Home
Bosch Appliances Security Camera LTC 9384 User's Manual
Contents
1. 5 9 2 1 Position the housing vertically and replace Cradle Assembly the cradle assembly by applying pressure onto the rear cap until the end of the cradle is approximately flush with the back of the housing see FIGURE 16 FIGURE 16 Inserting the Cradle Assembly CAUTION If a pull seal is installed in the YN breather hole be careful not to pinch the head of the pull seal Damage to the pull seal may allow water to enter the housing causing damage to the camera and lens 2 Tighten the retention screw making sure it is seated into the rear cap groove If the housing needs to be tamper resistant the LTC 9380 02 purchased separately should be installed at this time 3 Attach the housing to the appropriate mount or pan tilt per the instructions provided According to the orientation of the housing the cradle assembly may need to be rotated To rotate the cradle assembly while mounted grasp the rear handle and rotate it to the desired position View the monitor while rotating Bosch Security Systems September 1 2004 LTC 9384 Series Instruction Manual Exploded View EN 14 6 EXPLODED VIEW FIGURE 17 7 PARTS LIST HARDWARE KIT Ref Part Part Hardware Kit 315 1514 005 an Quantity Part Description No Number Qty Description y 3 Cable Tie Heyco Fitting Kit 315 3802 001 2 BHCS 4 20 x Yin 7 2 NPT 1 BHCS 4 20 x Zin 8 1 NPT 1 BHCS 14 20 x
2. 2004 LTC 9384 Series Instruction Manual Contents EN 6 Table of Contents Important Safeguards ns vase rl ceeded Ee Ee dow ea eed ged EERSTEN a lg a 2 1 UNPACKING oi A sti 6 EE 7 2 SERVICE cd Oan eee Samal ete aes 7 3 CARE AND MAINTENANCE ISE erder a ee Wa E 7 4 DESCRIPTION sar na cs tile natens Se eee pete le did sds 7 4 1 Em Closer Rating ereen cesar dts ace fara da deeg a RAN RN dee de A eg H 5 INSTALLATION sucatas ENEE ENNEN EE a R E E E 7 5 1 Model Designation ve never verwennen ernst it Ae 7 52 Tools Required crio dee ENE NEE de eeh ENER a Ed a ENER Ae 8 33 Cable Requirements oi vaa nerven nnn Caden AEN owls ta Shean ie aus deena 8 5A Cradle Removal aar ane ee ace EE De a ER OS ee ee EC d de Wer Bae he ol 8 5 5 Camera Lens Installation sa rna te itn a ai ee adat 9 5 6 Camera Lense Wiring sneue bird wesc he EE ee ok ee EEN ANAE E E gob e 9 57 Video Coax Connection as rs eraann dan Se ee eee RER en ee ee ee 12 oo Lens Wining os eae nee ee eater ud ae gb SET E og e ted oa dest e 12 EE Final AssemDly EE 12 6 EXPLODED VIEW ini E AE E EE A EE 14 7 PARTS LIST iia A EEN ENEE Cadena eee ter ae dt dd 14 Bosch Security Systems September 1 2004 LTC 9384 Series Instruction Manual Unpacking 1 UNPACKING This electronic equipment should be unpacked and handled carefully Check for the following items Verify the unit model number Verify that parts listed as follows have be
3. DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED parts that could result in a fire or electrical shock Never spill liquid of any kind on the unit 3 Power Cord and Power Cord Protection For units intended to operate with 230VAC 50Hz the input and output power cord must comply with the latest versions of IEC Publication 227 or IEC Publication 245 Power supply cords should be routed so they are not likely to be walked on or pinched Pay particular attention to location of cords and plugs convenience receptacles and the point of exit from the appliance 4 Overloading Do not overload outlets and extension cords this can result in a risk of fire or electrical shock For Outdoor Product Power Lines An outdoor system should not be located in the vicinity of overhead power lines electric lights or power circuits or where it may contact such power lines or circuits When installing an outdoor system extreme care should be taken to keep from touching power lines or circuits as this contact might be fatal U S A models only refer to the National Electrical Code Article 820 regarding installation of CATV systems For Rack mount Product 1 Ventilation This unit should not be placed in a built in installation or rack unless proper ventilation is provided or the manufacturer s instructions have been adhered to The equipment must not exceed its maximum opera
