you may choose any slot for the installation If the D 41J CT LS EW or VFX 41J CT LS EW will be connected to other telephony boards via a CT Bus cable you should install the boards to minimize unused connectors on the CT Bus cable Install boards in adjacent slots whenever possible m If the D 41 CT LS EW or VFX 41J CT LS EW board will be connected to one or more PCI boards use the PCI Express slot s closest to the PCI slots 5 Installing the Board WARNING Unplug the equipment before performing the procedures described here Failure to disconnect the power before you open the chassis can result in personal injury Ensure that the system is disconnected from its power source and from all telecommunications links networks or modem lines whenever the chassis cover is removed Do not operate the system with the cover removed CAUTION To avoid possible damage to the board remove power from the computer before beginning installation Observe proper anti static precautions at all
12. t for its products through a network of value added distributors who are trained to answer technical questions on installing and configuring Dialogic products If you are unsure how to contact your support channel please call Dialogic in the United States at 973 967 6600 9am 5pm EST and we will assist in obtaining the appropriate support channel Outside the United States please refer to http www dialogic com support contact to obtain local contact information Dialogic also provides direct support via Dialogic Pro Services agreements For more details of direct support from Dialogic please refer to http www dialogic com support DialogicPro Returning a Product To return a board for warranty repair or any other returns please refer to the following http www dialogic com support hwfaults 10 Sales Assistance If you have a sales question please contact your local Sales Representative or the Regional Sales Office for your area Address telephone and fax numbers are available at the Dialogic website located at http www dialogic com contact htm To purchase Dialogic products please refer to the following website to locate the appropriate supplier http www dialogic com purchase htm All contents of this document are furnished for informational use only and are subject to change without notice and do not represent a commitment on the part of Dialogic Corporation or its subsidiaries Dialogic
13. tellectual property owned or validly licensed by Dialogic and no such licenses are provided except pursuant to a signed agreement with Dialogic More detailed information about such intellectual property is available from Dialogic s legal department at 9800 Cavendish Blvd 5th Floor Montreal Quebec Canada H4M 2V9 Dialogic encourages all users of its products to procure all necessary intellectual property licenses required to implement any concepts or applications and does not condone or encourage any intellectual property infringement and disclaims any responsibility related thereto These intellectual property licenses may differ from country to country and it is the responsibility of those who develop the concepts or applications to be aware of and comply with different national license requirements Dialogic Diva Eicon Eicon Networks Eiconcard Dialogic Pro and S Pcontrol among others are either registered trademarks or trademarks of Dialogic Dialogic s trademarks may be used publicly only with ermission from Dialogic Such permission may only be granted by ialogic s legal department at 9800 Cavendish Blvd 5th Floor Montreal Quebec Canada H4M 2V9 Any authorized use of Dialogic s trademarks will be subject to full respect of the trademark guidelines published by Dialogic from time to time and any use of Dialogic s trademarks requires proper acknowledgement The names of actual companies and products mentioned herein are the tr
Download Pdf Manuals
Related Search
Related Contents
3 個別広聴(PDF形式:88KB) TDSHーBA 東芝蛍光灯ブラケット取扱説明書 保管用 中国(上海)、インドネシア(ジャカルタ)における日本 式 EMIS-VEKTA 1200 Manual + Passport v1.0.5 Bedienungsanleitung PDF-Dokument Sony Video Game Console Playstation 2 User's Manual GeoVision GV-Data Capture Troubleshooting Targus Notepac, 10-Pk Sabrina brings color and function to the workplace Copyright © All rights reserved.