Home

Bayer HCBT-800 User's Manual

image

Contents

1. 800 High Capacity Seed Treater Installation and Operation Manual Advanced Seed Treatment Technology saver Bayer CropScience This page intentionally left blank 3 0 Table of Contents The following HCBT manual contains installation operation parts list and technical drawing information Please read and understand these instructions completely before proceeding to install and operate the equipment Bayer CropScience reserves the right to change specifications models components or materials at any time without notice For further detailed information contact the Bayer CropScience technical representative for your area Please have this operation manual available when contacting Bayer CropScience Contact Information Bayer CropScience 4895 12th Avenue East Shakopee MN 55379 800 634 6738 FAX 952 445 8282 www bayercropscienceus com General categories 4 0 Introduction 5 0 Installation gt 8 0 HCBT Drum Operation 10 0 Seed Calibration 12 0 CBP Tank Installation 14 0 CBP Tank Calibration 17 0 Treating Operation 21 0 Maintenance gt 22 0 Guidlines for Treating gt 23 0 Slurry Preparation 24 0 Calculations 26 0 Liquid Product Worksheet 27 0 Powder Woksheet 28 0 Guidelines for Successful Treating 30 0 Limited Warranty 2008 Gustafson Equipment RF M 013008 HCBT 579
2. 46 50 54 59 63 68 72 76 81 850 45 49 53 58 62 66 70 74 78 _ 800 45 49 52 56 60 64 68 72 7 750 44 48 52 55 59 62 66 70 73 __700 44 47 51 54 57 61 64 68 71 x 59 62 65 69 EBENE 500 42 44 47 49 52 54 56 59 61 450 41 43 46 48 50 52 54 57 59 350 40 42 44 45 47 49 51 52 54 300 40 41 43 44 46 47 49 50 52 250 39 41 42 43 44 45 47 48 49 200 39 40 41 42 2 MM RATE OZ CWT 2 H NS WY L LU LL U Continued 15 0 CBP Tank Calibration continued Adjust the Liquid Flow 1 Disconnect the liquid treatment tubing from the elbow fitting under the HCBT inlet hopper and place it in a calibrated beaker to measure the liquid seed treatment output 1 2 OD Chemical Pump Port 2 Turn the HCBT Pump AGITATION switch to ON HCBT AGITATOR Control Switch 3 Hold the HCBT Pump switch to MANUAL Measure the treatment output after one minute Release the Pump switch to turn the pump OFF Record your volume measurement Pour the liquid seed treatment back into the premix tank 4 If you do not get the desired volume in one minute change the valve setting up or down and repeat step 3 above Repeat this process until the output of the liquid seed treatment product is
3. BAYER CROPSCIENCE BE LIABLE TO CUSTOMER FOR ANY INCIDENTAL CONSEQUENTIAL SPECIAL OR PUNITIVE DAMAGES REGARDLESS OF WHETHER ARISING IN CONTRACT STRICT LIABILITY OTHER TORT OR OTHERWISE THE EXCLUSIVE REMEDY OF CUSTOMER FOR ANY AND ALL LOSSES INJURIES OR DAMAGES RESULTING FROM THE SALE USE OR HANDLING OF THE GUSTAFSON APPLI CATION EQUIPMENT WHETHER IN CONTRACT WARRANTY TORT NEGLIGENCE STRICT LIABILITY OR OTHERWISE SHALL NOT EXCEED THE PURCHASE PRICE PAID OR AT BAYER CROPSCIENCE S SOLE ELECTION THE REPAIR OR REPLACEMENT OF APPLICATION EQUIPMENT No shipment of Gustafson application equipment or any portion thereof is returnable by customer unless such shipment or portion thereof is defective in one or more of its components In the event that customer believes that the Gustafson application equipment is defective written notice must be provided to Bayer CropScience by customer within one 1 year after the date of delivery of the equipment Failure to provide such notice shall constitute customer s irrevocable acceptance of the Gustafson ap plication equipment and waiver of any claims for errors deficiencies or imperfections therein Any attempt to return a shipment of Gustafson application equipment or portion thereof for any other reason after the expiration of the time period set forth herein shall be an ineffective rejection of such Gustafson application equipment and customer shall be invoiced by Bayer CropScience and shall pay th
4. hopper flow door Seed Flow ux 2 6 Weigh the seed that has gone through in one minute Write down your time and calculate the output per minute Use the following example with your choice of weight per Y minute in place of the 600 pounds Example 600 pounds discharge in one minute If 600 pounds is an acceptable capacity leave the hopper flow door in the position you have set If the capacity is too high then reduce the opening on the hopper flow door and calibrate again If the capacity is too low then increase the opening of the hopper flow door and calibrate again b i i P B 4 Repeat steps 4 6 until you achieve your required feed Ae Lc capacity Hopper Flow Door handle 12 0 CBP Tank Installation 1 Mount the Metering Ball Valve Assembly to the CBP 30 Tank stand with the supplied U Bolts Tighten to secure the mounting to the tank stand Metering Ball Valve Mounting CBP 30 Tank 2 Connect 1 2 OD tubing on CBP 30 Tank Chemical Pump port to the bottom Port of the metering ball valve Connect 3 8 OD tubing from the CBP 30 Tank metering ball valve top port to the elbow fitting under the HCBT inlet hopper 3 8 OD Tubing To Treater d d 3 E 1 2 OD Tubing From Pump CBP 30 Tank Metering Ball Valve aD A Continued 1 2 OD Pump to Ball Valve 13 0 CBP Tank Installation cont
