Home

Aube Technologies TH111GFCI-NP User's Manual

image

Contents

1. Test Reset F bid s QO Heating indicator H PRE PROGRAMMED SET POINTS Comfort temperature L Economic temperature Temperature setting buttons INSTALLATION Parts included One 1 TH111GFCI NP 120 VAC thermostat Two 2 6 32 screws Four 4 Solderless connectors for copper wire One 1 Temperature sensor with a 15 foot extension TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK KEEP AIR VENTS OF THE THERMOSTAT CLEAN AND OBSTRUCTION FREE This thermostat should be installed by an electrician or experienced technician The thermostat must be used with a circuit breaker or fuse This thermostat was designed to control floor electric heating systems The resistive load must not exceed 2000 watts 120 VAC 16 7 A The thermostat is equipped with a ground fault circuit interrupter GFCI and therefore the isolation of the line and load is required for operation The polarity of line connection must be respected During a ground fault only the current in the black wire of the load will be cut off from the 120 V line Connect thermostat as shown on diagram 1 CONNECTING WIRES AND MOUNTING THERMOSTAT Connect the rear thermostat wires to the power supply and to the load using solderless connectors for copper wires See schematic diagram Push the excess wire back into the electrica
2. in lieu of all other warranties obligations or liabilities expressed or implied by the company In no event shall AUBE technologies inc be liable for consequential or incidental damages resulting from installation of this product Some states or provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above exclusions or limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state The defective product and the original sale receipt must be returned to the original dealer or shipped pre paid insured and addressed to e Aube technologies inc Customer Service 705 Av Montrichard e Iberville Quebec J2X 5K8 If you have any questions concerning the installation or programming of this product please call our technical assistance at 450 358 4600 for the Montreal area or 1 800 831 AUBE for outside area Monday to Friday between 8 30 AM and 5 00 PM Eastern time 09 03 01 720 111715 B 2 2
3. aube ad technologies MODEL TH111GFCI NP 120 VAC SUMMARY OPTIONS SELECTION At the back of the thermostat there is one selection switches to set at your preferences Temperature in C or F TO SET TEMPERATURE Press on 4 or Y once to see setpoint temperature appear on display Every subsequent press will change the setpoint temperature by one degree TO RECORD THE COMFORT SETPOINT TEMPERATURE Select chosen setpoint temperature by using or w button Press on 3 button 2 to 3 seconds until icon appears on display TO RECORD THE C ECONOMIC SETPOINT TEMPERATURE Select chosen setpoint temperature by using or Y button Press on C button 2 to 3 seconds until icon appears on display TO RECORD THE tm VACATION SETPOINT TEMPERATURE To program the Vacation temperature select the desired degree using the 4 w buttons and press on the X and buttons simultaneously until the ty icon is displayed app 3 seconds CHECKING GROUND FAULT CIRCUIT INTERRUPTER GFCI Adjust the setpoint temperature until heating indicator flames appears on display Press TEST button The test is conclusive if the warning light GFCI on thermostat is ON and power to the load is cut off flames remain on display though If these events do not occur check the installation Press on RESET but ton to reset the GFCI aaa ea Warning light of the GFCI Test button of the GFCI GFI Floor or set point temperature
4. change the setpoint temperature by one degree e Recording setpoint temperature for COMFORT ECONOMIC and th VACATION settings By recording the setpoint temperatures you will be able to go from the X setting to the or ti setting by simply pressing the x or button or ig and q for tm e Recording a setpoint temperature for the COMFORT setting Select chosen setpoint temperature by using and w buttons pressing on the button 2 to 3 seconds until icon appears on display the instructions The warning light GFI l Recalling stored setpoint temperatures C 32 F or higher than 60 C 140 F Also the heating indicator will be e Recording a setpoint temperature for the C ECONOMIC setting Keep pressing on the button 2 to 3 seconds until icon appears on display l l i Select chosen setpoint temperature by using and w buttons l l e Recording a setpoint temperature for the m VACATION setting w buttons and press on the When power is applied for the first time To program the Vacation temperature select the desired degree using the X and buttons simultaneously until the ti icon is displayed app 3 seconds I NOTE When the temperature setting used is X or or ti you can still use the a or w buttons to change the setpoint temperature without changing the recorded temperature 34 or button or both 3 CHARACTERISTICS i Model l Supp
