Home

Cisco Intel Xeon E5-2403 v2

image

Contents

1. 47 Connectivity using the Cisco UCS 2204XP Fabric Extender 50 Connectivity using the Cisco UCS 2104XP Fabric Extender 53 TECHNICAL SPECIFICATIONS 0c eee ee ee ee ts D4 Dimensions and Weight 0 0 cece eee ee we ee tee ee eee eee ee eee ete eee 54 Power Specifications 6 aa o42444 646464552 656000 54545065668 6552 GGG oes os 54 Cisco UCS B22 M3 Blade Server OVERVIEW OVERVIEW The Cisco UCS B22 M3 Blade Server delivers a balanced price performance feature set to address quick deployment of scalable IT infrastructure and Web 2 0 applications The Cisco UCS B22 M3 harnesses the power of the latest latest Intel Xeon E5 2400 v2 and E5 2400 series processor family CPUs with expandability to 384 GB of RAM using 32 GB DIMMs 2 hot plug drives and 2 PCle mezzanine adapter slots for up to 80 Gbps throughput Figure 1 Cisco UCS B22 M3 Blade Server Cisco UCS B22 M3 Blade Server DETAILED VIEWS DETAILED VIEWS Blade Server Front View Figure 2 is a detailed front view of the Cisco UCS B22 M3 Blade Server Figure 2 Blade Server Front View 332661 Asset pull handle a blank asset tag is provided on which you can add your own label or sticker or you can use a marker to write your asset information on the tag Blade ejector handle e Blade health LED Network link status LED Console connector eset button access Beaconing LED and button 1 For informat
2. Adapter 2 Slot Adapter 1 Slot Pile x8 Connectivity using the Cisco UCS 2204XP Fabric Extender The Cisco UCS 2204XP is a second generation Fabric Extender and shares the same form factor as the current UCS 2100 series The 2204XP is backwards compatible with the UCS 5108 Blade serve chassis The option shown in Figure 12 demonstrates how a 1 CPU server is connected to the Cisco UCS 2208XP One port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender 44 Cisco UCS B22 M3 Blade Server SUPPLEMENTAL MATERIAL Figure 12 VIC 1240 to UCS 2204XP Fabric Extender no mezzanine adapter Port Group A Port Group B No Mezzanine Adapter Installed VIC 1240 Adapter Adapter 2 Slot Adaper 1 Slot Connectivity using the Cisco UCS 2104XP Fabric Extender The option shown in Figure 13 demonstrates how a 1 CPU server is connected to the Cisco UCS 2104XP One port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is channeled to 2104XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender Figure 13 VIC 1240 to UCS 2104XP Fabric Extender no mezzanine adapter el el el Port Group A Port Group B No Mezzanine Adapter Installed VIC 1240 Adapter Adapter 2 Slot Adapter 1 Slot PCle x16 Cisco UCS B22 M3 Blade Server 45 SUPPLEMENTAL MATERIAL B22 M3 Config
3. Emulex M73KR E QLogic M73KR Q m Cisco UCS Storage Accelerators 785 GB MLC Fusion ioDrive2 LSI 400 GB SLC WarpDrive The following sections explain the various I O options that are possible with the different Fabric Extenders Cisco UCS 2208XP 2204XP and 2104XP and the VIC 1240 and mezzanine adapters Cisco UCS B22 M3 Blade Server 43 SUPPLEMENTAL MATERIAL B22 M3 Configured with 1 CPU In a B22 M3 configured with 1 CPU the mezzanine card slot adapter 2 slot is not under the control of a CPU in a B22 M3 configured with 2 CPUs CPU 2 controls the adapter 2 slot Therefore in this configuration no adapter is supported in the adapter 2 slot and the VIC 1240 is always required to be installed in the adapter 1 slot Connectivity using the Cisco UCS 2208XP Fabric Extender The Cisco UCS 2208XP is the second generation Fabric Extender and shares the same form factor as the current UCS 2100 series The 2208XP is backwards compatible with the UCS 5108 Blade serve chassis The option shown in Figure 11 demonstrates how a 1 CPU server is connected to the Cisco UCS 2208XP Two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The result is 20 Gbps of bandwidth to each Fabric Extender Figure 11 VIC 1240 to UCS 2208XP Fabric Extender no mezzanine adapter mininin Port Group A Port Group B No Mezzanine Adapter Installed VIC 1240 Adapter
4. To Fabric Interconnects To Fabric Interconnects UCS 5108 Blade Server Chassis oc se J qa P Mezzanine Adapter VIC 1240 Adapter Adapter 2 Slot Adapter 1 Slot Si The server accommodates two types of network I O adapters One is the Cisco VIC 1240 network I O adapter The other is a Cisco Emulex or QLogic I O adapter or Cisco UCS Storage Accelerator mezzanine adapter The VIC 1240 is the only adapter that can be used in the VIC 1240 adapter 1 slot All other types of adapters plug into the mezzanine adapter 2 slot Cisco UCS B22 M3 Blade Server 41 SUPPLEMENTAL MATERIAL The network adapter options are m VIC 1240 adapter This adapter plugs into the VIC 1240 adapter 1 slot and is natively capable of 4x10Gb ports and 256 PCle devices m VIC 1280 Mezzanine adapter This adapter plugs into the mezzanine adapter 2 slot and is capable of 4x10Gb ports in the UCS B22 M3 server depending on the Fabric Extender chosen see Table 8 on page 17 and 256 PCle devices m Emulex or QLogic I O adapter or Cisco UCS Storage Accelerator mezzanine adapter These adapters plug into the mezzanine adapter 2 slot The Cisco UCS Storage Accelerators do not have network connectivity instead they provide independent high speed storage controlled by CPU 2 See Table 7 on page 17 for descriptions NOTE External bandwidth is a function of both the fabric extender and the adapter s installed With two 2204XP fabric e
5. 3yr Support Reqd gt 5yr Support Reqd gt 1yr Support Reqd 3yr Support Reqd SS 5yr Support Reqd SLES SHA 2S 1A SUSE Linux High Availability Ext 1 2 CPU 1yr Support Reqd SLES SHA 2S 3A SUSE Linux High Availability Ext 1 2 CPU 3yr Support Reqd SLES SHA 2S 5A SUSE Linux High Availability Ext 1 2 CPU 5yr Support Reqd SLES HGC 2S 1A SUSE Linux GEO Clustering for HA 1 2 CPU 1yr Support Reqd SLES HGC 2S 3A SUSE Linux GEO Clustering for HA 1 2 CPU 3yr Support Reqd SLES HGC 2S 5A SUSE Linux GEO Clustering for HA 1 2 CPU 5yr Support Reqd SLES SAP 2S 1G 1A SLES for SAP Applications 1 2 CPU 1 Phys 1yr Support Reqd SLES SAP 2S 1G 3A SLES for SAP Applications 1 2 CPU 1 Phys 3yr Support Reqd SLES SAP 2S 1G 5A SLES for SAP Applications 1 2 CPU 1 Phys 5yr Support Reqd SLES SAP 2S UG 1A SLES for SAP Applications 1 2 CPU Unl Vrt 1yr Support Reqd SLES SAP 2S UG 3A SLES for SAP Applications 1 2 CPU Unl Vrt 3yr Support Reqd SLES SAP 2S UG 5A SLES for SAP Applications 1 2 CPU Unl Vrt 5yr Support Reqd Cisco UCS B22 M3 Blade Server 23 CONFIGURING the SERVER Table 14 OSs and Value Added Software for 2 CPU servers continued Product ID PID PID Description Red Hat Enterprise Linux RHEL 2S 1G 1A RHEL 2S 1G 3A RHEL HA 2S 1A RHEL HA 2S 3A RHEL RS 2S 1A RHEL RS 2S 3A RHEL SFS 2S 1A RHEL SFS 2S 3A RHEL 2 Socket 1 Guest 1Yr Svcs Required RHEL 2 Socket 1 Guest 3Yr Svcs Required RHEL Op
6. 8FET 2204XP None 2204XP VIC 1240 2204 XP VIC 1240 2204XP VIC 1240 2204XP VIC 1240 2104XP PID N20 16584 2104XP VIC 1240 2104XP VIC 1240 Notes Emulex or QLogic I O adapter None Cisco UCS Storage Accelerator Emulex or QLogic I O adapter VIC 1280 None Cisco UCS Storage Accelerator Ports 2 x 10 Gb 2 x 10 Gb 2 x 10 Gb 4x 10Gb 4x 10Gb 2 x 10 Gb 2 x 10 Gb Reference Figure 19 on page 49 Figure 20 on page 50 Figure 21 on page 50 Figure 22 on page 51 Figure 23 on page 51 Figure 24 on page 52 Figure 25 on page 52 1 In the server BIOS and on the motherboard Adapter 1 and Adapter 2 are labeled as mLOM and Mezz 1 respectively 2 Specifically the UCSB MEZ QLG 03 QLogic or UCSB MEZ ELX 03 Emulex adapter Also see Network Connectivity on page 41 for more information To help ensure that your operating system is compatible with the adapters you have selected please check the Hardware Compatibility List at this URL http www cisco com en US products ps10477 prod_technical_ reference _list html Caveats m If a VIC 1240 adapter is not installed 2 CPU configuration only you must choose a Cisco Emulex or QLogic I O adapter to be installed in adapter 2 slot see also Network Connectivity on page 41 m The mezzanine adapters are not supported for 1 CPU configurations You must have two CPUs installed before you can install and use mezzanine adapters m The 1 CPU se