5. of the slurry mix PER CWT PER TANK 00 oas nem o x em oe oa x em wise e o x os po w on TOTAL X CW TS FLOZ 128 SLURRY PRODUCT CALCULATIONS PRODUCT EN TANK X CWTS FLOL 128 FLOZ 128 E e maj a x em uisus WATER X GWTS FLOL 128 FLOZ 128 TOTAL X CW 5 FLOZ 128 SLURRY PRODUCT RA CALCULATIONS PRODUCT PER CWT PER TANK h as nem o x ene o x eme x eme h os ne we x ewes a o TOTAL X CW 5 FLOZ 128 SLURRY GAL Worksheet for use with powders as part of the slurry mix 27 0 PROC UCT DRY RATE LIQUID RATE CALCULATIONS PER LAT PER LIDUID 126 FLOAGAL DR Y 16 27 0 LIQUID DRY PER TANK PER TANK T TOTAL FL Oz 128 SLURRY WATER LIQUID RATE CALCULATION PER LIQUID PER PER LI UD 128 ORY 16 PER TANK 88 57 e EEmMD o __ 9 59 ooo xm e a ___ m af e 00 o AE ee __ mu ___ LATS FL Of 126 m WATER TOTAL SLURRY 28 0 Guidelines GUIDELINES FOR HANDLING SEED APPLIED PRODUCTS AND RECOMMENDED EQUIPMENT INSPECTION AND MAINTENANCE PROCEDURES The following are general recommendations for handling seed applied products equipment inspection and main
6. the pump and lines after use may damage the equipment and void any warranties expressed or implied It will not damage the pump to run it dry or with the valves in the closed position 22 0 Guidelines for Treating Follow these guidelines for a more successful operation 1 Avoid spouting seeds at an angle into the treater A surge hopper installed above the treater is recommended 2 To shut off seed flow use the slide gate on the treater or on the holding bin 3 Treat only clean seed Remove dust at the holding bins and at the treater inlet 4 Keep the weighpan tripping quickly to achieve a constant flow of seed and liquid seed treatment into the coating chamber 5 Keep the liquid seed treatment tank lid closed during operation to keep out foreign objects 6 In all hose lines avoid dips and valleys where liquid may settle and not drain after treating Keep your hoses as close to vertical as possible 7 Protect supply hoses and bypass return hoses from abrasion sunlight and being dislodged with PVC pipe or a similar material 8 Adjustment to the liquid seed treatment flow should be made with the bypass adjust ment valve located at the pump Do not place valves filters or anything that may restrict liquid flow at any point on the treatment supply hose 9 When using a premix tank be sure the bypass return hoses reach down into the liquid treatment Do not cut them too short If the hose is above the liquid level in
7. 16 OZ AI CWT To calculate OZ AI FL OZ flowable or liquid Pounds Al Gallon x 16 128 OZ AI CWT To calculate OZ AI CWT Rate FL OZ CWT x OZ AI FL OZ OZ AI CWT To calculate OZ Al for powders Rate x active OZ AI CWT Approximate water displacement 1 dry OZ displaces 1 FL OZ Ag strep formula Go to Ag Strep Label under mixing instructions Add concentration per gallon to get desired concentration per gallon of water slurry OZ Ag Strep per gallon divide by 128 OZ of Ag Strep per FL OZ multiply by slurry rate per CWT rate Ag Strep per CWT Pounds of seed number of trips pounds per trip Ounces of chemical per 100 pounds of seed x 29 6 CC total CC of treatment per 100 pounds of seed Continued 25 0 Calculations continued 12 Total CC of treatment per 100 pounds of seed 100 pounds of seed per pound 13 CC per pound of seed x pounds per trip CC per trip or chemical cup size CCs 14 Trips per minute x pounds per trips pounds per minute 15 Pounds per minute x 60 minutes pounds per hour 16 Pounds per hour bushel weight capacity in BU hour FREQUENTLY USED CONVERSIONS Liquid Measure 1 cup 8 ounces 1 pint 16 ounces 1 quart 32 ounces 1 gallon 128 ounces 1 ounce 29 6 Millilitre cubic centimeter Dry Measure 1 pound 16 ounces 1 ton 2 000 pounds 1 metric ton 2 204 pounds 26 0 Worksheet with liquid product as part
