1. WARNING THIS PRODUCT CONTAINS A BUTTON CELL BATTERY IF SWALLOWED IT COULD CAUSE SEVERE INJURY OR DEATH IN JUST 2 HOURS SEEK MEDICAL ATTENTION IMMIDIATELY IF INGESTED POISON POISON LIMITED ONE YEAR WARRANTY Chaney Instrument Company warrants that all products it manufactures to be of good material and workmanship and to be free of defects if properly installed and operated for a period of one year from date of purchase REMEDY FOR BREACH OF THIS WARRANTY IS EXPRESSLY LIMITED TO REPAIR OR REPLACEMENT OF DEFECTIVE ITEMS Any product which under normal use and service is proven to breach the warranty contained herein within ONE YEAR from date of sale will upon examination by Chaney and at its sole option be repaired or replaced by Chaney In all cases transportation costs and charges for returned goods shall be paid for by the purchaser Chaney hereby disclaims all responsibility for such transportation costs and charges This warranty will not be breached and Chaney will give no credit for products it manufactures which shall have received normal wear and tear been damaged tampered abused improperly installed damaged in shipping or repaired or altered by others than authorized representatives of Chaney THE ABOVE DESCRIBED WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED AND ALL OTHER WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE
2. amp Maximum Records The display unit features Minimum amp Maximum records display mode The minimum and maximum values for indoor and outdoor temperature and humidity are recorded and kept until midnight every day when the records are reset for the next day Minimum Records To view the minimum records press the adjust down button w located on the back of the display unit The minimum recorded values will display for about 8 seconds note the icon indicating minimum records being displayed To manually reset the records being displayed press and hold the adjust down w button while viewing the records Maximum Records To view the maximum records press the adjust up button 4 located on the back of the display unit The maximum recorded values will display for about 8 seconds note the T icon indicating maximum records being displayed To manually reset the records being displayed press and hold the adjust up 4 button while viewing the records Momentary Backlight The display unit features a momentary blue backlight for easy night time viewing The button to activate the backlight is located on the very top edge of the display unit housing Pressing the button will give you about 10 seconds of illumination Note that excessive use of the backlight will reduce the battery life Momentary Backlight Button Atmospheric Pressure Atmospheric Pressure is defined as the p
3. weather device allows for calibration The forecast may be calibrated as well To calibrate the weather station you must enter into the calibration mode Calibration Mode To access the calibration mode press AND HOLD the a and w buttons together for at least 5 seconds After 20 seconds of inactivity the display will save your adjustments and automatically exit calibration mode and return to normal operation Calibrate the outdoor temperature by pressing the 4 or Y buttons Note the arrow icons indicate if you are calibrating the value above or below the uncalibrated raw temperature coming in from the sensor calibration E A a7 no calibration T 1 actual sensor reading ae Outdoor wl calibration Press the 1 button to confirm your calibration changes and move on to calibrating the outdoor humidity the indoor temperature and indoor humidity in the same manner After calibrating all of the temperature and humidity values the forecast is the final item to be calibrated If you feel that the forecast could be dialed in to be more accurate you may calibrate the forecast to be less or more wet Essentially calibrating the forecast will either reduce or increase how much moisture is present within the forecast software algorithm For example if you feel the forecast is showing rain too often you may want to remove 10 of the moisture from the forecast equation to start with P
4. 0 meters away from the display console This wireless forecaster uses radio frequency for communication which is susceptible to interference from other electronic devices and large metallic items or thick walls Always place both units at least 3 feet 91 m away from appliances TV microwave radios etc or objects that may interfere with the wireless communication large metal surfaces thick stone walls etc Slzy AT Mast i Re A eee 330 feet maximum APART 100 meters Placement of Display Console Place the display console in a dry area free of dirt and dust To help ensure an accurate indoor temperature measurement be sure to place the display console out of direct sunlight and away from any heat sources or vents in your home You may place the main unit on a table top or other flat surface using the integrated table top display stand Placement of Sensor The wireless sensor MUST BE PLACED OUTDOORS to observe outdoor temperatures The wireless sensor must be placed less than 330 feet 100 meters from the display console The wireless sensor is water resistant and is designed for general outdoor use However to extend the life of the product place the wireless sensor in an area protected from direct weather elements To ensure an accurate outdoor temperature measurement be sure the wireless sensor is placed out of direct sunlight and away from any heat sources There are 2 p
