Home

Cooper Lighting Tribute IMI-685 User's Manual

image

Contents

1. anchor leads in place so they are not in contact with the reflector surface or ballast surface e Replace electrical compartment cover removed in step 3 Tribute Sheet 2 of 4 FIG 4a Arm Mount Pole Cap CS q g ao van Nut Plate J q F EE P D Arm Drain Hole Hex Nut InThis Location Lock Washer 1 2 13Threaded Rod Max extension into housing is 17 Cross Sectional View of Fixture Mounted to Pole FIG 4b Internal Mast Arm Mount 2 or 11 2 Service Lead Wires Extend Min 6 Flip Clamps over for 1 1 2 Pipe Housing Stop Electrica Cover Detail A Tear off this part of gasket for 2 pipe size Tenon Clamp Bolts qty 4 Torque to 100 inch pounds 1 7 08 IMI 685 These instructions do not claim to cover all details or variations in the equipment procedure or process described nor to provide directions for meeting every possible contingency during installation operation or maintenance When additional information is desired to satisfy a problem not covered sufficiently for user s purpose please contact your nearest representative NOTE Specifications and dimensions subject to change without notice Visit our web site at www cooperlighting com Customer First Center 1121 Highway 74 South Peachtree City GA 30269 770 486 4800 FAX 770 486 4801 ADHO070937 ae COOPER Lig
2. M Lighting Tribute INSTALLATION INSTRUCTIONS i IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE WARNING Risk of Fire Electric Shock If not qualified consult an electrician WARNING Risk of Electric Shock Disconnect power at fuse or circuit breaker before installing or servicing A WARNING Risk of Burn Disconnect power and allow fixture to cool before changing bulb or handling fixture WARNING Risk of Personal Injury Fixture may become damaged and or unstable if not installed properly Tighten all fixture components to their recommended torque values Ensure door is properly latched WARNING Risk of Fire Electrical Shock Upside down installation can result in overheating or accumulation of water in fixture Install right side up Tools Required Socket 5 16 Socket 3 4 Deep Well Socket Electrical wiring tools NOTE these luminaires are designed for outdoor lighting services and should not be used in area of limited ventilation or in high ambient temperature enclosures Construction is suitable for down lighting only Best results will be obtained if installed and maintained according to the following recommendations 1 Open housing door by squeezing thumb latch towards front of housing To relieve latch pressure compress gasket by pushing door into housing Once the latch is disengaged gently swing the door open FIG 1 2 Remove the door by opening it to 45 angle half open half closed then lift it off the
3. South Peachtree City GA 30269 770 486 4800 FAX 770 486 4801 ADHO070937 PAR a Lighting Tribute INSTALLATION INSTRUCTIONS IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE 6 Light Distribution Some of the reflector options are directional oriented The reflector can be rotated in 90 increments Loosen reflector mounting screws and rotate reflector to desired orientation and then retighten the mounting screws FIG 6 Tools required 1 4 socket 7 Wiring Important Dual voltage and multi tap ballasts are factory wired for 277V input Before installation make certain supply and ballast voltages are compatible For use with other line voltages remove wire nut splicing the black lead from the quick disconnect plug and 277V lead from ballast Cap off 277V lead with wire nut Splice black lead from the quick disconnect plug with desired voltage lead from ballast Wire leads are to be routed from housing to pole All wiring connections are to be made in the pole Wire the fixture voltage leads to the supply voltage lead fixture common lead to the supply neutral lead and the fixture ground lead to the supply ground lead If fixture is supplied with the ballast tray option re connect the polarized plug and replace the ballast tray 8 Photocontrol Receptacle Loosen the two flathead screws to allow rotation of the receptacle Insert screwdriver into center slot and rotate receptacle until indicator arrow points north Retighten screws P
4. enance When additional information is desired to satisfy a problem not covered sufficiently for user s purpose please contact your nearest representative NOTE Specifications and dimensions subject to change without notice Visit our web site at www cooperlighting com COOPER Lighting Customer First Center 1121 Highway 74 South Peachtree City GA 30269 770 486 4800 FAX 770 486 4801 ADH070937
5. hook shaped hinges FIG 2 3 Remove the electrical compartment cover Hard Mount Version e Hard mount electrical covers requires captive screws 1 amp 2 to be loosened Grab handle and remove cover FIG 3a Power Tray Version e Power tray version requires captive screw 1 to be loosened FIG 3a e Grab handle and open power tray FIG 3b e To remove power tray from housing unhook pin through gap in power tray Slide off of back pin and unplug the electrical connection FIG 3c FIG 3a Screw 1 Screw 2 These instructions do not claim to cover all details or variations in the equipment procedure or process described nor to provide directions for meeting every possible contingency during installation operation or maintenance When additional information is desired to satisfy a problem not covered sufficiently for user s purpose please contact your nearest representative NOTE Specifications and dimensions subject to change without notice Visit our web site at www cooperlighting com COOPER Lighting Customer First Center 1121 Highway 74 South Peachtree City GA 30269 770 486 4800 FAX 770 486 4801 ADH070937 P COOPER Lighting INSTALLATION INSTRUCTIONS IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE Mounting the fixture 4a Arm Mount FIG 4a e Arm Mounting Square Pole Lay the fixture on its top with door removed Remove