8. KB 4 0 Introduction Gustafson s HCBT 800 continuous flow treater is designed for treating many crops including soybeans wheat rice and peas Operators can treat from a seed holding bin or from bulk seed bags USE CAUTION Always use caution and common sense when working with any chemical Read the product label and MSDS carefully and follow their instructions exactly as described Installation 1 Provide a mounting surface which is a floor or frame strong enough to support the HCBT and the weight of the seeds you will process at any one time Consider also the weight of any conveying system for input and discharge as well as the weight of containers at both ends of the process Your input feed and output collector should be of equal Capacity 2 Secure to the mounting surface a 2 X 32 angle iron directly in front of the frame on the discharge end of the HCBT The angle iron is used to keep the HCBT from moving forward while allowing the angle of the machine to be changed for various capacities and crops Treater Discharge End 2 AMELE IRON DJL Continued 6 0 Intstallation continued 3 Use a chain hoist or jack to lift the Inlet End of the HCBT approximately 6 4 Insert the Lift Rod into the frame hole with the head of the bolt positioned up 5 Thread the 34 10 SQ Adjuster Nut from the bottom of the bolt up to allow approximately 4 of Space from the bottom of Adjuster N
9. ant flow and com plete product removal when the lines are drained Electronic and CBT Treating Systems Conduct on the go calibration checks frequently by checking the amount of product being pumped from the closed calibration cylinder versus the product delivery rates that the computer is indicating GLCPS systems rely on peristaltic pump hose integ rity wear and tear on it will affect the calibration Periodic inspection and recalibra tion should help improve calibration accuracy Make routine loss in weight calibration inspections when product supply tanks are mounted on weighing scales While the machine is running a loss in weight should be observed The elapsed time for this weight loss can be used to cross check accuracy against the rate per minute displayed on the computer screen On the CBT 200 batch treaters inspect the 20 l batch weighing tank used to receive and dispense any products If an accumulation of product is visible it should be re moved and cleaned 30 0 Warranty LIMITED WARRANTY LIMITATION OF LIABILITY amp CLAIMS Bayer CropScience warrants that the Gustafson application equipment shipped hereunder shall be free of defects in materials or workmanship for a period of one 1 year from the date of delivery BAYER CROPSCIENCE MAKES NO OTHER WARRANTY INCLUDING WITHOUT LIMITATION ANY WARRANTIES OR MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE WHETHER EXPRESSED OR IMPLIED IN NO EVENT SHALL
10. correct When you liquid output per minute is correct the calibration process is complete CBP 30 Tank Metering Ball Valve Continued 16 0 Calibration continued 5 Connect the liquid treatment tubing to the elbow fitting under the HCBT inlet hopper 1 2 OD Chemical Pump Port 6 Hold the HCBT Pump switch in MANUAL to deliver treatment product to the treater This jog switch will reset to OFF when released The system is calibrated Treating may begin HCBT Pump Control Switch 17 0 Treating Operation WARNING Do not leave the machine unattended while treating seed The HCBT is NOT an automatic machine Using the settings for seed feed rate page 11 0 and liquid flow adjustment page 15 0 1 Turn the Control Box Panel drum switch to ON Control Box panel Control Box panel HCBT AGITATOR Control Switch Continued 2 Turn the drum rotation switch to F TREAT 3 Turn the HCBT Pump AGITATION switch to ON Treating Operation continued Pump Control Switch Drum Speed Dial 4 Turn the pump switch to AUTO The pump uses the Proximity Sensors inside the inlet hopper to indicate when liquid treatment dispersion to the treater should begin and will stop the pump as soon as the seed level in the seed hopper is lower than the proximity sensor The Product Flow Light below the Drum Speed Dial will turn on to indicate that seed is flowing past the sensors Produc
11. e invoice in full including any storage freight or other costs for returned Gustafson application equipment or any portion thereof Upon notice to Bayer CropScience that the application equipment is defective Bayer CropScience shall have the right to send a representative to customer s facility or inspect the equipment after having received it from customer If Bayer CropScience determines that any Gustafson application equipment is defective Bayer CropScience shall replace such application equipment at its expense lf Bayer CropScience disagrees with customer s conclusion that the Gustafson application equipment is in any way defective or if the defect or damage was caused directly or indirectly by customer s action or inaction customer shall be charged for all costs associated with sending the equipment or replacement parts to customer Notwithstanding the foregoing the limited warranty contained herein does not apply to the following Maintenance This includes but is not limited to such things as cleaning flushing systems corrosion prevention mechanical or electrical adjustments or repairs which become necessary through normal wear and tear or periodic maintenance such as lubrication and gear or variable speed oil changes Service and wear items This includes but is not limited to the replacement of belts drive chains sprockets fasteners bulbs fuses ball bearings bushings and other electrical or mechanical compon