4. Input on 24VAC models Operation above 30VAC violates low voltage operation Class 2 Specifications Normal operation is 24VAC Bosch Security Systems September 1 2004 LTC 9384 Series Instruction Manual Installation Maximum Camera Lens Size LTC 9384 xx Accepts cameras up to 64W x 54H mm 2 5 x 2 lin lenses up to 67W x 75H mm 2 6 x 2 9in and camera lens combinations up to 292mm 11 5in LTC 9384 20NT Accepts cameras up to 64W x 54H mm 2 5 x 2 lin lenses up to 67W x 75H mm 2 6 x 2 9in and camera lens combinations up to 355mm 14 0in 5 2 Tools Required Flat blade screwdriver e Phillips head screwdriver e 5 32in or 4mm hex wrench e 5 16in or 8mm hex wrench e Adjustable wrench e Wire cutter stripper crimper tool 5 3 Cable Requirements Video Transmission Coaxial Cable Type RG 59 U Runs lt 1000ft RG 11 U Runs lt 2000ft Cable Size Outside diameter between 4 6mm 0 181in and 7 9mm 0 312 in Shield 2 93 Braided Copper Shield DC Resistance gt 150 1000ft RG 59 U gt 60 1000ft RG 11 U Temperature Rating gt 80 C 176 F Sources Belden 9259 Belden 9238 Input Power Cord North American Cable Type SJTOW A Rated Cable Size Outside diameter between 4 3mm 0 170in and 11 9mm 0 470in Conductors 3 conductor version and 2 conductor version Agency Rating UL C S A UL VW 1 Temperature Rating 105 C 221 F 300 V Belden 19506 Belden 19509 Nor
5. in Cradle Assembly Kit 315 3803 001 1 BHCS 4 20 x Zin 11 1 Cradle Heater Assembly 1 BHCS 4 20 x in 9 1 Ring Tongue Terminal 1 BHOS 20 x 1 in 13 1 Ground Slide 2 0 4mm 0 016in Plastic Spacer 10 1 M4 Phillips Head Screw 1 1 65mm 0 065in Plastic Spacer 12 1 XXX Phillips Head Screw 1 3 9mm 0 154 in Plastic Spacer 2 1 Pull Seal 1 7 4mm 0 292in Plastic Spacer 115 VAC Prewired Transformer Kit 315 3804 001 1 9 8mm 0 385in Plastic Spacer 3 315 3808 001 1 115VAC Prewired Transformer 1 in NPT Plug 15 2 Rivet sin 2 Pull Seals 6 1 Transformer Insulator 24 VAC Prewired Transformer Kit 315 3805 001 3 315 3809 001 1 24VAC Prewired Transformer 15 2 Rivet sin 6 1 Transformer Insulator 230 VAC Prewired Transformer Kit 315 3806 001 3 315 3810 001 1 230VAC Prewired Transformer 15 2 Rivet sin 6 1 Transformer Insulator Housing Kit 315 3807 001 11 1 Housing 1 2 Silicone O ring Bosch Security Systems September 1 2004 LTC 9384 Series Instruction Manual EN 15 Bosch Security Systems September 1 2004 Bosch Security Systems Inc Bosch Security Systems B V Bosch Security Systems Pte Ltd 850 Greenfield Road P O Box 80002 38C Jalan Pemimpin Lancaster PA 17601 USA 5600 JB Eindhoven Singapore 577180 Tel 800 326 3270 The Netherlands Republic of Singapore Fax 1 717 735 6560 Tele 31 40 27 80000 Tel 65 6 319 3486 www boschsecuritysystems com 2004 Bosch Security Sys
6. to insert the plug fully into the outlet try reversing the plug If the plug still fails to fit contact an electrician to arrange replacement of the obsolete outlet Do not defeat the safety purpose of the polarized plug Alternately this unit may be equipped with a 3 wire grounding plug a plug with a third pin for grounding This safety feature allows the plug to fit into a grounding power outlet only If unable to insert the plug into the outlet contact an electrician to arrange replacement of the obsolete outlet Do not defeat the safety purpose of the grounding plug Lightning For added protection during a lightning storm or when this unit is left unattended and unused for long periods of time unplug the unit from the wall outlet and disconnect the cable system This will prevent damage to the unit due to lightning and power line surges Bosch Security Systems September 1 2004 LTC 9384 Instruction Manual Safety Precautions EN 3 For Indoor Product 1 Water and Moisture Do not use this unit near water for example in a wet basement in an unprotected outdoor installation or in any area classified as a wet location 2 Object and Liquid Entry Never push objects of Safety Precautions CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF any kind into this unit through openings as they may touch dangerous voltage points or short out ELECTRIC SHOCK
7. uitschakelaar aan staat Het netsnoer is de hoofdschakelaar voor alle apparatuur D G GO Bosch Security Systems September 1 2004 LTC 9384 Instruction Manual Safety Precautions Medidas de Seguranca EN 5 Sicurezza CUIDADO RISCO DE CHOQUE ELECTRICO NAO ABRIR EI PERICOLO DI SCOSSA ELETTRICA NON APRIRE CUIDADO PARA REDUZIR O RISCO DE CHOQUE EL CTRICO N O RETIRE A TAMPA OU A PARTE POSTERIOR NO INTERIOR N O EXISTEM PE AS QUE POSSAM SER REPARADAS PELO UTILIZADOR REMETA A ASSIST NCIA PARA OS T CNICOS QUALIFICADOS Este s mbolo indica a presen a de tens o perigosa n o isolada dentro da estrutura do produto o que pode constituir risco de choque el ctrico O utilizador deve consultar as instru es de funcionamento e manuten o assist ncia nos documentos que acompanham o aparelho Aten o a instala o deve ser executada apenas por t cnicos qualificados da assist ncia de acordo com o c digo el ctrico nacional ou os c digos locais aplic veis Corte de corrente As unidades com ou sem interruptores ON OFF ligar desligar recebem corrente sempre que o fio de alimenta o est introduzido na fonte de alimenta o contudo a unidade apenas est operacional quando o interruptor ON OFF est na posi o ON O fio de alimenta o destina se a desligar a corrente em todas as unidades El G G EA ZEN SES JERSIE PE
