1. 0 and or any other port numbers you wish to configure section Note Setting DECnet on for any port with the command line also sets DECnet on globally In CompatiView you must set a global parameter and a port specific parameter Chapter 2 Quickstart Instructions 11 SMDS Configuration This section covers the settings required for SMDS Switched Multi megabit Data Service operation of the V 35 WAN interfaces IP only SMDS is a connectionless packet switched service that offers LAN to LAN connectivity across a wide area at up to 1 544 Mbps SMDS addresses and other parameters can only be set using the command line interface Note The IP protocol settings and the physical communication settings are the same as they would be for Frame Relay operation The only parameters which should be set differently for SMDS are the Link Configuration and the SMDS addressing section Link Configuration SMDS is presently supported in the Octal V 35 Quad 10 100 RIOP only via synchronous dedi cated line operation e Set Dedicated connection e Set SMDS connection TB Use configure and then set the Mode and ConnectMode keywords in the Link Config WAN 0 and or any other port numbers you wish to configure section SMDS Addressing Many of these parameters will be given to you by your service provider TB Use configure and set the StationAddress PMulticast and PollingFrequency keywords in the SMDS WAN 0 and or any other port numbers y
2. 100 light indicates that the interface is operating at 100 Mbps Appendix A Connector and Cable Pin Outs 14 Appendix A Connector and Cable Pin Outs Pin Outs for HD D Sub Male to V 35 Male Cable V 35 DTE DCE Signal Chassis Ground Signal Ground Request to Send l Clear to Send Data Set Ready l Receive Line Signal Detect Data Terminal Ready i Tx Data Rx Data Tx Data Rx Data Tx Clock Out 4 Rx Clock In Tx Clock Out 4 Rx Clock In Tx Clock In Tx Clock In Zik gt lt lt cl 010 3 om ca o 0 wl TITITILITILITILITILILITITITI LITIST 1 Unused by the V 35 interface circuitry 2 Receive Line Signal Detect RLSD must be asserted by the CSU DSU when the WAN line is operational The CSU DSU should be configured to have RLSD follow the state of the link 3 Data Terminal Ready DTR will be asserted by the VSR V 35 circuitry when the VSR is ready to communicate 4 Used only when internal clocking has been selected
3. DECnet WAN INTERFACE CONFIGURATION Physical Communications Settings PPP Configuration WAN Link Configuration Required for Dedicated Leased Line Operation Suggested for Dedicated Line Operation IP Protocol Required for IP Suggested for IP IPX Protocol Required for IP X AppleTalk P rotocol Required for AppleTalk DE Cnet Protocol Required for DECnet Suggested for DECnet Frame Relay Configuration WAN Link Configuration Required for Dedicated Line Operation Suggested for Dedicated Line Operation Frame Relay DLCI Mappings as 00 DONNNNNNNNNDDDDDAODDDOAAAAIAIaIATtakKA AJA WWWNHND NY Table of Contents IP Protocol Required for IP Numbered Interface Suggested for IP IPX Protocol Required for IP X Suggested for IP X AppleTalk P rotocol Required for AppleTalk Suggested for AppleTalk DE Cnet Protocol Required for DECnet SMDS Configuration Link Configuration SMDS Addressing SAVING A CONFIGURATION FILE TO FLASH ROM Chapter 3 Shipping Defaults Ethernet Interfaces IP Routing Defaults IP Bridging Defaults IPX Routing Defaults IPX Bridging Defaults AppleTalk Routing Defaults AppleTalk Bridging Defaults DECnet Defaults WAN Interfaces Chapter 4 LED Patterns ROUTER LED PATTERNS Over Temp Sys Ready General Indicators OcTAL V 35 QUAD 10 100 RIOP LED PATTERNS Ethernet Traffic Indicators V 35 Traffic Indicators Ethernet Connection Indicators Appendix A Connector and Cable Pin Outs Pin Outs for HD D Sub
4. Male to V 35 Male Cable Introduction to the Octal V 35 Quad 10 100 RIOP 1 Introduction to the Octal V 35 Quad 10 100 RIOP The Octal V 35 Quad 10 100 Routing Input Output Processor RIOP as part of the VSR multigigabit switching router allows you to connect up to four local Ethernets and up to eight remote corporate networks Each of the V 35 interfaces has a data capacity of up to 2 048 Mbps while each Ethernet interface can operate at either 10 Mbps or 100 Mbps This section of the manual contains information specific to the Octal V 35 Quad 10 100 RIOP It is divided into the following sections Chapter 1 Network Installation Here you will find step by step instructions on how to physically install the Octal V 35 Quad 10 100 and connect it to your network Chapter 2 Quickstart Configuration The Quickstart section provides a basic list of parameters that must be entered into the Octal V 35 Quad 10 100 for proper operation Chapter 3 Shipping Defaults This section of the manual lists factory defaults for the interfaces Chapter 4 LED Patterns This section of the manual describes the LED indicators for the Octal V 35 Quad 10 100 Appendix A Cable Pin Outs This section of the manual describes the pin outs for the V 35 connector cables Chapter 1 Network Installation 2 Chapter 1 Network Installation Four 10 100BaseT Ports Yas Pots 0 3 1 35 Ports 4 7 PMP rar Ta Test Ethernet Octal V 35 Quad 10 100 RIO