7. Network Adapters CNAs consolidate Ethernet and Storage FC traffic on the Unified Fabric by supporting FCoE m Cisco UCS Storage Accelerators These Storage Accelerator adapters are designed specifically for the Cisco UCS B series M3 blades servers and integrate seamlessly to allow improvement in performance and relief of I O bottlenecks Q NOTE There are two slots on the server Adapter slot 2 accommodates Em ulex or QLogic I O adapters or Cisco UCS Storage Accelerators and adapter slot 1 is a dedicated slot for the VIC 1240 adapter only Table 7 shows which adapters plug into each of the two slots Only the VIC 1240 adapter plugs into the VIC 1240 adapter 1 slot All other adapters plug into the adapter 2 slot NOTE You must have a B22 M3 configured with 2 CPUs to support adapters that plug O into the adapter 2 connector The VIC 1240 adapter is supported on both 1 and Ss 2 CPU configured systems Cisco UCS B22 M3 Blade Server CONFIGURING the SERVER Choose a Mezzanine Adapter The supported mezzanine adapters in the UCS B22 M3 are listed in Table 7 Table 7 Supported Mezzanine Adapters Product ID PID PID Description Connector Virtual Interface Cards VICs UCSB MLOM 40G 01 Cisco UCS VIC 1240 modular LOM for M3 blade servers Plugs into Adapter 1 adapter slot 1 only It is the only adapter that can be plugged into the adapter 1 connector UCS VIC M82 8P Cisco UCS VIC 1280 dual 40 Gb capable Virtual I
8. SATA support m RAID 0 and 1 cache However servers that implement two HDDs and RAID controllers with cache lack the ability to match the performance of RAID ed SSDs without cache as implemented in this server NOTE The integrated RAID controller does not implement a write oC Up to two optional front accessible hot swappable 2 5 inch small form factor SFF SAS or SATA solid state disks SSDs or hard disk drives HDDs An internal USB 2 0 port is also supported A 4 GB USB 2 0 device is available from Cisco Cisco UCS B22 M3 Blade Server BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 Capabilities and Features continued Capability Feature Description Video Interfaces Power subsystem Fans Integrated management processor Cisco UCS Diagnostics for Cisco UCS B Series Blade Servers The Emulex Pilot 3 Integrated Baseboard Management Controller provides video m Matrox G200e video controller m Integrated 2D graphics core with hardware acceleration m Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at 60 Hz m 24 bit color depth for all resolutions less than 1600x1200 m 8 MB video memory m Front panel e One console connector see ORDER OPTIONAL KVM LOCAL I O CABLE on page 32 Integrated in the Cisco UCS 5100 series blade server chassis Integrated in the Cisco UCS 5100 series blade server chassis The built in Cisco Integrated Management Controlle
9. Similarly a blade server blanking panel N20 CBLKB1 must be installed if you remove a half width blade server such as a UCS B22 M3 server from a blade server chassis These panels are required to maintain system temperatures at safe operating levels and to keep dust away from system components Adding an Additional CPU with CPU heat sink All Cisco UCS two CPU socket capable servers can be upgraded from having one to having two CPUs configured You will need to order and install a heat sink when adding any additional CPU to a server Instructions for installing the new CPU and heat sink can be found at the following link http www cisco com en US docs unified_computing ucs hw chassis install b22 html wp1010281 Motherboard Lithium Battery You can order a replacement motherboard battery Installation instructions are found at this link 38 Cisco UCS B22 M3 Blade Server SUPPLEMENTAL MATERIAL http www cisco com en US docs unified_computing ucs hw chassis install b22 html wp1034829 CPU Removal and Installation pick n place Tool Set The Pick n Place tool set includes two tools m Pick and pull cap tool used to pull off the plastic protective cap covering an empty CPU socket and to remove or lift a CPU processor without touching it m Pick and place tool used to install a CPU in its socket without damage Must be used each time a CPU is installed in a UCS M3 server Instructions for using this tool set are
10. Storage Accelerator adapter el tl be Port Group A Port Group B Cisco UCS Storage Accelerator Adapter only Installed VIC 1240 Adapter Adaper 2 Slot Adapter 1 Slot In Figure 25 one port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is channeled to 2104XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender There is no adapter located in the mezzanine connector Figure 25 VIC 1240 to UCS 2104XP Fabric Extender no mezzanine adapter installed Port Group A Port Group B No Mezzanine Adapter Installed VIC 1240 Adapter E Mezzanine Slot E O MIC 1240 Slot 52 Cisco UCS B22 M3 Blade Server TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 26 UCS B22 M3 Dimensions and Weight Parameter Value Height 1 95 in 50 mm Width 8 00 in 203 mm Depth 24 4 in 620 mm Weight m Base server weight no HDDs no CPUs no VIC 1240 adapter no mezzanine adapter no memory 9 62 lbs 4 36 kg Minimally configured server 1 HDD 1 CPU a VIC 1240 adapter but no mezzanine adapters 1 DIMM module 12 50 lbs 5 67 kg m Fully configured server 2 HDDs 2 CPUs VIC 1240 and mezzanine adapters both populated all memory 14 98 lbs 6 79 kg Power Specifications For configuration specific power specifications use the Cisco UCS Power Calculator at http ucspowercalc cisco com Cisco UCS B22 M3 Blade Server 53 TECHNICAL SP
11. ae ee Port Group A Port Group B No Mezzanine Adapter Installed VIC 1240 Adapter Adapter 2 Slot Adapter 1 Slot L PCle x8 In Figure 16 two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The result is 20 Gbps of bandwidth to each Fabric Extender The Cisco UCS Storage Accelerator adapter in the adapter 2 slot has no network connectivity Figure 16 Option 3 VIC 1240 to UCS 2208XP Fabric Extender with Cisco UCS Storage Accelerator adapter at a a m a 10G KR 10G KR i 10G KR l Fort Group B Cisco UCS Storage Accelerator Adapter Installed VIC 1240 Adapter Adapter 2 Slot Adapter 1 Slot PCle x8 Cisco UCS B22 M3 Blade Server 47 SUPPLEMENTAL MATERIAL In Figure 17 two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The Emulex or QLogic I O adapter installed in the adapter 2 slot also channels one port to each of the Fabric Extenders The result is 30 Gbps of bandwidth to each Fabric Extender Figure 17 Option 4 VIC 1240 and Emulex or QLogic I O Adapter to UCS 2208XP Fabric Extender Port Group B Port Group A Emulex or QLogic 1 O Adapter VIC 1240 Adapter Adapter 2 Slot Adapter 1 Slot PCle x16 PCle x8 In Figure 18 two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are
12. channeled to 2208XP Fabric Extender B The VIC 1280 installed in the adapter 2 slot also channels two ports to each of the Fabric Extenders The result is 40 Gbps of bandwidth to each Fabric Extender Figure 18 Option 5 VIC 1240 and VIC 1280 to UCS 2208XP Fabric Extender DopE Port Group A Port Group A Port Group B VIC 1280 Adapter VIC 1240 Adapter Adapter 2 Slot Adapter 1 Slot 48 Cisco UCS B22 M3 Blade Server SUPPLEMENTAL MATERIAL Connectivity using the Cisco UCS 2204XP Fabric Extender The Cisco UCS 2208XP is a second generation Fabric Extender and shares the same form factor as the current UCS 2100 series The 2204XP is backwards compatible with the UCS 5108 Blade serve chassis The options shown in Figure 19 through Figure 23 demonstrate how the server uses these options Emulex or QLogic I O adapter to 2204XP VIC 1240 to 2204XP VIC 1240 and Cisco UCS Storage Accelerator adapter to 2204XP VIC 1240 and Emulex or QLogic I O adapter to 2204XP m VIC 1240 and VIC 1280 to 2204XP In Figure 19 there is no VIC 1240 adapter installed In this case a network adapter must be installed in the adapter 2 slot Ports A and B of the mezzanine adapter connect to the Fabric Extenders providing 10 Gbps per port Figure 19 Option 1 Emulex or QLogic I O Adapter to UCS 2204XP Fabric Extender no VIC 1240 adapter Let bet ob 10G KR Emulex or QLogic VO Adapter No VIC 1240 Adapter Installe
