1. LIMITED ONE YEAR WARRANTY Chaney Instrument Company warrants that all products it manufactures to be of good material and workmanship and to be free of defects if properly installed and operated for a period of one year from date of purchase REMEDY FOR BREACH OF THIS WARRANTY IS EXPRESSLY LIMITED TO REPAIR OR REPLACEMENT OF DEFECTIVE ITEMS Any product which under normal use and service is proven to breach the warranty contained herein within ONE YEAR from date of sale will upon examination by Chaney and at its sole option be repaired or replaced by Chaney In all cases transportation costs and charges for returned goods shall be paid for by the purchaser Chaney hereby disclaims all responsibility for such transportation costs and charges This warranty will not be breached and Chaney will give no credit for products it manufactures which shall have received normal wear and tear been damaged tampered abused improperly installed damaged in shipping or repaired or altered by others than authorized representatives of Chaney THE ABOVE DESCRIBED WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED AND ALL OTHER WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE CHANEY EXPRESSLY DISCLAIMS ALL LIABILITY FOR SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES WHETHER ARISING IN TORT OR BY CONTRACT FROM ANY BREA
2. amp Warranty Enclosed Customer Care 877 221 1252 www chaneyinstrument com ew ar ee Patent numbers 5 978 738 6 076 044 6 597 990 US 7 637 141 B2 ACURITE is a registered trademark of the Chaney Instrument Co Lake Geneva WI 53147 15
3. of time Follow the polarity diagram in the battery compartment Promptly remove dead batteries from the device Dispose of used batteries properly Only batteries of the same or equivalent type as recommended are to be used DO NOT incinerate used batteries DO NOT dispose of batteries in fire as batteries may explode or leak DO NOT mix old and new batteries or types of batteries alkaline standard DO NOT use rechargeable batteries DO NOT recharge non rechargeable batteries DO NOT short circuit the supply terminals 5 Main Unit Basic Setup After installing batteries it is recommended that you set the clock and calendar initially After the atomic clock signal is acquired which may take up to 24 hours the clock accuracy and daylight saving time changes will be automatically maintained To set the clock and other preferences press AND HOLD the SET button for 5 seconds to enter into SET MODE Once In set mode the preference you are currently setting will blink on the display To adjust the currently selected flashing preference item press the button press and HOLD to fast adjust To save your adjustments press the SET button again to move on to adjusting the next preference The preference set order is as follows TIME ZONE PST MST CST EST DST Daylight Saving Time ON OR OFF CLOCK HOUR CLOCK MINUTE YEAR CALENDAR MONTH CALENDAR YEAR You will automatically exit SET MODE if no butto
4. the diocles console A typical installation would involve mounting the bracket to a secured length of 2x4 or 4x4 wood not included LEVEL INSTALLATION DO Install the wireless multi sensor as level as possible to ensure accurate wind measurements Use a bubble level not included to help ensure a level installation 11 SECTION 4 e PLACEMENT Troubleshooting Possible Solution FENCE POST OR SIMILAR MOUNTING RAILING OR SIMILAR MOUNTING Relocate the main unit and or the wireless sensor Both units must be within 330 feet Bad 100 m from each other Make sure both units are placed at least 3 feet 91 m from other Wireless Sensor electronic appliances and devices that may Reception interfere with the wireless communication such as TV s microwaves computers etc NOTE It may take up to 20 minutes for the main unit to re synchronize with the sensor when batteries are replaced Use lithium batteries in sensor when temperature is below 4 F 20 C Rotate the wireless sensor 90 on its mount ing point to re orient the antennea Make certain there are no large stone or metallic Bad surfaces disrupting the signal line of sight to Atomic Clock the state of Colorado Make sure the main unit and wireless sensor are placed at least 3 Reception feet 91 m from other electronic appliances and devices that may interfere with the wireless communication such as TV s no bars microwaves computers etc Larg
5. window which will automatically display the current moonphase provided the calendar is set properly O D DOG WAXING 1ST WAXING FULL WANING 3RD WANING CRESCENT QUARTER GIBBOUS GIBBOUS QUARTER CRESCENT Main Unit MIN MAX Memory This wireless weather station features a MIN MAX memory feature which records the MINIMUM and MAXIMUM indoor amp outdoor temperature and humidity readings To view the MINIMUM temperature and humidity readings press and release the MIN MAX button Note the MIN icon on the display To clear the MIN recorded values press and hold the and SCALE buttons simultaneously for 3 seconds while in the MIN view mode Dashes will display in the display to confirm you have cleared the MIN values for outdoor temperature and indoor temperature humidity To view the MAXIMUM temperature and humidity readings press and release the MIN MAX button Note the MAX icon on the display To clear the MAX recorded values press and hold the and SCALE buttons simultaneously for 3 seconds while in the MAX view mode Dashes will display in the display to confirm you have cleared the MAX values for outdoor temperature and indoor temperature humidity e SECTION 4 PLACEMENT MOUNT IN AN OPEN AREA FOR UN OBSTRUCTED WIND SPEED MEASUREMENT 330 feet 100 meters Now that setup is complete and you understand how to operate the weather station you m
