Contents

1. Auto Medium A Low Switch Off Press ON OFF button to stop air conditioner 1 When AUTO mode is set the air conditioner will adjust the fan speed and select the COOL or DRY mode according to the indoor temperature 2 When AUTO mode is set SLEEP and AUH functions are not available 3 When DRY mode is set in accordance with the D value between indoor temperature and set temperature the air conditioner will start or stop the cooling operation and fan speed automatically to decrease room humidity The fan speed may change to maintain the humidity 4 When FAN mode is set temperature can t be adjusted Step 2 of Operating precudures is not effective Only high medium and low fan speed can be set no Auto fan speed 5 In the cooling only model the function is not available and there is AUTO HEAT mode Clock Setting Press TIME button to select clock display will flash Press HOUR button to change the hour display each press of HOUR button will increase or decrease the time display by 1 hour hour display will be changed continuously when pressing it continuously J Press MINUTE button to change the minute display the method as step 2 The clock display will flash for 10 seconds after setting the remote controller displays current time On Timer
2. Set the clock time as ae Clock Setting 23 teom 23 23 Press TIME button to select ON aj clock display will flash Press HOUR or MINUTE button set the time to turn on the air conditioner on timer At this time if user press MINUTE button it will increase or decrease by 10 minutes Press TIMER button to select ON 9 Note 1 When on timer function 15 set air conditioner will be turned off immediately It will be turned on at the set time symbol ON will b Meleted If the set time is as same to the current time air conditioner will be turned on at this time of next day 2 Press ON OFF to cancel On Timer function air conditioner will be turned on immediately 10 Off Timer i SET TEMP 23 EO Set the clock time as Clock Setting Press TIME button to select COFF clock display will flash Press HOUR or MINUTE button set the time to turn on the air conditioner on timer At this time if user press MINUTE button it will increase or decrease by 10 minutes Press TIMER button to select prr Note 1 When off timer function is set air conditioner will be turned on immediately It will be turned off at the set time symbol OF will be deleted If the set time is as same to the current time
3. air conditioner will be turned off at this time of next day 2 Press ON OFF to cancel Off Timer function air conditioner will be turned off immediately Program Control Note 1 In accordance with the clock time air conditioner will select to work in On Timer or Off Timer mode automatically 1 Refer to Clock Setting to Set the clock time 2 Refer to On Timer to Set the time to turn on the air conditioner 3 Refer to Off Timer to Set the time to turn off the air conditioner as gt PROGRAM PROGRAM MODE FAN SPEED ON 2 Air conditioner will be turned on off at the set time everyday If user turns off the air conditioner by hand before the set time then Off timer function will be cancelled but On timer function is still effective If user turns on the air conditioner by hand before the set time then On timer function will be cancelled but Off timer function is still effective Press TIMER button to select PROGRAM KEY OPERATING INSTRUCTON FOR THE AIR CONDITIONER 11 Before Starting This Unit 1 Select a suitable location make sure you have easy access to an electrical outlet 2 Install the Flexible Exhaust Hose and the Adjustable Window Slider Kit as depicted in Fig 7 Fig 7a NOTE Step 2 is required only while using the cooling mod
4. air conditioner It is normal NOTE When the pipe sensor the room sensor is error the digital display shows E1 or E2 accordingly 17 18
5. disappears Then operation panel comes back to the normal state INSTALLATION IMPORTANT Install the portable air conditioner in a flat and spacious location where the air inlets or outlets will not be blocked A minimum clearance of 12 inches from a wall or other obstacles should be kept as Fig 9 show The appliance shall not be used in the laundry The plug shall be accessible after the appliance is positioned Wiring shall be done according to National rules DUCT MOUNT INSTRUCTIONS Bxhausl air Fig 10 A TEMPORARY 1 Attach one end of the duct to the exhaust air outlet of the mobile air conditioner first fit the left side of the duct on the exhaust air panel then the right side duct Push it downwards be sure to fix thoroughly See the fig 10 2 Put the end of duct to a nearby window Window Kit Installation Your window kit has been designed to fit most standard Vertical and horizontal window applications However it may be necessary for you to improvise modify some aspects of the installation procedures for certain types of window Please refer to Fig 11 amp Fig 11a for minimum and maximum window openings Window sider kit mim 67 5 0 22 0 123 44 0460 Window sider kit 67 5 2 220 123 44 04 1 Fig 11 Fig lla Drain Tank Safety Feature This unit is equipped with a internal water tank two full safe switch mechanisms one is used to co