13. for 1 CPU 2 Yr Support Rqd VMware vSphere 5 Enterprise Plus for 1 Processor 3 Year Support Rqd VMware vSphere 5 Enterprise Plus for 1 Processor 4 Year Support Rqd VMware vCenter 5 Server Standard 1 yr support required VMware vCenter 5 Server Standard 2 yr support required VMware vCenter 5 Server Standard 3 yr support required VMware vCenter 5 Server Standard 4 yr support required VMware vCenter 5 Server Standard 5 yr support required Q NOTE For additional information see OS hypervisor support matrix at the following link http www cisco com en US products ps10477 prod_technical_reference_list h tml Cisco UCS B22 M3 Blade Server 25 CONFIGURING the SERVER 26 STEP 10 CHOOSE OPERATING SYSTEM MEDIA KIT Choose the optional operating system media listed in Table 15 Table 15 OS Media Product ID PID RHEL 6 SLES 11 MSWS 12 ST2S RM MSWS 12 DC2S RM MSWS 12R2 ST2S RM MSWS 12R2 DC2S RM PID Description RHEL 6 Recovery Media Only Multilingual SLES 11 media only multilingual Windows Server 2012 Standard 2 CPU 2 VMs Recovery Media Windows Server 2012 Datacenter 2 CPU Unlimited VM Rec Media Windows Server 2012 R2 Standard 2 CPU 2 VMs Recovery Media Windows Server 2012 R2 Datacen 2 CPU Unlimited VM Rec Media Cisco UCS B22 M3 Blade Server CONFIGURING the SERVER STEP 11 CHOOSE SERVICE and SUPPORT LEVEL A variety of service options are available as described in this section Unifie
14. found at the following link http www cisco com en US docs unified_computing ucs hw chassis install b22 html wp1010281 Q NOTE When you purchase a spare CPU the Pick n Place Toolkit is included Thermal Grease with syringe applicator for CPU to Heatsink Seal Thermal grease must be applied to the top of the CPU where it comes in contact with the heat sink Instructions for applying thermal grease are found at http www cisco com en US docs unified_computing ucs hw chassis install b22 html wp1010281 CAUTION Use only the thermal grease specified for this server AA UCS CPU GREASE Thermal grease for other systems may have different thermal conductivity properties and may cause overheating if used in the B22 M3 server DO NOT use thermal grease available for purchase at any commercial electronics store If these instructions are not followed the CPU may overheat and be destroyed NOTE When you purchase a spare CPU the thermal grease with syringe applicator is included Q Air Baffle Replacement Kit Air baffles are designed to direct airflow through the server to maintain server temperature at a safe operating level The UCS B22 M3 server comes shipped with two identical air baffles covering the DIMM socket areas of the server These baffles must always remain installed during server operation The Air Baffle Replacement Kit includes the two identical air baffles needed for one UCS B22 M3 server For
15. 0 and Emulex or QLogic I O Adapter to UCS 2204XP Fabric Extender Dhl bel bel 2 2 8 Port Group A Port Group B Emulex or QLogic I O Adapter VIC 1240 Adapter Adapter 1 Slot E PCle x8 Adapter 2 Slot E PCle x16 In Figure 23 one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The VIC 1280 installed in the adapter 2 slot also channels one port to each of the Fabric Extenders The result is 20 Gbps of bandwidth to each Fabric Extender Figure 23 Option 5 VIC 1240 and VIC 1280 to UCS 2204XP Fabric Extender Port Group A Port Group A Port Group B VIC 1240 Adapter VIC 1280 Adapter Adapter Slot 2 Adapter Slot 1 _ PCle x8 Cisco UCS B22 M3 Blade Server 51 SUPPLEMENTAL MATERIAL Connectivity using the Cisco UCS 2104XP Fabric Extender The options shown in Figure 24 and Figure 25 demonstrate how the UCS B22 M3 blade serves connects to a UCS 2104XP Fabric Extender In Figure 24 one port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is channeled to 2104XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender The Cisco UCS Storage Accelerator adapter located in the mezzanine connector acts as an independent device controlled by CPU 2 and has no network connectivity Figure 24 VIC 1240 to UCS 2104XP Fabric Extender with Cisco UCS
16. 2800 2R x4 1 35v 35nm 1 35 1 5V 2 4GB DDR3 1600 MHz RDIMM PC3 12800 1R x4 1 35v 35nm 1 35 1 5V 1 Memory Mirroring Option NO1 MMIRROR 12 Memory mirroring option Cisco UCS B22 M3 Blade Server CONFIGURING the SERVER Supported Configurations 1 Without memory mirroring m Select from 1 to 6 DIMMs per CPU note that there are 6 DIMM slots per CPU 2 With memory mirroring m Select 2 or 4 DIMMs per CPU The DIMMs must be identical across channels for the same banks The DIMMs will be placed by the factory as shown in Table 5 Table 5 DIMM Placement With Memory Mirroring Number of DIMM Placement in Channels with memory mirroring implemented DIMMs per Note that Channels B and F are not used for memory mirroring CPU CPU 1 CPU 2 2 1 DIMM in Channel C CO 1 DIMM in Channel G GO 1 DIMM in Channel D DO 1 DIMM in Channel H HO 4 2 DIMMs in Channel C CO C1 2 DIMMs in Channel G GO G1 2 DIMMs in Channel D DO D1 2 DIMMs in Channel H HO H1 m Select the memory mirroring option NO1 MMIRROR as shown in Table 4 on page 12 Q NOTE System performance is optimized when the DIMM type and quantity are equal for both CPUs and when all channels are filled equally across the CPUs in the server Caveats m For 2 CPU configurations DIMMs must be even across the server 2 4 6 up to 12 For example you can select four 8 GB DIMMs and six 16 GB DIMMS m Memory mirroring reduces the amount of availa
17. 500 GB 6 Gb SATA 7 2K RPM SFF HDD SATA 500 GB UCS HDD300GI2F105 300 GB 6 Gb SAS 15K RPM SFF HDD SAS 300 GB A03 D300GA2 300 GB 6 Gb SAS 10K RPM SFF HDD SAS 300 GB SSDs UCS SD400GOKA2 G 400GB SATA 2 5 Enterprise Value SSD SATA 400 GB UCS SD120GOKS2 EV 120 GB SATA 2 5 inch Enterprise Value 6G SSD SATA 120 GB UCS SD100GOKA2 G 100GB SATA 2 5 Enterprise Value SSD SATA 100 GB NOTE The integrated LSI 2002 MegaRAID controller supports hard disk drives HDDs O or solid state drives SSDs Write cache is not implemented SSDs are recommended for applications requiring high speed local storage which is an order of magnitude faster than HDDs 14 Cisco UCS B22 M3 Blade Server CONFIGURING the SERVER Supported Configurations 1 1 Drive System m Select one of the drives listed in Table 6 1 2 Drive System m Select two identical drives from Table 6 There is no support for mixing of drive types or capacities Caveats m If you select two drives they must be identical in type and capacity Cisco UCS B22 M3 Blade Server 15 CONFIGURING the SERVER 16 STEP 5 CHOOSE ADAPTERS The adapter offerings are m Cisco Adapters Virtual Interface Cards VICs Cisco developed Virtual Interface Cards VICs to provide flexibility to create multiple NIC and HBA devices The VICs also support adapter Fabric Extender and Virtual Machine Fabric Extender technologies m Converged Network Adapters CNAs Emulex and QLogic Converged
18. 52470B E5 2407 v2 2 4 95 25 10 6 4 GT s 1600 UCS CPU E52450B E5 2450 v2 2 5 95 20 8 7 2 GT s 1600 UCS CPU E52440B E5 2440 v2 1 90 95 20 8 7 2 GT s 1600 UCS CPU E52430LB E5 2430L v2 2 40 60 15 6 7 2 GT s 1600 UCS CPU E52420B E5 2420 v2 2 20 80 15 6 7 2 GT s 1600 UCS CPU E52407B E5 2407 v2 2 40 80 10 4 6 4 GT s 1333 UCS CPU E52403B E5 2403 v2 1 80 80 10 4 6 4 GT s 1333 Intel Xeon E5 2400 UCS CPU E5 2470 E5 2470 2 30 95 20 8 8 GT s 1600 UCS CPU E5 2450 E5 2450 2 10 95 20 8 8 GT s 1600 UCS CPU E5 2440 E5 2440 2 40 95 15 6 7 2 GT s 1333 UCS CPU E5 2430L E5 2430L 2 00 60 15 6 6 4 GT s 1333 UCS CPU E5 2420 E5 2420 1 90 95 15 6 7 2 GT s 1333 UCS CPU E5 2403 E5 2403 1 80 80 10 4 6 4 GT s 1066 Notes 1 If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock For example Selecting lower speed DIMMs If you use an E4 2470 CPU which can support up to 1600 MHz DIMMs with 1333 MHz DIMMs the DIMMs will be clocked at the lower speed of 1333 MHz Selecting higher speed DIMMs If you use 1600 MHz DIMMs with an E5 2420 CPU which can support up to 1333 MHz DIMMs the DIMMS will be clocked at the lower speed of 1333 MHz Cisco UCS B22 M3 Blade Server 9 CONFIGURING the SERVER Supported Configurations 1 1 CPU Configuration Choose one CPU from any one of the rows of Table 3 on page 9 2 Two CPU Configuration Cavea