8. 00 can be purchased separately Use of drip loops is recommended on the DN outside of the rear endcap 5 6 2 Plug Insertion If no lens control or feed through wiring will be used remove the preinstalled 3 8in liquid tight fitting from the small bottom center hole and install the 3 8in NPT plug provided Use a 8mm 5 16in hex wrench to tighten Failure to do so will allow water to enter and cause damage to all electronic parts see FIGURE 4 3 8in NPT Plug FIGURE 4 3 8in NPT Plug Insertion Bosch Security Systems September 1 2004 LTC 9384 Series Instruction Manual Installation EN 10 5 6 3 Power Connections to do so will allow water to enter and damage The LTC 9384 Series Housings except the all electronic parts Use a tie wrap included to nontransformer LTC 9384 20NT version allow the provide strain relief on the power cord at the use of 24VAC cameras regardless of the supply exit point inside the unit voltage to the housing This is achieved via transformer in the housing The transformer s primary Securely tighten all fittings to ensure a liquid supply power varies depending on the model of AB seal Failure to do so could allow water to housing see Section 5 1 Model Designation In the enter the housing and damage the camera and 115 volt and 230 volt models the transformer also lens supplies 24VAC power to the integral window heater defogger Select the appropriate wiring instructions fro
9. 3 16in 5mm clearance from the front face of the lens to the front faceplate of the cradle during the camera lens assembly This clearance provides the necessary space for the lens to extend outward when zooming Secure both the camera and the lens to the cradle with the 1 4 20 BHCS and appropriate plastic spacer 5 6 Camera Lens Wiring WARNING Use only the cables specified under INSTALLATION Cable Requirements for wiring of all cameras and lenses General 5 6 1 1 The dual male threaded portion of the three 3 liquid tight fittings two 2 NPT 12in and one 1 NPT 3 8in located in the rear of the cradle are preinstalled to a specified torque to prevent entrance of water Do not remove or loosen these parts The two large fittings are supplied with seal glands for cables with diameters from 4 3mm to 11 9mm 0 17in to 0 47in The small fitting will accept cables with diameters from 4 6mm to 7 9mm 0 18lin to 0 312in see FIGURE 3 EN 9 Securely tighten all fittings to ensure a liquid tight seal Failure to do so could allow water to enter the housing and damage the camera and lens Seal Cap Seal Gland Dual Male Portion FIGURE 3 Liquid Tight Fitting Assembly If a sealant is to be used be sure it is a neutral cure type Sealants that release acetic acid may harm camera electronics If it is necessary to use a PG type conduit an NPT to PG Conversion Kit LTC 9381
10. LTC 9384 Series Security Systems Instruction Manual EN Outdoor Camera Housings BOSCH LTC 9384 Instruction Manual Important Safeguards Important Safeguards 1 Read Follow and Retain Instructions All safety 10 and operating instructions should be read and followed before operating the unit Retain instructions for future reference Heed Warnings Adhere to all warnings on the unit and in the operating instructions Attachments Attachments not recommended by the product manufacturer should not be used as they may cause hazards Installation Cautions Do not place this unit on an unstable stand tripod bracket or mount The unit may fall causing serious injury to a person and serious damage to the unit Use only manufacturer recommended accessories or those sold with the product Mount the unit per the manufacturer s instructions Appliance and cart combination should be moved with care Quick stops excessive force or uneven surfaces may cause the appliance and cart combination to overturn Cleaning Unplug the unit from the outlet before cleaning Follow any instructions provided with the unit Generally using a damp cloth for cleaning is 11 sufficient Do not use liquid cleaners or aerosol cleaners Servicing Do not attempt to service this unit yourself Opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified se