12. e the amount of product that can splash up on the sidewalls and tops of those tanks If compressed air is used to purge lines after product transfer use the minimum amount of air pressure necessary and make sure the work tank is vented to reduce product splashing After products have been transferred to their respective work tanks resume mechani cal agitation Do not allow the liquid level in work tanks to be pulled below two thirds capacity so that the products and or blends have minimal exposure to air and do not dry and or cake prematurely Guidelines 19 0 General Equipment Check filters daily at least once Clean rinse off as necessary The filter assemblies are intended to keep agglomerates plant debris and other foreign substances from going through the system and plugging lines If an accumulation of material is found the filter basket should be removed and rinsed free of the debris Clean pump and product lines frequently to avoid an accumulation of product buildup over time Avoid low spots or bows on hoses and supply lines where products may have a tenden cy to accumulate and or settle If the treating system is being shut down for a weekend or more fill the work tanks to their maximum level and flush any product from the lines to avoid any potential product settling Product supply lines running from a pump to the application equipment should be installed so they run laterally and up to the treater to ensure const
13. ents that have a useful life based on how much these components are used Lack of service This includes but is not limited to damage attributable to failure to perform maintenance in services in accordance with the manufacturer of the component Damage This includes but is not limited to damage resulting from negligence improper installation the installation process improper or incorrect wiring corrosion construction welding or freight damage Controls Systems without Bayer CropScience supplied control packages or systems using other controls are not covered under the terms of this warranty TRAINING CALIBRATION ASSISTANCE AND SERVICE CALLS Bayer CropScience trained employees may assist in the training and calibration of equipment Due to factors such as temperature variations seed flow changes improper mixing procedures and other factors that are out of Bayer CropScience s control Bayer CropScience does not accept responsibility for the calibration of the system Electronic controlled seed and chemical proportioning systems Infield training and calibration assistance of up to 15 hours or 1 trip to the purchaser s location is included in the price of qualified electronic controlled seed and chemical proportioning system Additional hours will be billed to the purchaser at 60 per hour plus travel expenses for units in the continental United States Electronic controlled seed and chemical proportioning systems purchased outside o
14. f the continental United States 60 00 per hour portal to portal will be billed to the purchaser Service calls for non warranty items will be charged at 60 00 per hour portal to portal plus expenses All other standard application equipment Service calls for non warranty items will be charged at 60 00 per hour port to port This page intentionally left blank BN Advanced BAYE R B ayer Crop S cience a XR Technology Bayer CropScience 4895 12th Avenue East Shakopee Minnesota 55379 USA www bayercropscienceus com
