1. The default domain ID is 1 If the SAN I O Module is not powered on until after it is connected to the fabric and the default domain ID is already in use the domain ID for the new SAN I O Module is automatically reset to a unique value If the SAN I O Module is connected to the fabric after it has been powered on and the default domain ID is already in use the fabric segments To find the domain IDs that are currently in use run the fabricShow command on another SAN 1 0 Module in the fabric Identify an unused domain ID a Disable the SAN I O Module being configured using the switchDisable command b Enter the configure command at the root prompt The command prompts display sequentially Enter a new value at the Domain prompt or press Enter to accept the default value The SAN I O Module now has a unique domain ID and can join the fabric Following is an example of command output Fabric parameters yes y no n no y Data field size 256 2112 2112 Sequence Level Switching 0 1 0 Disable Device Probing 0 1 0 Suppress Class F Traffic 0 1 0 Switch PID Format 1 2 1 Configure Domain 1 239 1 155 R_A_TOV 4000 120000 10000 E_D_TOV 1000 5000 2000 WAN_TOV 0 30000 0 AX HOPS 7 19 7 Per frame Route Priority 0 1 0 Long Distance Fabric 0 1 0 BB credit 1 27 16 Insistent Domain ID Mode yes y no n no Virtual Channel parameters yes y no n no
2. NOTE Use only brocade branded SFPs on the external optical ports of this module 5 Connect the cables to the transceivers The transceivers are keyed to ensure correct orientation If a transceiver does not install easily ensure that it is correctly oriented and that the end caps have been removed The cables used in trunking groups must meet specific requirements For a list of these requirements see the Fabric OS Administrator s Guide ATTENTION Acable should not be bent to a radius less than 5 08 cm 2 inches under full tensile load and 3 048 cm 1 2 inches with no tensile load Tie wraps are not recommended for optical cables because they are easily overtightened a Orient a cable connector so that the key the ridge on one side of connector aligns with the slot in the transceiver b Insert the cable into the transceiver until the latching mechanism clicks For instructions specific to cable type refer to the cable manufacturer s documentation c Repeat for the remaining transceivers as required 6 Check the LEDs to verify that all components are functional For information about LED patterns see the Operating the SAN I O Module chapter in the Brocade M5424 SAN Blade Server I O Module Hardware Reference Manual 7 Verify the correct operation of the SAN I O Module by typing the switchShow command from the workstation This command provides information about SAN I O Module and port status 8 Verify the correct o
3. The product described by this document may contain open source software covered by the GNU General Public License or other open source license agreements To find out which open source software is included in Brocade products view the licensing terms applicable to the open source software and obtain a copy of the programming source code please visit http www brocade com support oscd Brocade Communications Systems Incorporated Corporate Headquarters Asia Pacific Headquarters Brocade Communications Systems Inc Brocade Communications Singapore Pte Ltd 1745 Technology Drive 9 Raffles Place San Jose CA 95110 59 02 Republic Plaza 1 Tel 1 408 333 8000 Singapore 048619 Fax 1 408 333 8101 Tel 65 6538 4700 Email info brocade com Fax 65 6538 0302 Email apac info brocade com European and Latin American Headquarters Brocade Communications Switzerland S rl Centre Swissair Tour A 2 me tage 29 Route de l A roport Case Postale 105 CH 1215 Gen ve 15 Switzerland Tel 41 22 799 56 40 Fax 41 22 799 56 41 Email emea info brocade com Document History The following table lists all published versions of the M5424 QuickStart Guide TABLE 1 Document title Publication number Summary of changes Publication date M5424 QuickStart Guide 53 1001081 01 New document September 2008 4 of 16 M5424 QuickStart Guide Publication Number 53 1001081 01 Overview This Quick Start guide is intended as an overview to help ex
4. do not use the Blade Server Enclosure CMC software Ports on Demand is ready to be unlocked in the SAN I O Module firmware A POD license might be supplied with SAN I O Module software or you can purchase the license separately from your SAN I O Module vendor who will provide you with a key to unlock it Once you have installed the license keys you must enable the ports You can do so without disrupting SAN 1 0 Module operation or alternatively you can disable and re enable the SAN I O Module to activate all ports If you remove a POD License ports that were enabled by that license are disabled Activating ports with a POD license You can activate ports with a POD license while the SAN I O Module is connected to existing SANs or before connecting to an existing SAN For SAN I O Modules already connected to existing storage networks 1 Add the POD license using Web Tools or CLI 2 Enable each newly licensed port using Web Tools or CLI NOTE This method is non disruptive to existing servers and storage connecting to SAN I O Module For new SAN I O Module installations perform the following before connecting to an existing SAN ATTENTION Do not use this method if the SAN I O Module is operating in an existing SAN because traffic will be disrupted 1 Disable the SAN I O Module NOTE If Secure Fabric OS Secure FOS is enabled you cannot use Telnet or SSH to disable the module For details about using Web Tools refer to th