6. this setting Keep windows and doors closed for the best dehumidifying effect 4 HEATING OPERATION not available for cooling only type air conditioner Connect the power and press the ON OFF button Press the MODE button several times until the heating indicator light comes on Press the TEMP SETTING button A or to select your desired room temperature 60 89 Press the FAN SPEED button to choose the fan speed Auto High Medium Low The fan will delay to be off for a few minutes when the AUH has been off 5 FAN OPERATION Connect the power press the ON OFF button Press the button several times until the fan indicator light comes on Press the FAN SPEED button to choose the fan speed High Medium Low 6 TIMER OPERATION Setting the on timer Press the TIMER ON button or TIMER button when the air conditioner is off Press the TEMP SETTING button A or Y to select the time you need turn on the unit The starting time is adjustable from 01 to 24 The operation paned window will display CPN or the timer on indicate light Setting the off timer Press the TIMER OFF button when the air conditioner is on Press the TEMP SETTING button A or Y to select the time you need turn off the unit The turning off time is adjustable from 01 to 24 The operation paned window will display CDF F or the timer off indicate light WATER
7. IES 1 UNIT DOES NOT START WHEN PRESSING ON OFF BUTTON Water full indicator blinks water tank is full Dump the water in the water tank Room temperature is higher Reset the temperature than the set temperature Heating mode Room temperature is lower Reset the temperature than the set temperature Cooling mode LCDI plug was tripped Press the reset button on the LCDI plug Press On Off button on the air conditioner 2 NOT COOL ENOUGH The windows or doors in the room are not closed Make sure all the windows and doors are closed There are heat sources inside the room Remove the heat sources if possible Exhaust air duct is not connected or blocked Connect the duct and make sure it can function properly For best performance keep as short and straight as possible Temperature setting is too high Decrease the set temperature Air filter is blocked by dust Clean the air filter AC stopped cooling after checking each item above Turn unit off for 3 minutes press the reset button on the LCDI plug turn the AC back on and select a temperature than the lower room temperature 3 NOISY OR VIBRATION The ground is not level or not flat enough Place the unit on a flat level ground if possible 4 GURGLING SOUND The sound comes from the flowing of the refrigerant inside the
8. MOBILE AIR CONDITIONER USER S MANUAL Read Rules for Safe Operation and Instructions Carefully CONTENTS oDARETY RULES 5 ee ee 2 NAME OW PARTS sacs tects s soge UE EESO 3 Eo EEE E E oA EEE 3 OPERATION PANEL OF THE AIR CONDITIONER 4 5 OPERATION INDICATION SECTIONS OF REMOTE CONTROLLER EAE E 6 7 OPERATION ME VEO Diss ssa ied 8 10 KEY OPERATING INSTRUCTION FOR THE AIR CONDITIONER 22 11 13 TALEATION tthe 13 15 gt MAINTENANCE seen ey 15 10O TROUBLESHOOTING GS ato ee ete 16 SAFETY RULES 1 Do not connect unit to any AC socket in disrepair 2 Do not use in the following locations A Next to source of fire B An area where oil is likely to splash C An area exposed to direct sunlight D An area where water is likely to splash E Near a bath a shower or a swimming pool 3 Never insert your fingers or any foreign objects into the air outlet Take special care to warn children of these dangers 4 Always store the unit upright in order to maintain the compressor in a proper condition 5 Be sure to unplug the unit before cleaning 6 The heater must not b
