Home

CTEK Power USA CDMA2000 User's Manual

image

Contents

1. l De tos G FeV By l j Obtain ONS server address automatically Install Use the folowing DNS serves addresses ms Description 4 Preferred DNS server eE Transmission Control Protocol Intemet Protocol The default Abernnte DNS sever i wide area network protocol that provides communication i 2 j ogee orso rcon n Show icon in notification area when connected Figure 3 Part Number 91 007 02 4 Administration Configuration and Status About Addressing Devices connecting to CDMA 1XRTT networks are assigned an IP address by the serving network Address assignment may either be static or the unit will be dynamically assigned an IP addresses depending on arrangements that you have made with your wireless network operator Dynamically assigned IP address remain in effect for a period of time assigned by the network operator usually at most a small number of hours Ctek s SkyRouter includes features that manage the temporal nature of dynamically assigned wireless IP addresses Using the Wireless Configuration screen you can configure your SkyRouter to use a Dynamic DNS DDNS service Ctek operates a DDNS test bed that allows our customers to observe the performance and reliability of DDNS with their applications For large scale commercial applications Ctek recommends that users configure their own DDNS managed and maintained with the customers ongoing IT operations Any Series 4100 SkyRout
2. 16 23 Part Number 91 007 02 5 Specifications Controller Axis Etrax 100LX MCM 4 16 Linux 2 4 Interfaces Four Port Ethernet Switch RJ45 Ethernet 10 100baseT Full or Half Duplex auto polarity sensing Relay Input Interface Designed to detect closure or opening of relay contacts Physical 2 Pin Terminal Block Electrical Self powered current limited loop senses state of relay contacts No external power required Maximum cable length between Series 4100 and relay 50 feet Relay Output Interface Physical 2 Pin Terminal Block Electrical Self powered 40ma 12VDC Wireless Interface CDMA2000 1XRTT Physical SMA Antenna removable CDMA Approvals Compliant with IS 95 CDMA 2000 specifications FCC Part 22 24 and 15 Power Requirements Standard 12VDC 10 115VAC gt 12VDC Wall Transformer included Power Consumption 12VDC nominal CDMA Radio Off 180ma CDMA Radio On Data Channel Inactive 230ma CDMA Radio On 1 Ethernet Port Connected 384ma CDMA Radio On 4 Ethernet Ports Connected 445ma Environmental Operating temperature range 20C to 70C Humidity 90 non condensing Physical Dimensions 5 275 L x 5 225 W x 2 08 H Weight 120z Mounting Self standing or wall mount 24 Part Number 91 007 02 6 Certifications FCC Part 15 This equipment has been tested and complies with the limits for a Class A computing device according to U S Code of Federal Regula
3. Figure 11 17 Part Number 91 007 02 4 3 3 Admin Screen Services This service allows the user to control overall local and remote administrative access http 192 168 1 10 admin bin cfg_admin cgi Microsoft Internet Explorer File Edit View Favorites Tools Help Q x AO Pea a B s Address http 192 168 1 10 admin bin cfg_admin cgi E gt Go Links ee Admin Screen Control Port Number For Admin Screen Access 80 Allow Network Access to Admin Screens Yes O No Figure 12 Port Number For Admin Screen Access Causes the WAN side web server to listen on a port other than the default of Port 80 Allow Network Access To Admin Screens If set to Yes administrative users will be able to connect to SkyRouter s Admin interface over the 1XRTT network connection If this selection is set to No only local administration is possible 18 Part Number 91 007 02 4 3 4 Over The Air OTA Programming Almost all CDMA2000 networks employ one form or another of OTA to refresh Preferred Roaming Lists PRL and to make other programmatic changes to the firmware associated with the wireless interface Some networks have streamlined the entire process into a single command that performs the activation and downloads the required data files In other cases a series of command steps are require to do a complete activation The OTA programming function allows you to enter the required short codes to accomplish Over