6. CH OF THIS WARRANTY SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU CHANEY FURTHER DISCLAIMS ALL LIABILITY FROM PERSONAL INJURY RELATING TO ITS PRODUCTS TO THE EXTENT PERMITTED BY LAW BY ACCEPTANCE OF ANY OF CHANEY S EQUIPMENT OR PRODUCTS THE PURCHASER ASSUMES ALL LIABILITY FOR THE CONSEQUENCES ARISING FROM THEIR USE OR MISUSE NO PERSON FIRM OR CORPORATION IS AUTHORIZED TO ASSUME FOR CHANEY ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF ITS PRODUCTS FURTHERMORE NO PERSON FIRM OR CORPORATION IS AUTHORIZED TO MODIFY OR WAIVE THE TERMS OF THIS PARAGRAPH AND THE PRECEDING PARAGRAPH UNLESS DONE IN WRITING AND SIGNED BY A DULY AUTHORIZED AGENT OF CHANEY THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE For in warranty repair please contact Customer Care Department Chaney Instrument Company 965 Wells Street Lake Geneva WI 53147 This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may NOT cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to prov
7. Future Forecast Icon The future forecast feature automatically gives you the predicted weather forecast icon for the next 12 to 24 hours based on an advanced algorithm that analyzes barometric pressure changes and temperature This weather forecaster will provide the most accurate forecast that a single station instrument can provide rain or snow rain or snow SS lt gt O OS ry Ce Gor OCS x Oe re EE HE HLE E HEAVY STORM STORMY MOSTLY CLOUDY MOSTLY SUNNY heavy stormy stormy conditions mostly cloudy mostly sunny weather are forecasted conditions conditions conditions are next 12 24 hours are forecasted are forecasted forecasted next 12 24 hours next 12 24 hours when flashing l SECTION 3 e OPERATION Wind Speed Data Window This weather station features an advanced wind speed data window that provides the wind speed the peak value and the average value i Tuil l 3 EF 3 H H WIND SPEED most current wind speed reading this value is updated every 18 seconds E PEAK the highest wind speed reading recorded in the last hour Bmg AVERAGE the combined averaged wind s speed readings from the last 2 minutes NOTE The wireless sensor must be placed outdoors to observe outdoor wind speed Seasonal Window wind chill dew point heat index This weather station features a Seasonal window which will automatically display the wind chill the dew point or the heat index informa
8. at must be removed prior to using this product Locate the pull tab and simply peel to remove i SECTION 1 OVERVIEW OF FEATURES MAIN UNIT ATOMIC CLOCK Automatically maintains accuracy and resets for daylight saving time ATOMIC CLOCK Atomic clock signal reception indicator BAROMETRIC PRESSURE FUTURE FORECAST Current value with trend Self calibrating indicator weather forecast xe Moonphase WIND SPEED CO Current wind speed Peak wind speed Average wind speed SEASONAL og WIRELESS SENSOR INFORMATION Ne Low Battery indicator Heat Index Dew Point INDOOR CONDITIONS Wind Chill Temperature amp Humidity automatic WIRELESS SENSOR OUTDOOR CONDITIONS D Temperature amp Humidity with Trend Indicators HISTORY GRAPH Wireless reception indicator last 12 hours of Setup and Operation Barometer Buttons Outdoor Temperature Wind Speed Tabletop Placement user selectable Display Stand WIRELESS SENSOR Wind speed anemometer A temperature a and humidity P housing release lever battery access remove lower o hous SURFACE mounting s 9 MOUNT point BRACKET E About the Atomic Clock A clock is considered atomic if it has an accuracy of one second in a million years Consumer clocks are considered atomic if they attain this accuracy by receiving a signal from an atomic clock In North America the National Institute of Standards and Technol
9. communication to take place successfully Battery Choice amp Temperature Range Extended periods of cold temperatures below 4 F 20 C can cause alkaline batteries to function improperly This will cause the outdoor wireless sensor to stop transmitting temperature readings Use lithium batteries in these low temperature conditions to ensure continued operation for wireless sensors placed outdoors NOTE Rechargeable batteries are not recommended due to higher operating voltages i 70 C 158 F BATTERIES md meee oc 158 F e LITHIUM PPP BATTERIES mah A SRO Install Batteries Wireless Sensor 4 AA Batteries Required tnot included SET ABC SWITCH TO MATCH ABC DISPLAY CONSOLE ABC SWITCH SELECTION Remove Battery Compartment Cover Install 4 AA Alkaline Batteries install lithium batteries for use In temperatures below 4 F Install Batteries Main Unit 3 AA Batteries imorn Q SET ABC SWITCH TO MATCH mm SENSOR ABC SWITCH SELECTION Remove Battery Compartment Cover P Install 3 AA Alkaline Batteries PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS BATTERY SAFETY Clean the battery contacts and also those of the device prior to battery installation Remove batteries from equipment which is not to be used for an extended period
