Home

Amana AGR5330BAS Dimension Guide

image

Contents

1. A 36 91 4 cm B 297 75 9 cm C 24 61 6 cm D 46 117 5 cm IMPORTANT Range must be level after installation Follow the instructions in the Level Range section Using the cooktop as a reference for leveling the range is not recommended Page 1 of 2 Dimensions are for planning purposes only For complete details see Installation Ref W10620415C Instructions packed with product Specifications subject to change without notice 3 12 14 CABINET OPENING DIMENSIONS Because Whirlpool Corporation policy includes a continuous commitment to improve our products we reserve the right to change materials and specifications without notice Cabinet opening dimensions shown are for 25 64 0 cm countertop depth 24 61 0 cm base cabinet depth and 36 91 4 cm countertop height If the cabinet depth is greater than 24 61 0 cm oven frame must extend beyond cabinet fronts by 1 2 1 3 cm minimum IMPORTANT If installing a range hood or microwave hood combination above the range follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface A 18 45 7 cm min clearance upper side cabinet to countertop B 13 33 0 cm max upper cabinet depth C 30 76 2 cm min cabinet opening width D For minimum clearance to top of cooktop see NOTE E 30 76 5 cm min opening width F This shaded area recommended for instal
2. Amana 30 76 2 cm Freestanding Gas Range PRODUCT MODEL NUMBERS AGR5330BA Electrical Requirements A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommended It is recommended that a Separate circuit serving only this range be provided e This range is equipped with a power supply cord having a 3 prong ground plug To minimize possible shock hazard the cord must be plugged into a grounded 3 prong outlet Gas Supply Requirements Type of gas Natural gas This range is design certified by CSA International for use with Natural gas or after proper conversion for use with LP gas e This range is factory set for use with Natural gas See Gas Conversions Section The model serial rating plate located on the oven frame behind the top left side of the oven door has information on the types of gas that can be used If the types of gas listed do not include the type of gas available check with the local gas supplier LP gas conversion Conversion must be done by a qualified service technician No attempt shall be made to convert the appliance from the gas specified on the model serial rating plate for use with a different gas without consulting the serving gas Supplier See Gas Conversions section Gas Supply Line e Provide a gas supply line of 34 1 9 cm rigid pipe to the range location A Smaller size pipe on longer runs may result in insufficient
3. gas supply With LP gas piping or tubing size can be 1 2 1 3 cm minimum Usually LP gas Suppliers determine the size and materials used in the system NOTE Pipe joint compounds that resist the action of LP gas must be used Do not use TEFLON tape Flexible metal appliance connector e f local codes permit a new CSA design certified 4 to 5 ft 122 to 152 4 cm long 12 1 3 cm or 3 4 1 9 cm I D flexible metal appliance connector may be used for connecting range to the gas supply line e A 1 2 1 3 cm male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator Do not kink or damage the flexible metal tubing when moving the range e Must include a shutoff valve The supply line must be equipped with a manual shutoff valve This valve Should be located in the same room but external to the range opening such as an adjacent cabinet It should be in a location that allows ease of opening and closing Do not block access to shutoff valve The valve is for turning on or shutting off gas to the range A Gas supply line B Shutoff valve open position C To range TEFLON is a registered trademark of E l Du Pont De Nemours and Company Because Whirlpool Corporation policy includes a continuous commitment to improve our products we reserve the right to change materials and specifications without notice PRODUCT DIMENSIONS
4. lation of electrical outlet G This shaded area recommended for installation of rigid gas pipe H 2 5 1 cm min countertop space to side wall or other combustible material 1 24 61 0 cm J 10 25 4 cm K 8 20 3 cm L 5 12 7 Gm M 2 5 1 cm N 3 7 6 cm NOTE 24 61 0 cm minimum when bottom of wood or metal cabinet is covered by not less than 1 4 0 64 cm flame retardant millboard covered with not less than No 28 MSG sheet steel 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet Page 2 of 2 Dimensions are for planning purposes only For complete details see Installation Ref W10620415C Instructions packed with product Specifications subject to change without notice 3 12 14

Download Pdf Manuals

image

Related Search

Related Contents

Jenn-Air 8112P212-60 User's Manual  Lassco Spinnit EBM-S Paper Drill  User's Manual  MDV-323 - ご利用の条件|取扱説明書|ケンウッド  

Copyright © All rights reserved.
Failed to retrieve file