4. Relay This text will appear on the advertising screen next to the relay activation button Part Number 91 007 02 4 3 Services 4 3 1 Password Administration Used to change passwords and create users Be sure to record this information in a secure location http 192 168 1 10 admin bin cfg_pwd cgi Microsoft Internet Explorer 0 File Edit View Favorites Tools Help ay Back x A search sie Favorites Ama 4 62 22 GF i he 7 a E Address http 192 168 1 10 admin bin cfg_pwd coi v Go Links a Coos _ Enter new username and password New User Name New Password Confirm New Password Figure 9 4 3 2 Routing and Forwarding Services The Routing and Forwarding Services screen provides two separate but related functions First it allows you to forward WAN side IP traffic arriving on a specific IP Port to a specific Port at a LAN side address In addition to this conventional forwarding feature this screen also allows you to make a Named Service publicly available over the WAN interface In Figure 14 below WAN side UDP and TCP traffic arriving on Port 88 is redirected to Port 80 of LAN address 192 168 1 102 The second function performed by this set up screen to allow named services to be made publicly available to WAN side users Referring again to Figure 14 a service named Camera 1 will be advertised or made publicly available Security for this advertised service is left up to the specific service If
5. The Air Programming on the network that you are using Any single command line can be entered on the OTA screen This command line will be sent directly to the CDMA radio and from there to the wireless network The OTA screen will display a single line of response from the network Ctek publishes TechNotes on the activation procedures for different networks Note Before using the OTA screen you must e Goto the Wireless Interface Screen and disable the WAN interface of your SkyRouter e Perform a Restart of your SkyRouter These steps terminate any packet or circuit connection with the network so that OTA operations may take place with no interference Once the OTA programming is completed you will need re enable the WAN interface and restart your SkyRouter to re establish network connections Ctek SkyRouter Microsoft Internet Explorer File Edit View Favorites Tools Help ay N zy Cx Ei Om O MAD Osa fere Gun O E D VA Address http ctek0 1 thingme net admin bin cfg_ota cgi i gg gt E Links Google v PSearchweb go PageRank E Eh 4634blocked E Pao SPC Unlock 000000 Command Response CAUTION You must perform a restart after issuing OTA commands Figure 13 19 Part Number 91 007 02 SPC Unlock Required for OTA on some networks Consult Ctek s Activation TechNotes for specifics Command Enter network specific OTA commands in this field Consult Ctek s Activation TechN
6. Use Ctek Enhanced Wireless DDNS with UDP updates over the 1XRTT Air Interface 4 Standard UDP Use a standard BIND MS2000 or MS2003 DDNS server Device Name Establishes the name by which this particular SkyRouter will be known at the Name Server This entry must be a fully qualified device name and domain and is limited to 40 characters in total It is limited to one level of name space definition meaning that all characters to the right of the first dot will be assumed to be a component of the resolving server An example would be ctek01 thingme net where ctek07 is the name of an individual SkyRouter and thingme net is the name of the resolving server Primary and Secondary Name Server Enter either phone number SMS updates or the IP address of the designated Name Server Name resolution is not performed on this entry meaning that a numeric IP address of the resolving server is required Part Number 91 007 02 Provide Network Name Server Facilities Selecting Yes causes this SkyRouter to provide Name Server services to client SkyRouters configured to use it If this option is selected additional set up in the Name Services screen will be required 4 2 2 Configuring The Ethernet Interace The Ethernet configuration determines how devices connected to the LAN side of SkyRouter will be addressed and what the actual address of this SkyRouter will be on the LAN 6 http 192 168 1 10 admin bin cfg_eth0 cgi Microsoft Inter
7. can be defined on the Advertising screen described in the Services section T Ctek SkyRouter Microsoft Internet Explorer File Edit View Favorites Tools Help a Q x x a Ay J gt Search Sie Favorites Que O A i A i Address http ctek0 1 thingme net admin bin cfg_relayout cgi GO Links Google v PSearchweb go PageRank Ey h5721 blocked E Fa options gn i Ca Relay Output Configuration Pd meast Set Relay Output State Off O On Relay Shut Off Timer Never Allow SMS Control Of Relay O Yes No Allow Web Browser Control Of Relay O Yes No Text For Web Link To Relay Set Relay Output State Used to set the current state of the relay driver circuit The relay driver can be activated and deactivated by changing this setting and pressing update Relay Shut Off Timer The relay driver circuit will revert to its default setting after the number of minutes or seconds specified by this parameter The two second setting is useful for resetting end point equipment 13 Part Number 91 007 02 Allow SMS Control of Relay If Yes is checked the relay driver may be activated by sending an SMS with the command R1 and deactivated by sending an SMS with the command of RO Allow Web Browser Control of Relay If set to yes a button will appear on the Advertising screen to enable and disable the relay driver circuit Text For Web Link To