5. BACK OF THE DISPLAY TO SELECT YOUR GEOGRAPHIC REGION i IMPORTANT NOTICE Have questions about product setup or operation We re here to help 24 7 Support www acurite com gt Product Setup amp Demo Videos gt Register your Product selection can drastically affect the accuracy of the forecast Refer to CALIBRATION section of this manual for more options NOTICE The display may fail to start properly due to static discharge Press the reset button located on the back of the display unit to reset the entire unit gt Product Manuals gt Support Forum Frequently Asked Questions Submit Feedback amp Ideas EMAIL TOLL FREE info chaney inst com 8 77 221 1252 7 00 a m 7 00 p m CST Please DO NOT return product to the retail store cp For technical assistance and product return information please call i gt Customer Care 877 221 1252 Mon Fri 7 00 A M to 7 00 P M CST J www acurite com 1 Year Warranty b gt Don t forget Register your product at www acurite com SPECIFICATIONS Product Facts Batteries 5 x AA not included 2 Lithium Batteries Recommended in Outdoor Sensor if temperatures are below 4 F Measurement Ranges Outdoor Temperature 40 F to 158 F 40 C to 0 C Outdoor Humidity 1 to 99 Indoor Temperature 32 F to 122 F 0 C to 50 C Indoor Humidity 1 to 99 Wireless Range 330 ft 100 m MAX Depending on home con
6. IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE CHANEY EXPRESSLY DISCLAIMS ALL LIABILITY FOR SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES WHETHER ARISING IN TORT OR BY CONTRACT FROM ANY BREACH OF THIS WARRANTY SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU CHANEY FURTHER DISCLAIMS ALL LIABILITY FROM PERSONAL INJURY RELATING TO ITS PRODUCTS TO THE EXTENT PERMITTED BY LAW BY ACCEPTANCE OF ANY OF CHANEY S EQUIPMENT OR PRODUCTS THE PURCHASER ASSUMES ALL LIABILITY FOR THE CONSEQUENCES ARISING FROM THEIR USE OR MISUSE NO PERSON FIRM OR CORPORATION IS AUTHORIZED TO ASSUME FOR CHANEY ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF ITS PRODUCTS FURTHERMORE NO PERSON FIRM OR CORPORATION IS AUTHORIZED TO MODIFY OR WAIVE THE TERMS OF THIS PARAGRAPH AND THE PRECEDING PARAGRAPH UNLESS DONE IN WRITING AND SIGNED BY A DULY AUTHORIZED AGENT OF CHANEY THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE For in warranty repair please contact Customer Care Department Chaney Instrument Company 965 Wells Street Lake Geneva WI 53147 This device complies with part 15 of the FCC rules Operation Is subject to the following two conditions 1 This device may NOT cause harmful interference and 2 This device must accept any interference received including interference that may cause
7. e conditions to ensure continued operation for wireless sensors placed outdoors LITHIUM WPP BATTERIES mi A 70 C 158 F TA eee 70 C 158 F ALKALINE BATTERIES A B C Wireless Selection To allow for more than one weather station and wireless sensor network to be used in close proximity the display unit and the wireless sensor have a small switch labeled A B C within the battery compartments This switch selects one of 3 wireless modes to use and both switches MUST be set in matching positions either A B or C fore wireless communication to take place successfully Installing Batteries Wireless Sensor Remove the battery a compartment cover cr Install 2 fresh AA batteries as shown here NOTICE Cm A B C BATTERIES MUST BE INSTALLED FOR THE se SENSOR TO OPERATE SWITCH SELECTION MUST MATCH DISPLAY UNIT SWITCH SELECTION Installing Batteries Display Console Remove the battery compartment cover Install 3 fresh AA batteries as shown here S reset zone SWITCH SELECTION MUST MATCH WIRELESS SENSOR SWITCH SELECTION About the Self Setting Intelli Time Clock Your new weather station is equipped with Intelli Time technology which is pre programmed with the correct time and date Intelli Time technology instructs the clock to set itself once batteries are installed All you need to do is select your Time Zone and Daylight Sa
8. ireless Sensor Reception no bars Display Console Screen Not Working 5 Day Forecast displaying So 5 Day Forecast Relocate the main unit and or the wireless sensor Both units must be within 330 feet 100 meters from each other Make sure both units are placed at least 3 feet 91 m from other electronic appliances and devices that may interfere with the wireless communication such as TV s microwaves computers etc NOTE It may take up to 20 minutes for the main unit to re synchronize with the sensor when batteries are replaced Use lithium batteries in sensor when temperature is below 4 F 20 C Make sure the A B C switch selection in the battery compartments of the display unit and sensor match Batteries may need replacing Check that batteries are correctly installed Reset the display unit and wireless sensor The 5 Day Forecast will be learning and anylizing for the first five days after powering on or resetting During this initial learning mode the forecast will be less accurate The weather forecaster will always observe changes to learn your weather patterns and increase the accuracy of the forecast As with any weather forecast 100 accuracy is not possible However if the forecast seems wildly inaccurate make certain that your geographic region is selected properly The geographic region Forecast Geographic Region Selections AN PRESS THE GEO BUTTON LOCATED ON THE
