American Standard One Spread Lavatory Faucet 2064.408 User's Manual
Contents
1. KE f VVS V5 S S WASTE amp OUTLET S S 2 S S S S S S W C P TRAP V7 I 2 soy SERVICE E To change direction of handle rotation proceed as follows Turn valve to OFF position m Thread counter clock wise HANDLE BASE 1 to remove HANDLE ASSEMBLY 2 from ESCUTCHEON BASE 3 u Use a flat blade screw driver to remove SPRING CLIP 4 2 Lift STOP WASHER 5 turn 90 and replace Replace SPRING CLIP 4 Reinstall HANDLE ASSEMBLY 2 E f spout drips operate handles several times from OFF to ON position Do not force handles turn only 90 VALVE 5 4 1 6 CARE INSTRUCTIONS DO SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER DRY WITH A SOFT COTTON FLANNEL CLOTH DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE M968850 5 SpeedConnect Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the down position e Follow CABLE ADJUSTMENT PROCEDURE If Stopper does not raise up fully or sink drains too slowly e Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper e Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain e Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode CABLE ADJUSTMENT PROCEDURE Disconnect the Cable from the Drain by threading the Cable Con
2. outward If the Cam Cap does not snap into place then rotate DRAIN the Cam to make sure it is fully inserted Fig K m Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Unlocked Mode Troublingshooting Guide to complete installation Stopper will be in Unlocked mode and removable INSTALL CAM CAP M968850
3. 2 and hand tighten Fig A Your new POP UP DRAIN installation is now complete Fig B Note Tailpeice on pop up drain is 1 1 4 O D Fig B 1 1 CHECK OPERATION OF POP UP E Operate LIFT KNOB 1 to verify that STOPPER 2 opens and closes Note If STOPPER 2 does not open and close properly then refer to the troubleshooting section of these instructions 1 2 MAKE WATER SUPPLY AND WASTE CONNECTIONS NOTE FLEXIBLE SUPPLIES OR BULL NOSE RISERS MUST BE PURCHASED SEPARATELY m Connect water supply to FAUCET 1 with 1 2 IPS FLEXIBLE SUPPLIES 2 or 3 8 0 D BULL NOSE RISERS 3 Use adjustable wrench to tighten connections COUPLING NUT m Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper length 3 M968850 1 4 CHECK DRAIN CONNECTIONS 1 3 TEST INSTALLED FITTING With HANDLES 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks m Remove AERATOR 3 Operate both HANDLES 1 to flush water lines thoroughly Replace AERATOR 3 Operate POP UP KNOB 5 and fill Sink with water Check that DRAIN STOPPER 4 makes a good seal and retains water in Sink If STOPPER 4 does not seal properly please refer to Troubleshooting Guide in these instructions Release POP UP KNOB 5 down and check all drain connections and P trap for leaks Tighten if necessary
4. Installation Instructions ONE 2064 801 SPREAD LAVATORY FAUCET with EverClean Finish amp SpeedConnect Drain Congratulations on purchasing your American Standard faucet with EverClean finish and SpeedConnect drain two features found only on American Standard faucets Certified to comply with ANSI A112 18 1 EverClean Finish SpeedConnect Drain M968850 e One wipe effortlessly removes spots e Fewer parts installs in less time Eliminates the need for cleaners and scrubbing e Never needs adjustment e Permanent surface protectant remains beautiful Guaranteed to seal properly the first time every time for the life of the faucet e EverClean available on Polished Chrome Satin Nickel Stainless Steel Polished Brass or any combination of these finishes Your new American Standard faucet is designed to work only with the SpeedConnect drain To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Required tools N Screwdriver Channel Locks INSTALL FAUCET EZTI Sipps eire begining Seat SEAL 1 into under side of ESCUTCHEON RING 2 Seat ESCUTCHEON RING 2 with collar facing up into groove in faucet base Feed FAUCET SUPPLIES 3 MOUNTING STUD 4 and DRAIN CABLE ASSEMBLY 8 through ESCUTCHEON RING 2 and the mounting hole of lavatory or mounting surface Figure A From below push GASKET 7 and RETAINING WASHER 5 onto
