Home
American Standard 2776.XXXW User's Manual
Contents
1. AT SUMP 20 x 40 508 x 1016mm BATHING WELL AT RIM 26 x 53 1 2 660 x 1359mm WATER DEPTH TO OVERFLOW 14 1 2 368mm FLOOR LOADING 43 Lbs Sq Ft 208 Kgs Sq m PROJECTED AREA PTS so Os 98 CUBE FT 35 3 WHIRLPOOL ELECTRICAL SPECIFICATIONS SYSTEM PUMP 1 1 HP 9 9 AMPS 120V GENERAL INSTALLATION INFORMATION BATH MAY ONLY BE INSTALLED IN A RECESS TYPE INSTALLATION THANK YOU for selecting an American Standard bath Your new bath is shipped to you after careful inspection The whirlpool version is completely assembled with pump motor and system piping All you need to finish the installation are your selected fittings and electrical connections for a whirlpool To insure maximum performance and pleasure from this product please follow the instructions and cautions List of Required Components not included e Drain 1583 470 e Bath Filler see your American Standard Distributor List of Required Tools and Supplies Tools Supplies e Level e Nails e Tape Measure e Putty e Pipe Wrench e Caulking waterproof e Slip Joint Pliers e 1x3orr 2x2 e Screw Driver Stringers e Standard e Drop Cloth Woodworking Tools e 15 amp GFI e Personal Safety Outlet Equipment e Cement Plaster e Caulking Gun Grout GENERAL INSTALLATION INFORMATION Carefully uncrate and inspect your new bath for any shipping damage If such damage is found report it to your vendor immediately After inspection and during
2. AVOID DAMAGING THE TUB THE TILE OR SIMILAR FINISHED FLOOR WILL BE BUTTED AGAINST THE BOTTOM OF THE TUB APRON ALSO HOLDING THE TUB IN PLACE FOR AFTER SALES SERVICE CALL 1 800 442 1902 WEEKDAYS 752561 100 Rev D American Standard Inc 2003 All product names listed herein are trademarks of American Standard Inc unless otherwise noted INSTALLATION AND FRAMING INSTRUCTIONS Locate studs as required Ensure roughing in dimensions are proper plumb and square Access to Pump Motor may be made through the access opening in the apron panel It is strongly recommended that an additional opening be provided for access to the drain components NOTE The apron may be used as the primary access opening 1 As shown in Fig 1 mark the position of the underside of the deck by tracing a line onto the studs at the height indicated using a level or other suitable straight edge 2 With the top of the stringer touching the traced line attach the stringer to the studs 3 Install drain components to the whirlpool or bath following the manufacturers instructions See the roughing in drawing for suggested opening size and location dimensions 4 THIS BATH MUST BE SUPPORTED ALONG ITS ENTIRE BOTTOM We recommend the use of mortar as bedding material sand is not recommended Apply enough bedding to support the complete bottom of the bath After the bedding has been poured and before it sets position whirlpool or bath within recess until the r
3. from bath Tile grout can be removed with a wooden popsicle stick or tongue depressor Do not use wire brushes or any other metal implement on bath surface Post installation clean up generally can be completed using warm water and liquid dishwashing detergent Stubborn dirt or stains may be removed using granular Spic and Span mixed with water Painter s naphtha can be used to remove excess adhesives and or wet oil base paint HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES Abrasive cleaners must not be used since they will scratch and dull the surface Dulled areas can be restored by rubbing with a white automotive type polishing compound and waxing with a liquid wax 752561 100 Rev D 4 SPIC AND SPAN IS A REGISTERED TRADEMARK OF PROCTER amp GAMBLE
4. installation protect the bath from construction damage Before installation and before enclosing with wallboard tile etc water test the unit and check for leaks If a whirlpool do not make modifications to the whirlpool system or remove pump from factory mounting This could adversely affect the safety and performance of the whirlpool and void the warranty Do not handle or move the whirlpool by the pump motor or piping system Fittings bath filler shower arm etc are not provided with the bath and must be ordered separately Framing and enclosing materials are provided by others IMPORTANT Water test unit before installation and enclosure LOCATE STUDS AS REQUIRED INSURE ROUGH DIMENSIONS ARE PROPER PLUMB AND SQUARE FOR WHIRLPOOLS ACCESS TO PUMP MOTOR MAY BE MADE THROUGH ACCESS OPENING IN APRON PANEL THE FOLLOWING PROCEDURE MUST BE USED FOR ALL INSTALLATIONS LEVELING SUPPORT STRINGER SHOULD BE AS INDICATED THIS BATH IS NOT SELF SUPPORTING AND MUST BE SUPPORTED ALONG IT S ENTIRE BOTTOM SUPPORT WITH MORTAR OR GROUT POSITION BATHTUB WHIRLPOOL WITHIN THE RECESS CHECK LEVEL FRONT TO BACK SIDE TO SIDE AND SHIM AS NECESSARY TO SECURE THE TUB TO WOOD STUDS USE DRYWALL SCREWS W WASHERS OR ROOFING NAILS IMMEDIATELY ABOVE THE FLANGE OF THE TUB TO SECURE THE TUB TO STEEL STUDS USE 4 DRYWALL SCREWS AND FLATWASHERS SEE PAGE 2 FOR COMPLETE INSTALLATION INFORMATION CAUTION TAKE EXTRA CARE WHEN DRIVING NAILS OR SCREWS TO