8. recommended that an address of 192 168 1 10 be used The DHCP server will issue dynamic IP addresses to 10 Part Number 91 007 02 other devices connected to the LAN side IP addresses will be assigned for up to 50 devices Address assignment is sequential in the range of 192 168 1 100 192 168 1 150 Enable Client Some other device on the LAN side of the network is acting as a DHCP server SkyRouter will be assigned a dynamic IP address by the DHCP server DNS Address Source In most cases this parameter should be set to Acquire From Wireless Network In this case when you click on the Update button the Skyrouter will verify that it has been connected to the wireless network and that the wireless network has provided DNS addresses If DNS addresses have been provided they will be displayed in the Primary and Secondary Address boxes If addresses have not been provided you will receive an error indication At that point you should allow the SkyRouter to establish a connection with the wireless network so that it can acquire the DNS addresses You should then go back into the Ethernet Configuration screen and click on submit again At this point the DNS addresses should appear If you application requires a specific DNS setting check the User Defined box and manually fill in the DNS IP Address fields below DNS IP Address Primary and Secondary The address of the Domain Name Server that your network uses This should not be con
9. CTEK Series 4100 SkyRouter CDMA2000 1XRTT Access Point and Router USER MANUAL Series 4100E Part Number 91 007 02 Firmware Release 1 02 QUALITY COMMUNICATIONS FOR INDUSTRY Made in the U S A Part Number 91 007 02 Table of Contents TABLE OF CONTENTS PREFACE 1 INTRODUCTION 1 1 Theory Of Operation 1 2 Features 1 3 What Is In The Box 2 CONNECTORS LIGHTS SWITCHES AND JUMPERS 2 1 Switches 2 2 Connectors 2 3 Lights 3 START UP 3 1 Power 3 2 Connecting The Antenna 3 3 Connecting to the Ethernet Port Administrative Connection 4 ADMINISTRATION CONFIGURATION AND STATUS 4 1 Getting Started 4 2 Interfaces 4 3 Services 4 4 Status 5 SPECIFICATIONS 6 CERTIFICATIONS 15 21 24 25 Part Number 91 007 02 Preface Welcome to the Ctek Series 4100E SkyRouter User s Guide The User s Guide will explain the basic operation of a SkyRouter and take you through the necessary settings to get your wireless application online Additional information and applicable technical notices can be found at www ctekproducts com 1 Introduction SkyRouter provides application and network designers with a bridge between the world of IT infrastructure and the evolving wireless data networks With SkyRouter the wireless transport is fully integrated into the product s routing fabric meaning that you can approach the setup and operation of this product much as with any other IP addressable device Wireless consi
10. So if ON CLOSURE is selected an SMS is sent every time that the contacts close This means that once closure is sensed there can be no other closure event until the contacts are first sensed to be open All other modes where Max Trigger Rate has a time value are level sensitive So it the contacts close an SMS is sent and then the state of the relay input is ignored for a defined period of time For instance if Max Trigger Rate is set to 5 minutes an SMS is sent and then the relay input is sampled again in 5 minutes If the contacts are still closed another SMS is sent If the relay input is not closed SkyRouter reverts to monitoring the relay every second 12 Part Number 91 007 02 SMS Destination Address The MIN mobile phone number or email address to which the SMS message will be sent MIN must be 10 numeric characters with no spaces or punctuation Any email address in the form Anything Any_Domain will be accepted SMS Alert Message The text of the message to be sent when the relay interface activates Limited to 100 characters maximum Only printable ASCII characters in the range of 32 126 decimal 20 7E hex can be included in the message 4 2 4 Configuring The Relay Output Driver Interface This screen configures the connection characteristics of the relay output interface and defines the service associated with this interface Currently the relay output interface can be activated by an SMS message or from a button that
