1. NO WARRANTY OR REPRESENTATION OF ANY KIND WHAT SO EVER BELKIN HEREBY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The entire risk of the use results and performance of the software program and documentation is borne by you Should any or all of the product software program documentation or related information goods or services be defective misused unsuitable or cause or give rise to any harm or liability whatsoever you not Belkin or its associates dealers or agents assume the entire liability cost of repair correction or any payment or other remedy whatsoever Furthermore no warranty or guarantee is made 2004 Belkin Components All rights reserved All trade names are registered trademarks of respective manufacturers listed regarding the use or results of the product software program documentation or any related information goods or services in terms of correctness accuracy reliability timeliness or otherwise You use and rely on the program at your own risk The following is the only and exclusive warranty and remedy of any kind Belkin does warrant that the program disks are free from physical defects in materials and workmanship under normal use for a period of one 1 year from the date of purchase as evidenced by a copy of the sales receipt Return the defective disk or documentation wit
2. such programs and files You a single user opening this envelope You or our may use the software on a single central processing unit You may not rent it loan it out or lease it nor use it on a multi user system LICENSE You have the non exclusive right to use the software You are not permitted to copy modify or transfer the software or documentation You may not compile disassemble or otherwise reverse engineer breakdown analyze or modify the software USE AND RESTRICTIONS You are permitted to make backup copies of all the software disks for archival purposes only You must reproduce the proprietary notice set forth on the disks and affix them to all backup copies You are not permitted to use these programs in connection with a computer service or to use the backup copies other than as a replacement for the original copy TERM This license is effective upon acceptance by opening this envelope or in any other way using the enclosed software which will constitute your acceptance of and agreement to this Agreement and is effective until terminated The limited license in this Agreement will be automatically terminated if you fail to comply with any of the Terms and conditions in this Agreement You agree that upon such termination you will immediately destroy all programs and documentation including all copies made or obtained by you SOFTWARE PROGRAM DOCUMENTATION AND ANY RELATED INFORMATION GOODS OR SERVICES ARE PROVIDED WITH
3. 2 CP1270F2 VISION x 2 RT1270 RITAR x 2 Do not dispose of the battery or batteries in fire as they may explode Do not open or mutilate the battery or batteries as released electrolyte is toxic and harmful to skin and eyes A battery can present a risk of electric shock and high short circuit current The following precautions should be observed when working on batteries Remove watches rings or other metal objects Use tools with insulated handles Fully trained personnel should maintain the battery UPS FEATURES AND FUNCTIONS an Se SS ON OFF TEST ON LI S3332235555S2573 SS SS SS Ca CS GS Ga GS GS eS eS OS Os Cs Ge ee ea aaa OVERLOAD REPLACE BATTERY Your UPS features 3 LED indicators which specific s certain functions on your UPS Please review the Front Panel diagram and with this chart as it will assist you in the use of your UPS Condition This condition for the On Battery LED can indicate 1 of 2 problems 1 The UPS is on battery backup and an intermittent audible alarm is on The UPS will begin shutdown procedure Battery is low The UPS will start shutdown The buzzer sounds an audible alarm Flashing Yellow LED with Audible Alarm Beeping ON BATTERY Yellow LED The Fault Overload can indicate 1 of 2 problems There is a problem with the UPS The LED will be lit con
