Home
HoMedics WFL-SLST Scale User Manual
Contents
1. sign To increase the speed move the switch slowly downward in the direction of the plus sign You will hear a click as the switch moves to each speed level At its highest speed level the switch will cease to move any further To decrease the pump speed move the switch upward toward the minus sign Similarly at its lowest speed the switch will cease to move any further Fig 1 NOTE It is recommended the pump be set at its highest speed during assembly and later adjusted to a lower setting if desired Be sure to unplug the pump before adjusting the speed setting Figure 1 Minimum Water Level please operate Z pump completely submerged Keep the water level above the minimum water level ALL THE TIME Flow Control Valve faster water output slower water output SS AAANRARANDNA YVUUUUUUUUY 3 Place the basin on a flat surface Fig 2 Figure 2 Fountain Top Stones Socket 4 Insert the waterproof light into the light hole located on the underside of the panel Fig 3 Figure 3 5 Join the pump outlet and the connector tube under the panel Fig 4 Figure 4 an l Fountain a Top OD J Connector Tube 6 Place the panel on top of the basin Note Lead the power cord through the slot located at the top of the basin This will allow the fountain panel and top to sit evenly on the bas
2. Mail To HoMedics Consumer Relations Service Center Dept 168 3000 Pontiac Trail Commerce Township MI 48390 e mail cservice homedics com Phone 800 466 3342 ONE YEAR LIMITED WARRANTY Valid in USA only HoMedics Inc guarantees this product free from defects in material and workmanship for a period of one year from the date of purchase except as noted below This HoMedics product warranty does not cover damage caused by mis use or abuse accident the attachment of any unauthorized accessory alteration to the product or any other conditions whatsoever that are beyond the control of HoMedics This warranty is effective only if the product is purchased and operated in the USA A product that requires modification or adaptation to enable it to operate in any country other than the country for which it was designed manufactured approved and or authorized or repair of products damaged by these modifications is not covered under warranty HoMedics shall not be responsible for any type of incidental consequential or special damages All implied war ranties including but not limited to those implied warranties of fitness and merchantability are limited in the total duration of one year from the original purchase date To obtain warranty service on your HoMedics product either hand deliver or mail the unit and your dated sales receipt as proof of purchase post paid along with check or money order in the amount of 5
3. 00 payable to HoMedics Inc to cover handling Upon receipt HoMedics will repair or replace as appropriate your prod uct and return it to you postpaid If it is appropriate to replace your product HoMedics will replace the product with the same product or a comparable product at HoMedics option Warranty is solely through HoMedics Service Center Service of this product by anyone other than HoMedics Service Center voids warranty This warranty provides you with specific legal rights You may have addi tional rights which may vary from state to state Because of individual state regulations some of the above limitations and exclusions may not apply to you For more information regarding our product line in the USA please visit www homedics com 2005 HoMedics Inc and its affiliated companies all rights reserved HoMedics is a registered trademark of HoMedics Inc and its affiliated companies Envirascape is a trademark of HoMedics Inc and its affiliated companies All rights reserved IB WFLSLST RELAXATION FOUNTAIN envira cape Slate Streams Instruction Manual and Warranty Information year limited warranty WEFL SLST The sounds of nature soothe human nature Thank you for purchasing EnviraScape HoMedics tabletop relaxation fountain This like the entire HoMedics product line is built with high quality craftsmanship to provide you years of dependable service We hope that you wi
4. to keep water level at an optimum level to avoid shortening the life of the pump NOTE Never let the pump run dry as this will shorten the life of the pump e Fountain Storage Unplug the fountain from the electrical outlet empty the water and store rocks and fountain in a dry cool place e Changing Light Bulb First unplug fountain and let bulb cool down Remove the bulb cover by holding the glass bulb cover in dry hand and rubber neck with other hand Slowly pull apart Slight twisting may help to loosen Be gentle with bulb cover since it is glass Never pull on cord Next pull bulb straight out and replace with new bulb inserting prongs into the holes Replace bulb cover securely Figure 6 PVC Tubing Inserts Here Back Pl v ac ate Impeller _ jj Housing Pump Inlet lt Front Plate Suction Feet Flow Control Lever Caution All servicing of this fountain must be performed by authorized HoMedics service personnel only Figure 7 Troubleshooting If the pump fails to operate check the following Check the circuit breaker or try a different outlet to make sure the pump is getting electrical power NOTE Always disconnect from electrical outlet before handling the pump If the pump gurgles spews or burps Check the water level to make sure the pump has enough water to function Obtaining a desired water level Check the water level daily the first week to measure t