11. al Level RSSI 115dBm Roam Status Not Roaming Current IP Address 166 156 152 151 Call Type Packet Relay Model Call Status Connected Figure 15 ESN An identifier assigned to the CDMA radio for this SkyRouter The value is given in decimal Dec and Hexidecimal Hex System ID SID Numeric Identifiers assigned to local market areas within a wireless network Your wireless network operator may request this information if you are having trouble connecting to the network Telephone Number MIN The circuit side phone number of the CDMA radio in your SkyRouter MIN stands for Mobile Identification Number Network Status Either In Service or Out of Service Indicates the state of the network as seen through your particular SkyRouter Signal Level RSSI A measure of the strength of the wireless signal that your SkyRouter is currently seeing A larger negative number indicates a marginal network connection 21 Part Number 91 007 02 Roam Status Indicates the network s view of the current geographic location of your SkyRouter The possibilities are Not Roaming Home Roaming or Blink Roaming An indication of Roaming may or may not impact your data transmission costs Charges are a function of your rate plan not necessarily linked to the networks notion of roaming Note also that Off Network Roaming is not supported by most 1XRTT packet networks today but may be in the future Current IP Address If the Cu
12. assword is also ctek Be sure to change the user ID and password and record your new selections F Ctek SkyRouter Microsoft Internet Explorer DE Fie Edit View Favorites Tools Help av Q sx x a A gt Search Sie Favorites Meda amp 63 O Ci A B Sa GA hipe A92 WOR L0 i eena ieee _ Ho m Cu _ Series 4100 SkyRouter User Name Password Figure 4 Part Number 91 007 02 When you have completed the login process you will be presented with the top level administration menu Ctek SkyRouter Microsoft Internet Explorer Fie Edit View Favorites Tools Help E O O AG awe ke Gun O CDa JuD Address E http ctek0 1 thingme net admin bin s4100cgi cgi_main cgi J Eo a gt Google v pseachweb go PaveFank Eh 8137boded E G lorem waitin Cw Series 4100 SkyRouter INTERFACES SERVICES STATUS Password Routing C Rely inpu Relay Output OTA Services Applications Ctek Website Figure 5 Note that the administration menu is divided into three sections The Interfaces section deals with physical connectivity managing the connection and subtended devices Services are applications that are within the router core to modify the behavior of a specific interface or to change system wide parameters within the router core Status screens are provided for the CDMA2000 1XRTT and Ethernet interfaces Note The Restart button must be used to apply any changes made
13. c to wireless network For normal operation this parameter should be set to Yes In some unique situations you may connect the SkyRouter to a network where you will be given public address to use on your LAN s Ethernet segment In such cases NAT should be turned off NAT is currently required for operation on all US networks such as Sprint Verizon or Alltel Typical environments where NAT would be turned off would be private networks or some types of VPNs and in these cases the network operator will most likely provide configuration assistance Forward Inbound Port This table allows WAN side packets addressed for specific IP ports to be routed to a specified address on the LAN side Of Local Address Used to specify the LAN side address of the routing operation TCP Route TCP IP traffic UDP Route UDP IP traffic Enable Activate this routing setting Advertise This Service Display this named service for WAN users 16 Part Number 91 007 02 With Title The name assigned to this service A Ctek SkyRouter Microsoft Internet Explorer TER ar Fie Edit View Favorites Tools Help Address http etek0 1 thingme net admin bin sel_service cgi v Eco tints Google v Qdsearch web g Pernak Eh 5489blocked E automi E Eg opto Tos Crue Series 4100 SkyRouter CTEK01 THINGME NET 166 139 104 35 Ctek SkyRouter Demo San Pedro California GD imin Faciities
14. derations are reduced to the absolute minimum necessary to register and make connections on a network 1 1 Theory Of Operation The Series 4100E SkyRouter is a complete IP router that routes traffic over LAN Ethernet 10 100baseT connections The wireless features of SkyRouter simply extend the IP routing capabilities to include routing and network address translation NAT over CDMA2000 1XRTT wireless networks As with most routers Ctek s Series 4100E SkyRouter can be viewed as having a Local Area Network LAN side and a Wide Area Network WAN side Traffic originating at SkyRouter s Ethernet ports is considered LAN traffic The Wide Area Network connection is over the wireless network s 1XRTT transport 1 2 Features This manual covers SkyRouter 4100E Release 1 00 and contains the following feature and functions 1 Ethernet Static Addressing Dynamic DHCP Server DHCP Client Configurable DNS address Configurable Gateway Sub net mask and Broadcast address Port Forwarding Service management hoang 2 CDMA Interface Enable Disable Wireless Routing Enable Disable inbound IP requests Adjust inactivity timers Name Server Interoperability with UDP or SMS DDNS Interoperability with BIND or MS Server Administration web server port address selection Enhanced OTA and manual activation Home Network Selection sa oao7 D 3 Relay Contact Closure detection and operation a NO NC detection b SMS or email cry ou