11. RA RE SI FPPHEBSCSAH MF AX CEM EMS LOPES Zea cin OLSEN EEA RA f BE o RARE SRL EE FEL TARA A MEA o MAI FERIR A IRE HERA A OC AAE IEA CIE RREE KX ON OFF FAMA MRE NATE ON OFF FF ON fr ERA GELGE SIF HARE HIRAM EB AK ATTENZIONE PER RIDURRE IL RISCHIO DI SCOSSE ELETTRICHE NON RIMUOVERE LA COPERTURA O IL PANNELLO POSTERIORE L UNIT NON CONTIENE COMPONENTI INTERNI RIPARABILI DALL UTENTE PER QUALSIASI INTERVENTO RIVOLGERSI A PERSONALE TECNICO QUALIFICATO Questo simbolo indica la presenza di tensione pericolosa non isolata all interno del contenitore del prodotto Ci comporta un potenziale rischio di scosse elettriche Si consiglia di consultare le istruzioni operative e di manutenzione interventi tecnici contenute nella documentazione fornita con il dispositivo Attenzione l installazione deve essere effettuata esclusivamente da personale tecnico qualificato in conformit con il National Electrical Code o con le normative locali vigenti Scollegamento dell alimentazione Le unit dotate o sprovviste di interruttori ON OFF vengono alimentate quando si inserisce il cavo nella presa dell alimentazione L unit tuttavia in funzione solo quando l interruttore ON OFF si trova nella posizione ON Il cavo di alimentazione costituisce il dispositivo di scollegamento dell alimentazione principale per tutte le unit D G CE Bosch Security Systems September 1
12. Volt Camera Bosch Security Systems September 1 2004 230 VAC Input LTC 9384 Series Instruction Manual Installation For 24 Volt Cameras 1 Installing a 24 volt camera into the LTC 9384 50 housing uses the internal transformer for camera power see FIGURE 11 2 Connect the supply 230VAC to the terminal block Use only the terminal block provided for this connection 3 Connect the secondary flying leads to the camera s 24 volt input Refer to the wiring diagram for clarification To Heater Defogger 12 White Black Striped 24VAC To Camera White Black 7 Striped To Heater Defogger FIGURE 11 LTC 9384 50 Transformer Wired for 24 Volt Camera Video Coax Connection WARNING Use only the cables specified under INSTALLATION Cable Requirements for video coax wiring connection 5 7 If no lens control or feed through wires will be used 1 Install the seal cap portion of the large liquid tight fitting on the video coax cable and pull the cable through the right hand fitting on the rear of the cradle If lens control is used pull the cable through the small bottom fitting 2 Attach the BNC connector to the coax and connect it to the camera Pull any excess wire out of the cradle assembly and tighten approximately 1 to 11 2 turns past the point where the fitting starts to grip the wire Failure to do so will result in water damage to all electronic part
13. a Dit symbool geeft aan dat er binnen in het apparaat ongeisoleerde gevaarlijke spanning aanwezig is die mogelijk elektrische schokken kan veroorzaken El usuario debe consultar las instrucciones de funcionamiento y mantenimiento reparaci n en la documentaci n que se suministra con el aparato Atenci n la instalaci n la debe realizar nicamente personal cualificado de conformidad con el National Electric Code o las normas aplicables en su pa s Desconexi n de la alimentaci n Las unidades con o sin interruptores de encendido apagado reciben alimentaci n el ctrica siempre que el cable de alimentaci n est conectado a la fuente de alimentaci n Sin embargo la unidad s lo funciona Ea La A EA cuando el interruptor est en la posici n de encendido El cable de alimentaci n es la principal fuente de desconexi n de todas las unidades De gebruiker dient de bedienings en onderhoudsvoorschriften te raadplegen in de documentatie die werd meegeleverd met het apparaat Attentie het apparaat mag alleen door gekwalificeerd personeel worden geinstalleerd De installatie dient in overeenstemming met de nationale elektrische richtlijnen of de van toepassing zijnde lokale richtlijnen te worden uitgevoerd Spanning uitschakelen Apparatuur met of zonder aan uitschakelaar staat onder spanning zolang de stekker is aangesloten op de wandcontactdoos De apparatuur is uitsluitend in werking als de aan