15. inued 7 Fill the CBP 30 Tank with Liquid Seed Treatment Product through the Tank Lid NOTE Read and understand the liquid seed treatment product label and material safety data sheet MSDS Follow all instructions for use handling precautions protective equipment and other instructions listed on the label and the MSDS Tank Lid 8 Plug in the CBP 30 Tank Agitation motor 110 power cord to the 110v female connector on the HCBT Control Panel 30 9 Turn the AGITATOR Switch to the ON position light will go ON 10 Turn the PUMP Switch to MANUAL and HOLD light will go on to deliver treatment product to the treater This jog switch will reset to OFF when released Installation is complete you are now ready to test the Pump HCBT Pump Control Switches 14 0 CBP Tank Calibration Metering Ball Valve Setting Example refer to chart at bottom of page Your seed output from page 11 0 is 600 pounds per minute Assume you are using a product that can be applied ready to use at a rate of 6 ounces per 100 pounds of seed Look at the bottom of the chart and find 6 ounces Follow the numbers up the chart to the point where it intersects with 600 pounds per minute At 6 ounces per 100 pounds of seed 600 pounds per minute 54 These valve settings are approximate and are a guide to use as a Starting point CBP 30 Tank Metering Ball Valve 900
16. nd to continue using and that you have diluted with water may settle in the CBP tank so continue to operate the agitator If the machine will not be used for a long time drain the premix tank refer to page 21 0 maintenance Tank Lid 21 0 Maintenance 1 Disconnect the liquid treatment tubing from the elbow fitting under the HCBT inlet hopper and place it in a secondary container 2 Hold the HCBT Pump switch to MANUAL and Completely empty the CBP 30 Tank This jog switch will reset to OFF when released 3 Fill the CBP 30 Tank with clean water mixed with ammonia or a mild detergent or a cleaning solution recommended by the manufacturer of the treatment product Repeat step 2 to flush the entire system lf the applicator is going to be stored in subfreezing tempera tures flush with alcohol to prevent freezing which will cause pump damage Save all rinse water and use for next treatment or dispose of properly by following the MSDS sheet If amore thorough cleaning is necessary the metered pump kit is easily disassembled and reassembled For winter storage disconnect and drain all hoses to ensure that no components will freeze and cause damage Clean the drum and seed chamber and spray with light food grade oil to help prevent corrosion Store the treating unit indoors to extend the life and appearance of the unit NOTE Failure to clean your treater properly or failure to com pletely drain all liquid from
17. nued 3 Once the drum is running counterclockwise turn the drum rotation switch to OFF Control Box panel 4 Turn the Drum Rotation Switch to R CLEAN OUT The drum should be running clockwise Drum Rotation Control Box panel 5 Turn the Drum Switch to OFF then the Drum Rotation switch to the OFF position Testing the HCBT is complete Control Box panel 10 0 Seed Calibration Determine the feed rate of seed You will need a watch or stopwatch scale calibrated beaker and a collection bin for the Calibration process 1 Close the HCBT Hopper Flow Door Handle mM p Hopper Flow Door handle 2 Then open the HCBT Hopper Flow Control Handle about 1 3 4 3 Position your Seed Source i e bulk bag conveyer with holding bin holding bin etc with an OPEN CLOSE seed gate above the HCBT Inlet Hopper x d i sto Seed Source needs to have an OPEN CLOSE Seed Gate to control the seed flow to the HCBT Inlet Hopper Continued 11 0 seed Calibration continued F 4 Have a collection bin ready to catch seed from the HCBT Hopper Housing Open the HCBT hopper flow door Pull UP on the lip and then let it DOWN Use the OPEN CLOSE seed gate on the seed source bin above the HCBT inlet hopper to start the seed flow 5 Time the seed flow for one minute Close the OPEN CLOSE seed gate on the seed source bin Then close the HCBT
18. t Flow Light Fine tune the drum rotation by increasing or decreasing the Drum Speed Dial to get the best possible coverage and the maximum volume WARNING Never stop the drum full of seed unless it is an emergency Staring the drum when it is full of seed can cause overloads that may stress electrical components Clean out as much seed as possible BEFORE restarting the drum Continued Treating Operation continued 1 When seed flow stops turn off the Pump The Product Flow Light below the Drum Speed Dial will turn off when seed has stopped flowing past the sensors Product Flow Light Pump Control Switch 2 When a few seeds remain in the drum turn the control box Drum Switch to OFF Control Panel Continued 20 0 Treating Operation continued 3 When drum rotation stops turn the Drum Rotation Switch to R CLEAN OUT and turn the Drum Switch to ON and run the drum until it is empty Control Box panel 5 Turn the Drum Switch to OFF then the Drum Rotation switch to the OFF position Wait for the drum to stop then switch the drum rotation to F TREAT for the next treating job Before treating other crops or varieties ensure all switches are set to the OFF position Inspect the entire seed system and treater Be sure it is clean to avoid contamination of other seed sources Control Box panel If the HCBT will not be used for a while any liquid treatment you inte
