Home

Belkin F6H350-USB User's Manual

image

Contents

1. You a single user opening this envelope You or our may use the software on a single central processing unit You may not rent it loan it out or lease it nor use it on a multi user system LICENSE You have the non exclusive right to use the software You are not permitted to copy modify or transfer the software or documentation You may not compile disassemble or otherwise reverse engineer break down analyze or modify the software USE AND RESTRICTIONS You are permitted to make backup copies of all the software disks for archival purposes only You must reproduce the proprietary notice set forth on the disks and affix them to all backup copies You are not permitted to use these programs in connection with a computer service or to use the backup copies other than as a replacement for the original copy TERM This license is effective upon acceptance by opening this envelope or in any other way using the enclosed software which will constitute your acceptance of and agreement to this Agreement and is effective until terminated The limited license in this Agreement will be automatically terminated if you fail to comply with any of the Terms and conditions in this Agreement You agree that upon such termination you will immediately destroy all programs and documentation including all copies made or obtained by you SOFTWARE PROGRAM DOCUMENTATION AND ANY RELATED INFORMATION GOODS OR SERVICES ARE PROVIDED WITH NO WARRANTY OR REPRESE
2. 654 73 49 Belkin Australia Ltd 7 Bowen Cresent West Gosford NSW 2250 Tel 61 02 4325 4666 Fax 61 02 4325 4277
3. Type click ALL Standalone You should not install the networking files unless you are technically qualified to use these features For more information on networking please refer to the software user s manual The software user s manual can be downloaded from the user s manual icon 9 On Choose Destination you have the option to choose the location of where you would like the Sentry Software located on your computer We recommend using the default option as shown on screen To use the default option click Next 10 On Select Program Folder you have the option to choose the program folder for you Sentry Software We recommend using the default option as shown on screen To use the default option click Next 11 The software will now upload Once completed please click Finish 12 We recommend that you download the user s manual you re your reference Todo this please click the appropriate user s manual listed on the screen 13 Click X on the Bulldog setup screen to leave the software setup 14 Please refer to the user s manual for software setup and information on software specific features and functions Uninstall for Windows 95 98 Me NT4 2000 XP There are two options to uninstall the Sentry Belkin Shutdown Software 1 Select the Setup from the BELKIN SENTRY BULLDOG program folder and select the remove option to begin the uninstall procedure 2 Select Add Remove Programs from the Control Panel and cli
4. F6H350 USB F6H500 USB F6H650 USB USER INTRODUCTION Thank you for purchasing a Belkin Uninterruptible Power Supply UPS Each year several natural and man made occurrences put the power supplied to your electronics in your home or office in jeopardy At risk are your hardware software and data because of these power problems IMPORTANT SAFETY INSTRUCTIONS Please save this manual It contains important operating instructions and warranty information pertaining to your UPS Please save or recycle the packaging materials The UPS packaging was designed with great care to provide protection during shipment and delivery These materials are invaluable if you ever have to return the UPS for service Damage sustained during transit is not covered under the warranty Federal Communications Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications To assure continued compliance use only shielded interface cables when connecting to computer or peripheral devices Any changes or modifications not expressly approved b
5. NTATION OF ANY KIND WHAT SO EVER BELKIN HEREBY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The entire risk of the use results and performance of the software program and documentation is borne by you Should any or all of the product software program documentation or related information goods or services be defective misused unsuitable or cause or give rise to any harm or liability whatsoever you not Belkin or its associates dealers or agents assume the entire liability cost of repair correction or any payment or other remedy whatsoever Furthermore no warranty or guarantee is made regarding the use or results of the product software program documentation or any related information goods or services in terms of correctness accuracy reliability timeliness or otherwise You use and rely on the program at your own risk The following is the only and exclusive warranty and remedy of any kind Belkin does warrant that the program disks are free from physical defects in materials and workmanship under normal use for a period of one 1 year from the date of purchase as evidenced by a copy of the sales receipt Return the defective disk or documentation with your receipt directly to Belkin for a replacement DISCLAIMER Belkin or its associates will in no event be liable i in any amount for lost profits or special in