5. 4424 On r 255 255 240 0 10 32176 1 B2 Brocade 4424 On r 1032 181 32 255 255 2400 110 32 176 1 Bone HRB S NOTE Refer to the documentation for the CMC GUI application for additional detail Connecting the SAN 1 0 Module to the Ethernet network Once you have successfully set the appropriate IP address of the SAN I O Module you can establish an Ethernet connection through the Chassis Management Controller CMC to a remote management workstation for any additional configuration The management workstation must be on the same Ethernet subnet as the CMC NOTE Ensure that the SAN I O Module is not being modified from any other connection until configuration is complete M5424 QuickStart Guide 9 of 16 Publication Number 53 1001081 01 Connecting the SAN 1 0 Module to the fabric NOTE Refer to Cabling guidelines on page 6 before beginning the following procedure Before beginning the following steps determine whether the SAN I O Module is in Access Gateway or Fabric OS Native mode This affects the configuration process Using the SAN I O Module CLI you can enter the ag modeShow command to determine the current operating mode 1 If the SAN I O Module is in Fabric OS Native mode continue with step 2 and step 3 If the Module is in Access Gateway Mode go on to step 4 2 Log onto the SAN I O Module through a Telnet connection using the admin account 3 Modify the domain ID if required using SAN I O Module CLI commands
6. SAN I O Module serial console port Note that this is only required if not changing the SAN I O Module IP address through the Blade Server Enclosure GUI or CLI management programs e SFP transceivers and compatible fibre cables as required NOTE Use only brocade branded SFPs on the external optical ports of this module e Access to an FTP server for backing up the SAN I O Module configuration e Access to these publications e Blade Server Enclosure Hardware Owner s Manual e Blade Server Enclosure Configuration Guide e Fabric OS Command Reference Manual e SAN TECH NOTE Preparing to Install the Brocade Access Gateway 6 of 16 M5424 QuickStart Guide Publication Number 53 1001081 01 e Access Gateway Administrator s Guide e Web Tools Administrator s Guide Modify the SAN 1 0 Module IP address By default the IP address for the SAN I O Module is configured as 10 77 77 77 with a default Ethernet subnet mask of 255 255 255 0 Reset the IP address using three methods If the IP values are set using either of these methods the IP values are stored on the SAN I O Module e SAN I O Module Command Line Interface CLI e Blade Server Enclosure CMC CLI e Blade Server Enclosure CMC graphical user interface GUI ATTENTION Do not connect the SAN I O Module to the internal network until the IP address is correctly set for your Ethernet network requirements NOTE It is recommended that you set the IP address using the Blade S
7. in Fabric OS Native mode the switchMode parameter should display Native Enabling Access Gateway mode is a disruptive process because the switch is disabled and rebooted Once you enable the SAN I O Module in Access Gateway mode only a limited subset of Fabric OS commands are available and all fabric related service requests are forwarded to the fabric switches See the Access Gateway Administrator s Guide for more information When you enable Access Gateway mode some fabric information is erased such as the zone and security databases To recover the information save the switch configuration before enabling Access Gateway mode Web Tools Complete the following steps to enable Access Gateway mode using Web Tools 1 From the management console open a Web browser 2 Enter the IP address of the SAN I O Module into the Address field of the Web browser See the Web Tools Administrator s Guide for more information on using Web Tools 3 Log into Web Tools using the default administrative account Login admin Password password 4 From the Fabric Tree select the SAN I O Module The selected SAN I O Module appears in the Switch View 5 Click the Switch Admin button in the WebTools Manage taskbox The Switch Administration window opens 12 of 16 M5424 QuickStart Guide Publication Number 53 1001081 01 NOTE You should save the configuration file if you are converting an SAN I O Module to Access Gateway mode To save your current confi