5. aution Please read all instructions carefully before operating e Never leave the appliance unattended especially if children are present e Never cover the appliance when it is in operation e This unit should not be used by children without adult supervision e Connect the pump with the proper voltage as indicated on the pump label e Always keep the cord away from high temperature and fire e Unplug the pump from power source before cleaning maintenance or disassembling e To get the best flowing effect product must be placed on a flat surface and should never be placed on an electrical appliance e Never let pump run dry as this will shorten life of the pump e Do not lift carry hang or pull the pump by the power cord e Operate with tap or distilled water only e Operate pump completely submerged for proper cooling e The electrical cord of this product cannot be replaced If it sustains damage you must stop using this product immediately and return it to the HoMedics Service Center for repair See the warranty section for HoMedics address e Disconnect the appliance from outlet before putting hands into water Attention In order to get best results Assembly and Instructions for Use 1 Unpack the product Wipe off dust with a damp cloth 2 Familiarize yourself with the pump The pump speed is con trolled by the switch located at the front of the pump The speed is indicated by a plus and minus
6. he rate of evaporation refill with water as needed elf water is splashing outside the fountain Adjust the flow control valve to a lower setting on the pump Drip Loop RELAXATION FOUNTAIN Slate Streams envira cape Replacement Parts Order Form PART DESCRIPTION QUANTITY COST PP ROCKBLB Replacement bulbs and covers for 5 00 WFL SLST pack of 5 SUBTOTAL TAX Michigan Residents add 6 Total HOMEDICS Mail To HoMedics Consumer Relations Service Center Dept 168 3000 Pontiac Trail Commerce Township MI 48390 e mail cservice homedics com Detach and return order form with check or money order payable to HoMedics Inc Please allow 2 to 4 weeks for delivery Name Address City State Zip Code Phone Number
7. in 7 Insert the top connector into the socket located in the center of the panel Fig 5 8 Fill the basin with approximately 3 1 2 cups of water The pump needs to be completely submerged in water in order to work properly 9 Arrange the rocks on the panel for decoration Watch for splashing and adjust accordingly 10 Attach the A C adaptor jack to the base power cord Fig 2 11 Plug the cord into 120V household outlet The fountain is con trolled by the switch located on the power cord If pump does not operate rotate in line switch once to turn on and once to turn off Note Ensure that the electrical cord loops below the electri cal outlet to form a Drip Loop This will prevent water from running down the cord into the electrical outlet Fig 7 5 Maintenance e To clean the pump Unplug from electrical outlet Remove it from the base of the fountain Use a small brush or stream of water to remove any debris Fig 7 e To keep water clean Periodically change water and clean the product according to the water condition Keeping the water clean prevents the water from becoming sticky and forming micro organisms We recommend distilled water to prevent mineral build up e To clean off hard water deposits on the base or stones Soak the container and rocks in a mixture of vinegar and water to clean and remove any mineral build up e Keeping the water at an optimum level Add water periodically
8. ll find it to be the finest product of its kind EnviraScape enables you to create an all encompassing envi ronment with sound The sound of flowing water enhances your environment by releasing negative ions and promoting relaxation Only EnviraScape offers you the luxury of these vital benefits with its creative design which adds beauty to any indoor environment EnviraScape Features Innovative artistic design enhances the environment at home or at work e Unique lighting illuminates fountain and natural water flow e The soothing sound of cascading water creates a stress free ambiance e Improves concentration by masking distractions so you can stay focused e Durable electrical water pump can be operated from any indoor electrical outlet e Convenient tabletop size fountain measures 7 5 L x 7 5 W x 10 H IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance basic precautions should always be followed including the following READ ALL INSTRUCTIONS BEFORE USING DANGER To reduce the risk of electric shock e Always unplug the appliance from the electrical outlet immediately after using and before cleaning e Do not reach for an appliance that has fallen into water Unplug it immediately e Do not place or store appliance where it can fall or be pulled into a tub or sink Do not place in or drop into water or other liquid e Do not connect to any voltage other than that shown on the pump e Do not
9. pump flammable liquids e Do not use water above 86 Fahrenheit CAUTION The pump must be completely submerged in water If the pump is making noises most likely it is not completely submerged in water CAUTION Only set the fountain and fountain parts on waterproof surfaces WARNING To reduce the risk of burns fire electric shock or injury to persons e An appliance should never be left unattended when plugged in Unplug from outlet when not in use and before putting on or taking off parts or attachments e Close supervision is necessary when this appliance is used by or near children invalids or disabled persons e Use this appliance only for its intended use as described in this manual Do not use attachments not recommended by HoMedics specifically any attachments not provided with the unit e Never operate this appliance if it has a damaged cord plug pump cable or housing If it is not working properly if it has been dropped or damaged return it to Homedics Service Center for examination and repair e Keep cord away from heated surfaces e Never drop or insert any object into any opening e Do not operate where aerosol spray products are being used or where oxygen is being administered Do not carry this appliance by power cord or use cord as handle To disconnect remove plug from outlet e This appliance is designed for indoor use only Do not use outdoors SAVE THESE INSTRUCTIONS C
Download Pdf Manuals
Related Search
Related Contents
AE 485 S - Alan-Albrecht Service Philips D2152WT 電気の使い方 - 東京都地球温暖化防止活動推進センター Die Taste 物品明細入力シート取扱説明書(債権者用) 名寄市 必要条件:Microsoft Kendall SCD™ 700 Series Components T'nB Moka 公正競争規約 公正競争規約施行規則 (取扱説明書の必要表示事項) 第 Bedienungsanleitung de Operating instructions en Használati Copyright © All rights reserved.
Failed to retrieve file