5. characteristics of the interface They provide enough information for another IP node to find the interface such as a Telnet client but not enough information for routing to take place JP address JP subnet mask IP broadcast address CV Use the TCP IP Routing Ethernet Dialog Box to set these parameters TB Use the configure command and set the IPAddress SubnetMask and IPBroadcast keywords in the IP Ethernet 0 and or any other port numbers you wish to configure section Chapter 2 Quickstart Instructions 5 Suggested for IP These parameters help supply information about the segment that the interface is connected to With this information routing can take place e Set IP RIP 1 IP RIP 2 or OSPF Open Shortest Path First e IP static routes CV Use the TCP IP Routing Ethernet Dialog Box to set RIP and the IP Static Routing Dialog Box under Global IP Static Routes to set static routes OSPF can only be configured using text based configuration TB Use configure and set either the RIPVersion keyword or the OSPFEnabled keyword for the IP Ethernet 0 and or any other port numbers you wish to configure section Use edit config and add static routes in the IP Static section IPX Protocol Required for IPX Generally there are no required changes from the shipping Ethernet configuration for IPX The Ethernet interface will autoconfigure to use the two most common IPX frame types and will adapt to conditions on the Ethe
6. supplies To connect the router to the twisted pair network simply plug the twisted pair cable into one of the RJ 45 Ethernet connectors on the front of the unit Telco Line Connection Requirements The Octal V 35 Quad 10 100 is not a line communications device In order to connect each V 35 port to a wide area transmission line you must use a 56K CSU DSU ISDN Terminal Adapter or T1 El CSU DSU Which of these devices you use depends on the type of telco line you are connecting to lt Note Before attempting to connect the Octal V 35 Quad 10 100 to a leased telco line use the loopback features of your CSU DSUs to check the line This can save you a considerable amount of time since the more equipment you have on the line the more difficult it becomes to determine where a problem is occurring Chapter 1 Network Installation 3 The Octal V 35 Quad 10 100 RIOP is shipped with two Quad cables These cables have a single Very High Density D Sub connector which plugs into one of the Quad V 35 interface ports on the front of the device and then divides into four separate High Density D Sub HD D Sub female interface cables Note Port numbers 0 3 are stamped on both sets of Quad cables For ports 4 7 the connector marked Port 0 is Port 4 the connector marked Port 1 is Port 5 etc In addition there are eight HD D Sub male to V 35 male adapter cables The V 35 male connector plugs into the female V 35 connec
7. Octal V 35 Quad 10 100 RIOP Installation Guide Compatible Systems Corporation 4730 Walnut Street Suite 102 Boulder Colorado 80301 303 444 9532 800 356 0283 http Awww compatible com Octal V 35 Quad 10 100 RIOP Installation Guide Version 1 0 Copyright 1999 Compatible Systems Corporation All rights reserved VSR VSR 2 MicroRouter and CompatiView are trademarks of Compatible Systems Corporation Other trademarks are the property of their respective holders FCC Notice This product has been certified to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules It is designed to provide reasonable protection against radio or television communication interfer ence in a commercial environment Operation of this equipment in a residential area could cause interference with radio or television communication Table of Contents Introduction to the Octal V 35 Quad 10 100 RIOP Chapter 1 Network Installation Connecting the Octal V 35 Quad 10 100 to the Ethernet Telco Line Connection Requirements Connecting a Line Device to the V 35 Interfaces Connecting a Management Console Powering Up the Router Chapter 2 Quickstart Instructions ETHERNET INTERFACE CONFIGURATION IP Protocol Required for IP Suggested for IP IPX Protocol Required for IP X Suggested for IP X AppleTalk P rotocol Required for AppleTalk Suggested for AppleTalk DE Cnet Protocol Required for DECnet Suggested for