6. hting P COOPER Lighting INSTALLATION INSTRUCTIONS IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE 4c Slipfitter Mount FIG 4c e The integral slipfitter can be mounted on 2 2 3 8 0 D pipe Set screws and a thru bolt are provided to clamp it securely to the tenon Thru bolt will require a drilled hole thru the arm or tenon Use the slipfitter as a pattern to drill the thru hole Secure electrical leads from the drill path Remove slipfitter and clean burrs on tenon from drilled hole Reinstall the slipfitter Remove the cover plate from slipfitter and bring leads into compartment Pull power supply leads and the ground lead into the bottom half of the slipfitter Be sure the pivot retainer bolt is tightened securely after aiming is accomplished Tighten all mounting bolts per FIG 4c 4d Trunnion Mount FIG 4d e f the unit is provided with a trunnion which can be mounted directly on a flat surface Adapters are available for installation on building fronts poles crossarms pipes etc 14 3 SO cable is recommended for making electrical connection The fixture is provided with a grommnet and a strain relief approximately 9 16 diameter To maintain the seal screws in the strain relief must be retightened whenever the seal is disturbed 5 Socket Setting Adjustment Type II or Type III Only FIG 5 e Socket is normally factory set to provide IES Type Il light distribution pattern To obtain IES Type Ill dist
7. lug the photoelectric control into receptacle and twist into locked position The photocontrol must contain a soft resilient gasket fastened to the bottom surface to assure a proper weather seal between the control and the receptacle NOTE The orientation procedure is only required for photocontrols which specifically require the cell to be aimed north Otherwise factory orientation will work Follow the directions recommended by the supplier of the photocontrol for proximity to light sources Lighted signs building surface reflection floodlights tree branches etc May affect final position of the photocontrol FIG 7 9 Lamp installation Open fixture door Install the lamp by grasping it close to the base and rotating clockwise tightening securely to engage socket center contact Close the fixture door NOTE Do not use lubricants on lamp base or socket as this will cause damage and void warranty 10 Reflector and Lens Cleaning Open fixture door dust reflector with soft clean dry cloth Do not use alkaline or acidic cleaners on reflector surfaces Clean lens with non abrasive glass cleaning solution NOTE A regular maintenance schedule should be followed to retain optimal light output and reduce heat retention These instructions do not claim to cover all details or variations in the equipment procedure or process described nor to provide directions for meeting every possible contingency during installation operation or maint
8. pole cap allowing nut plate to be inserted into pole and align with bolt holes Install threaded bolts into nut plate Align arm end with drain holes towards pole and place over threaded bolts Align holes in fixture with bolts Route fixture supply leads through arm and into pole Inside of fixture place lock washer and nuts onto threaded bolts secure Housing and arm must be square with pole Tighten bolts to 30 ft Ibs Bolts must not be extended into fixture more than 1 Finish securing electrical connections inside of pole e Arm Mounting Round Pole Installation is the same as square pole except a round pole adapter is used against the round pole 4b Internal Mast Arm Mount FIG 4b e Loosen the four tenon clamp bolts for insertion of the mounting tenon Note for the 2 pipe size tenon remove the tear away portion of the tenon entrance gasket To remove grasp the aluminum gasket with pliers and twist off the pre cut portion of the gasket e Pull service lead wires through the mounting tenon until about 6 extends beyond the tenon end e Slide the luminaire onto the tenon while guiding the service lead wires Make sure end of tenon is against stop in housing e Tighten 4 tenon clamp bolts Note fixture can be leveled by tightening front bolts differently than rear bolts When fixture is level torque all 4 clamp bolts to 100 inch pounds Tighten bolts in alternating pattern e Connect service lead wires to fixture leads and
9. ribution proceed as follows FIG 5 e Loosen the two 2 hex head clamping screws sufficiently for the socket to clear the indexing screws e Move socket bracket so that the indexing screws engage appropriate indexing holes See table FIG 5 for socket position and resulting light pattern Socket Indexing Indexing Screw 2 Hole Clamping Screw 2 Tribute Sheet 3 of 4 1 7 08 IMI 685 FIG 4c Slipfitter Mount bans Pivot Retainer Bolt Torque to 40 50 foot pounds 3 8 16 x 4 Set screw Hex Head Thru Bolt Torque to 15 20 with lock nut foot pounds FIG 4d Trunnion Mount 3 8 16 Bolt Torque to 120 140 inch pounds La 5 3 8 137mm Mounting Holes Light Pattern Socket Index Position IES Type 250W Clear HPS Lamp All other Clear 5 3 4 LCL HID Lamps 5 LCL Il A B Ill Cc NOTE Light Center Length D These instructions do not claim to cover all details or variations in the equipment procedure or process described nor to provide directions for meeting every possible contingency during installation operation or maintenance When additional information is desired to satisfy a problem not covered sufficiently for user s purpose please contact your nearest representative ae COOPER Lighting NOTE Specifications and dimensions subject to change without notice Visit our web site at www cooperlighting com Customer First Center 1121 Highway 74