1. Unit in Test e g Loopback with an alarm present on the DS3 Interface When displayed on the OCM at the CO indicates acknowledged active alarms at the RT When displayed on the OCM at the CO indicates an unacknowl edged active alarms at the RT Acknowledged alarms active on the shelf Unacknowledged alarms active on the shelf reach 3rd party equipment the optical receive signal may need to be padded to avoid overloading the optical receive signal The receive signal level should be within 8 dbm to 28 dbm for IR equipment PRICING AND AVAILABILITY 800 827 0807 TECHNICAL SUPPORT 800 726 8663 RETURN FOR REPAIR 256 963 8722 www adtran com 61184002L4 22B TOTAL ACCESS OPTI 3 CONTROLLER MODULE 1550 NM SNMP Write Community Time and Date Mount Location Account Provisioning Remote Alarm Reporting Public Private User Defined Central Office Remote Subtended Account 1 14 Username Password Permission Enabled Disabled Option is available only in Central Office mode PROVISIONING OPTIONS Upon initial installation the OCM uses factory default settings To provision the OCM connect a terminal emulator via the RS 232 DB 9 connector on the front panel The terminal must be VT100 compatible and set for 9600 bps 8 data bits no parity and 1 stop bit The following table lists the provisioning settings and their default values The settings are retained in a nonvolatile memory device in case of power loss
2. OPTI 3 ILJ ADRA CONTROLLER GE 1550nm CLEI SOI4JN4D_ _ eeceeq TET A0 D SCS S E ni z TOTAL ACCESS OPTI 3 CONTROLLER MODULE 1550 NM OPTI 3 118400214 DESCRIPTION The Total Access OPTI 3 Controller Mod y 6 1 1 8 4 Q Q 2 L 4 z 2 2 B ule OCM provides an OC 3 interface to the network and three ADD DROP DS3 interfaces to the Loop The OCM can be configured for a point to point configuration or subtended from 3rd party SONET equipment The OCM operates in terminal mode only The compact design mounts in either a rackmount or wallmount chassis requiring less space and provides optional redundancy It can automatically switch to the offline unit in the event of optical signal failure or degradation The modules are fully hot swappable Compliant with SONET standards the OCM functions as a terminal multiplexer It supports 1 1 OC 3 equipment and facility protection 1 1 OC 3 equipment protection system provisioned for optical Ycable 1 1 DS3 facility protection and detects standard optical related alarm conditions The OCM can be configured to operate redundantly with optional protection of the optics components It can be upgraded online from un protected to protected and operating software can be upgraded remotely in Back to Back configurations The OCM is easily managed with TL1 commands over the Data Communications Channel DCC or via Command Line Interface CLI through the local craft interface Additio
3. LI Code NSAP Area Address LAPD Window Size LAPD T200 Value LAPD 1203 Value LAPD N200 Value LAPD N201 Value Network Configuration Baud Rate Screen Height Screen Width Ethernet Interface IP Address Subnet Mask Default Gateway SNMP Trap Hosts SNMP System Name SNMP System Location SNMP Read Community Network User Option is available when Mount Location is Subtended User Defined User Defined up to 20 alphanumeric characters User Defined Option is available when Mount Location is Subtended 1 7 127 Option is available when Mount Location is Subtended 200 20000 Option is available when Mount Location is Subtended 4000 10000 120000 Option is available when Mount Location is Subtended 2 3 16 Option is available when Mount Location is Subtended 512 1500 Option is available when Mount Location is Subtended 9600 19200 38400 57600 115200 20 24 9999 40 80 9999 Enable Disable User Defined Format x x x x where x 0 255 User Defined Format x x x x where x 0 255 User Defined Format x x x x where x 0 255 User Defined Format x x x x x4 User Defined User Defined Public Private Restore Factory Defaults Restore Management Defaults LINKED PROVISIONING The online unit s provisioning settings are written to the standby unit Linked Provisioning is always enabled DCC MODES 1 Back to Back Mode Back to Back mode is used when OCMs are connected together i