9. PUMP DRAINAGE Connect the water pump drain hose to the unit before operating When the water level of the internal water tank reaches a predetermined level the water pump will be activated and drain the condensed water outside through the connected drain hose The maximum delivery lift is 3 0m 10 feet Under this condition ensure the rubber stopper is attached to continuous drainage plug at the bottom of the unit 13 This is located on the back side of the AC 8 CONTINUOUS DRAINAGE l 2 When you plan to leave this unit unused for long time or do not want to use the water pump remove the rubber stopper from the continuous drainage plug and attach a tube or hose for continuous drainage All the water in the water tank will drain once the continuous drainage plug is removed Under this condition the water pump is not activated NOTE 1 This type of air conditioner s waterproof level is Do not use it in the laundry or bathroom Fuse RF1 20 250V or F3 15AL250V rated current 5A or 3 15A 3 The rules of line must accord with the standard of exporting countries or nations 4 Seconds after pressing UP and DOWN simultaneously operation panel is locked and the displayer shows LOCKED All buttons on operation panel are invalid but the remote controlling signals are valid Pressing and DOWN simultaneously the operation panel is unlocked and the LOCKED on displayer
10. e Fig 7 Fig 7a 3 Plug the unit into the grounded electrical outlet 4 Make sure the water pump drain hose is correctly installed as Fig 8 5 Press the on off button to turn on the unit draio bose 1 BEFORE USE Made sure the duct is installed well Dehumidifying and Cooling Operations The operating range for dehumidifying is 60 89 the operating range for cooling operating is 60 89 Ifthe cooling or dehumidifying operations have been switched off and need switching on again a short time allow approximately three minutes for the cooling or dehumidifying operations to resume Make sure the water pump drain hose is correctly connected to the unit 12 Power supply Insert the plug of the air conditioner into a standard three prong outlet 2 COOLING OPERATION Connect the power and press the ON OFF button Press the MODE button several times until the cooling indicator light comes on Press the TEMP SETTING buttons VW to select your desired room temperature 60 89 Press the FAN SPEED button to choose the fan speed Auto High Medium Low 3 DEHUMIDIFYING OPERATION Connect the power and press the ON OFF button Press the MODE button several times until the dehumidifying indicator light comes on Press the TEMP SETTING buttons WV to select your desired room temperature 60 89 The fan will often run at a fixed low speed at
11. e located immediately below a socket outlet 7 Ifthe appliance is covered there is a risk of overheating 8 Ifthe plug or electrical cord is damaged it must be replaced by a repair shop appointed by the manufacturer because special purpose tools are required NOTE The air conditioner can be connected only a supply system impedance of no more than 0 4582 ohm If unsure please consult your supply authority for system impedance information NAME OF PARTS REAR COVER OPERATION Pree PANEL AIR OUTLET So T N WATER PUMP RADIE DRAIN HOSE CONTROLLER AIR INLET POWER CORD CASTER FRONT VIEW SIDE VIEW Fig 1 ACCESSORIES PARTS PARTS NSTALLTION PLATE WATER PUMP DRAIN HOSE Fig 2 AIR INLET AIR OUTLET AIR INLET CONTINUOUS DRAIN HOSE REAR VIEW QUANTITY Check all the accessories are included in the package and please refer to the installation instructions for their usage OPERATION PANEL OF THE AIR CONDITIONER i model display indicators with electricity heating ly light set e e Fig 3 ii model display indicators only cooling O Light Set Fig 4 e B model display indicators Display S 4 N 2 N 2 SWING FAN SPEED MODE TIMER UP DOWN ON OFF POWER WATER FULL Receiver Fig 5 DISPLAY Locked indicate Auto mode i
12. n using the remote controller please point the signal emitter towards the air conditioner receiver There should be no obstacles between the remote controller and the air conditioner Do no press two buttons simultaneously the remote control Do not use wireless equipment such as mobile phone near the air conditioner If interference occurs because of this please switch off the air conditioner pull out power plug then plug again and switch on after a while Ifdirect sunlight is hitting the the receiver on the air conditioner it may not be able to receive the signal from the remote controller Take care not to drop theh remote control and keep from direct sunlight or heat sources Keep the remote control dry if it gets wet use a soft dry cloth for cleaning The batteries must be removed from the remote control before it is scrapped and disposed of safely OPERATION METHOD AUTO HEAT COOL FAN and DRY operation SLEEP ON OFF TEMPERATURE Setting Operation Mode Heat Sweep A Cool Dry Temp Adjustment Buttons Press A VY buttons to set temp as needed Switch On Press ON OFF button to start air conditioner Airflow selection Press FAN SWEEP button to select 4 airflow direction MODE AUH C Remarks Setting Fan Speed Four speeds can be selected
