1. will perform three message tests so this sequence will occur three times If the System Access Module has errors during the process the test could take up to 15 minutes 92 If the Red LED is lit solid then the System Access Module failed to send the message Try a new mounting location for the System Access Module If the Yellow LED is lit solid then the System Access Module sent its message but did not receive a reply The Bryant server may be down or the received signal is weak Try a new mounting location for the System Access Module Aborting Test There is no method to abort a radio test once it is started other than to remove power The LEDs will maintain their state for 1 hour after the test Pressing the Radio Test button momentarily will clear the LEDs Pressing the Radio Test button again for five seconds will repeat the radio test See Fig 2 for a description of the radio test and LED sequence INSTALL COMPONENTS INSTALL SYSTEM ACCESS MODULE Once the radio test has passed the System Access Module can be permanently installed The System Access Module is designed so that wires can enter it from behind above or below Plan wire routing before mounting 1 Remove cover to access mounting holes 2 Mount back plate to wall using screws and wall anchors provided 3 Level back plate and tighten screws CONNECT EVOLUTION SYSTEMS CAUTION UNIT OPERATION HAZARD Failure to follow this caution may res
2. connector 1 to connector 2 or vice versa or Evolution equipment has changed the System Access Module must update Bryant s servers with the new information This will happen automatically within one hour or can be manually forced with the process described above TROUBLESHOOTING FAULT INDICATORS Under normal operation the Yellow and Green LED will be on continuously solid If the System Access Module does not receive communications with the Evolu tion system the Green LED will not be on If there are faults present the Yellow LED indicator will blink a two digit status code The first digit will blink at a fast rate the second at a slow rate STATUS CODE DESCRIPTION 45 Board Failure 61 Radio out of range no coverage for five minutes 62 Loss of communication with the radio 63 Radio not registered with the local network unregistered for five minutes 64 Auxiliary sensor active 1 short Flash Yellow at 1Hz Flash Yellow at 1Hz and solid Red Wait for Reply Flash Green and Yellow short at 1 Hz Flash Green and Yellow at 1Hz and solid Red Send Message 2 Flash Yellow 2 times short 1 second off gt Flash Yellow 2 times and solid Red Flash Green and Yellow Wait for Reply 2 times long Flash Green and Yellow 2 times and solid Red Send Message 2 Flash Yellow 3 times long 1 second off Flash Yellow 3 times a
3. DER ATIONS WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury death or possible equipment damage Disconnect supply power before routing wire NOTE All wiring must comply with national state and local codes LOCATING SYSTEM ACCESS MODULE Since the System Access Module SAM uses two way radio choose a potential mounting location that is as high and as close to outside walls or windows as possible to attempt to maximize radio coverage The coverage is dependent on where the Skytel trans ceivers are located If one location does not work try the opposite side to get the device in closer directional proximity Temporarily mount the System Access module in the intended permanent mounting location until the radio test has passed 100 The System Access Module is approved for indoor use only and should never be installed with any of its components exposed to the elements The System Access Module may be installed in any area where the temperature remains between 4 and 158 F and there is no condensation The cover must be installed to prevent damage from other sources Do not locate where it will be accessible to children The SAM should be mounted in the vertical position Remember that wiring access and Skytel reception are the most important considerations Select a location near the Evolution furnace or fan coil where wiring from the User Interface each Remote Room Sensor o
4. Installation and Start Up Instructions EVOLUTION SYSTEM ACCESS MODULE Evolution System Access Module SYSTMBBSAM01 A97038 NOTE Read the entire instruction manual before starting the installation This symbol indicates a change since the last issue TABLE OF CONTENTS SAFETY CONSIDERATIONS ei 1 INSTALLATION CONSIDERATIONS eel INTRODUCTION 1 INSTALLATION 1 3 Check Equipment and Job will Component Location and Wiring Considerations Connect Power Source R dio Test RS 232 COMME CON 3 Updating System Profile scscsacdscsiccssssciscesersespasssorseacesbeonstneseds 3 Troubleshooting 3 SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause fire electrical shock or other conditions that may cause personal injury or property damage Consult a qualified installer service agency or your distributor or branch for infor mation or assistance The qualified installer or agency must use factory authorized kits or accessories when modifying this product Refer to the individual instructions packaged with the kits or accessories when installing Follo