14. en included See INSTALLATION Hardware Kit Quantity Part Description Cable Tie BHCS 14 20 x 1 4in BHCS 14 20 x 5 8in BHCS 14 20 x 3 4in BHCS 14 20 x 12in BHCS 14 20 x 3 8in BHCS 14 20 x 11 4in 0 4mm 0 016in Plastic Spacer 1 65mm 0 065in Plastic Spacer 3 9mm 0 154in Plastic Spacer 74mm 0 292in Plastic Spacer 9 8mm 0 385in Plastic Spacer 3 8in NPT Plug Pull Seals NO hh ba ba ba Nk ba ha ba ba NO D If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper If any items are missing notify your Bosch Security Systems Inc Sales Representative or Customer Service The shipping carton is the safest container in which the unit may be transported Save it for possible future use 2 SERVICE If the unit ever needs repair service the customer should contact the nearest Bosch Security Systems Inc Service Center for return authorization and shipping instructions Service Centers USA Phone 800 366 2283 or 717 735 6638 fax 800 366 1329 or 717 735 6639 CCTV Spare Parts Phone 800 894 5215 or 408 956 3853 or 3854 fax 408 957 3198 e mail BoschCCTVparts ca slr com Canada Phone 514 738 2434 Europe Middle East amp Asia Pacific Region Phone 32 1 440 0711 For additional information see www boschsecuritysystems com EN 7 3 CARE AND MAINTENANCE Clean the viewing window as needed with a mild nonabrasive det
15. endcap is pointed upward To maintain enclosure protection ratings of NEMA 6P and IP68 the pull seal provided in the hardware kit must be installed in the front endcap Install the pull seal in a cool dry environment to prevent trapping moisture inside the housing see FIGURE 12 NOTE Pull seal installation allows the housing s front endcap to be pointed upward Bosch Security Systems September 1 2004 LTC 9384 Series Instruction Manual Installation Front Face Breather Hole FIGURE 12 Breather Hole Proper installation of the pull seal is as follows 1 Remove the cradle assembly from the housing 2 Obtain a rubber pull seal Part Number 315 2569 001 from the hardware kit see FIGURE 13 An extra pull seal is also provided ZE Long End FIGURE 13 Pull Seal 3 Insert the long end of the pull seal into the breather hole starting from the front of the endcap see FIGURE 14 Front of ndcap Cradle E A N Pull Seal 2 Breather Hole FIGURE 14 Inserting the Pull Seal 4 Grip the pull seal s long end from the back of the front endcap Steadily pull the long end until the head of the pull seal is flat against the front of the endcap see FIGURE 15 NOTE The pull seal s long end will stretch when pulled through the breather hole EN 13 Front Endcap Rear Face of Head Should Be Flush with Front Face Grip and Pull of Front Endcap FIGURE 15 Installing the Pull Seal
16. ergent in water and a soft cloth 4 DESCRIPTION The LTC 9384 Series of environmental housings are attractive aluminum enclosures designed for outdoor CCD camera installations 4 1 Enclosure Rating 41 1 NEMA 3R and IP54 The LTC 9384 Series Housings include a breather hole in the front face cap The breather hole prevents the accumulation of moisture inside the housing when installed in areas of high humidity With the breather hole open the LTC 9384 Series Housings meet the enclosure rating requirements of NEMA 3R and IP54 41 2 NEMA 4 and IP65 For installations requiring an enclosure rating of NEMA 6P or IP68 the breather hole must be plugged using the pull seal Part No 315 2569 001 provided in the hardware kit Refer to Final Assembly under INSTALLATION for proper installation 5 INSTALLATION Qualified service persons should handle this installation Installation must conform to all local codes 5 1 Model Designation Power Transformer Model Rated Voltage Voltage Nominal No Input Range Output Power LTC 9384 60 115VAC 108to132 24VAC 30W 50 60Hz 50 60Hz LTC 9384 20 24VAC 21 6 to 26 4 24VAC 30W 50 60Hz 50 60Hz LTC 9384 50 230VAC 207 to 253 24VAC 30W 50 60Hz 50 60Hz LTC 9384 20NT 24VAC 21 6 to 26 4 30W 50 60Hz The power transformers included with these housings are used to provide heater power and can be used to provide isolated camera power Heater requires 10 watts Do Not Exceed 30VAC