10. e metallic surfaces will interfere with the atomic clock signal INCLUDED MOUNTING INCLUDED BRACKET MOUNTING BRACKET No Wireless Sensor Data If wireless reception is bad no bars see a Bad Reception section above The wireless no communication ID setting on each unit must match for all no bars and flashing units to communicate properly See Set antenna icon Wireless ID on the previous page Mount the sensor onto a 3 4 schedule 40 PVC 25 8 mm O D pole not included PVC plastic pipe is recommended over a creel pipe due to lower risk of lightening strikes Make certain that the batteries are installed Main Unit correctly and that they are contacting the Display Not Working terminals Make certain all contacts are clean The batteries may need replacing Insert the pole completely into the bottom of the wireless sensor Use the included screw to securely mount the sensor so it MOUNTING will not fall or slide off of the pole in high BRACKET winds NOT USED INCLUDED Use caution when installing sensor or l erecting the pole Do not install during Please DO NOT return product to the retail store i For technical assistance and product return information please call Po EN electrical storms Do not place pole or e p p INCLUDED sensor near electrical transmission lines or dah electrical equipment Customer Care 877 221 1252 Mon Fri 8 00 A M to 4 45 P M CST www chaneyinstrum
11. ent com 13 Set Wireless ID This wireless thermometer uses long range 433mhz radio frequency for communication In the event that you have reception problems due to interference both the main unit and the wireless sensor have a selectable wireless ID The ID switches are located within the battery compartments of the main unit and the wireless sensor You may choose A B or C but both the main unit and the wireless sensor ID s must match for successful synchronization PRODUCT REGISTRATION Both wireless ID s must match Connect With Us For News lips and Videos www dcuriteweatherstation com To receive product updates SUPPORT and information Log on to www chaneyinstrument com Product Documentation Frequently Asked Questions FAQ Troubleshooting Product Registration X 14 Q Search keyword or item SECTION 5 e PRODUCT SPECIFICATIONS Product Facts Batteries 7 x AA not included Lithium Batteries Recommended in Outdoor Sensor if temperatures are below 4 F E ee Measurement Ranges Outdoor Temperature 40 F to 158 F 40 C to 70 C Outdoor Humidity 1 to 99 Wind Speed 0 to 99mph 0 to 159 kph Indoor Temperature 32 F to 122 F OPC 10 50 C Indoor Humidity 16 to 98 Wireless Range 330 ft 100 m MAX Depending on home construction materials MADE IN CHINA HECHO EN CHINA Limited One Year Warranty Instructions
12. hang the main unit on a wall using the integrated hang hole Alternatively you may place the main unit on a table top or other flat surface using the included detachable table top display stand 10 SECTION 4 PLACEMENT Placement of Wireless Sensor After installing batteries into the Wireless Multi sensor you must choose a location to install the sensor To ensure that your weather center performs at its best follow these guidelines to choose a mounting location for the wireless multi sensor INSTALL AWAY FROM HEAT amp HUMIDITY SOURCES DO NOT Place the wireless multi sensor near localized heat sources like heaters air conditioners chimneys and exhaust vents Install the wireless multi sensor away from asphalt or concrete as these surfaces radiate heat from the sun Also avoid installing the sensor near pools spas or other bodies of water as these water sources may affect the accuracy of the humidity INSTALL AWAY FROM SPRINKLER HEADS DO NOT install the wireless multi sensor where it will be directly sprayed by a sprinkler system this may force water into the housing WIND OBSTRUCTIONS DO consider a mounting location that has very little structures around the sensor to ensure proper wind speed measurements e INSTALLATION HEIGHT DO Mount the wireless multi sensor at least 5 feet off the ground higher is better for accurate wind measurements in an open area NO FURTHER than 330 feet 100 meters from
13. ide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used In accordance with the instructions may cause harmful interference to radio communications However There is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help NOTE The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment Such modifications could void the user authority to operate the equipment INST 00634 ACUDIeIT E SO LenTY rag Weather Center model 00634A1 Thank You for purchasing this ACURITE product Please read this manual in it s entirety to fully enjoy the benefits and features of this product Please keep this manual for future reference NOTE A protective film is applied to the LCD at the factory th
