1. seconds N OFF AU NUAL Step2 The Pollution light is out and the light stick of indication is on as in CO the drawing TT NERENE Step3 You can adjust the sensitivity by pushing Auto Manual button stage1 sensible stage2 3 standard gt insensible stage4 insensible standard sensible Step4 You can confirm the sensitivity which you did by pushing the Air i Flow button AUTO MANUAL A PLASMA CLEANING METHOD A WARNING Unplug power plug before cleaning Cleaning a Particle Sensor amp Odor Sensor Every 2 months O Please clean the ventilation inlet and outlet of sensors with a soft brush or a vacuum cleaner Please wipe the lens with a cotton swab soaked with water and get rid of moisture by using dry one Filter Cover Cleaning Please remove the dust clung to surface with a soft brush Clean the unit with a wet cloth if the unit is severely contaminated R Do not use an abradant eZ Body Cleaning O Please wipe it with a soft and dry cloth In Case that it is severely contaminated wipe it with a little bit wet cloth Do not use an abradant 19 20 CLEANING METHOD Cluster lon Electrode Part Cleaning Every 2months Please get rid of dirties on the charged body and the electric discharge pin of the cluster wit
2. BEFORE ASKING A S Troubles SI td Troubleshooting checked Is there dust around the particle sensor lens Remove the dust Refer to Page 18 Is the degree of pollution Adjust the sensitivity of particle PSA indicated to the high for a long sensor to the low Refer to Page not change time 18 Adjust the sensitivity of particle sensor to the high Refer to Page 18 Is the degree of pollution indicated to the low for a long time Has the period of filter replacement and cleaning passed There is a bad smell in a ventilation outlet Clean filters or replace them Install the RBD Plasma filter on the unit after checking its formation Is the RBD Plasma filter systematically put in the unit LARA is twinkling Is the tungsten wire down Please request for A S Is the particle sensor or the Please request for A S odor sensor is twinkling In case other functional defects occur After checking problems pull out the electric plug and request for A S WARRANTY INFORMATION Product Guarantee Parts and components shall be replaced free of charge within the guarantee period if the defects occur due to manufacturing defects in normal operation Contact us in case of breakdown In the following cases repair work shall be charged even within the guarantee period Breakdown caused by careless operation or unreasonable repair and renovation gt Breakdown cau
3. in the indication part after turning on the unit Plug the power cord to the voltage rating that matches on the rating plate Voltage rating that matches it on the rating plate _ gt If you push the ON OFF button the unit operates on automatic mode according to the indoor pollution degree The Auto light is on in the indication part at first AUTOIMAL The silent operation at night This function can only operate on automatic mode J gt X If the pollution of 1step is lasting over 10 minutes the air flow is lowered to 50 of 1 step It is a function set to be automatically transferred to the sleep mode Air flow rate e keeps at the ultra low fan speed through Cue a sensor detecting the luminosity of light around the unit Ifyou select a manual mode or the light density is strong sleep mode is automatically set off RS WOONGJIN COWAY CO LTD CAIRS AP 1503CH UAL AIR FLOW PLAS ON OFF AUTE HOW TO USE How to adjust the pollution sensitivity The unit is set at a standard sensitivity In case that pollution degree is maintained at the highest or the lowest level for over 2 hours after the unit starts to work please adjust the sensitivity of sensor as the following the way below Step1 Push both the Auto Manual and Air Flow just over 2
4. cleaner on the inclined place and let it fall or impact It may cause a breakdown by an electric shock Please have the unit serviced by the A S center if it makes smoke or a noise Do not put glasses metals others on the unit e Do not block the filter cover the ventilation inlet or outlet with a paper or a cloth It may cause the lower performance of the product or the fire e Do not let kids climb and hang on the air cleaner 94 E 1 2 Z S 3 Q e S e Do not put acute objects such as a gimlet in sensors of the unit Never use and put the flammable gas or inflammable materials near the air cleaner Never soak the unit in the water Do not modify disassemble or repair this appliance by yourself Do not wipe this appliance with benzene or paint thinner Do not use aerosol sprays near this appliance 07 08 FEATURES OF AIR CLEANER AIR CLEANER AP 1503CHE The filter system is optimized to remove quickly pollutants The unit contains the HEPA filter made of Nano Silver and Catechins which can be helpful for removal of bacteria minute particles The deodorizing ability is improved by using AC deodorizing filter and RBD plasma antibacterial catalysis system which can eliminate not only harmful gases such as volatile organic compounds VOCs Ammonia Aldehyde but food and cigarette odors and so on Turbo fan increases the air flow rate and treat