15. er can be configured to operate as a DDNS using Ctek s proprietary Enhanced Wireless DNS EW UDP or EW SMS The SkyRouter may also be configured to operate with a standard DNS having Dynamic DNS capabilities Examples of this type of service would be Berkeley Internet Name Daemon BIND and Microsoft Server 2000 and up For detailed information see Ctek s TechNote S4100 01 Even if you elect to use a static IP address a DDNS service will add value in two ways First when the networks static addressing assignment fails there is a mandatory waiting period before the endpoint is allowed to reinitiate the request for a static address registration During this period of time the network will dynamically assign addresses to the end point A DDNS service will make the end point network addressable by name during this period of time Secondly a name service allows your end point to be known by a name that is independent of network addressing Addressing a unit by name may be easier for end users to remember and will over a long period of time reduce maintenance problems 4 1 Getting Started Once the PC has been set up properly and physically connected to the SkyRouter you are ready to begin configuring the Series 4100 SkyRouter for your application To access the Administration menu use a conventional web browser pointed at http 192 168 1 10 A login screen appears as shown below The default User ID is ctek without the quotes and the default P
16. fused with the Name Server entries on the Wireless Interface screen The DNS referenced by these addresses will resolve outbound queries IP Address The IP address assigned to the LAN segment of this SkyRouter NetMask This parameter is also known as Subnet Mask Network Mask determines which portion of an IP address is the network portion and which portion belongs to the host As an example a setting of 255 255 255 0 would indicate that the first three groups of this address 255 255 255 identify the network and that the last group 000 254 identify a particular host Default Gateway The Default Gateway is the address of a device that SkyRouter will use to reach remote networks or servers In many cases this will be a firewall address In a normal situation where the 4100 is acting as a fringe router and is expected to pass incoming Ethernet traffic through to the CDMA network this field should be left blank If the 4100 is acting as a RAS where traffic is coming in from the CDMA network so that it can be routed through to some sort of host server this field must set to the address of the 4100 s Ethernet port Broadcast Address If applications on the 4100 need to do a broadcast operation this is the address that will be used on the Ethernet segment to fulfill the broadcast request Part Number 91 007 02 4 2 3 Configuring The Relay Input Interface This screen configures the connection characteristics of the relay input i
17. her a standard Ethernet cable or a reverse cross over Ethernet cable Terminal Block Connector J1 supports three separate functions power relay contact closure detection and the relay driver output The pin out configuration is as follows Pin 1 Relay in Sense Voltage Source 3 3vdc with over current protection Pin 2 Relay In Sense Pin 3 Relay Out Voltage Source 12vdc 40ma or less Pin 4 Relay Out Control Pin 5 Ground Pin 6 12VDC Antenna Connector Standard SMA type female connector Part Number 91 007 02 Ethenet Ports 1 4 Power and Relay Connections Figure 2 2 3 Lights The Series 4100E SkyRouter has indicators as shown in Figure 1 The network status indicator should be interpreted as follows NO IP CONNECTION When there is no connection the led will be in the off state If there is low signal less than 88dBm you will see one 200msc blink on every 4 5 seconds if there is good signal quality you will see two 200msc blinks on every 4 5 seconds IP CONNECTION If there is a connection the led will be in the on state If there is low signal you will see one 200msc blink off every 4 5 seconds if there is good signal quality you will see two 200msc blinks off every 4 5 seconds 3 Start Up Warning You must connect an antenna to the SMA style antenna connector on the SkyRouter before turning it on Failure to do this could result in erratic start up behavior and could possibly damage