8. P Front Panel This section of the manual will help you install the Octal V 35 Quad 10 100 RIOP to connect up to four local Ethernets and up to eight remote corporate networks These connections can be made to other Compatible Systems devices or internetworking equipment from other vendors In summary the steps for installation are 1 After mounting the router or placing on a desktop make sure it is not connected to any power source 2 Connect the router to the Ethernet network s 3 Connect the router to the wide area communications device s 4 Connect a management console to the router optional 5 Power up the communications device s 6 Plug in the power cable and power up the router Connecting the Octal V 35 Quad 10 100 to the Ethernet The four 10 100 Ethernet interfaces directly support 100BaseTx or 10BaseT twisted pair Ethernet To connect one of the router s Ethernet interfaces to twisted pair Ethernet cabling you will need an unshielded twisted pair station cable that is already connected to a 10BaseT compatible twisted pair hub for a transmit speed of 10 Mbps or a 100Mbps Fast Ethernet hub for a transmit speed of 100 Mbps Note Ethernet cables and cable connectors are not supplied with the Octal V 35 Quad 10 100 RIOP product Category 5 cabling is required for 100 BaseT operation Please contact your reseller or your Compatible Systems representative for information on obtaining the correct Ethernet cabling
9. al information on IP IPX AppleTalk or wide area protocols see the Appendices in the CompatiView Management Software Reference Guide There are a number of parameter settings which are optional in the sense that they are not required for all installations These settings are not covered in this chapter In this chapter CV Compati View TB Text Based Configuration In order to successfully connect to an Internet Service Provider ISP you must use router configuration parameters which will be provided by the technical staff of the ISP These parameters must include all IP addresses WAN settings and any applicable authorization routines Please check with your ISP before changing the configuration of your Octal V 35 Quad 10 100 RIOP Note This Quickstart does not include information on setting up packet filters for using the router as a firewall See the CompatiView Management Software Reference Guide or Text Based Configuration and Command Line Management Reference Guide regarding IP packet filters for more information Ethernet Interface Configuration IP Protocol Ethernet interfaces are considerably easier to set up than WAN interfaces since there are fewer choices that need to be made regarding communications protocols and parameters We recom mend that you begin by configuring any Ethernet interface parameters before proceeding to configure WAN interface parameters Required for IP These parameters set the basic address
10. ay Configuration This section covers the settings required for Frame Relay operation of the V 35 WAN inter faces In general the parameters listed here should be set for each WAN interface on which you plan to use Frame Relay Note that some WAN interfaces can be running Frame Relay while others are running PPP The V 35 interfaces can only be run synchronously at rates up to 2 Mb per second WAN Link Configuration Required for Dedicated Line Operation Frame Relay is presently supported in the Octal V 35 Quad 10 100 RIOP only via synchronous dedicated line operation e Set Dedicated connection e Set Frame Relay connection CV Use the Link Configuration WAN Dialog Box TB Use configure and then set the Mode and ConnectMode keywords in the Link Config WAN 0 and or any other port numbers you wish to configure section Suggested for Dedicated Line Operation Dedicated line operation generally does not require additional parameters for operation Frame Relay DLCI Mappings If you are connecting to another Compatible Systems router this information is not required for Frame Relay operation Compatible Systems uses IARP Inverse Address Resolution Protocol to dynamically generate this information To connect to other vendors routers which do not support IARP you must provide DLCI to protocol mapping information Note Many Internet Service Providers ISP s do not support IARP as a default If your WAN interface will be connected t
11. de and ConnectMode keywords in the Link Config WAN 0 and or any other port numbers you wish to configure section Suggested for Dedicated Line Operation Dedicated line operation generally does not require additional parameters for operation IP Protocol IPX Protocol Chapter 2 Quickstart Instructions 7 Required for IP WAN interfaces which are set for PPP operation do not generally use an IP address They are set to act as an unnumbered interface In this mode of operation there are no required settings Suggested for IP These parameters help supply information about the segment that the interface is connected to With this information routing can take place Set IP RIP 1 IP RIP 2 OSPF Open Shortest Path First or BGP Border Gateway Protocol Set IP static routes CV Use the TCP IP Routing WAN Dialog Box to set RIP and the IP Static Routing Dialog Box under Global IP Static Routes to set static routes OSPF and BGP can only be config ured using text based configuration TB Use configure and set either the RIPVersion keyword or the OSPFEnabled keyword in the IP WAN 0 and or any other port numbers you wish to configure section Add static routes and a default router using the edit config IP Static command Note Due to the complexity of BGP configuration parameters for BGP are not given in this Quickstart For help with BGP configuration parameters and other configuration questions refer to the Tec
