Home

Danby DAC9007EE User's Manual

image

Contents

1. 2 Introduction Thank you for choosing a Danby Designer Room Air Conditioner to cool your home This Use and Care Manual provides information necessary for the proper care and maintenance of your new Room Air Conditioner If properly maintained your air conditioner will give you many years of trouble free operation To avoid installation difficulties read these instructions completely before installing operating your unit NOTE This unit is NOT designed for through the wall installation For easy reference you may want to attach a copy of your sales receipt to this page Note the following information provided on the manufacturer s nameplate located on the unit This information will be needed when you contact a Customer Service Representative Model Number Serial Number ___________________________________________________ Date of Purchase _________________________________________________ Dealer s Name and Address ________________________________________ ________________________________________ Refer to the trouble shooting section of this Use and Care Manual if the unit is not operating correctly If these suggestions do not solve the problem contact an authorized service representative or call Danby TOLL FREE 1 800 26 Danby This symbol denotes a caution or warning CAUTION Do not leave a room air conditioner unattended in a space where people or animals who cannot react to a fai
2. Bracket Fig 3 Shutter Frame Shutter Fig 4 Slide down into guide U Shaped Channel Factory Installed Fig 5 L Shaped Mounting Bracket Window Sash Fig 6 Foam Seal Shutter clamps Safety Lock 3 4 19 1mm Screws 3 4 19 1mm Screw Remote Control Features Electronic Display Displays the following information A Remote Control power On Off and Mode Icons B Clock and Auto Timer settings C Current set temperature D Fan speed setting Control Buttons 1 Power switch 2 Mode 3 Fan Speed 4 Energy Saver 5 Auto Timer 6 Used to increase or decrease temperature settings in 1 increments on the Celsius or Fahrenheit scale When adjust the timer or timer settings in 1 minute 7 Cancels current Timer ON OFF settings 8 Lock prevents the remote control settings from inadvertently being changed 9 Clock Depress the button for 3 seconds in order to set the clock Press the increase or decrease arrow to adjust the clock in 1 minute intervals holding down the increase or decrease arrow will adjust the time in 10 minute intervals 10 Used to activate the SLEEP program 11 Toggle the LED backlight on off 12 Restore remote control default settings To operate the hand held remote control will require two AAA Alkaline batteries included Batteries should be replaced when a No signal beep is heard when
3. attempting to program the main unit b The main unit does not respond to a command issued by the remote control Battery replacement 1 Slide the rear cover on the remote in the direction of the arrow Continue pulling gently until the cover separates completely from the unit 2 Insert 2 batteries AAA following the same orientation polarity depicted inside the battery chamber 3 Re install rear cover 4 If the remote control will not be used for extended periods of time vacations etc batteries should be removed The remote operates within a range of 8 meters 26 ft from the receiver located inside the main unit Any obstruction between the receiver and remote may cause signal interference limiting the ability to program the main unit 8 1 2 3 4 5 6 7 8 9 10 11 A B C D Electronic Display 12 Troubleshooting Guide Frequently a problem is minor and a service call may not be necessary use this troubleshooting guide for a possible solution If the unit continues to operate improperly call Danby s Toll Free Number 1 800 263 2629 for assistance or call one of our service depots listed in the enclosed Authorized Service Depot listing provided with this unit Difficulty Possible Cause Suggested Solution Air conditioner will No power to unit Check connection of power cord to not operate power source Check fuse or circ
4. ensation run off 10
5. et is within reach of the installation Use only a single outlet circuit rated at 15 amps All wiring should be in accordance with local and national electrical codes F DO NOT USE REGULAR EXTENSION CORDS WITH THIS UNIT If it is necessary to use an extension cord to connect your air conditioner use an approved air conditioner extension cord only available at most local hardware stores G DO NOT install unit where leakage of combustible gas is suspected Your air conditioner may fail to operate in air containing oils including machine oils sulfide gas near hot springs etc sp Side obstruction 20 50 8cm Min Fig 2 Ground Fence wall or other obstacle Awning 12 30 5cm Min 30 76 2cm Min 20 50 8cm Min 5 CAUTION Because the compressor is located towards the rear of the unit this side will be heavier and more awkward to manipulate Therefore it is recommended to have someone assist you during the installation of this unit Installation 6 1 Assembly of the Upper Channel to Cabinet Factory installed on some models L Shaped Top Channel Install the L shaped channel to the top of the cabinet as shown in Fig 3 using four 4 3 8 9 5mm screws 2 Assembly of the Side Curtains to Cabinet Extend the shutter from the shutter frame and slide it into the shutter guide on the side channel of the air conditioner as shown in Fig 4 Slide