5. MOUNTING STUD 4 Secure Faucet with MOUNTING NUT 6 pulling faucet to front of sink so SUPPLIES 3 rests against mounting hole Before final tightening make sure collar on MOUNTING NUT 6 is seated into RETAINING WASHER 5 Figure B Adjust Faucet so that it is centered Tighten MOUNTING NUT 6 to complete faucet mounting Figure A MOUNTING SURFACE COLLAR ON MOUNTING NUT Figure B 2 VALVE INSTALLATION m Place RUBBER RING 9 into DECK ADAPTER 10 E Install LOCKNUT 11 and RUBBER WASHER 12 onto VALVE BODY 18 From under side of mounting surface install VALVE BODY 13 through valve mounting holes Threads of VALVE BODY 13 should extent at least 5 16 of a inch above mounting surface top Fig A Thread DECK ADAPTER 10 onto VALVE BODY 13 until snug against internal stop If necessary adjust LOCKNUT 11 MOUNTING SURFACE 3 VALVE OUTLET SUPPLY CONNECTION mM Connect Red Banded Hose to Left Valve and Blue Banded Hose to Right Valve m Attach COUPLING NUTS 1 of SUPPLY HOSES 2 and tighten making water tight connection Important Loop SUPPLY HOSES 2 as illustrated so they do not kink L wN NSN TnT a lN TT 2 i BLUE pamm HOT BAND COLD m 8te Rs 5 AVL RED BAND il INSTALL HANDLES E Push ADAPTER 1 on VALVE STEM 2 so that the hole of the ADAPTER 1 without a spline is facing up See figure A Tighten THREAD ON TO DECK ADAPTER STEM SCREW 3 to s
6. ecure ADAPTER 1 Find correct position of LEVER HANDLE ASSEMBLY 4 by adjusting male teeth on ADAPTER 1 to female teeth in HANDLE 4 Thread LEVER HANDLE ASSEMBLY 4 onto DECK ADAPTER 5 E until snug against mounting surface Figure A SPLINE END DOW D POP UP DRAIN Remove CLEAR PLASTIC COVER 1 Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 Tighten TAILPIECE 4 on DRAIN BODY before installing DRAIN BODY Fig B 6 REMOVE FLANGE E Thread FLANGE 1 counter clockwise and remove FLANGE 1 and FOAM GASKET 2 from drain body Fig A E Thread LOCKNUT 3 clock wise to bottom of drain body Push GASKET 4 down against LOCKNUT 3 Fig B INSTALL DRAIN FROM BELOW FIXTURE E From under side of SINK 7 Tighten LOCKNUT 1 firmly with Adjustable install DRAIN BODY 1 up q p Wrench or Channel Locks through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the SINK Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 firmly FLANGE GASKET AND POP UP KNOB Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET 3 is fully compressed and not visible Fig A i WHITE FOAM m POP UP KNOB 1 must be fully down Fig B GASKET RAIN D NOT VISIBLE FLANGE 1 0 ATTACH CABLE CONNECTOR E Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION
7. g G E To install the stopper in Locked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig G E Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J ano lt GNInED REAR OF SINK m Re install the Cam Cap making sure the guide teeth are facing Qa outward If the Cam Cap does not snap into place then rotate DRAIN the Cam to make sure tt Is fully inserted Fig K m Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Locked Mode Troubling Shooting Guide to complete installation Stopper will be Vandal Proof in Locked mode and not be removable Unlocked Mode m Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H a LOGO m To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H E Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J Uj LOOP TOWARD FRONT OF SINK Re install the Cam Cap making sure the guide teeth are facing Dw
8. nector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam in the illustration Fig B Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go At this point the Stopper should be in the UP position Fig B C Push DOWN on the Lift Knob to make sure it is fully down Fig C Re attach the Cable to the Drain Body Connection 2 by threading the Cable Connector 1 clockwise onto the Drain Body Connection 2 and hand tighten Fig A STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F A i REMOVE CAM CAP M968850 STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways Locked Mode Stopper cannot be removed or Unlock Mode Stopper is removable Locked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fi