5. nd solid Red Wait for Reply Glash Green and Yellow long 3 times Glash Green and Yellow 3 times and solid Red Solid Green LED Yellow and Red off Green Green Green Green Green Green Green Green Green Green Green Green Green Yellow Yellow Yellow Yellow Yellow Yellow x Yellow Yellow x Yellow x Yellow x Yellow Yellow x Yellow Red Red Red Red Red Red Red Red Red Red Red Red Red Fig 2 Radio Test Process and LED Sequence A05073 AUXILIARY SENSOR lt ABC TO SYSTEM 1 ABC TO SYSTEM 2 p 59 S Oe QO 8 RADIOTEST STATUS COMM1 COMM2 PIN LABEL O 4 Antenna Automation Connection RS 232 SERIAL NUMBER 200 OO 24VAC 24VAC Fig 3 System Access Module Control Board 5 A04224 2006 Bryant Heating amp Cooling Systems 7310 W Morris St Indianapolis IN 46231 6 Printed in U S A IISAMO101si Catalog No Il 1 0 1
6. r Smart Sensor each damper actuator and the equipment itself can come together easily CAUTION ELECTRICAL OPERATION HAZARD Failure to follow this caution may result in equipment A damage or improper operation To prevent possible damage to the System Access Mod ule do not mount on plenum duct work or flush against furnace WIRING CONSIDERATIONS Ordinary thermostat wire is ideal when wiring the System Access Module shielded cable is not necessary Use 22 AWG or larger for normal wiring Lengths over 100 ft should use 20 AWG or larger wire CONNECT POWER SOURCE AND ANTENNA Screw the antenna to the radio connector See Fig 3 for antenna attachment location A separate 24 VAC transformer is included to power the System Access Module DO NOT connect the D wire 24 VAC hot from the Evolution system The transformer is heavy Make sure it is secured to the power outlet with an appropriate screw through the boss on the trans former IV RADIO TEST The purpose of this test is to verify effective 2 way communica tions at the installation site The test must pass 100 before the installation of the SAM can continue Press and hold the RADIO TEST button for at least 5 seconds A flashing Yellow LED will indicate the test is in progress A flashing Yellow and Green LED means the transmission is complete and the System Access Module is waiting for a reply A constant Green LED means the radio test has passed The radio
7. rface indicating the auxiliary sensor is active The home owner will also be notified via e mail and or phone if so chosen on the internet web interface Vill SYSTEM START UP After a successful radio test has occurred power may be applied to the Evolution System s The user interface of the Evolution System will automatically find the System Access Module at power System installation screens will automatically appear and will display the Equipment Summary screen when finished The Equipment Summary screen will display REMOTE ACCESS near the bottom of the screen If REMOTE ACCESS is not displayed check connections to the ABC wires as well as ensure the Yellow LED is lit on the System Access Module this ensures the module has power The green LED will be lit next to each ABC connection if the user interface has established communication IX PIN NUMBER AND SERIAL NUMBER The PIN and Serial number of the System Access Module are used by the system owner to register their system with Bryant Remove the sticker containing the PIN number from the radio and install at the front of the Owner s Guide Also write down the SAM serial number in the Home Owner s Guide The serial number can be found on the SAM packaging at the bottom of the large SAM circuit board see Fig 3 or in the user interface Service Menu If PIN number is lost or missing it can be found by entering the Service Menu of the User Interface 10 second press of
8. the Advance button and looking at the Model Serial Numbers screen The PIN will be listed with the System Access Module model and serial numbers RS 232 Connector An RS 232 port has been provided for connection to home automation equipment Consult your home automation supplier for support Updating System Profile The Evolution System will automatically send system information to Bryant s computer servers within one hour after the system has been successfully installed Access to the system via the internet or telephone will not be available until this occurs The system can be forced to send its information through the following process if internet and telephone access is required immediately Press and hold the RADIO TEST button for 15 seconds When the button is first pressed the red LED will turn on Five seconds into the press the yellow LED will turn on 15 seconds into the press the green LED will turn on Release the button when the green LED turns on The red LED will flash when messages are being sent The red and yellow LED will flash when the SAM is waiting for message replies Upon successful profiling both green LEDs will be lit If profiling is not successful the red LED will be lit solid The entire profiling process can take up to 15 minutes per Evolution System If two systems are connected to one SAM then the profiling process can take up to 30 minutes If the Evolution system ABC wiring is moved from