19. tenance on most Gustafson application equipment used in commercial treating facilities There may be situations that occur outside the scope of this document that can be addressed on a case by case basis by contacting the appropriate Bayer Crop Science personnel Products Flowables and Custom Blends with Flowables In many cases custom bulk blends of some products are provided to our customers The following are general recommendations for handling the liquid flowables products and the blends made from them Products and blends are best utilized when stored between 40 90 degrees Fahrenheit Exposure to temperatures above and below this range for prolonged periods of time may cause the products and or blends to stratify in their containers Thoroughly mix all liquid products prior to use and prior to transferring into work tanks Bulk shuttles are equipped with top and bottom ports to allow for recirculation agitation and returnable kegs and drums have manual stirring devices inserted 15 20 minutes of recirculation is recommended for 200 and 400 gallon bulk shuttles If the system is not set up for recirculation agitation then a mechanical agitation system will need to be installed On returnable containers manually rotate a minimum of 25 30 times clockwise and then a minimum of 25 30 times counterclockwise Where products and or blends are transferred to work tanks any mechanical agitation devices in those tanks should be shut off to reduc
20. the premix tank it can cause excessive foaming 10 Use tap water at normal temperatures when mixing flowables Do not use hot water 23 0 Slurry Preparation This is the recommended sequence for adding products to produce your slurry Start with approximately 2 3 to 3 4 of the total water volume Add dyes and or colorants Add water soluble products such as Orthene or Ag Strep Add wettable powders such as Guacho 75 ST or Lorsban 50 SL Add any water dispersible granular products Add water based flowables Add emulsifiable concentrates or concentrated emulsion products Add oil based flowables such as DiPel amp 4L Polymeric and or coatings additives are added last special rules may apply j fe 14 gt oce x ono 10 Use the water balance for container rinsing Note The 8 amp 8 Rule says 8 ounces of powder will displace 8 fluid ounces of water 24 0 Calculations 424i Al Active Ingredient BU Bushel CC Cubic Centimeter CWT 100 pounds OZ Ounces To convert rate per CWT to rate per bushel multiply the rate per CWT by decimal point bushel weight Example 4 oz per CWT on wheat 2 4 OZ BU 4x 60 2 4 To convert rate per bushel to rate per CWT divide rate per bushel by decimal point bushel weight Example 2 4 OZ per bushel on wheat 4 OZ per 2 4 x 60 4 OZ per CWT To calculate part per million PPM OZ AI CWT 0016 PPM To calculate OZ AI CWT from PPM PPM x 00
21. ut to the lower end of the bolt 6 Position the Lift Support below each bolt Lower the HCBT to allow some weight to be on the Lift Support Position the Lift Support parallel to the treater frame Completely lower the HCBT onto the Lift Support Bolt or weld the Lift Support to the floor Lift Support 7 05 Intstallation continued Place the Inlet Hopper on the treater and bolt in place 8 Once the treater is permanently mounted have the machine wired by a qualified electrician The treater requires 220 VAC 60 HZ 19amps single phase The treater has a male plug directly wired to the control box The female end of the plug should be wired as shown gt CROLINE 240 60 Hr CF 9 Ensure that your delivery and discharge system can handle the product flow you select Estimated capacities for the treater Soybeans 800 pounds per minute Wheat 400 pounds per minute Rice 400 pounds per minute Drum Operation 1 Turn the Control Box Panel drum switch to ON Control Box panel 2 Turn the drum rotation switch to F TREAT Control Box panel Note When facing the discharge end of the drum it should be rotating counter clockwise If the drum is running clockwise turn the drum switch OFF disconnect the power source and rewire the female plug reversing the 120vAC supply wires refer to stp 8 on page 7 0 Drum Rotation Continued HCBT Drum Operation conti

Download Pdf Manuals

image

Related Search

Related Contents

Kensington Pocket KeyPad Calculator  MTP850/MTP850 S/MTP850 FuG TETRA Portable Terminal – Basic  Sharp UX-CC500 All in One Printer User Manual  preliminary  Labels Platform Spezial Fax-Bestellung 96501408  Kelvinator JS4BE-048KA Use and Care Manual      User`s manual - positivID Identity Systems Ltd    