8. 53 1001081 01 September 29 2008 3 M5424 SAN I O Module QuickStart Guide BROCADE Copyright 2008 Brocade Communications Systems Inc All Rights Reserved Brocade Fabric OS File Lifecycle Manager MyView and StorageX are registered trademarks and the Brocade B wing symbol DCX and SAN Health are trademarks of Brocade Communications Systems Inc in the United States and or in other countries All other brands products or service names are or may be trademarks or service marks of and are used to identify products or services of their respective owners Notice This document is for informational purposes only and does not set forth any warranty expressed or implied concerning any equipment equipment feature or service offered or to be offered by Brocade Brocade reserves the right to make changes to this document at any time without notice and assumes no responsibility for its use This informational document describes features that may not be currently available Contact a Brocade sales office for information on feature and product availability Export of technical data contained in this document may require an export license from the United States government The authors and Brocade Communications Systems Inc shall have no liability or responsibility to any person or entity with respect to any loss cost liability or damages arising from the information contained in this book or the computer programs that accompany it
9. F Port login parameters yes y no n no Zoning Operation parameters yes y no n no RSCN Transmission Mode yes y no n no Arbitrated Loop parameters yes y no n no System services yes y no n no Portlog events enable yes y no n ne ssl attributes yes y no n no http attributes yes y no n no 10 of 16 M5424 QuickStart Guide Publication Number 53 1001081 01 snmp attributes yes y no n no rpcd attributes yes y no n no cfgload attributes yes y no n no webtools attributes yes y no n no System yes y no n no WARNING The domain ID will be changed The port level zoning may be affected c Re enable the SAN I O Module by entering the switchEnable command NOTE It could take a short time typically a few seconds but sometimes up to 20 seconds for the newly added SAN 1 0 Module to appear in the fabric display with its newly assigned domain ID 4 Ifyou need to install SFP transceivers install them in the external Fibre Channel ports as required a Remove the dust plugs from the ports to be used b If necessary remove the end caps from the SFP c Orient the transceiver correctly and insert it into a port until it is firmly seated and the latching mechanism clicks For instructions specific to the type of transceiver refer to the transceiver manufacturer s documentation d Repeat substeps a b and c for the remaining ports as required
10. ctly set Using the CMC CLI to set the IP address Use the following steps to connect modify the SAN I O Module IP address through the CMC CLI 1 Establish a Telnet session to the CMC CLI 2 Atthe command prompt type connect switch x where x is the bay where the SAN I O Module is installed For example switch x can be e Switch 3 for SAN I O Module installed in bay B1 e Switch 4 for SAN I O Module installed in bay B2 e Switch 5 for SAN I O Module installed in bay C1 e Switch 6 for SAN I O module installed in bay C2 3 At the login prompt enter the default user name as admin and password as password 8 of 16 M5424 QuickStart Guide Publication Number 53 1001081 01 4 Use the appropriate CLI commands to change the IP address of the selected SAN I O module Refer to your Blade Server Enclosure CLI documentation Using the CMC GUI to set the IP address To change the IP address use the following steps 1 Open the CMC application s Setup tab 2 Enter the new information in the IP Address Subnet Mask and Gateway fields as appropriate and click Apply 3 To enable DHCP select DHCP Enabled and click Apply FIGURE 1 CMC Setup Tab Chassis Management Controller Support Help About Log Out De Power Supplies Here you can configure O Modules Network Settings Temperature Sensors Slot Name Power State DHCP Enabled IP Address Subnet Mask Gateway A1 Ethamet Passthrough 0000 0000 B1 Brocade
11. e Web Tools Administrator s Guide For details about the CLI see the Fabric OS Command Reference Manual 2 Add the POD license using Web Tools or the CLI 3 Enable the SAN I O Module using Web Tools or CLI When the SAN I O Module is enabled the newly added POD ports are also enabled 14 of 16 M5424 QuickStart Guide Publication Number 53 1001081 01 Connecting to the SAN 1 0 Module Using Web Tools Complete the following steps to connect to the SAN I O Module using Web Tools 1 On the management console open a Web browser such as Internet Explorer The Web browser must be connected to the same network as the SAN I O Module 2 Enter the IP address of the SAN I O Module in the address field and press Enter For more information about using Web Tools see the Web Tools Administrator s Guide M5424 QuickStart Guide Publication Number 53 1001081 01 15 of 16 16 of 16 M5424 QuickStart Guide Publication Number 53 1001081 01
12. erver Enclosure CMC GUI application because this enables centralized management of the SAN I O Module Using the SAN 1 0 Module CLI to set the IP address Use the following tasks to change the IP address on the SAN I O Module using the Module s CLI Task 1 Establish a terminal session with the SAN I O Module Use these steps to establish a terminal emulation session between the SAN I O Module and a Blade Server Enclosure management workstation used for managing the I O Module Once this session is established you can log into the Module and use its CLI commands to manage the module 1 Connect a serial cable between the serial console port on the SAN I O Module and a Blade Server Enclosure management workstation that can establish a terminal emulation session with the SAN I O Module For instructions refer to Configuration Guide for your Blade Server Enclosure 2 Disable any serial communication programs that are running on the workstation 3 Using a terminal emulator application such as HyperTerminal on a PC or TERM in a LINUX or UNIX environment establish a terminal session to the SAN I O Module from the management workstation You will use this connection if you want to reset the module s IP address using CLI commands and perform other configuration tasks For Windows 95 98 2000 XP or NT a Click Start and select Programs gt Accessories gt Communications b Select Hyperterminal and enter a name for the connection c F