18. less WAN connection will be made Disabled Never connect to the wireless network On Demand Only connect when there is outbound traffic to route Always On SkyRouter remains connected to the wireless network independent of whether there is outbound traffic or not In this mode SkyRouter will automatically reconnect to the network if disconnected or if its IP lease expires Connection Inactivity Timeout When operating in On Demand mode this timeout parameter defines the length of time that the SkyRouter will remain connected to the wireless network If your Wireless Network Operator has a shorter timer it will take precedence over this setting Use Network s Dynamic IP Address For most networks this will be the correct selection Use The Following Static IP Address If your selected network is capable of provisioning a static IP address to your application check this box and enter the assigned IP address See TechNotes for network specific set up Enable LCP echo packets For most networks under most conditions LCP echo packets should be turned off meaning this box should be unchecked If your network is providing a highly managed connection you may need to turn LCP echo packets on If you have questions check with Ctek support Select DNS Type Used to select the appropriate protocol for your Dynamic DNS 1 None DDNS will not be used 2 EW SMS Use Ctek Enhanced Wireless DDNS with SMS updates 3 EW UDP
19. net Explorer Fie Edit View Favorites Tools Heb Q x amp x a A JO search Se Favorites A veda HO a Se Address 4B http 192 168 1 10 admin bin cfg_eth0 cgi Google vi BPSearchweb gA PaseFank AY Th 1922 blocked fi Cus Ethernet Configuration Media Type auto y DHCP Configuration DNS Address Source Disabled Enable Server O Enable Client Acquire From Wireless Network User Defined Primary DNS Address 66 174 3 7 Secondary DNS Address 66 174 6 7 When DHCP Client is enabled these paramters will be ignored IP Address 192 168 1 10 Net Mask 255 255 255 0 Default Gateway Broadcast Address 192 168 255 255 Figure 7 Media Type Determines the type of Ethernet connection Auto allows SkyRouter to determine what the connection is This setting is appropriate for most cases Other settings are to select either 10Mb 10baseT 100Mb 100baseT Full Duplex FD or Half Duplex HD Again in almost all cases Auto will correctly determine the proper setting DHCP Configuration These settings determine the network topology of the LAN side of SkyRouter s network Disabled You must manually configure the IP address and other addressing parameters described in the next section It is recommended that the SkyRouter be assigned a private static address of 192 168 1 10 Enable Server This SkyRouter must be assigned a private static IP address as defined in the next section It is
20. nterface and defines the service associated with this interface Currently the relay interface can cause an SMS message to be sent to another wireless device or an e mail message to be sent to any valid email address Z http 192 168 1 10 admin bin cfg_relay cgi Microsoft Internet Explorer File Edit View Favorites Tools Help Back x A Fh search Favorites Meda 4 7 m oe e amp E Address 48 http 192 168 1 10 admin bin cfg_relay cgi ESA Relay Input Configuration Relay Trigger Input Disabled On Closure On Opening Maximum Trigger Rate Aways SMS Destination Address 5857462032 SMS Alert Message Alert message from Ctek03 Figure 8 Relay Input Trigger Establishes the conditions under which the Relay Service will be invoked Unless it is disabled the relay input is sampled at 1000 millisecond 1 second intervals Disabled Never respond to relay activity On Closure Respond when relay contacts go closed On Opening Respond when relay contacts go open Maximum Trigger Rate This setting determines how often the SkyRouter will send a relay event message If the relay event is recurring at a rapid rate this setting will prevent an undesirable flood of messages If Maximum Trigger Rate is set to Always the relay input is operating in edge triggered mode In this mode the SkyRouter will invoke its assigned service any time that the input transitions to the selected state
21. on specific Interface or Service screens Part Number 91 007 02 4 2 Interfaces 4 2 1 Configuring The Wireless Interface The configuration screen for the wireless interface is shown below The actual wireless interface is provisioned and configured by the wireless Network Operator SkyRouter s Wireless Interface Configuration screen is used to establish inactivity timeouts and Name Server selections v Eco Links gt iloptoss Address http 192 168 1 10 admin bin s4 100cgi efg_cdma cgi l p Google v psearchwed ge PaseRek Eh 7745boded E fat Wireless Interface Configuration a Network Select Auto xj User Name 3102705409 vzw3g com Connection Type Always On i Password eee Inactivity Timeout Never Use network provided dynamic IP address O Use the following static IP address Enable LCP echo packets g Client For Dynamic IP Address Resolution Select DDNS Type O None OEW SMS EW UDP O Standard UDP Device Name ctek03 thingme net Primary Name Server 68 15 89 150 Secondary Name Server Provide Network Name Server Facilities O Yes No Figure 6 Network Select This pull down menu allows the user to control the home network setting of the CDMA connection effectively limiting the scope of the Preferred Roaming List PRL assigned by your wireless network operator There are four possible settings 1 Auto Auto is the