17. flying leads to the camera s 24 volt input See wiring diagram FIGURE 9 for clarification and FIGURE 5 for power connection drawings EN 11 To Heater Defogger 12 White Black Striped 24VAC 24VAC Input To Camera White Black 7 Striped To Heater Defogger FIGURE 9 LTC 9384 20 Transformer Wired for 24 Volt Camera 5 6 6 LTC 9384 50 Housings These housings require connection to 230VAC and are designed for use where the site power is 230 volts The LTC 9384 50 Housings can easily be used with either 230 volt or 24 volt cameras The internal transformer provides 24VAC for both the heater and 24 volt camera power Do not remove the transformer insulator No user serviceable parts are present For 230 Volt Cameras 1 Installing a 230 volt camera into the LTC 9384 50 housing requires the camera s line cord to be cut and connected with the transformer s primary wiring and the power supply line see FIGURE 10 2 The secondary flying leads white black striped will not be used in this application and should be taped to prevent shorting See wiring diagram FIGURE 10 for clarification and FIGURE 5 for power connection drawings To Camera To Heater Defogger White Black Striped Connector Black 6 230 VAC Input 24VAC No Connection Connector Blue Blue To Camera To Heater Defogger FIGURE 10 LTC 9384 50 Transtormer Wired for 230
18. l macht auf nicht isolierte gef hrliche Spannung im Geh use aufmerksam Dies kann zu einem elektrischen Schlag f hren Der Benutzer sollte sich ausf hrlich ber Anweisungen f r die Bedienung und Instandhaltung Wartung in den begleitenden Unterlagen informieren Achtung Die Installation sollte nur von qualifiziertem Kundendienstpersonal gem jeweils zutreffender Elektrovorschriften ausgef hrt werden Unterbrechung des Netzanschlusses Ger te mit oder ohne Netzschalter haben Spannung am Ger t anliegen sobald der Netzstecker in die Steckdose gesteckt wird Das Ger t ist jedoch nur betriebsbereit wenn der Netzschalter EIN AUS auf EIN steht Wenn das Netzkabel aus der Steckdose gezogen wird ist die Spannungszufiihrung zum Ger t vollkommen unterbrochen EC CE Precauciones de Seguridad EN PERICOLO DI SCOSSA ELETTRICA NON APRIRE S curit ER RISQUE D LECTROCUTION NE PAS OUVRIR ATTENTION POUR EVITER TOUT RISQUE D ELECTROCUTION N ESSAYEZ PAS DE RETIRER LE CAPOT OU LE PANNEAU ARRIERE CET APPAREIL NE CONTIENT AUCUN COMPOSANT SUSCEPTIBLE D ETRE REPARE PAR L UTILISATEUR CONFIEZ LA REPARATION DE L APPAREIL A DU PERSONNEL QUALIFIE Ce symbole signale que le produit renferme une tension potentiellement dangereuse non isol e susceptible de provoquer une lectrocution Ce symbole invite l utilisateur consulter les instructions d utili
19. m this section depending on which Housing is being used 1 Use the liquid tight fitting on the left hand side of the housing to route the power wire into the 5 6 4 LTC 9384 60 Housings housing The LIC 9384 60 Housings can easily be used with WAGO Connectors either 115 volt or 24 volt cameras After Connecting Wires Push Into Cavity The internal transformer provides 24VAC for both the heater defogger and 24 volt camera power see Fuse Holder FIGURE 5 7 Tie Wraps For 115 Volt Cameras 1 Installing a 115 volt camera into the LTC 9384 60 housing requires the camera s EEN line cord to be cut and connected with the Liquid tight Fitting Transformer CCD Camera Shown Underneath transformer primary leads and the power supply line see FIGURE 7 FIGURE 5 Power Connections 2 The secondary flying leads white black striped 2 A screw terminal lug is provided for securing a will not be used in this application and should safety ground Attach the terminal lug to the be taped to prevent shorting See wiring cradle using the M4 x 10 screw provided diagram FIGURE 7 for clarification and FIGURE 5 for power connection drawings To Camera To Heater Defogger White Black Striped II LI5VAC 24VAC No Connection Input Terminal Lug White Black Striped FIGURE 6 Securing the Ground Wire To Camera To Heater Defogger 3 Pull any excess wire out of the cradle as
20. our dealer or local power company For units intended to operate from battery power refer to the operating instructions For units intended to operate with External Power Supplies use only the recommended approved power supplies For units intended to operate with a limited power source this power source must comply with EN60950 Substitutions may damage the unit or cause fire or shock For units intended to operate at 24VAC normal input voltage is 24VAC Voltage applied to the unit s power input should not exceed 30VAC User supplied wiring from the 24VAC supply to unit must be in compliance with electrical codes Class 2 power levels Do not ground the 24VAC supply at the terminals or at the unit s power supply terminals Coax Grounding If an outside cable system is connected to the unit ensure that the cable system is grounded U S A models only Section 810 of the National Electrical Code ANSI NFPA No 70 provides information regarding proper grounding of the mount and supporting structure grounding of the coax to a discharge unit size of grounding conductors location of discharge unit connection to grounding electrodes and requirements for the grounding electrode Grounding or Polarization This unit may be equipped with a polarized alternating current line plug a plug with one blade wider than the other This safety feature allows the plug to fit into the power outlet in only one way If unable