4. INTRODUCTION Thank you for purchasing a Belkin Uninterruptible Power Supply UPS Each year several natural and man made occurrences put the power supplied to your electronics in your home or office in jeopardy At risk are your hardware software and data because of these power problems IMPORTANT SAFETY INSTRUCTIONS Please save this manual It contains important operating instructions and warranty information pertaining to your UPS Please save or recycle the packaging materials The UPS packaging was designed with great care to provide protection during shipment and delivery These materials are invaluable if you ever have to return the UPS for service Damage sustained during transit is not covered under the warranty For installation eThe equipment is operator installable and can be operated by any individual with no previous training e The socket outlet should be located near the equipment and easy to access Other safety instructions The UPS contains electrical voltage which makes it potentially hazardous Qualified service personnel should perform all repairs The UPS has its own internal energy source battery The output receptacles may be alive even when the UPS is not connected When replacing batteries always use the same type and quantity as the previous one Battery type for1O00VA 1250VA BP5 12 BB x2 RT1250F2 RITAR x2 Battery type for 1500VA GP1272F2 CSB x 2 BP7 12 BB x 2 NP7 12 YUASA x
5. Plus Product Installation Browser will appear Please click Install and select the Windows version 4 The Bulldog Plus Installation window will appear Please choose the appropriate software to install 5 Install Shield Wizard will appear onscreen click Next Please read the License Agreement and click Yes 7 On Setup Type ALL Standalone is the default Standalone is for UPS management for your computer only Networking management is for administrators who need to manage several UPSes in a workstation environment You should not install the networking files unless you are technically qualified to use these features For more information on networking please refer to the software user s manual 8 On Choose Destination Folder you have the option to choose the location of where you would like the Software located on your computer We recommend using the default option as shown on screen To use the default option click Next 9 On Select Program Folder you have the option to choose the program folder for your Software We recommend using the default option as shown on screen To use the default option click Next 10 On the Select Language screen please select your language choice 11 The software will now be installed Once completed please click Finish Note Please refer to the help feature found on the Belkin On line Screen To access this screen please click the Belkin shield found in the lower right corn
6. com The UPS continuously beeps Red LED lit Remove the verl iti Overload non critical loads Replace battery Battery failure Contact belkin com CONTACT US Belkin Corporation 501 West Walnut St Compton CA 90220 5221 USA Tel 310 898 1100 Fax 310 898 1111 Belkin Components Ltd Shipton Way Rushden NN10 6GL United Kingdom Tel 44 0 1933 35 2000 Fax 44 0 1933 31 2000 Belkin Ltd 7 Bowen Crescent West Gosford NSW 2250 Tel 61 02 4325 4666 Fax 61 02 4325 4277 Belkin Components B V Starparc Building Boeing Avenue 3331119 PH Schiphol Rijk The Netherlands Tel 31 0 20 654 73 00 Fax 31 0 20 654 73 49 Please visit for information www belkin com battery replacement P74721uk
7. cular jurisdiction shall be interpreted and enforced to the maximum extent allowed in such jurisdiction which the parties acknowledge could mean severing the provision from this Agreement or if allowed enforcing it in a narrower form without affecting the remainder of this Agreement or any other application of such term or provision in such jurisdiction or application of such term or provision in any jurisdiction CAUTION Internal battery voltage is 12V DC The unit is intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants All batteries used are Sealed Lead Batteries Batteries must be recycled TROUBLE SHOOTING POSSIBLE CAUSE On Off Test button not pushed or pushed less than 2 second Battery voltage is too low UPS fault PROBLEM SOLUTION Press the On Off Test button for more than 2 seconds Recharge the UPS at least eight hours Contact service personnel Re plug the power cord Replace or reset the breaker UPS not on LED not lit Power cord loose AC breaker is burned out or tripped Ac utility voltage is too high or too low or black out Battery not fully charged UPS always on battery mode Normal condition Recharge the UPS at least eight hours Remove some un necessary loads Back up time too short UPS is overload Charger fault or other reason Replace battery Contact belkin