22. otes for specifics Response Network responses to OTA commands Consult Ctek s Activation TechNotes for specifics 4 3 5 Applications Beginning with Firmware Release 2 02 the 4100S SkyRouter is capable of installing and managing custom applications The Applications Services screen is the user interface to manage custom applications The individual application release documentation will document the individual applications behavior Address 48 http 192 168 1 10 admin bin s4100cgi apps_services cgi Eo ins Google v searchweb PageRank 57745 blocked FE 2 Fg Options Figure 14 20 Part Number 91 007 02 4 4 Status 4 4 1 Wireless Status This status screen provides information about the wireless interface such as ESN and MIN that will be needed if you are having problems with the wireless network Signal level can also be used to validate antenna placement Information on this status screen originates either from the Wireless network or from the CDMA 1XRTT radio within SkyRouter http 192 168 1 10 admin bin stat_cdma cgi Microsoft Internet Explorer File Edit View Favorites Tools Help Back x 2 A Search Favorites Ameda 4 A i Y im U 7 a E k F Address 4 http 192 168 1 10 admin bin stat_cdma cgi wN Cios Wireless Interface Status ESN Dec 15908739441 ESN Hex 9F855A71 System ID 154 Phone Number MIN 3102705409 Network Status In Service Sign
23. rrent Status field is Active this is the IP address that the wireless network has assigned to your SkyRouter during this registration If Current Status is inactive this is the last IP address assigned Call Type Text provided by the wireless network indicating the type of call that is in progress No Call In Progress Circuit Switched A Circuit Switched Data CSD call has been established Packet Relay Model 1XRTT packet call using IP services provided by the endpoint Packet Network Model 1XRTT packet call using IP services provided by the network Packet Mobile IP Advanced packet type call supporting roaming and handoff Call Status Indicates the current status of network registration Idle Not registered disconnected Connected Registered and active on the network Dormant Registered but inactive Ended The current call has been terminated 22 Part Number 91 007 02 4 4 2 Ethernet Status Indicates the current LAN side IP address that the SkyRouter is using MAC Address is a vendor and machine specific identification code Z http 192 168 1 10 admin bin stat_eth0 cgi Microsoft Internet Explorer File Edit View Favorites Tools Help ay Q mx amp a E A JO search Sie Favorites QD veda E 2 a r E P Address http 192 168 1 10 admin bin stat_eth egi sis Ao mw t Ethernet Interface Status SEO Current IP Address 192 168 1 10 MAC Address 00 40 8C CD 00 00 Figure
24. standard mode of operation and should continue to be used in most cases In the Auto mode of network selection the entire PRL is considered for serving network connections 2 Home Only In Home Only mode serving network connection choices are limited to those defined as Home in the PRL Part Number 91 007 02 3 PCS Home Only In PCS Home Only mode serving network connection choices are limited to those PCS 1900MHz defined as Home in the PRL 4 Cellular Home Only In Cellular Home Only mode serving network connection choices are limited to those Cellular G00MHz defined as Home in the PRL Warning If the Series 4100 SkyRouter is transported from one location to another Network Selection choices other than Auto could cause the unit to fail to make a network connection For instance if the Network Selection mode was set to PCS Home Only and the unit was transported to a location not served by PCS or an area where the PCS network was not included in the PRL the connection would fail Ctek recommends that Auto mode should always be used unless problems are detected If selections other than Auto are required the user should then evaluate operation in Home Only Network technology specific choices PCS Home Only and Cellular Home Only should only be used as a last resort User Name and Password Required for activation on some networks See TechNotes for specific usage Connection Type Used to manage conditions under which a wire
