1. 3 1 2 m M a rSo Hf Se ae List of Required Components not included ne a z th j e Drain 1583 470 e Bath Filler 19 574 B 464mm see your American Standard Distributor ROUGH 8 U4 FLOOR INTEGRAL 1 1 2 N P T M aml ral ae SUPPORT THREADS 70mm FEET 1 1 2 0 D TAILPIECE 2 3 4 2 j Bees List of Required Tools and Supplies GENERAL SPECIFICATIONS FOR 2774 WHIRLPOOL Tools Supplies INSTALLED SIZE 72 x 42 x 19 3 4 In e Level e Nails 1829mm x 1067 mm x 502mm e Tape Measure e Putty WEIGHT 137 Lbs 62 Kg e Pipe Wrench e Caulking waterproof WEIGHT w WATER 821 Lbs 372 Kg e 1x30 2x2 GAL TO OVERFLOW 82 Gal 310 L e Slip Joint Pliers Stri Min OPERATING GAL 66 Gal 256 L e Screw Driver tringers BATHING WELL AT SUMP____ 50 x 27 In 1270 mm x 686 mm e Standard e Drop Cloth BATHING WELL AT RIM 65 x 33 In 1651 x 838mm Woodworking Tools e 20 amp GFI WATER DEPTH TO OVERFLOW 13 In 330 mm e Personal Safety Outlet Cement Plaster Grout PTS 27 8 CUBE FT 55 5 WHIRLPOOL ELECTRICAL SPECIFICATIONS PUMP 2 1 HP 14 4 AMPS 120V GENERAL INSTALLATION INFORMATION Carefully uncrate and inspect your new bath for any shipping damage If such damage is found report it to your vendor immediately After inspection and during installation protect the bath from construction damage After installation and before enclosing with wallboard tile etc water test the unit and check for leak
2. Abrasive cleaners must not be used since they will scratch and dull the surface Dulled areas can be restored by rubbing with a white automotive type polishing compound and waxing with a liquid wax 752502 100 REV H 4 SPIC AND SPAN IS A REGISTERED TRADEMARK OF PROCTER amp GAMBLE
3. CADET 6 x 42 2774 XXXW SERIES American Standard HIGH GLOSS ACRYLIC WHIRLPOOL BATHING POOL INSTALLATION INSTRUCTIONS PROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONS FLOOR LOADING 42 Lbs Sq Ft 203 Kgs Sq m PROJECTED AREA Equipment Caulking Gun 1829 mm Faos mn 7 THANK YOU zzomm gie Sereno eens O omma J EE EER OR SLAND for selecting an American Standard bath Your new H a bath is shipped to you after careful inspection The secrirtine WALL L Ae Q whirlpool version is completely assembled with pump DIMENSIONS le ae motor and system piping All you need to finish the din 4 SWITCH installation are your selected fittings and electrical O att connections for a whirlpool oe To insure maximum performance and pleasure from oh FOR DRAIN this product please follow the instructions and p j cautions C L D 57mm NX 2 AIR VALVES Na OUTLINE OF CUTOUT SUPPLIES I 2 1 4 8 JETS ALT FITTING 1791mm x 1029mm 70 1 2 X 40 1 2 a i Nor oF oran PER a List of Optional Components not included K SHOWER ARM e Safe T Heater 9075 120 Rae es ot e Tile Bead Kit 751755 100 E a RE e Apron Kit Na 658789 LoF f REMOVABLE see your American Standard Distributor OVERFLOW 305mm Seron BLANK 12 EE i em e Sen
4. LY UNLESS AN ACCESS OPENING OF AT LEAST UNLESS AN ACCESS OPENING OF AT LEAST 12 X 24 305 X 610MM IS PROVIDED 12 X 24 305 X 610MM IS PROVIDED WARRANTY SERVICE WILL NOT BE PERFORMED WARRANTY SERVICE WILL NOT BE PERFORMED 752502 100 REV H 2 ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes WARNING When using electrical products basic precautions should always be observed including the following 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Install to permit access for servicing 4 All building materials and wiring should be routed away from the pump body and heater if equipped The whirlpool should be installed on a 120 vac 20 amp dedicated circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three 3 wire circuit from the electrical supply panel A grounded neutral wire and a third wire earth ground are essential ADDING THE SAFE T HEATER REQUIRES A SEPERATE 15 AMP MAXIMUM GFCI CIRCUIT ELECTRICAL INSTALLATION SEPARATE 20 AMP GFCI OUTLET WHIRLPOOL MOUNTED 120 VAC AIR SWITCH OR WALL TIMER ELECTRICAL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS 752502 100 REV H 3 WI