5. e unit after removing their packing sheet Step1 Open the filter cover by pulling the right side of the cover Step2 Please take out the filter by pushing the both hooks of the filter and remove its packing sheet suonsn1su Bunerado Step3 Please install filters according to the following order AC deodorizing filter antibacterial catalysis filter RBD plasma filter HEPA filter medium filter pre filter Check the insert direction of filters and make the both hooks fixed into the unit l Step4 Please close the filter cover 15 16 HOW TO USE In case of manual mode Select manual mode with the Auto Manual button after turning on the unit Plug the power cord to the voltage rating that matches on the rating plate Voltage rating that matches it on the rating plate It operates on automatic mode by pushing the ON OFF button S GAINS ZZ Push the Auto Manual button The Manual light is on ON OFF AuTi Set up the air flow rate by pushing the Air Flow button I y OFF AUTO MANUAL Al PLA In case of automatic mode The Auto light is lighting
6. fety 04 Operating Instructions Features of Air Cleaner mmm 07 Names of Each Part oee 09 Indication Part ES SOET TEETE A 10 Names of Internal Filters 77777 11 Operation Part OCZNE 13 Pre operation Instructions 14 How to Use wez aoi 15 Cleaning Method cnn 18 Filter Replacement CE 22 Troubleshooting Tips Before Asking A S RIN OR SERS eae BELG 24 Customer Service Warranty Information 26 IMPORTANT SAFETY INFORMATION Read All Instructions Before Using WARNING For your safety the information in this manual must be followed to minimize the risk of property damage or personal injury 94 E 1 2 Z S 3 it e 3 Electricity Safety e To avoid fire or shock hazard plug the air Voltage rating cleaner directly into a electrical outlet And ABB Mii plate be sure the unit is in a room to protect it from the moisture Always unplug the air cleaner before moving it replacing the filter cleaning it or whenever the air cleaner is not in Use e Do not plug in or unplug the power cord with wet hands or get the plug wet to avoid electric shock Never operate the air cleaner if it has a damaged cord or plug if it is not working properly or if it has been damaged Have the unit serviced by a qualified man Do not repeatedly plug in or unplug the I power cord fe e Periodically remove dust from the power plug with a dry cloth Dust lay on t
7. h soft brush of cotton swab ion after opening a ventilation grill with a screw driver Pre Filter Cleaning Every 2 4 Weeks Please open the filter cover by pulling forward the right side O Please pull the pre filter up as in the drawing Please remove dust with a vacuum cleaner or water Please install the filter to make the both hooks fixed into the unit and then close the filter cover after complete dry of the filter A WARNING Unplug power plug before cleaning Install the RBD Plasma filter and the Antibacterial Catalysis filter in the unit after complete dry RBD Plasma Antibacterial Catalysis Filter Please open the filter cover by pulling the right side of the cover e 8 S Z Q S oe S O 2 9 3 D Please take out the plasma antibacterial catalysis filter and then divide the filter into two pieces by pushing both hooks of the filter When you clean the RBD plasma filter please wipe the tungsten wire the dirties on the electrode with a wet cloth and then make it dry with a dry cloth x Never splash the water in the unit or soak it in water x Be careful about the down of the tungsten wire x Please completely dry in case that the water gets into the inside of the filter If the inside is taken by water please use after dry over 12 hours CLEANING METHOD Plea
8. he unit can cause bad insulation and a fire may occur due to it When unplugging the power cord never pull the cord to plug out Please carry the unit by using a handle in the back of it Do not use to connect or transform 4 an electric wire without permission Be sure the power cord not to be bend by force and do not put a heavy Oo object on it to avoid any electric LO leakage or damage gt sz z Y e Don t plug in a number of electrical SAA goods in an outlet at the same time o Srogi Just use the outlet for only the air Op a cleaner pe Please plug out if you are not use the unit for long time 94 E 1 2 Z S 3 Q e S Installation amp Use Safety Never splash the air cleaner with water to avoid the risk of electric shock To avoid fire hazard never put the cord under rugs and near heat resistors radiator stoves or heaters Keep the air cleaner out of direct sunlight The sun s heat may distort non metallic parts and may damage the electric components It should be installed more than 20cm away from walls or objects and more than 30 60cm low from the ceiling If it is too close to walls or objects it could cause contamination in the surroundings 05 06 Do not install the air