12. e Systems Technical Support if your router shows a hard ware failure Router LED Patterns The following LEDs and light patterns provide information about the VSR s physical state and operating conditions Over Temp The router is above the proper operating temperature The filter needs changing See the appropriate VSR chassis section of the manual for instructions Sys Ready The router booted properly without detecting any failures General Indicators Ethernet Lights V 35 Lights Indication 5 flashing 1 flashing Router stacks starting up 3 amp 4 flashing 2 amp 3 flashing No OS loaded Running from ROM 1 amp 4 flashing 2 amp 5 flashing Erasing OS in Flash ROM 5 flashing 1 2 amp 3 flashing Erasing config in Flash ROM 1 5 scanning 5 1 scanning Flash ROM erase due to switch setting five or six is complete Set switch to zero and cycle power Octal V 35 Quad 10 100 RIOP LED Patterns The following LEDs and light patterns provide information about the Octal V 35 Quad 10 100 RIOP interfaces Ethernet Traffic Indicators Scan from 1 to 3 Ethernet transmit packet Scan from 5 to 3 Ethernet receive packet V 35 Traffic Indicators TX WAN transmit packet RX WAN receive packet Ethernet Connection Indicators Link The Link light indicates that there is a good connection to the hub Activity The Activity light indicates that there is activity across the link 100 The
13. er port numbers you wish to configure section Suggested for IPX The settings above are all that is generally required for IPX operation over Frame Relay AppleTalk Protocol Required for AppleTalk Frame Relay operation requires that the WAN interface be set as a numbered interface This means that the interface and thus the Frame Relay network must have an AppleTalk network number and the interface must have an AppleTalk node number e AppleTalk numbered interface e AppleTalk network number e AppleTalk node number e AppleTalk zone name CV Use the AppleTalk Routing WAN Dialog Box TB Use configure and set the Numbered NetLower and DefZone keywords in the Apple Talk WAN 0 and or any other port numbers you wish to configure section Suggested for AppleTalk You may want to use more meaningful zone names CV Use the AppleTalk Routing WAN Dialog Box TB Use configure and set keywords in the AppleTalk WAN 0 and or any other port numbers you wish to configure section DECnet Protocol Required for DECnet In order to be used DECnet must be turned on both globally and for a particular port WAN interfaces which are set for Frame Relay operation do not need any additional parame ters set in order to function e Set DECnet on globally and for this port CV Use the DECnet Routing Dialog Box under Global DECnet Routing and the DECnet WAN Dialog Box TB Use configure and set the Mode keyword in the DECnet WAN
14. h Support pages on the Compatible Systems Web site at http www compatible com Required for IPX WAN interfaces which are set for PPP operation do not generally use an IPX address They are set to act as an unnumbered interface In this mode of operation there are no required settings AppleTalk Protocol Required for AppleTalk WAN interfaces which are set for PPP operation do not generally use an AppleTalk address They are set to act as an unnumbered interface In this mode of operation there are no required settings DECnet Protocol Required for DECnet The router s shipping configuration does not have DECnet turned on In order to be used DECnet must be turned on both globally and for a particular port e Set DECnet on globally and for a port e Set DECnet area e Set DECnet node CV Use the DECnet Routing Dialog Box under Global DECnet Routing and the DECnet WAN Dialog Box TB Use configure and set the Mode keyword in the DECnet WAN 0 and or any other port numbers you wish to configure section Use configure and set the Enabled Area and Node keywords in the DECnet Global section Note Setting DECnet on for any port with the command line also sets DECnet on globally Chapter 2 Quickstart Instructions 8 In CompatiView you must set a global parameter and a port specific parameter Suggested for DECnet Setting the parameters above should be adequate for most installations Frame Rel