9. lacement options for the wireless sensor You may hang it using one of the two integrated Bate holes or use string not included to hang it from a suitable location like a well covered tree branch 5 Day Forecast Initial learning mode The Precision 5 Day Forecast feature will be learning and anylizing for the first five days after powering on or resetting During this initial 5 Day learning mode the forecast will be less accurate The weather forecast will observe changes to learn your weather patterns and increase the accuracy of the forecast Forecast Display The Forecast display area gives you the predicted weather forecast for the next 5 days Each daily forecast will also display the predicted High and Low temperatures The forecast is always analyzing the available data and consistently updates the forecast icons and highs lows precipitation chance as time goes on This will help you to generally plan ahead for the next 5 days The weather forecast icon will display the predicted weather conditions Below is an example of some of the forecast icons SHEE TT GFA daa ai Rain Snow Stormy Windy Rain Likely Mix Likely C y g eN Gas an Mostl Partl Bunty Cloudy Cloudy Forecast Calibration If you feel that the forecast could be dialed in to be more accurate you may want to try calibrating the forecast See the Calibration section in the back of this manual for more information 7 Minimum
10. ling batteries the Intelli Time clock and calendar will automatically set to the correct time all you need to do is select your time zone PRESS THE zone BUTTON LOCATED IN THE BATTERY o COMPARTMENT TO SELECT YOUR TIME ZONE TIMEZONE NOTE IF FRENCH OR SPANISH LANGUAGE ARE SELECTED SEE DISPLAY CONSOLE MANUAL SETUP TO CHANGE REFERENCE LANGUAGE THE TIME ZONE SELECTION ON THE DISPLAY WILL BE G M T HOURS 4 Manual Setup Display Console Press the SET 44 button to enter into manual set mode The time zone will begin blinking To adjust the currently selected flashing preference item press and release the lt or v buttons To save your adjustments press and release the X button again to move on to adjusting the next preference The preference set order is as follows TIME ZONE PST MST CST EST AST HAST AKST AUTO DST Automatically adjust time on DST dates CLOCK HOUR CLOCK MINUTE CALENDAR MONTH CALENDAR DATE CALENDAR YEAR UNITS TEMPERATURE F or C UNITS PRESSURE inHg or hPa REFERENCE LANGUAGE English Spanish or French You will automatically exit SET MODE if no entries are made for 30 seconds You may enter basic setup mode again at any time by pressing and releasing the SET button 5 Now that setup is complete you must choose a location to place the wireless sensor and the display console The wireless sensor MUST be placed less than 330 feet 10
11. or Tull Next 12 24 Hours i i lt lt P J Jm Si no C998 learning mode WED DEN 4 4 50 SBT LO HI ACUDRITE Weather Station with 5 Day Forecast model 02035 Instruction Manual Introduction The AcuRite Weather Station with wireless outdoor sensor collects outside weather data and sends it wirelessly to the Display Console via radio frequency This weather forecaster has been designed to be easy to install and use This weather station features a NEW Precision 5 Day Weather Forecasting technology which allows you to select one of seven geographic regions to give you a detailed accurate forecast from your own backyard The easy to read forecast display predicts your cloud cover high and low temperatures and chance of precipitation over the next 5 days by analyzing your weather patterns and changes in great detail The sleek display console houses a liquid crystal display LCD which will calculate and display all the weather data received from the wireless sensor outside The display console features a pressure sensor for measuring barometric pressure a temperature sensor for measuring indoor temperature and a humidity sensor for measuring indoor humidity The Display Console is powered with three AA alkaline batteries not included The outdoor sensor is completely wireless and contains a temperature sensor for measuring indoor temperature and a humidity sensor f
12. or measuring relative humidity The wireless outdoor sensor is powered with two AA alkaline or lithium batteries not included Please read through this manual to learn more about the AcuRite Weather Station Keep this manual for future reference Parts List model 02035 1 Display console 2 Wireless outdoor sensor Display Features OS OY ABCDEFG set mode Intelli Time geographic indicator clock region selection day display Stew tS 6 182 date display Eaj current outdoor today s I temperature forecast an l Outdoor mil wireless sensor aw 7 reception today s D l forecasted 4 wo Cet current outdoor LO and HI LO HI humidity current E a REA barometric Presaune Sinia AFAOF Indoor 224 1 current indoor pressure TD 03 56 nJ J conditions pressure learning mode indicator Sy UED Gel THU Gy FRI Se SAT S forecast initial CY as learning mode A indicator V4 4 4 8 450 S67 60 Git 0D itl ie BUT LO HI LO H LO HI LO HI forecasted forecasted LOW THI temperatures temperatures PRODUCT REGISTRATION To receive product updates and information Go to www AcuRite com gt Register a Product Battery Choice amp Temperature Range Extended periods of cold temperatures below 4 F 20 C can cause alkaline batteries to function improperly This will cause the outdoor wireless sensor to stop transmitting readings Use lithium batteries in these low temperatur