14. ns are depressed for 30 seconds You may enter basic setup mode again at any time by pressing AND HOLDING the SET button Main Unit Scale Selection The main unit is capable of displaying some values in an alternate scale mode To switch between modes press the SCALE button SCALE MODE 1 U S Standard Temperature F fahrenheit Barometric Pressure inHg inches of mercury Wind Speed Peak Average mph miles per hour SCALE MODE 2 Imperial Standard Temperature C Celsius Barometric Pressure hPa Hectopascall Wind Speed Peak Average kph kilometers per hour NOTE The WIND SPEED history mode chart will not change to kph scale it will remain displaying mph data Setup is Now Complete The wireless sensor will soon send a signal to the main unit and the two units will be synchronized It may take a few minutes for synchronization to be complete If both or one of the units appear to be functioning improperly refer to the troubleshooting section in this manual SECTION 3 e OPERATION 14 Day Learning Mode This weather station has a patented fourteen day learning mode calibration process During this learning mode the weather station will make altitude calculations that may affect the accuracy of the forecast Once the 14 day learning mode process is complete the learning mode icon will disappear and the weather forecast should be ready for Superior operation
15. ogies operates an atomic clock in Colorado which transmits the time codes via the radio station WWVB The Acurite product you have purchased includes a built in receiver which picks up the signal from the WWVEB station For the best possible reception place the main unit with the back side facing Colorado NOTE Due to solar radiation in the atmosphere the atomic clock signal is weaker during the day Most synchronization with the WWVB atomic clock signal happens at night when there is less interference About the Wireless Sensor This wireless weather center features a wireless sensor that provides wind temperature and humidity data and broadcasts this information to the main display unit This wireless sensor will provide accurate outdoor weather conditions when placed properly The wireless sensor contains sensitive electronic components and a balanced anemometer for wind speed measurement Care must be taken during setup and when considering placement to make certain the unit is not dropped or struck with any falling debris from trees or structures SECTION 2 e SETUP A B C Wireless Selection To allow for more than one weather station and wireless sensor network to be used in close proximity the main unit and the wireless sensor have a small switch labeled A B C within the battery compartments This switch selects one of 3 wireless modes to use and both switches MUST be set in matching positions either A B or C for wireless
16. tion when it Is relevant less than 40 F 4 C above 80 F 27 C WIND CHILL HEAT INDEX History Mode Graphing This weather station features a selectable history mode which will graph and display the changes for the last 12 hours 12 6 3 2 1 0 There are 3 selectable weather categories Barometer barometric pressure Temperature or Wind Speed Press the HISTORY MODE button to alternate through the 3 options Note the graphing icon all next to the currently selected data window BAROMETER hourly reading on the hour TEMPERATURE hourly outdoor temperature reading on the hour WIND SPEED hourly wind speed AVERAGE reading 8 SECTION 3 OPERATION Wireless Signal Reception Icons Tull The main unit has a signal reception icon in the outdoor wind speed temperature display area If most or all four of the bars are present wireless reception is good and no action is required If there are a low number of bars present you may experience wind speed temperature inaccuracy In either case you may need to relocate the main unit or the wireless sensor The main unit has a signal reception icon near the atomic clock display If the atomic clock signal bars are low the clock may be inaccurate or may not automatically adjust for daylight saving time DST Refer to the troubleshooting section in this manual If you are having reception issues Moonphase This weather station features a moonphase
17. ust choose a location to place the wireless sensor and the main unit The wireless sensor MUST be placed less than 330 feet 100 meters away from the main unit This wireless weather station uses radio frequency for communication which is susceptible to interference from other electronic devices and large metallic items or thick walls Always place both units at least 3 feet 91 m away from appliances TV microwave radios etc or objects that may interfere with the wireless communication large metal surfaces thick stone walls etc Please USE EXTREME CARE when handling the wireless sensor and the main unit The wireless sensor contains sensitive electronic components and a balanced anemometer for wind speed measurement Care must be taken during setup and when considering placement to make certain the unit is not dropped or struck with any falling debris from trees or structures USE CAUTION when utilizing tools or equipment for mounting the wireless sensor Enlist the help of another individual when necessary Placement of Main Unit Place the main unit in a dry area free of dirt and dust To help ensure an accurate indoor temperature measurement be sure to place the main unit out of direct sunlight and away from any heat sources or vents In your home For the best atomic clock signal reception place the main unit with the back side facing the state of Colorado There are 2 placement options for the main unit You may
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 LEISTER Examo Tensiometer GB USA OPERATING INSTRUCTIONS DB-87060 User Manual Version A1 October 2005 4ウェイタイプ 取扱説明書 Contec PPC-HDD(MS)A Computer Drive User Manual manual de instruções do alicate wattímetro modelo aw MEASUREMENT & SENSORS User guide Basal-bolus Insulin Dosing Chart: Adult Copyright © All rights reserved.