19. B 4 GB 16 GB 8 GB 16 GB 32 GB 32 GB 1 CPU Memory Size 24 48 96 24 48 96 36 60 GB 72 GB 192 GB 2 CPU Memory Size 48 96 192 48 96 192 72 120 GB 144 GB 384 GB DIMM Speed 1600 MHz 1600 MHz 1600 MHz 1600 MHz 1600 MHz 1600 MHz 1600 MHz 1600 MHz 1600 MHz 160 MHz If 4 GB DIMMs are mixed with 8 GB or 16 GB DIMMs the DIMM slots are populated as shown in Table 24 Table 24 4 GB DIMMs Mixed with 8 GB or 16 GB DIMMs Total Memory Number CPU 1 DIMM Size GB Populated CPU 2 DIMM Size GB Populated GB of CPUs FO F1 GO G1 HO H1 12 20 4 8 16 none none none 24 40 4 4 8 16 8 16 none 20 28 4 4 4 4 none 16 4 4 4 4 none 32 48 4 4 4 4 none 28 36 4 4 4 4 none 36 Cisco UCS B22 M3 Blade Server SUPPLEMENTAL MATERIAL Table 24 4 GB DIMMs Mixed with 8 GB or 16 GB DIMMs continued ieee Number CPU 1 DIMM Size GB Populated CPU 2 DIMM Size GB Populated GB of CPUs BO B1 co C1 DO D1 FO F1 G0 G1 HO H1 24 40 2 4 8 16 none none none none 4 8 16 none none none none 48 80 4 4 8 16 8 16 none none 4 4 8 16 8 16 none none 40 56 4 4 4 8 16 none none 4 4 4 8 16 none none 32 4 4 4 4 none none 4 4 4 4 none none 64 96 4 4 4 4 8 16 8 16 4 4 4 4 8 16 8 16 56 72 4 4 4 4 4 8 16 4 4 4 4 4 8 16 Cisco UCS B22 M3 Blade Server 37 SUPPLEMENTAL MATERIAL Upgrade and Servicing Related Parts This section lists the upgrade and servicing relat
20. ECIFICATIONS etfect t CISCO Americas Headquarters Asia Pacific Headquarters Europe Headquarters Cisco Systems Inc Cisco Systems USA Pte Ltd Cisco Systems International BV Amsterdam San Jose CA Singapore The Netherlands Cisco has more than 200 offices worldwide Addresses phone numbers and fax numbers are listed on the Cisco Website at www cisco com go offices Cisco and the Cisco Logo are trademarks of Cisco Systems Inc and or its affiliates in the U S and other countries A listing of Cisco s trademarks can be found at www cisco com go trademarks Third party trademarks mentioned are the property of their respective owners The use of the word partner does not imply a partnership relationship between Cisco and any other company 1005R 54 Cisco UCS B22 M3 Blade Server
21. P PSS 8X5X4 UCS B22 M3 Server CON PSJ3 B22M3 PSJ3 No UCS SUPP PSS 24X7X4 UCS B22 M3 Server CON PSJ4 B22M3 PSJ4 No UCS SUPP PSS 24X7X2 UCS B22 M3 Server Partner Support Service for UCS Hardware Only provides customers with replacement parts in as little as two hours See Table 19 Table 19 Partner Support Service for UCS Hardware Only Product ID PID eee ie Description CON PSW2 B22M3 PSW2 No UCS W PL PSS 8X5X4 UCS B22 M3 Server CON PSW3 B22M3 PSW3 No UCS W PL PSS 24X7X4 UCS B22 M3 Server CON PSW4 B22M3 PSW4 No UCS W PL PSS 24X7X2 UCS B22 M3 Server Unified Computing Combined Support Service Combined Services makes it easier to purchase and manage required services under one contract SMARTnet services for UCS help increase the availability of your vital data center infrastructure and realize the most value from your unified computing investment The more benefits you realize from the Cisco Unified Computing System Cisco UCS the more important the technology becomes to your business These services allow you to Cisco UCS B22 M3 Blade Server Optimize the uptime performance and efficiency of your UCS Protect your vital business applications by rapidly identifying and addressing issues Strengthen in house expertise through knowledge transfer and mentoring Improve operational efficiency by allowing UCS experts to augment your internal staff resources Enhance business agility by diagnosing potential issues before they affect
22. ble memory by 50 quantity of DIMMs must be even for mirroring m By default all DIMMs run at 1 35 V which yields 1333 MHz memory speeds To run the memory DIMMS at 1600 MHz you need to go into the BIOS or set the policy with UCSM service profile to run in Performance Mode This forces the DIMMs to operate at 1 5 V and yields 1600 MHz speeds provided The DIMMs are 1600 MHz devices The CPUs chosen support 1600 MHz operation For more information regarding memory see DIMM and CPU Layout on page 34 and DIMM Population on page 36 Cisco UCS B22 M3 Blade Server 13 CONFIGURING the SERVER STEP 4 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES OPTIONAL The UCS B22 M3 can be ordered with or without drives The standard disk drive features are m 2 5 inch small form factor m Hot pluggable sled mounted NOTE The UCS B22 M3 blade server meets the external storage target and switch O certifications as described in the following link NS http www cisco com en US docs switches datacenter mds9000 interoperabilit y matrix Matrix8 html wp323852 Choose Drives The supported drives in the UCS B22 M3 are listed in Table 6 Table 6 Supported Hot Pluggable Sled Mounted HDDs and SSDs Product ID PID PID Description Capacity HDDs A03 D1TBSATA 1 TB 6 Gb SATA 7 2K RPM SFF HDD SATA 1 TB UCS HDD900GI2F106 900 GB 6Gb SAS 10K RPM SFF HDD SAS 900 GB A03 D600GA2 600 GB 6 Gb SAS 10K RPM SFF HDD SAS 600 GB A03 D500GC3
23. d Adapter Slot 2 Adapter SLot 1 cle x16 Cisco UCS B22 M3 Blade Server 49 SUPPLEMENTAL MATERIAL In Figure 20 there is no mezzanine adapter One port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender Figure 20 Option 2 VIC 1240 to UCS 2204XP Fabric Extender no mezzanine adapter 8 Port Group A Port Group B No Mezzanine Adapter Installed VIC 1240 Adapter Adapter 2 Slot Adapter 1 Slot In Figure 21 one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender The Cisco UCS Storage Accelerator adapter has no network connectivity Figure 21 Option 3 VIC 1240 to UCS 2204XP Fabric Extender with Cisco UCS Storage Accelerator Ch et Ik 2 8 Port Group A Port Group B Cisco UCS Storage Accelerator Adapter Installed VIC 1240 Adapter Adapter 2 Slot Adapter 1 Slot E 50 Cisco UCS B22 M3 Blade Server SUPPLEMENTAL MATERIAL In Figure 22 one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The Emulex or QLogic I O adapter installed in the adapter 2 slot also channels one port to each of the Fabric Extenders The result is 20 Gbps of bandwidth to each Fabric Extender Figure 22 Option 4 VIC 124
24. d Computing Warranty No Contract If you have noncritical implementations and choose to have no service contract the following coverage is supplied m Three year parts coverage Next business day NBD onsite parts replacement eight hours a day five days a week 90 day software warranty on media Ongoing downloads of BIOS drivers and firmware updates UCSM updates for systems with Unified Computing System Manager These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications release notes and industry standards SMARTnet for UCS For support of the entire Unified Computing System Cisco offers the Cisco SMARTnet for UCS Service This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment Access to Cisco Technical Assistance Center TAC is provided around the clock from anywhere in the world For UCS blade servers there is Smart Call Home which provides proactive embedded diagnostics and real time alerts For systems that include Unified Computing System Manager the support service includes downloads of UCSM upgrades The Cisco SMARTnet for UCS Service includes flexible hardware replacement options including replacement in as little as two hours There is also access to Cisco s extensive online technical resources to help maintain optimal efficiency and uptime of the unif