9. ult in improper unit operation Improper wiring of the ABC connector will cause the System Access Module to operate improperly Check to make sure all wiring is correct before proceeding with installation or turning on power Connect the A B and C wires from the Evolution System to terminals labeled B1 and C1 Connect the second Evolution System if present to the terminals labeled A2 B2 and C2 ABC bus wiring only requires a three wire connection however it is good practice to run thermostat cable greater than three wires in the event of a damaged or broken wire during the installation It is recommended that the following color code be used when wiring each ABC connector A Green Data A B Yellow Data B White 24VAC Com NOTE The D wire red 24 VAC hot from the Evolution system is not connected to the System Access Module It is not mandatory that the above color code be used but each ABC connector in the system MUST be wired consistently CONNECT AUXILIARY SENSOR OPTIONAL The System Access Module will support a dry contact sensor for use with water detection or some other use as seen fit Connect one side of the contacts to connector AUXC common and the other side to connector AUX input The sensor input can provide up to 20mA at 5 volts d c If the sensor input is active it will not shut down or affect operation of the HVAC system s A pop up message will appear on the user inte
10. visions must be made to secure the transformer to the outlet The D wire 24 VAC from the Evolution system MUST NOT be used to power the System Access Module Use this instruction to guide the actual installation process after the Evolution system s have been installed One System Access Module is capable of handling two Evolution systems INTRODUCTION An Evolution System Access Module allows remote connectivity for up to two Evolution systems within the same building The Evolution system owner as well as authorized dealer can monitor and control the system via the internet as well as by telephone The System Access Module communicates through a two way radio via the Skytel paging network Please visit http www skytel com coverage telemetry_coverage htm to check coverage for the installation site The coverage must be listed as Full Service for the System Access Module to function properly Please note that Skytel is continuously expanding their service area so coverage may not be indicated by the web site The System Access Module can also monitor a dry contact sensor to provide a warning for the presence of water in the building or some other use If the sensor is active the Evolution system will not be disabled or shut down INSTALLATION CHECK EQUIPMENT AND JOB SITE INSPECT EQUIPMENT File claim with shipping company prior to installation if shipment is damaged or incomplete COMPONENT LOCATION AND WIRING CONSI
11. w all safety codes and wear safety glasses Have fire extinguisher available Read these in structions thoroughly and follow all warnings or cautions attached to the unit Consult local and state building codes and Sheet Metal and Air Conditioning National Association SMACNA for special installation requirements 1 NEW 1 0 1 05 05 Cancels This is the safety alert symbol When you see this symbol the equipment and in the instruction manual be alert to the potential for personal injury Understand the signal words DAN GER WARNING and CAUTION These words are used with the safety alert symbol DANGER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies a hazard which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE is used to highlight suggestions which will result in enhanced installation reliability or operation INSTALLATION CONSIDERATIONS Before the actual installation of a System Access Module can begin determine the mounting location A radio test must be performed with the System Access Module in the intended mounting location See below on how to perform a radio test The System Access Module is powered with a 24 VAC transformer included A 120VAC supply must be near the mounting location of the System Access Module Pro

Download Pdf Manuals

image

Related Search

Related Contents

27AF44 - Audio Lab of Ga  Métropole à vélo : roulez malin ! plein de bon sens, simple et efficace !  dreamGEAR ISOUND-4720 mobile device charger  schema centralina mk33f  Lightolier C6P38A User's Manual  Oferta de Referência de Realuguer da Linha de Assinante  1 Pince multimètre Clamp multimeter Vielfachmesszange Pinza  Descarga aquí  