8. er on your task bar of your screen Once the Belkin On line screen appears choose help The Bulldog Online Help screen will appear You may use the Contents Index or Search tabs to assist you with your help issues and to get more information on the specific features and functions of the software C User Manual Installation You will need Adobe Acrobat Reader to review the User s Manuals If you do not have the reader please go to www adobe com to download a free version of the software 1 From the Welcome to the Belkin Bulldog Plus Product Installation Browser window locate and choose User Manual s 2 The Bulldog Plus User Manuals window will appear Please move your pointer to the manual you wish to open and click 3 An Adobe PDF file will be opened To save a copy to your hard drive you will need to go to File on your menu bar and choose Save a copy 4 On the Save a Copy window please choose a destination folder for the manual D Uninstall for Windows 98 Me NT4 2000 2003 XP ne are two options to uninstall the Belkin Shutdown oftware Option 1 1 Click the Start icon in the lower left hand corner of your screen and go to the Programs folder Scroll to the Belkin Bulldog Plus folder and choose setup Install Wizard will appear 2 Choose Remove and click Next 3 The Program Files and Audio Files will be checked If they are not please check them Click Next The uninstal
9. h your receipt directly to Belkin for a replacement DISCLAIMER Belkin or its associates will in no event be liable i in any amount for lost profits or special incidental punitive or consequential damages or ii for any claim or damage of any nature or under any theory whatsoever in any amount in excess of the purchase price you paid for the product The warranties and remedies here set forth are exclusive and in lieu of all others oral or written express or implied Some jurisdictions do not allow exclusion or limitation of implied warranties or of liability for incidental damages so the foregoing limitations or exclusion may not apply to you This warranty gives you specific legal rights which vary from jurisdiction to jurisdiction HOWEVER YOU WAIVE SUCH RIGHTS EXCEPT AS EXPRESSLY PROVIDED UNDER THE TERMS AND CONDITIONS OF THIS AGREEMENT TO THE MAXIMUM EXTENT ALLOWED BY LAW ACKNOWLEDGMENT By opening the package on which this Agreement is printed or through which it is visible you acknowledge that you have read this Agreement understand it and agree that this agreement is the complete and exclusive statement of agreement between yourself and Belkin and supersedes any prior agreements oral or written and any other communications relating to the subject matter of this Agreement SEVERABILITY Any term or provision of this Agreement or any application thereof which may be prohibited or unenforceable by law in a parti
10. l need to connect the UPS to your computer The communication port will provide the following features 1 Monitoring charger status Monitoring UPS status Monitoring battery status and condition Monitoring the utility status Use the ON OFF TEST UPS power switch function to schedule UPS for power saving Cre i You may connect the UPS to your computer by choosing either the Serial or USB ports Note Choose one port only Do not connect your computer through both ports Software Installation Installation Optional A To fully utilize the UPS and its software your computer must be able to operate the following operating systems Windows98 ME NT4 2000 2003 XP and have a USB port B Your UPS features the Bulldog Plus Shutdown Software This allows you to protect and save your data should a power outage occur as well as safely shutdown your computer in your absence Please be sure to close out of all applications prior to installing the software 1 To install the software please place the CD into the CD drive of your computer 2 Your computer should autorun the CD If this does not occur go to the Run feature on your Start icon lower left corner on your screen Please enter the CD drive it may be D Upon entering the drive run setup exe to execute the software Should you continue to have a problem please refer to your computer s owner s manual for the correct drive 3 The Welcome to the Belkin Bulldog