25. e 22 STEP 9 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE page 23 STEP 10 CHOOSE OPERATING SYSTEM MEDIA KIT page 26 STEP 11 CHOOSE SERVICE and SUPPORT LEVEL page 27 Cisco UCS B22 M3 Blade Server 7 CONFIGURING the SERVER STEP 1 VERIFY SERVER SKU Verify the product ID PID of the server as shown in Table 2 Table 2 PID of the Base UCS B22 M3 Blade Server Product ID PID Description UCSB B22 M3 UCS B22 M3 Blade Server without CPU memory HDD VIC 1240 adapter or mezzanine adapters The base Cisco UCS B22 M3 blade server does not include the following components They are to be selected during product ordering m CPU s Memory Disk drives VIC 1240 adapter Emulex or QLogic I O adapters Cisco UCS Storage Accelerators O NOTE Use the steps on the following pages to order the UCS B22 M3 Ne server with the configurable components that you want configured 8 Cisco UCS B22 M3 Blade Server CONFIGURING the SERVER STEP 2 CHOOSE CPU S The standard CPU features are m Intel Xeon processor E5 2400 v2 or E5 2400 series processor family CPUs m Intel C600 series chipset m Cache sizes of up to 25 MB Select CPUs The supported Intel Xeon E5 2400 v2 and E5 2400 series family CPUs on the UCS B22 M3 are listed in Table 3 Table 3 Supported Intel CPUs E5 2400 v2 and E5 2400 Series Processor Family CPUs Product ID PID umber Freq iW size me Cores QPI ea MHz Intel Xeon E5 2400 v2 UCS CPU E
26. e eas 34 DIMM and CPU Layout et te et ee eee eee 35 DIMM PODULALION 2ace0e5686e 4 5 ehaw oda eee eee been oS aa Ae e eae eae 37 Recommended DIMM Populations 0 2 eee eee eee ee ee eee eens 37 Upgrade and Servicing Related Parts 0 cece ee ee tee eee ee eee 39 Drive and Blade Server Blanking Panels 2 cee eee eee eee eee eae 39 Adding an Additional CPU with CPU heat sink 2 2 00 eee ee eee eee 39 Motherboard Lithium Battery 0 eee ee ee eee ee ee eee 39 CPU Removal and Installation pick n place Tool Set 2008 40 Thermal Grease with syringe applicator for CPU to Heatsink Seal 40 Air Baffle Replacement Kit 0 cc eee wee wee eee wee eee eee teens 40 CPU Heat Sink Cleaning Kit 2 tw te et ee tee et eee 41 Network Connectivity 2 5 6 fe 2 eb kee See he ee eee Hee eee Eee eee ees 42 VIC 1240 Adapter a6 oo eyo as oh eee eae OOS 8 SOS EERE Oe oe eee oe ee 43 Mezzanine Adapters 0 ccc cw eee eee ee eee ee ee ee eee te ee tees 44 B22 M3 Configured with 1 CPU 1 et te tee tee 45 Connectivity using the Cisco UCS 2208XP Fabric Extender 45 Connectivity using the Cisco UCS 2204XP Fabric Extender 45 Connectivity using the Cisco UCS 2104XP Fabric Extender 46 B22 M3 Configured with 2 CPUS ce ee te ee te eee 47 Connectivity using the Cisco UCS 2208XP Fabric Extender
27. ed parts you may need during the life of your server Some of these parts are configured with every server or with every UCS 5108 blade server chassis and some may be ordered when needed or may be ordered and kept on hand as spares for future use See Table 25 Table 25 Upgrade and Servicing related Parts for UCS B22 M3 Server Spare Product ID PID Description N20 BBLKD 2 5 inch HDD Blanking Panel N20 CBLKB1 Blade slot blanking panel for UCS 5108 single slot N20 BHTS1 CPU heat sink for UCS B22 M3 and B200 M1 M2 Blade Servers UCS CPU LPCVR EN CPU load plate dust cover for unpopulated CPU sockets UCSB BAFF B22 M3 Air Baffle Replacement Kit for B22 M3 Server N20 MBLIBAT T Replacement Lithium Battery for Server Motherboard CR2032 N20 BKVM KVM local IO cable for UCS servers console port UCS CPU EP PNP Pick n place CPU tool set for Intel E5 EP Socket R 3 UCS CPU GREASE CPU thermal grease syringe needed for heat sink seal UCSX HSCK UCS Processor Heat Sink Cleaning Kit when replacing a CPU Notes 1 This part is included configured with your UCS server in some cases as determined by the configuration of your server 2 This part is included configured with the UCS 5108 blade server chassis 3 This part is included with the purchase of an optional or spare CPU processor kit Drive and Blade Server Blanking Panels A drive blanking panel N20 BBLKD must be installed if you remove a disk drive from a UCS server
28. el C CPU 2 n Channel D Channel H 12 DIMM sockets 3 memory channels per CPU up to 2 DIMMs per channel Cisco UCS B22 M3 Blade Server 11 CONFIGURING the SERVER Choose DIMMs and Memory Mirroring Select the memory configuration and whether or not you want the memory mirroring option The supported memory DIMMs and the mirroring option are listed in Table 4 Q NOTE When memory mirroring is enabled the memory subsystem simultaneously writes identical data to two adjacent channels If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error the system automatically retrieves the data from the other channel A transient or soft error in one channel does not affect the mirrored data and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM Memory mirroring reduces the amount of memory available to the operating system by 50 because only one of the two populated channels provides data The supported memory DIMMs in the UCS B22 M3 are listed in Table 4 Table 4 Supported DDR3 DIMMs and Memory Mirroring Option Product ID PID DIMM Options UCS ML 1X324RY A UCS MR 1X162RY A UCS MR 1X082RY A UCS MR 1X041RY A er Ranks PID Description Voltage DIMM 32GB DDR3 1600 MHz LRDIMM PC3 12800 4R x4 1 35v 35nm 1 35 4 16GB DDR3 1600 MHz RDIMM PC3 12800 2R x4 1 35v 35nm 1 35 1 5V 2 8GB DDR3 1600 MHz RDIMM PC3 1
29. er CONFIGURING the SERVER STEP 9 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE Several operating systems and value added software programs are available Select as desired from Table 14 Table 14 OSs and Value Added Software for 2 CPU servers PID Description Product ID PID CISCO MC isco ONE Foundation Perpetual U isco ON oundation Subsr Intercloud Fabric For business isco ONE Enterprise Cloud Perpetual U isco One Data Center Compute Opt Out Option Microsoft Windows Server MSWS 12 ST2S Windows Server 2012 Standard 2 CPU 2 VMs MSWS 12 DC2S Windows Server 2012 Datacenter 2 CPU Unlimited VMs MSWS 12 ST2S NS Windows Server 2012 Standard 2 CPU 2 VMs No Cisco SVC MSWS 12 DC2S NS Windows Server 2012 Datacenter 2 CPU Unlim VM No Cisco SVC MSWS 12R2 ST2S Windows Server 2012 R2 Standard 2 CPU 2 VMs MSWS 12R2 DC2S Windows Server 2012 R2 Datacenter 2 CPU Unlimited VMs MSWS 12R2 ST2S NS Windows Server 2012 R2 Standard 2 CPU 2 VMs No Cisco SVC MSWS 12R2 DC2S NS Windows Server 2012 R2 Datacen 2 CPU Unlim VM No Cisco Svc SUSE SLES SVR 2S 1G 1A SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys SLES SVR 2S 1G 3A SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys SLES SVR 2S 1G 5A SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys SLES SVR 2S UG 1A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt SLES SVR 2S UG 3A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt SLES SVR 2S UG 5A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt gt 1yr Support Reqd gt
30. ide in and out The Cisco USB device clearance is 0 950 inches 24 1 mm which is a sufficient amount of clearance Cisco UCS B22 M3 Blade Server 33 SUPPLEMENTAL MATERIAL DIMM and CPU Layout Memory is organized as shown in Figure 7 Figure 7 UCS B22 M3 Memory Organization oS 9 Oo co faa co oo CO I D TI mi Channel B Channel F Channel C Channel G i Channel D Channel H 12 DIMM sockets 3 memory channels per CPU up to 2 DIMMs per channel Each CPU controls three memory channels as follows m CPU1 Channels B C and D Bank 0 BO CO and DO blue DIMM slots Bank 1 B1 C1 and D1 black DIMM slots m CPU2 Channels F G and H Bank 0 FO GO and HO blue DIMM slots Bank 1 F G1 and H1 black DIMM slots The DIMM and CPU physical layout is shown in Figure 8 The 6 DIMM slots at the left are controlled by CPU 1 and the 6 DIMM slots on the right are controlled by CPU 2 34 Cisco UCS B22 M3 Blade Server SUPPLEMENTAL MATERIAL Figure 8 DIMM and CPU Layout Em Channels B D for CPU 1 2o Channels F H for CPU 2 Cisco UCS B22 M3 Blade Server 35 SUPPLEMENTAL MATERIAL DIMM Population Recommended DIMM Populations Table 23 shows the recommended DIMM slot populations Table 23 Recommended DIMM Population DIMMs per Channel DIMMs in Each Channel 8 GB 16 GB 32 GB 4 GB 4 GB 8 GB 8 GB 16 GB 16 GB 4 GB 8 G
