Home

Bionaire BASF17V User's Manual

image

Contents

1. BASF17V Fig 1 BASF17VRC Fig 2 U UO gt mn r Qc U G H F E A D B
2. The Remote Control requires 2 AAA batteries for operation To install the batteries not included simply depress the back of the remote with your thumb in the indentations and remove the cover Insert the batteries according to the diagram shown inside Replace the cover All function keys are enabled after pressing the On Speed key using the Remote Control unit V or the Control Pad W On Speed C 1 To turn the fan On press the On Speed button The fan will start to operate at the low speed You may now choose alternative settings 2 The fan will be turned Off when you press the Off O 3 By pressing the On Speed button you can choose 3 different soeeds successive presses of the On Speed button cycles the fan through the 3 speeds available 4 The LED lamp on the Control Pad indicates the selected speed stage III II I Timer amp 1 You can choose different timer stages by AN ay pushing the Timer button 2 The LED lamp on the Control Pad indicated the selected time in hours After the selected time the fan will stop automatically 3 If no timer LED lamps are lit the fan will run constantly 4 The memorized time displayed on the keypad is cumulative i e if the 1 hour and 0 5 hour LEDs are lit the fan will switch off after 1 5 hours The maximum memorized time is 7 5h each press of the Timer button adds 0 5 of an hour Oscillation By pressing the Oscillation button the fan
3. 10 Centre the front grill P by aligning the Bionaire logo on the logo plate so that it is horizontal and parallel with the floor Then holding the front grill against the rear grill hook the top of the grill ring over the to of the rear grill Gently push the two parts of the grill together until the clips around the D N grill ring snap into position holding the grill together The grill ring must fit evenly around the front and rear grills If it does not remove the front grill and check the alignment of the ring on the front grill 11 Secure the guard using the screw Q washer R and clip S by inserting the screw from the front through the hole in the bottom of the guard ring From the back put the washer and clip which has a threaded hole onto the screw ensuring the clip is the correct way to fit into the recess on the fan ring Tighten the screw fully but do not overtighten OPERATING INSTRUCTIONS 1 Set fan on a dry level surface 2 Plug cord into any standard 220 240 volt outlet Please make sure the speed control is in the off position For BASF17V only 1 The SPEED is adjusted by pressing the Control Pad button W to the desired setting Off O High III Med II Low I 2 The OSCILLATION control T is located on the top of the fan motor housing To start oscillation push the control know down To stop oscillation pull the control knob up For BASF17VRC only REMOTE CONTROL
4. BASF17V 17VRCIUKO4EM1 qxd 12 10 04 09 21 FAN STORAGE When storing your fan in the off season it is important to keep it in a safe dry location It is important to protect the fan from dust Page 1 GUARANTEE PLEASE KEEP YOUR RECEIPT AS THIS WILL BE REQUIRED FOR ANY CLAIMS UNDER THIS GUARANTEE P J 1 8 NUN STAND fan WE STRONGLY RECOMMEND USING THE e This product is guaranteed for 3 years ORIGINAL BOX FROM PURCHASE In the unlikely event of breakdown please FITTING A REPLACEMENT PLUG FOR take it back to the place of purchase with U K AND IRELAND ONLY your till receipt and a copy of this guarantee If the plug is not suitable for the socket outlets in The rights and benefits under this guarantee your home it can be removed and replaced by are additional to your statutory rights which a plug of the correct type Please refer to are not affected by this guarantee Installation of a plug below e Holmes Products Europe undertakes within the specific period to repair or replace free INSTALLATION OF A PLUG of charge any part of the appliance found to APPLICABLE TO U K AND IRELAND be defective provided that The wires in this mains lead are coloured in e We are promptly informed of the defect accordance with the following code e The appliance has not been altered in any way or subjected to misuse or repair by a person other than a person authorised by Holmes Products Europe This appliance is fitt
5. begins to oscillate Re press the button to stop Breeze Mode By pressing the Breeze Mode key different functions can be chosen 1 Natural Breeze Mode press Breeze Mode button once The Mode LED flashes and the fan operates at different soeed stages alternately to imitate a natural breeze To de activate the Natural breeze mode function switch the fan off 2 Sleeping Breeze Mode press Breeze Mode button twice Sleeping breeze mode can be used in association with the Timer see above Timer section for details By setting different timer durations at Sleeping breeze mode the fan operates at decreasing speed stages until the memorized timer duration is reached The LED lamp is continuously on To de activate the Sleeping breeze mode function switch the fan off ADJ USTMENT INSTRUCTIONS Fan Head Tilt Adjustment 1 To change the tilting angle of the fan head simply loosen the tilt adjustment knob U 2 Move the fan head to the desired angle and firmly tighten the tilt adjustment knob U to lock into place Height adjustment Follow these instructions to adjust the height of the fan 1 Turn the pole locking knob E anticlockwise to loosen the pole 2 Adjust the pole to the desired height and firmly tighten the locking knob in a clockwise direction CLEANING AND MAINTENANCE e Always unplug the fan before cleaning or disassembly e Do not allow water to drip on or into the fan motor housing