11. l procedure will begin 4 Click Finish when complete Option 2 Note Windows2000 2003 XP users choose the Control panel function from your Start icon and then go to step 2 1 Click the Start icon in the lower left hand corner of your screen and go to the Settings icon Go to and choose the Control Panel folder The Control Panel window will appear 2 Locate and click the Add Remove Programs icon The Add Remove Programs window will appear 3 Locate and choose the Belkin Bulldog Plus software Click the Change Remove button on the right Install Wizard will appear 4 Choose Remove and click Next 5 The Program Files amp Audio Files will be checked If they are not please check them Click Next The uninstall procedure will begin 6 Click Finish when complete o TECHNICAL SPECIFICATIONS F6C1000ei F6C1250ei TW RK TW RK 1000VA 1250VA 615W 680W F6C1500ei TW RK 1500VA Capacity 830W INPUT Simulated sine wave 230 vac 10 On battery Back up time OUTPUT 50 60HZ 1HZ Eypica RER 16 hours recover 85 capacity Time ENVIRONMENT Ambient operation 0785 humidity non condensing 0 40 C CONFORMANCE Safety GS CE EMC EN 62040 1 N F S D Dimension 1 46 x 14 96 x 13 13 inches W XH X D 88 x 380 x 333 5 mm Net weight 9 2kg 10 7kg All specifications are subject to change without prior notice BATTERY PHYSICAL 20 24lbs 23 54 lbs STORAGE Storage Conditio
12. nd the battery energy begins to run low the UPS will beep rapidly until it shuts down from a depleted battery or returns to ON LINE normal operation OVERLOAD Continuous alarm When the UPS is overloaded the connected loads exceed the maximum rated capacity the UPS emits a continuous alarm to warn of an overload condition Disconnect nonessential equipment from the UPS to eliminate the overload FAULT 10 Seconds Continuously When the UPS occur fault the UPS emits a 10 seconds continuous alarm to warn of a fault condition Disconnect the equipment from the UPS prior to checking the equipment To Silence Audible Alarm While in battery BACK UP mode push on off test button less than 1 5 seconds to silence the audible alarm This does not work if the UPS is under LOW BATTERY or OVERLOAD condition REAR PANEL A G H CONTENTS BATTERY BACK UP SURGE PROTECTION OUTLETS Only data sensitive equipment such as a computer monitor and external drive should be plugged into these outlets Battery power is automatically provided in case of a power outage Power AC or battery is not supplied to these outlets when the UPS is switched off Do not plug surge protectors or power Strips into the battery back up outlets Note placing on the battery back up outlets should not exceed 80 of the unit s capacity PHONE FAX MODEM PROTECTION The phone fax modem lines are surge protected and provide complete safety for li
13. ne connection INTERFACE PORTS USB amp RS232 The UPS provides both a USB and RS232 port for use with your computer NOTE Choose one port only AC INPUT BREAKER CIRCUIT BREAKER The circuit breaker button will be triggered if an overload condition forces the UPS to disconnect itself from utility power If the button sticks out disconnect nonessential equipment and depress breaker AC INPUT NETWORK PROTECTION This connector is used for protecting the transmission line of Ethernet card from surge noise and spike ACCESSORY SLOT Optional SNMP Slot SURGE PROTECTED ONLY OUTLETS You should have received the following 1 UPS unit 1 Bulldog Plus Shutdown Software 1 USB Cable 1 Serial Cable 1 Phone Line Cable 1 European power cord 1 UK power cord During the AVR Mode the total load that you will be INSTALLATION Note Before installation please inspect the UPS Upon iP receipt Make sure that the UPS is not damaged T Connect to AC Utility Power Connect the AC inlet to utility power via the power cord Charging the Battery For best results charge the battery for 8 hours prior to initial use The UPS charges its battery whenever it is connected to the utility power Plug in Power Devices Plug your devices into the AC outlets on the rear of the UPS To use the UPS as a master on off switch make sure all of the loads are switched on Caution Never connect a laser printer
14. nections The connection will require another length of telephone cable which is supplied Phone Fax Modem Protection IN OUT OUT Note This connection is optional but highly suggested as phone fax modem lines often carry dangerous surges and spikes The UPS works properly without a phone fax modem connection Caution The phone fax modem protection feature could be rendered inoperable if improperly installed Make sure that the telephone line from the wall is plugged into the connector marked IN and the device to be protected is plugged into the connector marked OUT Network Protection IN OUT OUT Connect the Network Protection Lines Connect the network line from the wall to the connector marked IN then connect the device Ethernet card to be protected to the connector marked OUT All equipment must be turned off prior to hardware installation SYSTEM REQUIREMENTS The UPS can be used without the software and can be used with any computer using a monitor or a flat panel screen Also you do not have to have the software installed to utilize the battery backup outlets To fully utilize the UPS and its software your computer must be able to operate the following operating systems 95 98 ME NT4 2000 2003 XP amp Linux amp Higher and have a Serial or USB port SERIAL OR USB COMMUNICATION PORT INSTALLATION OPTIONAL To fully utilize the Bulldog Plus Shutdown Software you wil