25. t alarm 4 Relay Driver Output Part Number 91 007 02 a SMS Activation b Web Activation 5 General Administration a Modify Password 6 Status Ethernet Status a Currently Assigned IP Address b Current MAC Address 7 Status CDMA Status ESN Serial Number Hex and Decimal Network Assigned IP Address Telephone Number MIN Current Network Status Active Inactive Signal Level RSSI oao0o0o 1 3 What Is In The Box The following items are included with your SkyRouter 1 Series 4100 SkyRouter 2 Antenna 3 12VDC Power adapter 4 Documentation CD Part Number 91 007 02 2 Connectors Lights Switches and Jumpers 2 1 Switches Referring to Figure 1 there are two switches on the back of the Series 4100E S1 Reset causes a hard reset of unit S2 Restore Defaults is used to completely restore the firmware settings that were included when the product was shipped from the factory To restore factory defaults the unit must be running Press the Restore Defaults inner switch and hold it down for 10 seconds After 10 seconds you will see both the green and yellow lights go off At that time you may either press the reset outer switch or cycle power on the unit Network Status Ethernet Activity Factory Power Defaults Figure 1 2 2 Connectors Ethernet Connectors Connectors are found on the front of the Series 4100E SkyRouter Ethernet ports 1 4 are auto polarity sensing and can be used with eit
26. the Advertising feature is used the Administrative Login screen will no longer greet incoming WAN users instead they will be presented with a Services screen as shown in Figure 15 15 Part Number 91 007 02 Ctek SkyRouter Microsoft Internet Explorer Fel Edt View Favorites Tools Help ay Q O AOD Pave Jers Sue O SSS WHSAS Address http ctek0 1 thingme net admin bin cfg_route cg Wij E so ks Google v Bseachwed GB Pathak Disasoblocked E Pad options A af Cue _ Routing and Forwardin 4 Block Inbound IP Traffic From Wireless Network O Use NAT on all Ethernet traffic to wireless network Forward inbound port 190 o port 80 Of local address 192 168 1 199 CP V UDP M Enable v Advertise this service With the title Ctek SkyRouter Demo San Pedro California Forward inbound port o port Of local address 192 168 1 JDP Enable Advertise this service With the title Forward inbound port o port Of local address 192 168 1 CP UDP Enable Advertise this service With the title Figure 10 Block Inbound IP Traffic From Wireless Network If set to Yes the SkyRouter s firewall is configured to block any inbound originated but not response packets from the wireless network WAN This firewall is then selectively modified by the forwarding entries defined through this screen If this parameter is set to No the SkyRouter s firewall is disabled Use NAT on all Ethernet traffi
27. the unit 3 1 Power Before starting connect the supplied 12VDC power adapter to the power connector described in Section 3 The adapter supplied with your SkyRouter is suitable for use with 120VAC 60 hertz wall power If you need a different power solution contact Ctek Part Number 91 007 02 3 2 Connecting The Antenna The antenna supplied with each SkyRouter should be attached to the SMA style antenna connector described in section 3 The antenna must be connected before powering the unit on 3 3 Connecting to the Ethernet Port Administrative Connection For a direct Ethernet connection between a PC connect to any of the Ethernet ports using a standard or reverse Ethernet cable For initial configuration and administration with a PC or workstation Ctek recommends that the PC be set to obtain an IP address and obtain a DNS address automatically For Windows PCs make the following settings under the networking control panel LAN Ethernet Connections Windows General Authentication Advanced General Atemate Configuration s You can get IP settings assigned automaticaly your network supports Connect using this capably Otheresee you need to atk your nebiodk achrinitator fo settings Reakek RTL8139 Famy PCI Fast Ethernet NIC the appropriate IP Obtain an IP address automatically This connection uses the following items re Soma NOIE BEEE Chent for Microsoft Networks Prins Subnet mask
28. tions Title 47 FCC Rules and Regulations Part 15 Operation is subject to the following two conditions 1 This device may cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Test Report FCC Report SC400074 06 Industry Canada SC400074 06A Testing for compliance with Measurement Requirements CFR 47 Part 22 Paragraph 22 917 b 2 and Part 24 Paragraph 24 238 a FCC Report SC400074 03 Industry Canada Report SC400074 03A WARNING To reduce any possible hazard due to exposure of the human body to electromagnetic radiation per FCC OET Bulletin 65 this device is approved for operation using the antenna provided The antenna installation must provide a separation distance of 20 cm or more between the antenna and all persons to satisfy Maximum Permissible Exposure MPE compliance 25