4. ce the STATUS LED illuminates green If installing a redundant system repeat the preceding procedure for slot B If not installing a second OCM a blank faceplate P N 1184005L1 must cover the empty slot CAUTION SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY HANDLING PRECAUTIONS REQUIRED Rack Mount N Tila Access RME Slot B protect card Slot A ki rd working card Wall Mount Slot B protect card Slot A working card _ LED STATUS STATUS OPTICS Green Yellow Flashing Yellow Red Green Yellow Flashing Yellow Red Flashing Red DS3 1 DS3 3 Green ACO Yellow Flashing Yellow Red Flashing Red Yellow Flashing Yellow Red Flashing Red APS PUSHBUTTON m When depressed simultaneously with the TEST ENABLE switch on the Offline unit a switch is forced between the two OCMs m When depressed with the TEST ENABLE switch on the Online unit it toggles LOCKOUT status _ TEST ENABLE BUTTON m When depressed alone tests all unit LEDs multicolor LEDs appear YELLOW m When depressed simultaneously with the APS switch on the Offline unit a switch is forced between the two OCMs ACO BUTTON m When depressed after an audible alarm is sounded silences the alarm m When depressed after any other alarm is triggered acknowledges alarm CRAFT INTERFACE m Provides menu access via RS 232 Craft port on the front pane
5. erference that may cause undesired operation Changes or modifications not expressly approved by ADTRAN could void the user s authority to operate this equipment
6. l Connects to VT100 compatible terminal using a DB 9 serial cable m Requires setting VT100 terminal emulation to 9600 19200 38400 57600 or 115200 bps 8 Data Bits No Parity 1 Stop Bit and No Flow Control The baud rate default is 9600 bps which can be modified through the VT100 menu system m Provides access to both OCMs installed in the chassis with connection to either OCM craft port NOTE The OPTI 3 is an LR long reach optical product When interfacing with IR intermediate WARRANTY ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service Warranty information can be found at www adtran com warranty U S and Canada customer Faxback 877 457 5007 Document 414 m For a complete Installation and Maintenance Practice P N 61184002L4 5 877 457 5007 Faxback Document 964 Please have your fax number ready E JOBAID 61184002L4 22B 0401 In Service Unit is Out of Service Unassigned Unit is Out of Service Maintenance or is ONLINE and inhibited from switching Unit has an equipment failure Normal Operation Soft failure e g RDI Unit in Test e g Loopback LOS LOL and other hard alarms on optical interface Unit in Test e g Loopback with an alarm present on the Optical Interface Unit is ONLINE DS3 TX ON Soft failure e g RDD Unit in Test e g Loopback LOS LOL and other hard alarms on DS3 interface
7. lation and Maintenance Practice P N 61184002L3 5 for details and options SOFTWARE UPGRADE Software downloads for the local OCM are provided using TFTP XModem and YModem protocols in any DCC mode Software downloads to the remote OCM through the CO OCM is only supported in a Back to Back mode TFTP downloads are provid ed through the Ethernet interface provided through the rear of the chassis or over the DCC channel TFTP over DCC channel only provided when configured for Back to Back mode XModem and YModem downloads are provided through the craft port and Telnet connections Code Input Output COMPLIANCE Power Code PC F C Telecommunication Code TC WARNING The 10 100baseT interface and DS3 interfaces MUST NOT be Installation Code IC A metallically connected to interfaces which connect to the Outside Plant or its wiring These interfaces are designed for use as intra building interfaces only The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring This product intended for use in Restricted Access Areas only and is intended to be installed in a Type B or E enclosure This product complies with UL 60950 This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including int