6. led unit are located A failed unit can cause extreme overheating and fire in an enclosed unattended space SAVE THESE INSTRUCTIONS Your unit is designed to evaporate condensation under normal conditions However under extreme humidity conditions excess condensation may cause basepan to overflow to the outside The Unit should be installed where condensation run off cannot drip on pedestrians or neighboring properties Select the Best Location A This room air conditioner is designed to fit easily into a single or double hung window However since window designs vary it may be necessary to make some modifications for safe proper installation B Make sure window and frame are structurally sound and free from dry and rotted wood C For maximum efficiency install the air conditioner on a side of a house or building which favors more shade than sunlight If the unit is in direct sunlight it is advisable to provide an awning over the unit D Provide sufficient clearance around the cabinet to allow for ample air circulation through the unit See Fig 2 The rear of the unit should be outdoors and not in a garage nor inside a building Keep unit as far away as possible from obstacles obstructions and at least 30 76 2cm above the floor or ground Curtains and other objects within a room should be prevented from blocking the air flow E Be certain the proper electrical outl
7. the shutters into the top L Shaped and bottom U Shaped channels The shutters are identified on frame as left amp right 3 Completing the Installation Cut the foam non adhesive sealing strip to fit the area of the window sill that the air conditioner will rest on 3a Completing the Installation cont d Carefully place the air conditioner into the window with the L shaped mounting bracket on top positioned in front of the upper window sash The bottom of the cabinet should be positioned on the recessed portion of the window frame Pull the window down until it rests just behind the front flange of the top L shaped mounting bracket See Fig 5 Expand the shutter frames fully on each side and secure the top of the frames to the window sash using one 3 4 19 1mm screw on each side and one in the L shaped mounting bracket Fig 5 Secure the shutter clamp on each side of the lower shutter and secure to window sill using one 3 4 19 1mm screw on each side Fig 5 Place the second foam sealing strip to fit the opening between the inside and outside windows then attach the safety lock to the outside window frame using one 3 4 19 1mm screw See Fig 6 PLEASE NOTE Window applications come in a variety of different styles Therefore it may be necessary to modify or improvise your particular installation 3 8 9 5mm Screw L Shaped Mounting
8. uit breaker Inefficient or no cooling Dirty air filter Clean or replace air filter Unit size inappropriate Check with dealer to determine proper unit for application capacity for application Blocked air flow Remove obstruction from grill or outdoor louvers Power interruption settings Turn the unit off and wait 5 minutes before changed too quickly or attempting to re start compressor overload tripped Noisy unit Loose parts Tighten loose parts Inadequate support Provide additional support to unit Odors Formation of mold mildew or Clean unit thoroughly algae on wet surfaces Place algaecide tablet in base pan Water dripping outside Hot and humid weather Condensation run off is normal under these conditions Water dripping inside Unit is not properly angled to Unit must be installed on an angle for proper allow water to drain outside condensation run off Check the unit and make any adjustments Ice or frost build up Low outside temperature When outdoor temperature is approximately 65 F or below frost may form when unit is in cooling mode Switch unit to FAN only operation until frost melts Unit air filter is dirty Remove and clean filter NOTES 1 If circuit breaker is tripped repeatedly or fuse is blown more than once contact a qualified technician 2 When unit is installed using proper installation steps unit is properly tipped towards the outdoors to allow for cond

Download Pdf Manuals

image

Related Search

Related Contents

Beckett WC18 Use and Care Manual  RADAR LEVEL TRANSMITTER USER MANUAL  geral - Jornal HoraH  ASUS P9D WS (90SB03E0-M0EAY5)  Avaya IP Softphone Release 6.0 User Reference  配線用遮断器・漏電遮断器 G-TWINシリーズ (経済形32AF~100AF) 個  Hard Candy Cases Bubble Slider iPhone 4  KERABOND T  WinConnect S User Manual  床 面 積 2 , 0 0 0 ∼ 2 0 , 0 0 0  

Copyright © All rights reserved.
Failed to retrieve file