6. cidental punitive or consequential damages or ii for any claim or damage of any nature or under any theory whatsoever in any amount in excess of the purchase price you paid for the product The warranties and remedies here set forth are exclusive and in lieu of all others oral or written express or implied Some jurisdictions do not allow exclusion or limitation of implied warranties or of liability for incidental damages so the foregoing limitations or exclusion may not apply to you This warranty gives you specific legal rights which vary from jurisdiction to jurisdiction HOWEVER YOU WAIVE SUCH RIGHTS EXCEPT AS EXPRESSLY PROVIDED UNDER THE TERMS AND CONDITIONS OF THIS AGREEMENT TO THE MAXIMUM EXTENT ALLOWED BY LAW The license is governed by the laws prevailing in the State of New York without regard to its conflicts of laws principles ACKNOWLEDGMENT By opening the package on which this Agreement is printed or through which it is visible you acknowledge that you have read this Agreement understand it and agree that this agreement is the complete and exclusive statement of agreement between yourself and Belkin and supersedes any prior agreements oral or written and any other communications relating to the subject matter of this Agreement SEVERABILITY Any term or provision of this Agreement or any application thereof which may be prohibited or unenforceable by law in a particular jurisdiction shall be interpreted a
7. ck on the BELKIN SENTRY BULLDOG item then press the Add Remove button TECHNICAL SPECIFICATIONS F6EH350 F6H500 F6H650 MODEL RATED 350VA 500VA 650VA CAPACITY 190W 300W 360W INPUT RATED VOLTAGE 105 135Vac PHASE FREQUENCY Single phase 60HZ St outpur VOLGE FREQUENCY 60HZ Desktop Desktop Desktop Couer compuier computer BACK UP TIME 15 17 17 BATTERY monitor monitor monitor 10mm 13mm 17mm RECHARGE TIME lt 8hours to 90 0 35 ENVIRONMENT LLEMPERATURE HUMIDITY 10 90 SAFETY UL1778 C UL SAFETY REGULATION FCC CLASS B IEEE C62 41 CATEGORY A DIMENSION 3 14 X 9 84 X 6 6 inches APPEARANCE 4 0KGS 4 6KGS 5 6KGS NET WEIGHT 882LBS 10 14LBS 12 35LBS All specifications are subject to change without prior notice TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION On Off button not Press the On Off pushed or pushed button more than 2 less than 1 second second Battery voltage Recharge the UPS at less than 10V least 5 hours Contact Belkin Technical support at techsupp belkin com Re plug the power Power LED is not lit UPS will not power on UPS fault UPS always on fe Taa Is Reset the breaker battery mode PP Power disturbances have occurred Normal operations Battery is not fully charged Recharge the UPS for a minimum of 6 hours Remove un necessary power loads devices Back up time UPS is overloaded is very short Contact Belkin T
8. e signal to support DOS WINDOWS and the other operating system a Communication port Optional To fully utilize the Sentry Bulldog Shutdown Software you will need to connect the UPS to your computer Connect the USB cable to your UPS then connect the other end to the USB port on your computer Software Installation Optional Compatible with any computer running the following 95 98 ME NT4 2000 XP amp Novell 3 X amp Higher 1 Your UPS features the Sentry Bulldog Shutdown Software This allows you to protect and save your data should a power outage occur as well as safely shutdown your computer in your absence This software is compatible with Windows 95 98 ME NT4 2000 XP and Novell 3 X amp higher 2 To install the software please place the CD into the CD drive of your computer 3 Your computer should automatically run AutoPlay the CD If this does not occur go to the Run feature on your Start icon lower left corner on your screen Please enter the CD drive it may be D Should you continue to have a problem please refer to your computer s owner s manual for the correct drive Upon entering the drive Run setup exe to execute the software 4 Once uploaded please click the Bulldog icon on the screen 5 Click Install Belkin Sentry Bulldog for Win 95 98 ME NT4 2000 XP 6 InstallShield Wizard will appear onscreen click Next 7 Please read the License Agreement and click Yes 8 On Setup