5. CADET 5 x 32 INTEGRAL APRON WITH 2776 XXXW SERIES American Standard removaste access PANEL VWHIRLPOOL BATHING POOL HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS INSTALLATION INSTRUCTIONS 59 7 8 gt lt _12 gt 1521mm 305mm WATER TO ELR RETENTION ammi a7 FLANGE gt 3 SIDES 19mm A FINISHED 7 SEE FITTING WALL STOR 14 3 4 DIMENSIONS L ho 3 375mm Y ON OFF I 813mm SWITCH FOR DRAIN O C L OF 2 3 8 2 AIR VALVES _ ACCESS TO PUMP MOTOR SUPPLIES j 60mm 8 JETS THROUGH REMOVABLE O FRONT ACCESS PANEL C L OF DRAIN C L OF SHOWER ARM FINISHED OPTIONAL TO WALLA FINISHED FLOOR USUALLY BETWEEN 7 8 WATER C L OF 65 amp 78 RETENTION s VALVES 1651 amp 1981mm FLANGE yt 3 SIDES et biter C L OF SPOUT OVERFLOW 305mm OPT 2 3 4 102 ai E LEVELING STRINGER Comm NOT FOR SUPPORT TOP OF F AS L UNDERSIDE DECK Sou ah 7 OF DECK 508mm 19 3 4 ROUGH I ice FLOOR BATH 1 1 2 N P T M SUPPORT THREADS 2 3 4 aA a MATERIAL 4 4 2 0 D TAILPIECE 70mm 58 117mm GENERAL SPECIFICATIONS FOR 2776 WHIRLPOOL INSTALLED SIZE 59 7 8 x 32 x 20 1521 x 813 x 508mm WEIGHT 115 Lbs 52 Kg WEIGHT w WATER 574 Lbs 258 Kg GAL TO OVERFLOW 55 Gal 208 L WHIRLPOOL MIN OPERATING VOL 45 Gal 171 L BATHING WELL
6. im is leveled against the leveling stringers see Typical Recess Installation shown below The rim of the bath MUST NOT support weight Allow the bedding material to completey harden before applying weight to the rim or bottom of the bath Any finish material such as tile or wall board must be self supporting if it contacts the deck of the bath FIG 1 SUGGESTED WHIRLPOOL BATH INSTALLATION METHOD WOOD STUDS WATERPROOF DRYWALL OR CEMENT BOARD 1 x 3 25 x 76mm WOOD TYPICAL RECESS INSTALLATION STRINGER FULL LENGTH STEEL STUDS WATERPROOF DRYWALL OR CEMENT BOARD TILE SEALANT 4 102mm DRYWALL SCREW 60 Seam LEVELING STRINGERS 1 x 3 25 x 76mm WOOD STRINGER FULL LENGTH SECURE THE BATH TO THE STUDS AS SHOWN FOR WOOD OR STEEL STUD CONSTRUCTION 752561 100 Rev D 2 ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes WARNING When using electrical products basic precautions should always be observed including the following 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Install to permit access for servicing 4 All building materials and wiring should be r
7. outed away from the pump body and heater if equipped The whirlpool should be installed on a 120 vac 15 amp dedicated circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three 3 wire circuit from the electrical supply panel A grounded neutral wire and a third wire earth ground are essential ELECTRICAL INSTALLATION SEPARATE 15 AMP GFCI OUTLET WHIRLPOOL MOUNTED 120 VAC AIR SWITCH OR WALL TIMER ELECTRICAL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS 752561 100 Rev D 3 WIRE SELECTION GUIDE Maximum distance from Motor fusebox to motor The sizes shown on this Hi Perfomance chart are recommendations only Always follow 115V Power Line local and national electrical codes DRAIN CONNECTION AND SYSTEM TEST Using recommended drain opening connect whirlpool drain to waste line Tighten all drain joints securely Check the pump couplings and make sure they are hand tight Clean the whirlpool and fill with water to a point 2 above the top of the highest jet Recheck the pump couplings and make certain that they are not leaking Although the pump couplings are factory tightened and inspected some loosening may have occured during transit Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on Check for leaks around all piping connections while the whirlpool is running POST INSTALLATION CLEAN UP Remove all construction debris
Download Pdf Manuals
Related Search
Related Contents
BJ192M Panel Mounting Energy Meter User Manual Version Stamina Products 55-4650D User's Manual VoIP FXO Gateway - Micronet Communications El MODELO: 3205 El MANUAL de DUEÑOS HoMedics WFL-SLST Scale User Manual © 2015 – Yvon Bourque June 2015 K-3II Release. Philips HD9322 Copyright © All rights reserved.
Failed to retrieve file