8. n a point to point setup It consists of one OCM configured for Central Office and the other for Remote This mode of operation supports accessing the remote OCM menus either by the CO craft port or the CO Ethernet LAN via Telnet This remote management is carried over the DCC section on the fibers between the OCMs This mode of operation supports remote management of other ADTRAN equipment subtended from the OCM at the remote site TFTP and SNMP are supported in this mode both on a local Ethernet access and to the remote OCM NMA access is supported with TL1 via Telnet where NMA can access both devices via the CO TL1 session CO acts as GNE 1 IP address assigned 2 Subtended Mode The OCM functions as a full SONET terminal multiplexer in a new or existing SONET network It consists of one OCM configured for Subtended mode This mode allows each OCM to directly connect to SONET backbone equipment Management access is also provided over the DCC to other network elements on the SONET ring The DCC Interface must be properly configured LAPD parameters and NSAP Area Address for the SONET network for remote OCM management The OCM can be also used as a GNE device to allow TL1 access to the existing SONET network PROVISIONABLE ALARMS 1 Regular Alarms lt Regular Alarm List 27 available choices gt 2 Threshold Alarms lt Threshold Alarm List 22 available choices gt 3 Environment Alarms 4 Restore Alarm Defaults NOTE Refer to the Instal
9. nal features include remote alarm transport via DCC and alarm reporting to legacy alarm systems _ FIRMWARE RELEASE This job aid relates to OPTI 3 System Release 1 3 Dseries The menus and functionality are an extension of the prior system release OPTI 3 System Release 1 2 Cseries The latest software is not compatible with System Release 1 1 Bseries INSTALLATION The Total Access OPTI 3 can be installed in either a Rackmount Chassis RMC P N 1184003L1 or a Wallmount Chassis WMC P N 1184001L1 The RMC provides two OCM slots side by side with slot A on the left and slot B on the right See Figure below The WMC provides two OCM slots positioned vertically with slot A below slot B Ensure the appropriate chassis is installed before proceeding with the OCM installation Carefully insert the OCM halfway into the selected slot Route the fiber cables through the notch on the OCM front panel and approximately 4 inches past the SC receptacles to create slack Gently but firmly push the OCM all the way into the slot being careful not to pinch the fibers between the front panel and the shelf Push the latch ejector tab toward the front panel to lock it into place WARNING Once fully inserted into the chassis the module will be powered provided power is connected to the chassis When the OCM powers up it performs a self test The front panel LEDs illuminate for approximately 8 seconds The self test is complete on
10. to the OCM TL 1 Server Enabled Disabled TL 1 Port 256 2001 2999 Note TL 1 Port and Menu Port cannot be the same value TL 1 Echo On Of Working Service State In Service Out Of Service Maintenance Out Of Service Unassigned Menu Server Enabled Disabled Protect Service State In Service Out Of Service Maintenance Out Of Service Unassigned Menu Port 23 2999 Note TL 1 Port and Menu Port cannot be the same value DS3 Provisioning DS3 1 Name DS3 1 Interface DS3 1 Line Build Out DS3 2 Name DS3 2 Interface DS3 2 Line Build Out DS3 3 Name DS3 3 Interface DS3 3 Line Build Out Signal Fail SF Thresh Signal Degrade SD Thresh Provisionable Alarms Clock Source TX OC3 TX SYNC MSG User Defined Enable Disable Short Long User Defined Enable Disable Short Long User Defined Enable Disable Short Long 1x10 3 1x1074 1x10 1x109 1x10 1x10 7 1x10 8 1x10 9 See the Provisionable Alarms section to the right of this table 1 Receive OC 3 from both Fiber A amp Fiber B Receive OC 3 from Fiber A Receive OC 3 from Fiber B Free Run External DS1 SF or ESF from both inputs External DS1 SF or ESF from Primary input External DS1 SF or ESF from Secondary input External DS1 ESF w Sync from both inputs External DS1 ESF w Sync from Primary input External DS1 ESF w Sync from Secondary input Derive From Source Don t Use Ss Oamnonrwn Oo DCC Provisioning DCC Service State DCC IP Address CL