9. echnical support at techsupp belkin com STORAGE Storage Conditions UPS fault Store the UPS covered and upright in a cool dry location with its battery fully charged Before storing charge the UPS for at least 6 hours Extended Storage During extended storage in environments where the ambient temperature is 5 F to 86 F charge the UPS battery every 6 months During extended storage in environments where the ambient temperature is 86 F to 113 F charge the UPS battery every 3 months Note ote r Away from sunlight Away from heat Away from water BELKIN COMPONENTS USER LICENSE AGREEMENT Belkin Components Belkin thanks you for choosing one of our products for your use This User License Agreement Agreement contains the terms and conditions under which limited use of the product is licensed to you PLEASE READ THIS NOTICE CAREFULLY DO NOT USE THE SOFTWARE OR PRODUCT UNTIL YOU HAVE READ AND AGREED TO THIS AGREEMENT IF YOU USE THE SOFTWARE AND PRODUCT YOU ARE AGREEING TO THE TERMS AND CONDITIONS SET OUT IN THIS AGREEMENT IF YOU DO NOT ACCEPT THESE TERMS AND CONDITIONS YOU MUST RETURN THE UNOPENED PRODUCT WITH THE DISKS INSIDE TO THE PARTY FROM WHOM YOU RECEIVED IT SCOPE OF USE In this Agreement software means all machine readable software programs and associated files in this package All modified versions of and upgrades or improvements to such programs and all copies of such programs and files
10. ess the Power button Side Panel B USB Communication Port Diagram 3 7 Your UPS features a USB communication port Installation of the cable and software is optional This allows the UPS to connect to you computer The Sentry Bulldog Software will not work if the UPS is not connected to you computer This does not mean the battery backup feature will not work without the software and cable installed The UPS will still provide backup power but you will be unable to utilize the data management capabilities of the software INSTALLATION Note a Before installation please inspect the UPS Upon al receipt Make sure that everything inside the package iis is not damaged Connect to AC Utility Power Connect the AC inlet to utility power via the power cord Please make sure there are no devices plugged into the UPS unit Check to see if the Site Wiring Fault indicator is lit or not If it is lit please have the utility wiring inspected by an electrician Charging the Battery For best results charge the battery for 6 hours prior to initial use The UPS charges its battery whenever it is connected to the utility power Should you see the red battery light come on the battery may need immediate charging Battery Light Turning on the UPS Turn on your UPS by depressing the On Off button for approximately 2 seconds You will see the green indicator light come on Pl
11. n ON LINE Back Up Slow Alarm When in BACK UP on battery mode the RED LED illuminates and the UPS sounds an audible alarm The alarm stops when the UPS returns to LINE NORMAL operation Low Battery Rapid Alarm In BACK UP mode when the battery energy runs low the UPS beeps rapidly until the UPS shuts from a depleted battery or returns to LINE NORMAL operation Fault 10 Seconds Continuously When the output is shorted the UPS emits a 10 seconds continuously alarm to warn of a short condition Disconnect the equipment prior to checking the equipment FRONT PANEL Diagram 1 1 UPS Outlets See 1 on Diagram 1 These outlets are your battery back up outlets We strongly recommend that only sensitive equipment such as your computer and monitor should be plugged into these outlets Caution Never connect a laser printer or scanner to the backup outlets of UPS with other computer equipment A laser printer or scanner draws significantly more power when in use than when sitting idle This may overload the UPS Should a power outage occur your battery backup would automatically turn on Power utility or battery is not supplied to these outlets when the UPS is switched off Do not plug any surge protectors or power strips into the batte
12. nd enforced to the maximum extent allowed in such jurisdiction which the parties acknowledge could mean severing the provision from this Agreement or if allowed enforcing it in a narrower form without affecting the remainder of this Agreement or any other application of such term or provision in such jurisdiction or application of such term or provision in any other jurisdiction SAFETY INFORMATION CAUTION Internal battery voltage is 12V DC The unit is intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants All batteries used are Sealed Lead Batteries Batteries must be recycled RECYCLING INFORMATION Your UPS contains a Non spill Sealed Lead Battery On the battery you will find the battery name Please reference the chart below for recycling information Battery Name Recycling Inside the USA BB Battery 800 278 8599 N A Recycling Outside the USA CSB Battery 800 738 7372 1 817 244 4415 VISION Battery 973 726 5323 N A CONTACT US Belkin Components 501 West Walnut St Compton CA 90220 5221 USA Tel 310 898 1100 Fax 310 898 1111 Belkin Components Ltd Unit 13 Gatelodge Close Round Spinney Northampton NN3 8RX UK Tel 44 0 1604678300 Fax 44 0 1604678330 Belkin Components B V Starparc Building Boeing Avenue 333 1119 PH Schiphol Rijk The Netherlands Tel 31 0 20 654 73 00 Fax 31 0 20