15. l emulation 9600 bps 8 bits no parity stop bit and no Flow Control Note The Octal V 35 Quad 10 100 RIOP also has an AUX interface This is a modem connection which should only be used in consultation with Compatible Systems Technical Support staff who will provide instruction on its use Powering Up the Router Connect the supplied power cord to the front of the VSR and set the power switch to On At power up the router will take approximately one minute to become visible to Compati View Note If you want to use Telnet as a management method you must first configure an IP address into the router with an out of band console or reconfigure the IP address on an IP host or workstation on the same Ethernet segment as the router See the appropriate VSR chassis section of the manual for more information on Command Line Management Chapter 2 Chapter 2 Quickstart Instructions 4 Quickstart Instructions This Quickstart chapter briefly discusses the major parameters that must be set in order to use the Octal V 35 Quad 10 100 RIOP as part of your VSR multigigabit switching router Detailed information on the meaning of the router s parameters is provided in the Compa tiView Management Software Reference Guide and the Text Based Configuration and Command Line Management Reference Guide You should use this chapter as a starting point to look up more specific information in the other documents If you need more gener
16. n Suggested for IP These parameters help supply information about the segment that the interface is connected to With this information routing can take place Set IP RIP 1 IP RIP 2 OSPF Open Shortest Path First or BGP Border Gateway Protocol eIP static routes CV Use the TCP IP Routing WAN Dialog Box to set RIP and the IP Static Routing Dialog Box under Global IP Static Routes to set static routes OSPF and BGP can only be config ured using text based configuration TB Use configure and set either the RIPVersion keyword or the OSPFEnabled keyword in the IP WAN 0 and or any other port numbers you wish to configure section Add static routes and a default router using the edit config IP Static command Note Due to the complexity of BGP configuration parameters for BGP are not given in this Quickstart For help with BGP configuration parameters and other configuration questions refer to the Tech Support pages on the Compatible Systems Web site at http www compatible com Chapter 2 Quickstart Instructions 10 IPX Protocol Required for IPX Frame Relay operation requires that the WAN interface be set as a numbered interface This means that the interface and thus the Frame Relay network must have an IPX network number IPX numbered interface IPX network number CV Use the IPX Routing WAN Dialog Box TB Use configure and set the Numbered and Net keywords in the IPX WAN 0 and or any oth
17. o an ISP via Frame Relay check with your ISP technical staff on whether or not you must manually enter DLCI information CV Use the DLCI Mapping Database under WAN Link Configuration DLCI button TB Use configure and set the DLCI keyword in the Frame Relay WAN 0 and or any other port numbers you wish to configure section IP Protocol Chapter 2 Quickstart Instructions 9 There are two ways to set up Frame Relay One is to set the WAN interface as a numbered interface This means that the interface and thus the Frame Relay network will have an IP address subnet mask etc The other is to set it as an unnumbered interface and specify that the link is point to point Frame Relay and set the local DLCI Unnumbered Frame Relay can only be configured using text based configuration Instructions are provided for both options Required for IP Numbered Interface IP numbered interface e IP address e JP subnet mask e IP broadcast address CV Use the TCP IP Routing WAN Dialog Box TB Use the configure command and the Numbered IPAddress SubnetMask and IPBroadcast keywords in the IP WAN 0 and or any other port numbers you wish to configure section Required for IP Unnumbered Interface JP unnumbered interface e Point to Point Frame Relay e Local DLCI TB Use the configure command and the Numbered PointToPointFrame and Inter faceDLCI keywords in the IP WAN 0 and or any other port numbers you wish to configure sectio
18. ort numbers you wish to configure section Use configure and set the Enabled Area and Node keywords in the DECnet Global section Note Setting DECnet on for any port with the command line also sets DECnet on globally In CompatiView you must set a global parameter and a port specific parameter Suggested for DECnet Setting the parameters above should be adequate for most installations WAN Interface Configuration The default setting for all WAN interfaces on your Octal V 35 Quad 10 100 RIOP is Off for all protocols and for the link configuration In order to use a WAN interface you must first set some physical parameters and then set up the link and protocol parameters Physical Communications Settings You may need to set the baud rate or other physical communications parameters for the WAN interface These parameters will depend on the line communications device you are using CV Use the Physical Configuration WAN Dialog Box TB Use configure and the V 35 Interface WAN 0 and or any other port numbers you wish to configure section PPP Configuration This section covers the settings required for PPP point to point protocol operation of the V 35 WAN interfaces WAN Link Configuration Required for Dedicated Leased Line Operation Dedicated line operation is the simplest to set up e Set Dedicated connection e Set PPP connection CV Use the Link Configuration WAN Dialog Box TB Use configure and then set the Mo