31. ied computing environment You can choose a desired service listed in Table 16 Table 16 Cisco SMARTnet for UCS Service Product ID PID On Site Description CON PREM B22M3 Yes ONSITE 24X7X2 UCS B22 M3 Server CON OSP B22M3 Yes ONSITE 24X7X4 UCS B22 M3 Server CON OSE B22M3 Yes ONSITE 8X5X4 UCS B22 M3 Server CON OS B22M3 Yes ONSITE 8X5XNBD UCS B22 M3 Server CON S2P B22M3 No SMARTNET 24X7X2 UCS B22 M3 Server CON SNTP B22M3 No SMARTNET 24X7X4 UCS B22 M3 Server CON SNTE B22M3 No SMARTNET 8X5X4 UCS B22 M3 Server CON SNT B22M3 No SMARTNET 8X5XNBD UCS B22 M3 Server Cisco UCS B22 M3 Blade Server 27 CONFIGURING the SERVER SMARTnet for UCS Hardware Only Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty Cisco offers the Cisco SMARTnet for UCS Hardware Only Service You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours SMARTnet for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization RMA is required You can choose a service listed in Table 17 Table 17 SMARTnet for UCS Hardware Only Service Service On er Product ID PID Level GSP Site Description CON UCW7 B22M3 UCW7 Yes UC PLUS 24X7X40S UCS B22 M3 Server CON UCW5 B22M3 UCW5 Yes UC PLUS 8X5XNBDOS UCS B22 M3 Server Unified Computing Partner Support Service Cisco Partner Sup
32. igital Cards Product ID PID PID Description UCS SD 32G S 32 GB SD card module for UCS servers NOTE Due to technical limitations the 32 GB SD card only has a usable capacity of 16 GB regardless of mirroring or not on this particular server model and generation Q Supported Configurations 1 Select one or two Cisco Flexible Flash secure digital cards Cisco UCS B22 M3 Blade Server 21 CONFIGURING the SERVER STEP 8 ORDER OPTIONAL INTERNAL USB 2 0 DRIVE You may order one optional internal USB 2 0 drive The USB drive ordering information is listed in Table 13 Table 13 USB 2 0 Drive Product ID PID PID Description UCS USBFLSH S 4GB 4GB Flash USB Drive shorter length for all servers except C260 NOTE A clearance of 0 950 inches 24 1 mm is required for the USB device to be O inserted and removed see the following figure 2 d9 950 4 CLE NCE FO use To SLIDE DUT pr zzz Th ol IP AP EE als Boo Ni ZZ gt l TO See Figure 6 on page 33 for the location of the USB connector NOTE When the Cisco 4GB USB key is purchased with a server it is pre installed into the internal USB port and held firmly in place with a clip to protect it from shock and vibration during shipment and transportation This clip also prevents the USB key from undergoing shock and vibration during ongoing customer operational use Q 22 Cisco UCS B22 M3 Blade Serv
33. iguration Fabric Extender Adapter Slot 1 Adapter Slot 2 Ports Reference Compatibility 2208XP PIDs UCS IOM 2208XP UCS IOM2208 16FET 2208XP VIC 1240 None 4x 10Gb Figure 11 on page 44 2204XP PIDs UCS IOM 2204XP UCS IOM2204 8FET 2204XP VIC 1240 None 2 x 10 Gb 2104XP PID N20 16584 Figure 12 on page 45 2104XP VIC 1240 None 2 x 10 Gb Figure 13 on page 45 Notes 1 In the server BIOS and on the motherboard Adapter 1 and Adapter 2 are labeled as mLOM and Mezz 1 respectively 2 B22 M3 Configured with 2 CPUs For a B22 M3 configured with 2 CPUs the supported configurations are listed in Table 10 Choose one configuration Table 10 Supported Adapter Combinations Options 2 CPU Configuration achat Adapter Slot 1 Adapter Slot 2 Ports Reference Compatibility 2208XP PIDs UCS IOM 2208XP UCS IOM2208 16FET 2208XP None Emulex or QLogic I O adapter 2 x 10 Gb Figure 14 on page 46 2208XP VIC 1240 None 4 x 10 Gb Figure 15 on page 47 2208XP VIC 1240 Cisco UCS Storage Accelerator 4 x 10 Gb Figure 16 on page 47 2208XP VIC 1240 Emulex or QLogic I O adapter 6 x 10 Gb Figure 17 on page 48 2208XP VIC 1240 VIC 1280 8 x 10 Gb Figure 18 on page 48 18 Cisco UCS B22 M3 Blade Server CONFIGURING the SERVER Table 10 Supported Adapter Combinations Options 2 CPU Configuration continued Fabric Extender Adapter Slot 1 Adapter Slot 2 Compatibility 2204XP PIDs UCS IOM 2204XP UCS IOM2204
34. instructions on how to remove and replace the air baffles see the following link http www cisco com en US docs unified_computing ucs hw chassis install b22 html wp1034378 Cisco UCS B22 M3 Blade Server 39 40 SUPPLEMENTAL MATERIAL CPU Heat Sink Cleaning Kit The cleaning kit is used to remove the existing thermal compound from the bottom of the heat sink during a CPU replacement process Instructions for cleaning are found at the following link http www cisco com en US docs unified_computing ucs hw chassis install b22 html wp1010281 O NOTE When you purchase a spare CPU the CPU cleaning kit is included Cisco UCS B22 M3 Blade Server SUPPLEMENTAL MATERIAL Network Connectivity This section explains how the UCS B22 M3 server connects to Fabric Interconnects using the network I O adapters in the UCS B22 M3 blade server and the Fabric Extender modules in the UCS 5108 blade server chassis The UCS B22 M3 server plugs into the front of the UCS 5108 blade server chassis The Fabric Extender modules plug into the back of the UCS 5108 series blade server chassis A midplane connects the UCS B22 M3 blade server to the Fabric Extenders Figure 9 shows an example configuration where two 2 x 10G KR ports are routed from the VIC 1240 adapter to the Fabric Extender modules and two 2 x 10G KR ports are routed from the mezzanine adapter to the Fabric Extender modules Figure 9 UCS B22 M3 Connections to the Fabric Extenders
35. ion about the KVM local I O cable that plugs into the console connector a cable is included with every Cisco UCS 5100 Series blade server chassis accessory kit see ORDER OPTIONAL KVM LOCAL I O CABLE on page 32 Notes Cisco UCS B22 M3 Blade Server BASE SERVER STANDARD CAPABILITIES and FEATURES BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 lists the capabilities and features of the base server Details about how to configure the server for a particular feature or capability for example number of processors disk drives or amount of memory are provided in CONFIGURING the SERVER on page 7 Table 1 Capabilities and Features Capability Feature Description Chassis The UCS B22 M3 Blade Server mounts in a Cisco UCS 5100 series blade server chassis CPU One or two Intel E5 2400 v2 or E5 2400 series processor family CPUs Chipset Intel C600 series chipset Memory 12 total slots for registered ECC DIMMs for up to 384 GB total memory capacity using 32 GB DIMMs I O Storage controller Internal storage devices Mezzanine adapters m Adapter slot 1 for Cisco s VIC 1240 adapter which provides Ethernet and Fibre Channel over Ethernet FCoE m Adapter slot 2 for various types of Cisco Emulex or QLogic network I O adapters or Cisco UCS Storage Accelerator adapters O NOTE Adapter slot 2 is supported only for 2 CPU system SS configurations LSI Logic SAS 2002 integrated controller m 6 Gbs SAS
36. nterface Card Adapter 2 Converged Network Adapters CNAs UCSB MEZ QLG 03 Cisco UCS CNA M73KR Q QLogic Adapter Adapter 2 UCSB MEZ ELX 03 Cisco UCS CNA M73KR E Emulex Adapter Adapter 2 Cisco UCS Storage Accelerators UCSB F FIO 1600MS UCS 1600 GB Fusion ioMemory3 SX Scale line for B Series Adapter 2 UCSB F FIO 1300MP UCS 1300 GB Fusion ioMemory3 PX Performance line for B Series Adapter 2 UCSB F FIO 785M Cisco UCS 785 GB MLC Fusion ioDrive2 Adapter 2 UCSB F FIO 365M Cisco UCS 365 GB MLC Fusion io ioDrive2 Adapter 2 UCSB F LSI 400S LSI 400 GB SLC WarpDrive Adapter 2 Notes 1 Do not mix Fusion io storage accelerator families That is do not mix MP or MS ioMemory3 with M ioDrive2 family cards Adapter 1 and Adapter 2 refer to the UCS Manager UCSM naming convention for the adapter slots this document uses the UCSM naming convention In the server BIOS and on the motherboard the corresponding slots are labeled as mLOM and Mezz 1 respectively See Table 8 Table 8 Adapter Slot Naming Server BIOS and Motherboard Slot Naming UCSM Slot Naming mLOM VIC 1240 only Adapter 1 Mezz1 Adapter 2 Cisco UCS B22 M3 Blade Server 17 CONFIGURING the SERVER Supported Configurations 1 B22 M3 Configured with 1 CPU For a B22 M3 configured with 1 CPU the supported configurations are listed in Table 9 Choose one configuration Table 9 Supported Adapter Combinations Options 1 CPU Conf