9. ich can be very useful in not only the minimum of ozone generation but also the removal of the germ and mold HEPA Filter The HEPA High Efficiency Particulate Air filter is used to filter cigarette fumes bacteria and minute dust Medium Filter It is made of special antibacterial medium to filter large substances mold and bacteria bigger than 1um and to hold on the ability of the HEPA filter Pre Filter It is made of antibacterial material and filters comparatively large dust hairs pet dander mold and etc 13 14 OPERATION PART IR WOONGJIN COWAY CO LTD CAIRS AP 1503CH ON OFF AUTO MANUAL AIR FLOW PLASMA ON OFF It is used to turn on and off the unit Auto Manual The unit starts to work on the automatic mode by pushing Auto Manual button and the air flow rate is automatically adjusted through particle amp odor sensor depending on the indoor pollution degree You can choose the manual mode by pushing the button during the auto mode control the airflow which you want by Air Flow button AIR FLOW You can select the rate of air flow as you push this button Step1 Step2 Step4 Turbo Rhythm cleaning Please use the Turbo operation when the air is highly polluted Plasma When the unit is in RBD plasma mode it can remove the odor the germ from the air by pushing Plasma button PRE OPERATING INSTRUCTIONS A WARNING Install filters on th
10. onths Cleaning filter Every 2 years Replacement AC Deodorizing filter Every 2 years Replacement x The period time of filter of replacement is based on the use of 24hours a day at step 1 mode And it could be different accordirg to the surroundings BEFORE ASKING A S Check the followings before requesting for A S It can not operate properly because of trivial problems or a lack of user s experience even if it is not out of order In those cases please check the followings carefully to solve problems Please call A S center if you have any problems except the followings Troubles Fa lee Troubleshooting checked Plug the power cord to the voltage rating that matches on the rating plate Is the plug inserted O Ko EN La 3 Q 5 4 S 9O S O 3 7 No air comes out Turn the power on and select indication li 2 Are the indication lights off AU Is the electric power off Operate it after the power is on In the automatic mode the air flow rate could not selected by hand operating Is the Auto Manual light of the indication part on The air fiow rate does not change In the sleep mode you can not Is the room dark operate an air flow rate sdij Buljooysajqnoiy The output of the GEE a airflow is Is the time of the pre filter CENIE WETO EPE AECE WIEM considerably cleaning passed A the period for weakened i 23 26
11. penses by using BLDC Motor 09 10 NAMES OF EACH PART Side Odor Sensor SED Operation Part Ventilation Indication outlet i J Part Particle m Filter Sensor Cover Handle Power Cord INDICATION PART Indicator of Auto Manual It indicates whether the unit is operatin m p g on automatic mode or manual mode Operating mode is selected with the Auto Manual button Indicator of Sleep Mode It indicates the unit is operating on sleep mode and this mode is available on automatic mode Indicator of Cluster Negative lons It indicates the discharges of cluster negative ions with the clean air together Indicator of Air Speed You can see the condition of the air flow because the revolution speed automatically changes according to the air flow Indicator of Air Flow Rate Rhythm The unit operates automatically according to the indoor pollution degree on an automatic mode You can select the mode among the rate from 1 to 4 step turbo and rhythm cleaning mode with the Air Flow button on a manual mode Rhythm Cleaning Indicator It is the mode to efficiently get rid of pollutants The change of the air flow can be efficiently controlled by rhythmical operation of the unit Indicator of Pollution Degree It is the mode to remove pollutants from the inside air according to the rhythmical operation It efficiently controls the change of air flo
12. s Indoor pollutants very quickly Yas by rhythm cleaning system LGW AR ILATZWZY 0 z V UI il yes A A WV ITA 7 Wess Y NS Y It allows you to check the status of indoor pollution through a particle sensor on a real time bases Besides it minimizes electric consumption by automatically adjusting fan speed according to the indoor pollution degree Itis designed to be automatically switched to the silent operation by sensing light to provide a quiet and pleasant environment at the dark The operation of the air cleaner stops by safety switch when the front cover is opened The ventilation inlet and outlet are designed for the sake of safety to prevent the risk of accidents suon nnsuj Bunelado We complexly applies RBD Plasma system and antibacterial catalysis filter which can remove harmful gas and the floating bacteria You can save the maintenance cost because a regular cleaning can extend the average life span of the filter besides RBD Plasma Catalysis System generates plasma which is the 4th condition of materials RBD plasma system is made of the special silicon barrier for the stable electrical discharge and gives full play to the genius in the removal of the bacteria mold This air cleaner can materialize a plenty of cluster negative ions which can make the inside air more clean by eliminating the activated oxygen and the static electricity You can cut down your ex