13. foam ends from the SAN I O Module Be sure that you have taken the necessary precautions for electrostatic sensitivity then break the seal warning Slide the SAN I O Module out of the antistatic sleeve and inspect it carefully for any obvious defects or shipping damage 7 For complete instructions to install the SAN I O Module into the Blade Server Enclosure refer to the section on installing an I O module in the Blade Server Enclosure Hardware Owner s Manual NOTE Be sure to remove the protective covers from the external ports before installing the module into the enclosure M5424 QuickStart Guide 5 of 16 Publication Number 53 1001081 01 Cabling guidelines After modifying the SAN I O Module s IP address and domain name if Module is in Fabric OS Native mode we recommend that you cable all external ports to fabric connections before bringing the SAN I O Module online Refer to Configuring the SAN I O Module on page 6 for steps on modifying the IP address Begin by cabling ports 17 18 19 20 21 22 23 and O Ports 17 and 18 are licensed at the factory as part of Dynamic Ports On Demand DPOD By cabling these ports first you will not need to move licenses to other ports you may have cabled Configuring the SAN 1 0 Module Use procedures in this section to configure the SAN I O Module to operate on a network and fabric Also provided are steps to change the Module s operating mode Fabric OS Native and Access Gateway
14. guration click the Show Advanced Mode button in the top right hand corner of the Switch Administration window Select the Configure tab then select the Upload Download tab Enter the relevant information to upload the configuration file 6 From the Switch Status section click Disable 7 From the Access Gateway Mode section click Enable 8 Click Apply 9 When prompted click Yes to restart the SAN I O Module in Access Gateway mode The current Web Tools session closes relaunch Web Tools after the SAN I O Module reboots Command Line Interface Complete the following steps to enable Access Gateway mode using the CLI 1 Login using the default administrative account Login admin Password password 2 Enter the following command to disable Fabric OS Native mode switchDisable 3 Enter the following command to save the current configuration on the SAN I O Module This command is optional and is only required if you are converting an existing SAN I O Module to Access Gateway mode configUpload Save 4 Enter the following command to enable Access Gateway mode ag modeEnable The SAN I O Module automatically reboots and comes back online in Access Gateway mode using a factory default F_Port to N_Port mapping You can enter the ag modeShow command to ensure that the module is in Access Gateway mode See the Access Gateway Administrator s Guide for more detailed configuration information You can also enter the ag mapshow com
15. mand to display the F_Port to N_Port mapping Enter ag help command to display a list of all Access Gateway actions Changing from Access Gateway to Fabric OS Native Mode If your SAN I O Module is currently configured in Access Gateway mode you can enable the module for Fabric OS Native mode by disabling Access Gateway mode When you do this the module automatically reboots in Fabric OS Native mode Determine if the SAN I O Module is running in Access Gateway mode by entering the switchShow CLI command to display the current switch configuration If running in Fabric OS Native mode the switchMode parameter should display Access Gateway Mode M5424 QuickStart Guide 13 of 16 Publication Number 53 1001081 01 For complete instructions on disabling Access Gateway Mode using the CLI and joining the switch to the fabric refer to the Disabling Access Gateway Mode section in the Access Gateway Administrator s Guide NOTE Disabling Access Gateway mode is disruptive because the switch is disabled and rebooted Always back up the current configuration before enabling or disabling Access Gateway mode Enabling Access Gateway mode clears the security and zone databases Disabling Access Gateway mode clears the F_Port to N_Port mapping Activating Ports on Demand POD Ports on Demand POD licensing allows you to enable up to 24 ports from the initial 12 ports Add optional POD licenses using either Brocade Web Tools or a Telnet connection