5. RE SELECTION GUIDE Maximum distance from fusebox to motor The sizes shown on this chart are recommendations Motor 50 100 150 for copper conductors Hi Performance only Always follow Rating 115V Power Line local and national 2 1 10 8 electrical codes DRAIN CONNECTION AND SYSTEM TEST Using recommended drain opening connect whirlpool drain to waste line Tighten all drain joints securely Check the pump couplings and make sure they are hand tight Clean the whirlpool and fill with water to a point 2 above the top of the highest jet Recheck the pump couplings and make certain that they are not leaking Although the pump couplings are factory tightened and inspected some loosening may have occured during transit Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on Check for leaks around all piping connections while the whirlpool is running POST INSTALLATION CLEAN UP Remove all construction debris from bath Tile grout can be removed with a wooden popsicle stick or tongue depressor Do not use wire brushes or any other metal implement on bath surface Post installation clean up generally can be completed using warm water and liquid dishwashing detergent Stubborn dirt or stains may be removed using granular Spic and Span mixed with water Painter s naphtha can be used to remove excess adhesives and or wet oil base paint HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES
6. pening and level the deck shimming the integral support feet as necessary Mark the final position of the underside of the deck by tracing a line on to the studs see Figure 1 2 Remove the whirlpool and attach a 2 x 4 stringer to the studs with the top of the stringer touching the traced line 3 Install drain components to the whirlpool following the manufacturers instructions Before replacing your whirlpool for final installation be certain that an opening has been provided in the sub floor for the drain See the roughing in drawing for suggested opening size and location dimensions 4 Replace whirlpool and re shim the integral support feet shimming the entire length of the support feet Secure the shims using construction adhesive silicone mortar or equivalent materials While not a necessity the use of a foundation base consisting of cement e g Sakrete mortar or grout will help provide a solid and secure installation FIG 1 a Y WALLBOARD TILE SEALANT BEAD STRIP BATH ADHESIVE i 464mm 18 1 4 M re LEVELING STRINGER NOTE Tile bead kit not included and must be purchased separately TYPICAL RECESS INSTALLATION TYPICAL PIER TYPE INSTALLATION AS DESIRED 029mm 40 1 2 1791mm 70 1 2 CUTOUT 72 1 8 LEVELING AS DESIRED STRINGERS LEVELING SURFACE WATERPROOF lt 2 SEALANT S amp S ACCESS PANEL WHIRLPOOL ONLY WHIRLPOOL ON
7. s Do not make modifications to the whirlpool system or remove pump from factory mounting This could adversely affect the safety and performance of the whirlpool and void the warranty Do not handle or move the whirlpool by the pump motor or piping system Fittings bath filler shower arm etc are not provided with the bath and must be ordered separately Framing and enclosing materials are provided by others Check for availability of optional American Standard wall tiling bead required for recess installations Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth WARNING Do not lift whirlpool by the piping harness at any time FOR AFTER SALES SERVICE CALL 1 800 442 1902 WEEKDAYS American Standard Inc 2003 All product names listed herein are trademarks of American Standard Inc unless otherwise noted 752502 100 REV H INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this whirlpool may require framing procedures other than those shown Locate studs as required Ensure roughing in dimensions are proper plumb and square Provisions must be made in all installations for an access opening for servicing the pump and controls It is strongly recommended that an additional opening be provided for access to the drain components NOTE The apron should not be used as the primary access opening 1 Position the whirlpool into the installation o
Download Pdf Manuals
Related Search
Related Contents
d2 Quadra User Manual DICHIARAZIONE AMBIENTALE Eglo EINBAUSPOT 12V STARLIGHT Equip 2m DisplayPort > HDMI M/M AR-C250 Key Operator Operation Manual Polaris 9921477 Offroad Vehicle User Manual 3. ANTHROPOLOGIE SOCIALE, CULTURELLE ET MÉDICALE Kensington AbsolutePower Copyright © All rights reserved.
Failed to retrieve file