13. se clean the antibacterial filter with the brush or the vacuum cleaner after the division from the RBD Plasma filter x Be careful of damage to the filter x Even though the filter may get damaged such as a transformation and minor breaks there is no problem for use O Please put the antibacterial catalysis filter together with RBD plasma filter Please close the filter cover after putting the filter in the unit x Please check the Installing Direction of RBD plasma filter FILTER REPLACEMENT AWARNING Unplug power plug before filter replacement WARNING The period time of filter replacement should be different according to the surrounding pollution degree of pollution time of using Step1 Open the filter cover by pulling the right side of the cover e 8 S z Z Q 5 a S 9 2 9 5 2 Step2 Separate filter that you want to replace from the filter case Step3 Please put the filters in the unit with the opposite direction and then close the cover after filter replacement 23 24 FILTER REPLACEMENT Estimated Time of Filter Replacement and Cleaning Item Period Time Method Pre filter Every 2 4 weeks Cleaning Medium filter Every 2months Replacement HEPA filter Every year Replacement RBD Plasma filter Every 2months Cleaning Antibacterial Catalysis Every 6m
14. sed by nonperformance of the instructions specified in the manual Even after the expiration of guarantee period it is possible to apply for charged repair Present this Letter of Guarantee whenever repair is needed ORO G aro This Letter of Guarantee is valid only in domestic where you buy this product Keep this Guarantee carefully as it is not re issued LRL GANO Product Name Coway Air Cleaner Guarantee Period Model AP 1503CHE RAA CHNO Serial No 5 Date of Purchase exe PRD A Guarantee Period yas R ANO Q X Customer s Address e GLK LALKI ero Customer s Name Roa exe Please contact our customer s service center in case you are not satisfied with our A S service Nationwide A S Call asl Customer counselling Center Call Fax In case any other filters or parts which are not genuine products of Coway are used Coway is not responsible for any problems related to air quality Coway Co Ltd 658 Yoogoo Ri Yoogoo Eub Gongju Si Choongnam Province Korea GER AO Gaye sdi 6unooysa qnol S 4awojsng OJIAJO 706900160 Coway Co Ltd www coway com 1 Da
15. w Indicator of Odor It indicates the degree of the indoor odor pollution Z PLASMA Indicator of Plasma When you push Plasma button it indicates the working of Plasma e 8 S S 5 Q 5 2 S O 2 9 3 a 12 NAMES OF INTERNAL FILTERS Filter Cover It makes filters safe in front of them The purification ability can be well because the filter cover is designed able to inhale the air from 5 different ways Natural Cluster Negative lons It removes the activated oxygen the static electricity from the inside air and helps to promote health by discharge of the cluster negative ions AC Deodorizing Filter It is complexly treated by the light catalysis and the inorganic absorbent so it can control the harmful gas the bad smell Formaldehyde which is the cause of Sick House Syndrome Antibacterial Turbo Fan It generates the pertinent inhalation ability and air flow to the floor space so it can bring not only the efficient control of pollution but also the prevention of noise Antibacterial Catalysis Filter The filter is handled by the inorganic absorbent the light catalysis that is useful to get rid of Formaldehyde such as bad smells germs harmful gas RBD Plasma Filter It is the unique plasma system wh
16. z Co 15014001 m This product can not be used if the voltage is different from that mentioned in the rating plate m The Letter of Guarantee is enclosed here with this Coway product realizing Quality is the best policy AP 1503CHE User s Manual Do not fail to read this user s manual before you use this air cleaner and keep it within ready reach 01 02 DEAR COWAY S CUSTOMERS First of all we would like to thank you very much for purchasing this air cleaner This product is superior to the ones in the past in function and we believe that it will provide you with clean and healthy air We would like to recommend you to read this User s Manual carefully for proper operation and maintenance and keep this manual well together with the warranty This user s manual could help to solve your problem ey Read this Manual Inside this manual you will find many helpful hints on maintaining your air cleaner properly Just a little preventive care on your part can save you a great deal of time and money over the life of your system Review the Section on Troubleshooting Tips You ll find many answers to common problems here If you review this chart of Troubleshooting Tips first you may not need to call for service at all If You Need Service If you do need service you can relax knowing help is only a phone call away Safety Information Electricity Safety a ola 02 Installation amp Use Sa