13. ress the 4 or V buttons to remove or add moisture to the forecast Note that the forecast graphics will change accordingly Calibrating the forecast may take some trial and error Note that just like any weather forecast the forecast can never be 100 accurate Note that all calibration changes will be lost if you reset the display unit or remove the batteries 13
14. ressure at any location on the Earth caused by the weight of the column of air above it At sea level atmospheric pressure has an average value of one atmosphere and gradually decreases as altitude increases Also called barometric pressure The weight of the air mass or atmosphere that envelopes Earth exerts pressure on all points of the planet s surface Meteorologists use barometers to measure this atmospheric pressure also called barometric pressure At sea level the atmospheric pressure is approximately 1 kilogram per square centimeter 14 7 pounds per square inch which will cause a column of mercury in a mercury barometer to rise 760 millimeters 30 4 inches Subtle variations in atmospheric pressure greatly affect the weather Low pressure generally brings rain In areas of low air pressure the air is less dense and relatively warm which causes it to rise The expanding and rising air naturally cools and the water vapor in the air condenses forming clouds and the drops that fall as rain In high pressure areas conversely the air is dense and relatively cool which causes it to sink The water vapor in the sinking air does not condense leaving the skies sunny and clear This weather forecaster features a current barometric pressure display as well as a trend arrow icon rising falling or steady These two features can assist you in forecasting changes in the weather TROUBLESHOOTING Problem Possible Solution s Bad W
15. struction materials MADE IN CHINA HECHO EN CHINA Limited One Year Warranty Instructions amp Warranty Enclosed Customer Care 877 221 1252 www Acurite com Patent numbers 5 978 738 6 076 044 6 597 990 US 7 637 141 B2 ACURITE is a registered trademark of the Chaney Instrument Co Lake Geneva WI 53147 WARNING THIS PRODUCT CONTAINS A BUTTON CELL BATTERY IF SWALLOWED IT COULD CAUSE SEVERE INJURY OR DEATH IN JUST 2 HOURS lt SEEK MEDICAL ATTENTION IMMIDIATELY IF INGESTED lt POISON POISON PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS BATTERY SAFETY Clean the battery contacts and also those of the device prior to battery installation Remove batteries from equipment which is not to be used for an extended period of time Follow the polarity diagram in the battery compartment Promptly remove dead batteries from the device Dispose of used batteries properly Only batteries of the same or equivalent type as recommended are to be used DO NOT incinerate used batteries DO NOT dispose of batteries in fire as batteries may explode or leak DO NOT mix old and new batteries or types of batteries alkaline standard DO NOT use rechargeable batteries DO NOT recharge non rechargeable batteries DO NOT short circuit the supply terminals 12 CALIBRATION If you find that the temperature and or humidity is slightly off this
16. undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However There is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help NOTE The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment Such modifications could void the user authority to operate the equipment Patent numbers 9 978 738 6 076 044 6 597 990 US 7 637 141 B2 02035 120511 7 Nan 6 Pia E DESIGNED TO WORK FOR YOU Be Pea 6 18 Forecast Outdo
17. ving Time preferences The clock will automatically set itself and change automatically for Daylight Saving Time WARNING THIS PRODUCT CONTAINS A BUTTON CELL BATTERY IF SWALLOWED IT COULD CAUSE SEVERE INJURY OR DEATH IN JUST 2 HOURS lt SEEK MEDICAL ATTENTION IMMIDIATELY IF INGESTED lt POISON POISON 3 About the 5 Day Weather Forecast This weather station includes AcuRite s NEW precision 5 day forecasting technology By determining your geographic climate region and observing sets of weather related variables like changes in temperature humidity and barometric pressure this AcuRite Weather Station can accurately forecast the weather for your exact location Preprogrammed regional weather patterns combined with data collected by the wireless outdoor temperature and humidity sensor allow for forecasts that include probability of precipitation amount of cloud cover and high low temperatures for up to 5 days 5 Day Forecast Region Selection For the 5 day forecast to function properly you will need to select your general geographic region The 5 Day Forecast feature analyzes outdoor temperature outdoor humidity pressure changes and geographic region information to give you the most accurate forecast breakdown a single station forecaster can provide PRESS THE GEO BUTTON LOCATED ON THE BACK OF THE DISPLAY TO SELECT YOUR GEOGRAPHIC REGION NA Quick Setup Display Console After instal