6. ed with a 13 amp plug e No rights are given under this guarantee to BASF 1 V BASF1 VRC J BIONAIRE Holmes Products Europe Ltd 1 Francis Grove London SW19 4DT Blue Neutral Brown Live The fuse should be rated at 3 amps and ASTA a person acquiring the appliance second England approved to BS1362 hand or for commercial or communal uses However if the plug is unsuitable it should be e Any repaired or replaced appliance will be Fax 44 0 20 8947 8272 guaranteed on these terms for the remaining portion of the guarantee removed from the supply cord and an appropriate plug fitted as detailed below As the colours of the wires in the mains lead of this appliance may not correspond with the THIS PRODUCT IS MANUFACTURED TO coloured markings identifying the terminals in COMPLY WITH THE E E C DIRECTIVES your plug proceed as follows 73 23 EEC 89 336 EEC AND 98 37 EEC The wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Black The wire which is coloured Brown must be connected to the terminal which is marked with the letter L or coloured Red NB Neither wire should be connected to the terminal in your plug which is marked with the letter E or by the Earth symbol or coloured Green or Green and Yellow If in doubt consult a qualified electrician If any other plug is used a 3 amp fuse must be fitted either in the plug or adaptor or at the distribution boa
7. lignment of four holes Then use four cross base screws C to lock them together 2 Slide the stand base sheath D into the main pole Unscrew the pole extension screw E around the top of the main pole and raise the chrome extension pole F to its full height Retighten the pole extension screw 4 Take the fan head assembly G slacken the fixing screw H and insert the neck of the fan head assembly onto the pole Retighten the fixing screw pa Head and guard 5 Unscrew the fan blade securing screw l NOTE THIS SCREW HAS LEFT HANDED THREAD AND THEREFORE IS REMOVED BY TURNING CLOCKWISE Unscrew the rear grill mounting nut J Position the rear grill K over the motor shaft L making sure the notches M 2 at the top and 1 at the bottom of the rear grill fit over the corresponding prongs N on the motor housing Please make sure the rear grill fits securely against the motor housing before securing the rear grill in its place using the rear grill mounting nut J Turn this nut clockwise and tighten firmly 8 Slide the fan blade O with the hollowed interior of the blade facing toward the rear grill firmly onto the motor shaft The top of the motor shaft should lie even with the centre of the fan blade 9 Now use the securing screw I to lock the blade into place NOTE THIS SCREW HAS ALEFT HANDED THREAD AND THEREFORE TIGHTENS ANTICLOCKWISE Ensure the screw is tight but do not overtighten
8. rd Email info europe theholmesgroup com Website address www theholmesgroup com europe UK Free phone Customer Service Helpline 0800 052 3615 Blue Brown Neutral Live NOTE If the terminals in the plug are not marked or if you are unsure or in doubt about the installation of the plug please contact a qualified electrician If a 13A 3 pin plug is fitted it must be an ASTA approved plug conforming to BS1363 standard C Replacement 3A fuses must be BSI or ASTA 9100010004639 BS1362 approved BASF17V VRCIUK04EM1 INSTRUCTION MANUAL om BASF17V 17VRCIUKO4EM1 gqxd 12 10 04 09 21 U K and IRELAND PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS When using electrical appliances basic safety precautions should always be taken including the following e Use the fan only for purposes described in the instruction manual e To protect against electrical shock do not immerse the fan plug or mains cable in water or spray with liquids e Close supervision is necessary when any appliance is used by or near children e Unplug from the electrical outlet when not in use when moving the fan from one location to another before putting on or taking off parts and before cleaning e Avoid contact with any moving parts e Do not operate in the presence of explosives and or flammable fumes e Do not place the fan or any parts near an open flame cooking or other heating appliance e Do not operate an
9. y appliance with a damaged mains cable plug after the appliance malfunctions or has been dropped damaged in any manner e The use of attachments not recommended or sold by the appliance manufacturer may cause hazards e Do not let the mains cable hang over the edge of a table or counter or come into contact with hot surfaces e To disconnect from the electrical supply grip the plug and pull from the wall outlet DO NOT pull on the mains cable e Always use on a dry level surface e Do not operate without the fan grills properly in place e This product is intended for household use ONLY and not for commercial or industrial applications e Should the appliance stop working first check the fuse in the plug UK only or fuse circuit breaker at the distribution board is operating before contacting the manufacturer or service agent e If the supply cord or plug is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid hazard e The appliance contains no user serviceable parts and should the product suffer damage or breakdown it must be returned to the manufacturer or its service agent Page 4 e Do not use outdoors e The fan should not be operated without its base fitted e The fan should not be operated laying on its side ASSEMBLY INSTRUCTIONS See Fig 1 and 2 Base and pole 1 Slide the main pole A on the cross base B making sure the a

Download Pdf Manuals

image

Related Search

Related Contents

installation, use & care manual 30” double built-in oven    Makita GV7000C User's Manual  Anleitung TAXI 2400  取扱説明書(PDF:1.46MB)  Hitachi CP-S833W User's Manual  Directions for use, Welch Allyn Connex® Vital Signs Monitor 6000  デジタル スケールベッド WAKシリーズ    

Copyright © All rights reserved.
Failed to retrieve file