21. rvice personnel Damage Requiring Service Unplug the unit from the main AC power source and refer servicing to qualified service personnel under the following conditions 12 When the power supply cord or plug is damaged If liquid has been spilled or an object has fallen into the unit If the unit has been exposed to water and or inclement weather rain snow etc If the unit does not operate normally when following the operating instructions Adjust only those controls specified in the operating instructions Improper adjustment of other controls may result in damage and require extensive work by a qualified technician to restore the unit to normal operation If the unit has been dropped or the cabinet damaged If the unit exhibits a distinct change in performance this indicates that service is needed 13 Replacement Parts When replacement parts are required the service technician should use replacement parts specified by the manufacturer or that have the same characteristics as the original part Unauthorized substitutions may result in fire electrical shock or other hazards Safety Check Upon completion of servicing or repairs to the unit ask the service technician to perform safety checks to ensure proper operating condition EN 2 Power Sources Operate the unit only from the type of power source indicated on the label If unsure of the type of power supply to use contact y
22. s Use a tie wrap included to provide strain relief on the video cable at the exit point inside the unit EN 12 3 Install the 38in NPT plug provided in the unused small top center NPT hole Securely tighten all fittings to ensure a liquid tight seal Failure to do so could allow water to enter the housing and damage the camera and lens 5 8 Lens Wiring WARNING Use only the cables specified under INSTALLATION Cable Requirements for video coax wiring connection 1 Tf installing a zoom lens insert the lens control cable with the installed seal cap in through the right fitting at the rear of the cradle Attach the lens wiring to the lens mating connector and connect it to the lens If the mating connector is not available connect directly to the lens cable NOTE See the specification on lens cord for the correct plug connection Securely tighten all fittings to ensure a liquid tight seal Failure to do so could allow water to 2 If using a pan tilt with a feed through cable enter the housing and damage the camera and lens insert the camera lens function cable in through the right hand fitting at the rear of the cradle Wire the functions as described above or as needed Use of drip loops is not recommended on the wiring outside of the rear endcap 5 9 Final Assembly 5 9 1 Pull Seal Installation If the breather hole is open do NOT mount the housing in a position where the front
23. sation et d entretien d pannage reprises dans la documentation qui accompagne l appareil EI Attention l installation doit exclusivement tre r alis e par du personnel qualifi conform ment au code national d lectricit am ricain NEC ou au code d lectricit local en vigueur Coupure de l alimentation Qu ils soient pourvus ou non d un commutateur ON OFF tous les appareils re oivent de l nergie une fois le cordon branch sur la source d alimentation Toutefois l appareil ne fonctionne r ellement que lorsque le commutateur est r gl sur ON Le d branchement du cordon d alimentation permet de couper l alimentation des appareils D La Veiligheidsmaatregelen EN GEVAARVOOR ELEKTRISCHE SCHOK NIET OPENEN PRECAUCION PARA DISMINUIR EL RIESGO DE DESCARGA ELECTRICA NO RETIRE LA CUBIERTA NI LA PARTE POSTERIOR NO EXISTEN PIEZAS DE RECAMBIO EN EL INTERIOR DEL EQUIPO EL PERSONAL DE SERVICIO CUALIFICADO SE ENCARGA DE REALIZAR LAS REPARACIONES VOORZICHTIG OPEN DE BEHUIZING OF DE ACHTERKANT VAN HET APPARAAT NIET ZO VERMINDERT U HET RISICO OP ELEKTRISCHE SCHOKKEN IN HET APPARAAT BEVINDEN ZICH GEEN ONDERDELEN DIE U ZELF KUNT REPAREREN LAAT SERVICE EN ONDERHOUD UITVOEREN DOOR GEKWALIFICEERD PERSONEEL Este s mbolo indica que existen puntos de tensi n peligrosos sin aislamiento dentro de la cubierta de la unidad Estos puntos pueden constituir un riesgo de descarga el ctric