19. ou wish to configure section Saving a Configuration File to Flash ROM Once a configuration is complete you can save it to the router s Flash ROM Until saved all changes are made in a separate buffer and the actual router interfaces continue to run as before the changes were made CV Use the Save to Device option from the File menu TB Use the save command Chapter 3 Shipping Defaults Chapter 3 Shipping Defaults Ethernet Interfaces IP Routing Defaults e Off all interfaces IP Bridging Defaults e On all interfaces e Address 198 41 12 1 e Subnet Mask 255 255 255 0 e Broadcast Address 198 41 12 255 IPRIP off IPX Routing Defaults e 802 3 on autoseeding all interfaces e 802 2 on autoseeding all interfaces e Type II on nonseeding e 802 2 SNAP on nonseeding IPX Bridging Defaults e Off all interfaces AppleTalk Routing Defaults e Phase I off all interfaces e Phase II on autoseeding all interfaces AppleTalk Bridging Defaults e Off all interfaces DECnet Defaults e Off all interfaces WAN Interfaces e Off 12 Chapter 4 LED Patterns 13 Chapter 4 LED Patterns Some of the LEDs on the front of the VSR multigigabit switching router serve dual functions In addition to indicating certain router wide operating conditions they may also display port specific information Note Any continuous flashing pattern not noted in this chapter may be caused by a hard ware failure Please call Compatibl
20. rnet Suggested for IPX You may want to set your own network numbers rather than using the autoconfigured values You may also want to turn off unused frame types CV Use the IPX Routing Ethernet Dialog Box TB Use configure and set keywords in the IPX Ethernet 0 and or any other port numbers you wish to configure section AppleTalk Protocol Required for AppleTalk Generally there are no required changes from the shipping Ethernet configuration for Apple Talk The Ethernet interface will autoconfigure to use AppleTalk Phase 2 and will adapt to conditions on the Ethernet Suggested for AppleTalk You may want to set your own network numbers rather than using the autoconfigured values You may also want to use more meaningful zone names CV Use the AppleTalk Routing Ethernet Dialog Box TB Use configure and set keywords in the AppleTalk Phase 2 Ethernet 0 and or any other port numbers you wish to configure section Chapter 2 Quickstart Instructions 6 DECnet Protocol Required for DECnet The router s shipping configuration does not have DECnet turned on In order to be used DECnet must be turned on both globally and for a particular port e Set DECnet on globally and for this port e Set DECnet area e Set DECnet node CV Use the DECnet Routing Dialog Box under Global DECnet Routing and the DECnet Ethernet Dialog Box TB Use configure and set the Mode keyword in the DECnet Ethernet 0 and or any other p
21. tor on the chassis of the V 35 line communications device The pin outs for this cable are shown in Appendix A Note Please use only the supplied cables when connecting your V 35 line communication device to the Octal V 35 Quad 10 100 RIOP s interfaces The cables provided with other equipment will generally not have the same internal connections Connecting a Line Device to the V 35 Interfaces These interfaces can be used to connect to a wide variety of line communications devices including those which support either leased or dialed operation Examples include leased 56K CSU DSU s switched 56K CSU DSU s fractional T1 CSU DSU s ISDN terminal adapters and full T1 El rate CSU DSU s Make sure that both units are powered off First connect one of the eight V 35 adapter cables to the line communications device Then connect one of the Quad cables to one of the V 35 inter faces on the front of the router Lastly connect the two cable ends together With each connec tion make sure to fasten the captive screws into the jack screws on either side of the connec tors Connecting a Management Console If you wish to connect an out of band management console use the supplied DB 25 male to DB 25 female console cable and connect to the Console interface on the Octal V 35 Quad 10 100 RIOP You can use a dumb terminal or a computer equipped with VT 100 terminal emulation The default settings for the Console interface are VT 100 termina