37. o comply with regulatory local and federal requirements If your company has a need to control confidential classified sensitive or proprietary data you might want to consider one of the Drive Retention Services listed in Table 21 Q NOTE Cisco does not offer a certified drive destruction service as part of this service Table 21 Drive Retention Service Options l a Service Service Service Description Program Name Level GSP Service Level Product ID PID SMARTnet for UCS UCSD7 24x7x4 Onsite CON UCSD7 B22M3 Service with Drive UCS DR Retention UCSD7 8x5xNBD Onsite CON UCSD5 B22M3 30 Cisco UCS B22 M3 Blade Server CONFIGURING the SERVER Table 21 Drive Retention Service Options continued Service Description service Service Program Name Level GSP SMARTnet for UCS UCWD7 HW ONLY Drive UCS HW DR Retention UCWD5 For more service and support information see the following URL Service Level 24x 7x4 Onsite 8x5xNBD Onsite Product ID PID CON UCWD7 B22M3 CON UCWD5 B22M3 http www cisco com en US services ps2961 ps10312 Unified_ Computing Services Overview pdf For a complete listing of available services for Cisco Unified Computing System see this URL http www cisco com en US products ps10312 serv_group_home html Cisco UCS B22 M3 Blade Server 31 CONFIGURING the SERVER ORDER OPTIONAL KVM LOCAL I O CABLE The KVM local I O cable ships with every UCS 5100 Series blade server cha
38. port Service PSS is a Cisco Collaborative Services service offering that is designed for partners to deliver their own branded support and managed services to enterprise customers Cisco PSS provides partners with access to Cisco s support infrastructure and assets to help them m Expand their service portfolios to support the most complex network environments m Lower delivery costs m Deliver services that increase customer loyalty Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high value technical support that capitalizes on Cisco intellectual assets This helps partners to realize higher margins and expand their practice PSS is available to all Cisco PSS partners but requires additional specializations and requirements For additional information see the following URL www cisco com go partnerucssupport The two Partner Unified Computing Support Options include m Partner Support Service for UCS m Partner Support Service for UCS Hardware Only 28 Cisco UCS B22 M3 Blade Server CONFIGURING the SERVER Partner Support Service for UCS provides hardware and software support including triage support for third party software backed by Cisco technical resources and level three support See Table 18 Table 18 Partner Support Service for UCS Product ID PID ae ue Description CON PSJ1 B22M3 PSJ1 No UCS SUPP PSS 8X5XNBD UCS B22 M3 Server CON PSJ2 B22M3 PSJ2 No UCS SUP
39. r CIMC GUI or CLI interface enables you to monitor the server inventory health and system event logs The Cisco UCS Blade Server Diagnostics tool for Cisco UCS Blade Servers enables you to verify the health of the hardware components on your servers The diagnostics tool provides a variety of tests to exercise and stress the various hardware subsystems on the Cisco UCS Blade Servers such as memory and CPU You can use the tool to run a sanity check on the state of your Cisco UCS Blade Servers after you fix or replace a hardware component You can also use this tool to run comprehensive burn in tests before you deploy a new Cisco UCS Blade Server in your production environment See the following links for more information User Guide http www cisco com c en us td docs unified_computing ucs sw ucs di agnostics b UCS Blade Server Diagnostics User Guide html ISO Download http www cisco com cisco software navigator html Cisco UCS B22 M3 Blade Server CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS B22 M3 Blade Server STEP 1 VERIFY SERVER SKU page 8 STEP 2 CHOOSE CPU S page 9 STEP 3 CHOOSE MEMORY page 11 STEP 4 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES OPTIONAL page 14 STEP 5 CHOOSE ADAPTERS page 16 STEP 6 ORDER A TRUSTED PLATFORM MODULE page 20 STEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDS page 21 STEP 8 ORDER OPTIONAL INTERNAL USB 2 0 DRIVE pag
40. rver configuration must always have a VIC 1240 installed in the adapter 1 slot Cisco UCS B22 M3 Blade Server 19 CONFIGURING the SERVER STEP 6 ORDER A TRUSTED PLATFORM MODULE Trusted Platform Module TPM is a computer chip microcontroller that can securely store artifacts used to authenticate the platform server These artifacts can include passwords certificates or encryption keys A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy Authentication ensuring that the platform can prove that it is what it claims to be and attestation a process helping to prove that a platform is trustworthy and has not been breached are necessary steps to ensure safer computing in all environments The TPM ordering information is listed in Table 11 Table 11 Trusted Platform Module Product ID PID PID Description UCSX TPM1 001 Trusted Platform Module for UCS NOTE The module used in this server conforms to TPM v1 2 1 3 as defined by the Trusted Computing Group TCG It is also SPl based oO 20 Cisco UCS B22 M3 Blade Server CONFIGURING the SERVER STEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDS Dual SDHC flash card sockets are provided on the front left side of the server as shown in Figure 4 Figure 4 SD Locations 332219 The SDHC card ordering information is listed in Table 12 Table 12 Cisco Flexible Flash Secure D
41. ssis accessory kit The KVM local I O cable provides a connection into the server providing a DB9 serial connector a VGA connector for a monitor and dual USB ports for a keyboard and mouse With this cable you can create a direct connection to the operating system and the BIOS running on the server The KVM local I O cable ordering information is listed in Table 22 Table 22 KVM Local I O Cable Product ID PID PID Description N20 BKVM KVM local IO cable for UCS servers console port Figure 5 KVM Local I O Cable 192621 EE Connector to server front panel VGA connector for a monitor DB 9 serial connector Two port USB connector for a mouse and keyboard Q NOTE The blade chassis ships with the KVM local I O cable 32 Cisco UCS B22 M3 Blade Server SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL System Board A top view of the UCS B22 M3 system board is shown in Figure 6 Figure 6 UCS B22 M3 System Board 1 z O co n R a eia O O O z Ho m U O o o O Q O o Em BO o o B N op on EN O e p 2 Internal USB connector CPU 2 DIMM slots a u 1 and heat sink EE Modular LOM shown installed E 1 DIMM slots Mezzanine adapter connector adapter not shown Notes 1 A USB device installed in this connector must have sufficient clearance to easily sl
42. stfeontas Spec Sheet cisco Cisco UCS B22 M3 Blade Server Cisco SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE CA 95134 REV B 6 MARCH 2 2015 WWW CISCO COM OVERVIEW cia vate eee iReeae td aeed ews Pawnee oO DETAILED VIEWS 6 3 o 06056 OR OES ee we Blade Server Front View 0c0 ccc eee eee eee eeas BASE SERVER STANDARD CAPABILITIES and FEATURES CONFIGURING the SERVER 0000 c enue n annus STEP 1 VERIFY SERVERSKU 2 oO Gp oases So ok a steri e e 8 ee oe ea STEP 2CHOOSE CPUS 22h oes eae eee ee eee ee eo oe eee ee eee STEP 3 CHOOSE MEMORY 2 cece ee eee te ee te ee eee ee ee ee eee 11 STEP 4 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES OPTIONAL 14 SIEP JCHOOSE ADAPTERS sereas ki eee eee eee dee PaaS eos eee ee eae eee 16 STEP 6 ORDER A TRUSTED PLATFORM MODULE 2 2 e eee eee eens 20 STEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDS 0 21 STEP 8 ORDER OPTIONAL INTERNAL USB 2 0 DRIVE 2 0 2 2 eee eee eee 23 STEP 9 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE 24 STEP 10 CHOOSE OPERATING SYSTEM MEDIA KIT 0 2 0 c eee ee eee ee eee 27 STEP 11 CHOOSE SERVICE and SUPPORT LEVEL 2 ce ee eee ee eee 28 ORDER OPTIONAL KVM LOCAL I O CABLE 0 2 2 ee ee ee et te ene 33 SUPPLEMENTAL MATERIAL 0 000 eee ee eee ee ee OF SOM DOA rerne eh eee ad 6 Sie oe Oe ee bee eee ees 8S So