24. sembly and tighten the fitting to 8 5 N m to 9 0 N m FIGURE 7 LTC 9384 60 Transformer Wired for 75in lb to 80in lb This torque rating is 115 Volt Camera approximately 1 to 11 2 turns past the point where the fitting starts to grip the wire Failure Bosch Security Systems September 1 2004 LTC 9384 Series Instruction Manual Installation For 24 Volt Cameras 1 Installing a 24 volt camera into the LTC 9384 60 Housing uses the internal transformer for camera power see FIGURE 7 2 Connect the supply 115VAC to the primary flying leads of the transformer white wire pin 1 black wire pin 6 Use the wire nuts provided for this connection 3 Connect the secondary flying leads white black striped wires pins 7 and 12 to the camera s 24 volt input See wiring diagram FIGURE 8 for clarification and FIGURE 5 for power connection drawings To Heater Defogger White Black Striped 115 VAC 24 VAC To Camera Input White Black Striped FIGURE 8 LTC 9384 60 Transformer Wired for 24 Volt Camera 5 6 5 LTC 9384 20 Housings These housings are to be connected to 24VAC only and are designed for use where the site power is 24 volts The LIC 9384 20 housings are designed to be used with 24 volt cameras only 1 Connect the supply 24VAC to the primary flying leads of the transformer Use the wire nuts provided for this connection see FIGURE 9 2 Connect the secondary
25. tems GmbH 3935 890 40912 04 36 September 1 2004 Data subject to change without notice BOSCH
26. thwire 573939 Voltage Rating Sources EN 8 Input Power Cord European Cable Type HOSRN F3G0 75 and HO5RN F3G1 00 Cable Size Outside diameter between 4 3mm 0 170in and 11 9mm 0 470in Conductors 3 conductor version and 2 conductor version Sources Olflex 1600252 Olflex 1600253 Lens Control Cable Outside Diameter between 4 3mm 0 170in and 11 9mm 0 470in CN TN Sources Belden 9552 Belden 9554 5 4 Cradle Removal 1 Remove the cradle from the housing by lowering the retaining screw completely on the bottom rear of the housing 2 Remove the cradle assembly by pushing gently on the metal part of front cap and simultaneously grasping the rear handle and pulling the cradle assembly out of the housing Be sure to keep the edges of the endcaps clean and free of scratches see FIGURE 1 Retention Screw FIGURE 1 Removing the Cradle Assembly Bosch Security Systems September 1 2004 LTC 9384 Series Instruction Manual Installation 5 5 Camera Lens Installation With the cradle removed from the housing place the camera lens combination into the cradle assembly 1 Fixed Lens Cameras Position the camera lens Imm 0 04in away from the faceplate The camera lens is secured to the cradle with a 1 4 20 button head cap screw BHCS and the appropriate plastic spacer see FIGURE 2 Spacers 1 4 20 Screws FIGURE 2 Mounting the Camera and Lens 2 Zoom Lens Cameras Allow
27. ting temperature requirements 2 Mechanical Loading Mounting of the equipment in a rack shall be such that a hazardous condition is not achieved due to uneven mechanical loading SERVICE PERSONNEL This symbol indicates the presence of uninsulated dangerous voltage within the product s enclosure This may constitute a risk of electric shock The user should consult the operating and maintenance servicing instructions in the literature accompanying the appliance GD D gt Attention Installation should be performed by qualified service personnel only in accordance with the National Electrical Code or applicable local codes Power Disconnect Units with or without ON OFF switches have power supplied to the unit whenever the power cord is inserted into the power source however the unit is operational only when the ON OFF switch is in the ON position The power cord is the main power disconnect for all units Bosch Security Systems September 1 2004 LTC 9384 Instruction Manual Safety Precautions EN 4 Sicherheitshinweise EN ELEKTRISCHE SPANNUNG NICHT OFFNEN VORSICHT UM EINEN ELEKTRISCHEN SCHLAG ZU VERMEIDEN IST DIE ABDECKUNG ODER RUCKSEITE NICHT ZU ENTFERNEN ES BEFINDEN SICH KEINE TEILE IN DIESEM BEREICH DIE VOM BENUTZER GEWARTET WERDEN KONNEN LASSEN SIE WARTUNGSARBEITEN NUR VON QUALIFIZIERTEM WARTUNGSPERSONAL AUSFUHREN Das Symbo
Download Pdf Manuals
Related Search
Related Contents
セルフロック (Page 3) Church 397CT 000 Installation Guide User Guide for Vortex 850R Series Sony DSC-T1 Instruction Guide Loudspeaker System Specifications Altronix RB1224 power relay Dual boot Windows 8 with Linux 観測機器リスト 1 - Scope People Le phare - Santillana Français Rouleuse 4132 Copyright © All rights reserved.