13. ry back up outlets i e daisy chaining 2 SURGE Protected outlets See 2 on Diagram 1 These outlets do not provide power during a power outage Equipment such as computer peripherals printers fax machine s or a desk lamp may be plugged into these outlets The On Off button does not control these outlets 3 The On Off button has 3 functions 1 Turns on the UPS Depress button at least 2 seconds The green light will come on 2 Cold Start function Assuming the battery is charged the UPS will work without it being plugged into an outlet Depress and hold the key for at least 2 seconds to turn on the UPS The i 3 Silence function During On Battery Mode the Battery Light audible sound can be turned ON or OFF by depressing the switch Side Panel A Diagram 2 4 AC Input Power Cord See 1 on Diagram 2 Provides power to your UPS 5 Phone Fax Modem Surge Protection See 2 on Diagram 2 The Phone Fax Modem lines are surge protected There is one input jack and two output jacks This allows you to split one telephone connection to two separate devices 6 AC Breaker Circuit Breaker See 3 on Diagram 2 Should a power overload occur the circuit breaker would trigger the UPS to turn off AC power In order to restore the power depress the circuit breaker button to reset then depr
14. ug in Power Devices Plug your devices into the AC outlets on the top of the UPS To use the UPS as a master on off switch make sure all of the loads are switched on Caution Never connect a laser printer or scanner to the backup outlets of UPS with other computer equipment A laser printer or scanner draws significantly more power when in use than when idles This may overload the UPS Connect the phone fax modem lines Connect a single phone fax modem line into the surge protected sockets on the right of the UPS The RJ 11 modular sockets accept standard single line telephone connections Plug one end of the phone cable you received into your telephone wall jack and plug the other end into the jack marked IN You may now plug a phone fax or modem into the two jacks marked OUT See Diagram 4 Modem To Telephone Socket Fax Diagram 4 Note This connection is optional but highly suggested as phone fax modem lines often carry dangerous surges and spikes The UPS works properly without a phone fax modem connection Caution The phone fax modem protection feature could be rendered inoperable if improperly installed Make sure that the telephone line from the wall is plugged into the connector marked IN and the devices to be protected phone fax modem are plugged into the connector marked OUT USB Universal Serial Bus Communication Port A USB port is provided to relay th
15. y the party responsible for compliance could void the user s authority to operate this equipment CONTENTS You should have received the following 1 UPS unit 1 Sentry Bulldog Shutdown Software 1 USB Cable 1 Phone Line Cable UPS FEATURES AND FUNCTIONS Before installation please inspect the UPS upon receipt Make sure that nothing is damaged Your UPS features 3 LED indicators Each is marked by a power icon please familiarize yourself with this chart as it will assist you in the use of your UPS This condition for the On Battery and Low Battery LED can indicate 1 of 3 problems 1 The UPS is on battery backup and an intermittent audible alarm is on The UPS will begin shutdown procedure Flashing Red ON BATTERY and LED with Audible LOW BATTERY Battery is low The UPS will start shutdown The buzzer sounds an audible alarm Alarm Beeping There is a problem with the UPS The LED will be lit continuously and the buzzer will sound audible alarm for 10 Sec The Site Wiring fault LED can indicate 1 of 2 possible conditions 1 Open or high resistance on the ground line 2 Hot or neutral polarity circuit Note in order for your UPS to work properly you must have a properly grounded AC circuit If your Site Wiring Fault LED is lit please contact an electrician to properly wire this circuit SITE WIRING Ga Solid Red Chart 1 Solid green AC power is o

Download Pdf Manuals

image

Related Search

Related Contents

  Wireless designer doorbell  Trinitron Color Computer Display - Manuals, Specs & Warranty  Xilence SPS-XP-LP90.MOBI  ESPMod Manual 7  "as。nーe 直管形L ED器具 施工弾 月重  User Manual  Amana NTW4705EW Use & Care Manual  manómetros de muelle tubular con transmisor  MANUAL DE SERVICIO  

Copyright © All rights reserved.