15. ns Store the UPS covered and upright in a cool dry location with its battery fully charged Before storing charge the UPS for at least four hours Disconnect any cables connected to the computer interface port to avoid unnecessary drainage of the battery Extended Storage During extended storage in environments where the ambient temperature is 5 F to 86 F charge the UPS battery every six months During extended storage in environments where the ambient temperature is 86 F to 113 F charge the UPS battery every three months Note i mm X Away from water Away from sunlight Away from heat BELKIN COMPONENTS USER LICENSE AGREEMENT Belkin Components Belkin thanks you for choosing one of our products This User License Agreement Agreement contains the terms and conditions under which limited use of the product is licensed to you PLEASE READ THIS NOTICE CAREFULLY DO NOT USE THE SOFTWARE OR PRODUCT UNTIL YOU HAVE READ AND AGREED TO THIS AGREEMENT IF YOU USE THE SOFTWARE AND PRODUCT YOU ARE AGREEING TO THE TERMS AND CONDITIONS SET OUT IN THIS AGREEMENT IF YOU DO NOT ACCEPT THESE TERMS AND CONDITIONS YOU MUST RETURN THE UNOPENED PRODUCT WITH THE DISKS INSIDE TO THE PARTY FROM WHOM YOU RECEIVED IT SCOPE OF USE In this Agreement software means all machine readable software programs and associated files in this package All modified versions of and upgrades or improvements to such programs and all copies of
16. or scanner to the backup outlets of UPS with other computer equipment A laser printer or scanner draws significantly more power when in use than when idle This may overload the UPS Turning on the UPS Turn on your UPS by pressing and holding the On Off Test button for approximately 2 seconds until the ON LINE Green comes on Turning off the UPS Turn off the UPS by pressing and holding the On Off Test button for more than 2 seconds until the ON LINE or ON BATTERY LED goes off To Conduct a Self Test Use the self test to verify both the operation of the UPS and the condition of the battery In normal utility power push the On Off Test button less than 1 5 seconds and the UPS performs a self test function During the self test the UPS operates in back up mode Note During the self test the UPS briefly operates on battery backup power the on battery LED comes on If the UPS passes the self test it returns to on line operation If the UPS fails the self test it immediately returns to on line operation and lights the replace battery LED The loads are not affected Recharge the battery overnight and perform the self test again If the replace battery LED is still on the battery will need to be replaced Connect the phone fax modem lines Connect a single phone fax modem line into the surge protected sockets on the back of the UPS The RJ 11 modular sockets accepts standard single line telephone con
17. tinuously and the unit will sound an audible alarm for 10 seconds 2 Battery is weak or bad the battery needs to be replaced Battery output is drawing more power than the UPS can provide BATTERY REPLACEMENT PROCEDURE Replacement requires removing the battery cover plate on the front of the UPS No tools are needed To replace the batteries 1 Press fastener to remove the battery cover plate on the front of the UPS Fig 1 amp 2 2 Disconnect the insulated connectors from the battery terminals Fig 3 amp 4 3 Remove the battery then insert a new battery pack and push the connectors onto the battery terminals black to black amp red to red Fig 3 amp 4 NOTE There may be a small spark at the battery terminals when reconnecting the connectors This is normal and will not harm you or the UPS FAULT OVERLOAD Replace Battery Red Led Solid Red Flashing Red 4 Close the battery cover Fig 1 Fig 1 Paw a as Fig 3 for Model FeC1500eiTW RK 07 Model F6C beiTW RK F6C1250ei TW RK ALARMS BELKIN USERS MANUAL BELKIN TOWER RACK SERIES UPS F6C1000eiTW RK F6C1250eiTW RK F6C1500eiTW RK BATTERY BACK UP Slow Alarm When in the UPS is in battery BACK UP mode the On Battery Yellow LED illuminates and the UPS sounds an audible alarm The alarm stops when the UPS returns to normal ON LINE operation LOW BATTERY Rapid Alarm When the UPS is in battery BACK UP mode a