13. ndicate Fan speed Heating mode indicate mode indicate XX Swing indicate Cooling mode indicate Timer indicate Digital display Fig 6 Note 1 The Auto Cooling Heating Dry mode indicators will not display in the Fan mode 2 The relevant display light according the set content by remote controller 3 Air conditioner does not operate normally when set temperature indicator displaies unnormally please contact with the distributor for service lt lt Could you remove 2 3 above I do not understand what they mean gt gt 6 OPERATION OF THE REMOTE CONTROL ON OFF Button Press this button to start stop air conditioner Display Screen For setting display Sleep Button Temp Adjustment Buttons Press Y to decrease temp Press A to increase temp For setting sleep function Mode selection Button For selecting AuUToQ HEAT CooL pry Fan speed button For selecting indoor fan speed SWEEP oe Auto Medium 9 TEMPERATURE High Low AUH Button MODE RAN SPEED Airflow sweep Button To change the condition of starting For changing louver osition auxiliary electric heater when air gt F Co p conditioner in HEAT mode TIME TIMER Timer selection Button CD Selecting procedures On timer Off timer Program control Timer cancelled timer Time setting Button Press this button t
14. ntrol the water pump drainage the other is used to monitor the water level inside the internal water tank When the water level reaches a predetermined altitude the digital display shows E5 and the water full indicator light illuminates Cut off the power and move the unit outside carefully remove the rubber blockage from the back drainage hole and drain the water off The unit will continue operating properly 15 MAINTENANCE IMPORTANT 1 BE SURE TO UNPLUG THE UNIT BEFORE CLEANING 2 DONOTUSE GASOLINE THINNER OR OTHER CHEMICALS TO CLEAN THE UNIT 3 DO NOT WASH THE UNIT DIRECTLY UNDER A TAP OR USING A HOSE 4 IFTHEPOWER CORD IS DAMAGED IT SHOULD BE REPAIRED BY MANUFACTURE OR ITS AGENCY 7 Fig 12 1 AIR FILTER Clean the air filter at least once every two weeks to prevent inferior fan operation from dust build up Removal Pull out the filter cover and remove the air filter from the filter cover cleaning Wash the air filter by immersing it gently in warm water about 104 with a neutral detergent Rinse the filter and dry it in a shady place Mounting Attach the air filter to the filter cover using the attachment hooks on the inner surface of the cover Put the filter cover back to the unit 2 UNIT ENCLOSURE Use a lint free cloth soaked with neutral detergent to clean the unit enclosure Finished by dry clean cloth TROUBLE SHOOTING 16 PROBLEM POSSIBLE CAUSES SUGGESTED REMED
15. o set timer or the clock time Minute Button Press this button to change the minute setting Hour Button Press this button to change hour setting Reset Button Reset remote control to the original status XQ Remarks Temperature can be set between60 89 Remote Controller Display Operating Mode Selection Display Signal Emission AUH Display Timer setting AUTO See HEAT Symbol It appears when pressing the key is add in HEAT It appears when control signal 15 emitted COOL DRY FAN Wind Speed Selection Display sure Auto High speed Medium speed 3 Low speed Time Display Displays the time of clock or timing ON OFF Air refresh Display Not available Display displayed when temp is displayed Sleep Mode Display Displayed when Pressing SLEEP button the unit will enter into sleeping operation Instructions for the remote controller The remote controller uses two AAA alkaline battrries Under normal condition the batteries last for about 6 months Please use two new batteries of similar type pay attention to the poles in installing After replacing the batteries please use a point object such as pen tip to press Reset button The effective control distance of the remote controller is about 8 yards Whe

Download Pdf Manuals

image

Related Search

Related Contents

  PZBシリーズ電動ベッドをお買い上げ頂きまして  Livres numériques disponibles à la Bibliothèque  Intimidator Scan-Barrel 305 IRC QRG Rev3 ML  Slate” - Cabinet COUBRIS, COURTOIS et Associés  MIPS32® M14K™ Processor Core Software User`s Manual  Motorola RADIUS GM300 User's Manual  コアグチェックXSプラス クリックリファレンスガイド  Brinkmann Gas Grill King User's Manual  Tilia V2040  