16. modes activating Ports on Demand POD and connecting to the SAN I O Module using Web Tools NOTE Although the SAN I O Module is configured at the factory for Fabric OS Native mode you can enable Access Gateway mode Refer to procedures under Changing from Fabric OS Native to Access Gateway mode on page 12 This publication provides procedures that use SAN I O Module Command Line Interface CLI and the Web Tools application For details refer to the Brocade Web Tools Administrator s Guide Access Gateway Administrator s Guide and Fabric OS Command Reference Manual If the same operation can be performed using the Blade Server chassis management application use that application instead Items required The following items are required for configuring and connecting the SAN I O Module for use in a network and fabric e The SAN I O Module installed in a Blade Server Enclosure For instructions refer to the steps on installing an I O module in the Hardware Owner s Manual for the Blade Server Enclosure e If required management workstation computer that has a terminal emulator Such as HyperTerminal or a keyboard video and mouse KVM device Note that this is only required if not changing the SAN I O Module IP address through the Blade Server Enclosure GUI or CLI management programs e An unused IP address and corresponding subnet mask and gateway address unless DHCP is used e If required a serial cable to connect to the
17. peration of the SAN I O Module in the fabric by typing the fabricShow CLI command from the workstation M5424 QuickStart Guide 11 of 16 Publication Number 53 1001081 01 9 Back up the SAN I O Module configuration to an FTP server by typing the configUpload command and following the prompts This command uploads the SAN I O Module configuration to the server making it available for downloading to a replacement SAN I O Module if necessary Brocade recommends backing up the configuration on a regular basis to ensure that a complete configuration is available for downloading to a replacement SAN I O Module For specific instructions about how to back up the configuration see the Fabric OS Administrator s Guide The switchShow fabricShow and configUpload commands are described in detail in the Fabric OS Command Reference Manual Changing from Fabric OS Native to Access Gateway mode If your SAN I O Module is currently configured in Fabric OS Native mode you can enable Access Gateway mode using the following instructions You can log into the SAN I O Module and enable Access Gateway mode using either Web Tools or the SAN I O Module command line interface CLI Notes Although the module ships from the factory in Fabric OS Native mode you can enable it in Access Gateway mode Determine if the SAN I O Module is running in Fabric OS Native mode by entering the switchShow CLI command to display the current switch configuration If running
18. perienced installers unpack install and configure an 8 Gbps M5424 SAN I O Module quickly For detailed installation and configuration instructions see the Brocade M5424 SAN I O Module Hardware Reference Manual NOTE Throughout this document the M5424 SAN I O Module is referred to as the SAN I O Module Unpacking and installing the SAN 1 0 Module If the SAN I O Module is installed in the Blade Server Enclosure that is shipped to you skip this section This section applies when installing a new module in an empty bay or replacing an existing SAN I O Module NOTE The SAN I O Module is designed to work only in I O bays B1 B2 and C1 C2 of the Dell M1000e Blade Server Enclosure Make sure to comply with installation requirements in the Blade Server Enclosure Hardware Owner s Manual Perform the following steps to remove the SAN I O Module from its shipping package 1 Open the shipping box and inspect the contents making sure that nothing is missing or damaged Do not insert a damaged SAN I O Module into the Blade Blade Server Enclosure If the SAN I O Module appears to be damaged contact your sales representative before proceeding 2 Remove the cardboard accessory tray from on top of the SAN I O Module This tray contains the documentation regulatory statements product information guide and Documentation CD 3 Remove the SAN I O Module from the box The protective foam ends will slide out with the SAN I O Module 4 Remove the
19. rom the Hyperterminal window click the Connect drop down menu and select an available COM port d Click OK M5424 QuickStart Guide 7 of 16 Publication Number 53 1001081 01 e From the COM Port Properties window select the following configuration values e Bits per second 9600 Databits 8 e Parity None Stop bits 1 e Flow Control None For LINUX or UNIX a Enter the following at the command prompt tip dev ttyb 9600 b When the terminal application stops reporting information press Enter to display the login prompt c Login to the default administrative account using the following identification Login admin Password password d When prompted either change the administrative password or press Ctrl C to bypass Task 2 Changing the IP address 1 3 Verify that the SAN I O Module has completed POST When POST is complete the port status and SAN I O Module power and status LEDs return to a standard healthy state Enter the CLI ipAddrSet command Follow on screen instructions and supply the correct information as shown in the following example switch admin gt ipaddrset Ethernet IP Address 10 77 77 77 10 32 53 47 Ethernet Subnetmask 255 255 255 0 255 255 240 0 Fibre Channel IP Addresss none Fibre Channel Subnetmask none Gateway IP Address 0 0 0 0 10 32 48 1 DHCP Off IP address is being changed Done Enter ipAddrShow at the prompt to verify that the address was corre