5. he load A v e N l CHECKING GROUND FAULT CIRCUIT INTERRUPTER GFCI Adjust the setpoint temperature until heating indicator rid display Press TEST button The test is conclusive if the warning light GFCI on the thermostat is ON and power to the load is cut off If these events do not oA occur check the installation Press on o RESET button to reset the GFCI If the GFCI test fails Test Reset must be in heating mode to carry out the test heating indicator ON monthly If the test fails cut off the electric power to the heating system and return the thermostat to your supplier for verification If the warning light off power to the heating system and have an electrician verify the installa tion OPERATION The thermostat has 4 different buttons to control the floor temperature The 4 and buttons increase or decrease the setpoint temperature The X and C buttons are used to store and recall two temperature settings e Default values To erase the recorded setting temperatures 36 and and replace their va lues by the default ones X 28 C 82 F and 18 C 64 F press the but ton while pressing and releasing the RESET button Then release the button e Setting a setpoint temperature Press once the or w button to see the setpoint temperature on display Every subsequent press will
6. l box to prevent interference withthe thermostat Secure the thermostat using two 2 6 32 screws 1 1 4 inches long Once the thermostat is properly installed return power to heating system 120 V LINE 120 VAC 60 HZ NO0T10 LOAD 2 CONNECTING TEMPERATURE SENSOR WIRE Connect the sensor wire to the two lower screws of the terminal block at the back of the thermostat no polarity need to be respected The wire must pass outside the electrical box and follow the wall down to the floor The sensing probe should be placed in a representative heat area for maximum system perfomance The sensing probe should be centered between the wires in the mat The probe wire cannot cross any heater wires and the temperature sensor 2 2 z OOO0000 120 VAC 4 FAHRENHEIT TO APPEAR ON DISPLAY Set the temperature switch at the back of the thermostat to C or F at your preferences 720 111715 B 1 2 To power up thermostat aube the display must show the time 00 00 the floor temperature and the manual mode icon m Other information might show up on the display if installa tion is defective or does not comply with pr y li Lu NN OE must be off The message LO or HI will appear on the display if the temperature sensor is defective or the temperature is below 0 Q present on display and the relay will be closed current going in t
7. ly Load i Power i Ground fault circuit interrupter GFCI Approvals Once stored the setpoint temperatures can be recalled simply by selecting the and for tm setpoint TH111GFCI NP 120 VAC 120 VAC 50 60 Hz 16 7 A maximum resistive only 2000 watts 120 VAC Class A 5 MA TRIP LEVEL CSA C US comes on during normal operation cut Keep i Display range Check the load wires The thermostat i Storage p The GFCI test should be carried out i recipiam I Default setting 0 to 60 C 32 F to 140 F 5 C to 40 C 40 F to 104 F 28 C 82 F 18 C 64 F 20 C to 50 C 4 1 2 F 0 5 C 1 F 2000 W Setting range X Default setting F to 120 F Temperature regulation WARRANTY call customer service or AUBE TECHNOLOGIES INC ONE 1 YEAR LIMITED WARRANTY This product is warranted against material defects and workmanship in normal use for a period of one year from the date of the original purchase from authorized dealers During this period AUBE technologies inc will repair or replace the product with a new or of equivalent quality at AUBE S option without charge any product proven defective in normal use Warranty does not cover transportation costs Nor does it cover a product subjected to misuse or accidental damage This warranty does not cover the cost of installation removal or reinstallation This limited warranty is