43. tion High Availability 2 Socket 1Yr Svcs Required RHEL Option High Availability 2 Socket 3Yr Svcs Required RHEL Option Resilient w Ha 2 Socket 1 Yr Svcs Required RHEL Option Resilient Storage w HA 2 Socket 3 Yr Svcs Reqd RHEL Option Scalable File System 2 Socket 1 Yr Svcs Required RHEL Option Scalable File System 2 Socket 1 Yr Svcs Required Nexus 1000V for Hyper V and vSphere N1K VSG UCS BUN N1K VLEM UCS 1 VSG VLEM UCS 1 UCS Director CUIC PHY SERV BM U CUIC PHY SERV U CUIC TERM Over half off N1K and VSG w purchase of UCS B C Series Nexus 1000V License Paper Delivery 1 CPU for bundles VSG License Paper Delivery 1 CPU for bundles Cisco Cloupia Resource Lic One Phy Server node bare metal Cisco Cloupia Resource Lic One physical Server node Acceptance of Cisco Cloupia License Terms UCS Performance Manager UCS PM IE UCS PM EE EVAL UCS PM IE EVAL UCS PM EE NFR UCS PM IE NFR UCS PM EE IMC Supervisor EVAL CIMC SUP EVAL CIMC SUP BAS CIMC SUP B01 CIMC SUP B02 CIMC SUP B10 CIMC SUP BASE K9 CIMC SUP TERM VMware 5 VMW VS5 STD 1A VMW VS5 STD 2A VMW VS5 STD 3A VMW VS5 STD 4A VMW VS5 STD 5A 24 UCS Performance Manager UCS Performance Manager Express UCS Performance Manager 60 days evaluation UCS Performance Manager Express 60 days evaluation UCS Performance Manager Not For Resale CS Performance Manager Express Not For Resale EVAL IMC Supervisor Branch Mgt SW for C E Series 50 Svrs EVAL IMC Super
44. ts 10 Choose two identical CPUs from any one of the rows of Table 3 on page 9 For optimal performance select DIMMs with the highest clock speed for a given processor The B22 M3 configured with 1 CPU provides limited network connectivity options The following restrictions apply A virtual interface card VIC the VIC 1240 must always be installed in the VIC 1240 connector The connectivity options are e VIC 1240 installed in VIC 1240 slot adapter 1 slot and no adapter installed in the mezzanine slot adapter 2 slot See Network Connectivity on page 41 for complete information on network connectivity support for a B22 M3 configured with 1 CPU or 2 CPUs The VIC 1240 adapter is supported for 1 or 2 CPU configurations Cisco Emulex or QLogic I O adapters or Cisco UCS Storage Accelerators are supported only for 2 CPU configurations Cisco UCS B22 M3 Blade Server CONFIGURING the SERVER STEP 3 CHOOSE MEMORY The standard memory features are m DIMMs Clock speed 1600 MHz Ranks per DIMM 1 or 2 Operational voltage dual 1 5 or 1 35 V Registered m DDR3 ECC registered DIMMs RDIMMs m Memory is organized with three memory channels per CPU with up to two DIMMs per channel DPC as shown in Figure 3 Maximum memory capacity is 384 GB with 32 GB DIMMs Figure 3 UCS B22 M3 Memory Organization pm r OS T a faa faa co co B1 BO FO F1 Channel B Channel F Chann
45. ured with 2 CPUs Connectivity using the Cisco UCS 2208XP Fabric Extender The Cisco UCS 2208XP is the second generation Fabric Extender and shares the same form factor as the current UCS 2100 series The 2208XP is backwards compatible with the UCS 5108 Blade server chassis The options shown in Figure 14 through Figure 18 demonstrate how the server uses these options Emulex or QLogic I O adapter to 2208XP VIC 1240 to 2208XP VIC 1240 and Cisco UCS Storage Accelerator to 2208XP VIC 1240 and Emulex or QLogic I O adapter to 2208XP m VIC 1240 and VIC 1280 to 2208XP In Figure 14 there is no VIC 1240 adapter installed In this case a Cisco Emulex or QLogic I O adapter must be installed in the adapter 2 slot Ports A and B of the mezzanine adapter connect to the Fabric Extenders providing 10 Gbps per port Figure al 14 Option 1 Emulex or QLogic I O Adapter to UCS 2208XP Fabric Extender no VIC 1240 adapter Pir a 10G KR E 10G KR Emulex or QLogic O Adapter No VIC 1240 Adapter Installed Adapter Slot 2 Adapter Slot 1 Ptle x16 46 Cisco UCS B22 M3 Blade Server SUPPLEMENTAL MATERIAL In Figure 15 there is no mezzanine adapter installed Two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The result is 20 Gbps of bandwidth to each Fabric Extender Figure 15 Option 2 VIC 1240 to UCS 2208XP Fabric Extender no mezzanine adapter
46. visor One time Site Installation License IMC Supervisor Branch Mgt SW for C Series amp E Series up to 100 Svrs IMC Supervisor Branch Mgt SW for C Series amp E Series up to 250 Svrs IMC Supervisor Branch Mgt SW for C Series amp E Series up to 1K Svrs IMC Supervisor One time Site Installation License Acceptance of Cisco IMC Supervisor License Terms VMware vSphere 5 Standard for 1 Processor 1 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 2 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 3 Year Support Rad VMware vSphere 5 Standard for 1 Processor 4 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 5 Year Support Rqd Cisco UCS B22 M3 Blade Server CONFIGURING the SERVER Table 14 OSs and Value Added Software for 2 CPU servers continued PID Description VMW VS5 ENT 1A VMW VS5 ENT 2A VMW VS5 ENT 3A VMW VS5 ENT 4A VMW VS5 ENT 5A VMW VS5 ENTP 1A VMW VS5 ENTP 2A VMW VS5 ENTP 3A VMW VS5 ENTP 4A VMW VC5 STD 1A VMW VC5 STD 2A VMW VC5 STD 3A VMW VC5 STD 4A VMW VC5 STD 5A Product ID PID VMware vSphere 5 Enterprise for 1 Processor 1 Year Support Rqd VMware vSphere 5 Enterprise for 1 CPU 2 Yr Support Rqd VMware vSphere 5 Enterprise for 1 CPU 3 Yr Support Rqd VMware vSphere 5 Enterprise for 1 Processor 4 Year Support Rqd VMware vSphere 5 Enterprise for 1 CPU 5 Yr Support Rqd VMware vSphere 5 Enterprise Plus for 1 Processor 1 Year Support Rqd VMware vSphere 5 Enterprise Plus
47. xtenders the maximum bandwidth per half width B22 blade is 4 x 10Gb With two 2208XP fabric extenders the maximum bandwidth per half width B22 blade is 8 x 10 Gb VIC 1240 Adapter The only adapter that can be plugged in to the VIC 1240 slot is the VIC 1240 a Cisco designed PCle based adapter that in the UCS B22 M3 server provides up to four depending on the Fabric Extender option chosen 10 Gigabit Data Center Ethernet DCE network interfaces Two ports are wired through the UCS 5108 Blade Server chassis to Fabric Extender A and to Fabric Extender B as represented in Figure 10 Figure 10 VIC 1240 Port Connectivity Pie Variable of ports depends on mezz card type Port Group A Port Group B Mezzanine Adapter VIC 1240 Adapter Adapter 2 Slot Adapter 1 Slot PCle 16 PCle x8 42 Cisco UCS B22 M3 Blade Server SUPPLEMENTAL MATERIAL Mezzanine Adapters There are multiple options for the mezzanine slot m O based PCle adapters such as network adapters or m Cisco UCS Storage Accelerators such as memory cards Q NOTE In a B22 M3 configured with 2 CPUs if a UCS B22 M3 blade server does not have a VIC 1240 installed the mezzanine slot is required to have a network adapter installed In a B22 M3 configured with 1 CPU however a VIC 1240 must always be installed Specific examples of mezzanine adapters are m Cisco adapters VIC 1280 m Emulex and QLogic I O adapters
48. your operations 29 CONFIGURING the SERVER You can choose a service listed in Table 20 Table 20 UCS Computing Combined Support Service Product ID PID ees sae Description CON NCF2 B22M3 NCF2 No CMB SPT SVC 24X7X2 UCS B22 M3 Server CON NCF2P B22M3 NCF2P Yes CMB SPT SVC 24X7X20S UCS B22 M3 Server CON NCF4P B22M3 NCF4P Yes CMB SPT SVC 24X7X40S UCS B22 M3 Server CON NCF4S B22M3 NCF4S Yes CMB SPT SVC 8X5X40S UCS B22 M3 Server CON NCFCS B22M3 NCFCS Yes CMB SPT SVC 8X5XNBDOS UCS B22 M3 Server CON NCFE B22M3 NCFE No CMB SPT SVC 8X5X4 UCS B22 M3 Server CON NCFP B22M3 NCFP No CMB SPT SVC 24X7X4 UCS B22 M3 Server CON NCFT B22M3 NCFT No CMB SPT SVC 8X5XNBD UCS B22 M3 Server Unified Computing Drive Retention Service With the Cisco Unified Computing Drive Retention UCDR Service you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive In exchange for a Cisco replacement drive you provide a signed Certificate of Destruction CoD confirming that the drive has been removed from the system listed is no longer in service and has been destroyed Sophisticated data recovery techniques have made classified proprietary and confidential information vulnerable even on malfunctioning disk drives The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised which reduces the risk of any potential liabilities This service also enables you t

Download Pdf Manuals

image

Related Search

Related Contents

Dell Data Protection  Smeg KIT73636X  Samsung CJX-1050W Benutzerhandbuch  Bedienungsanleitung Operating instructions  Philips Voice Tracer digital recorder DVT5000  EPP-200 Precision Plasmarc Cutting Console  Texte intégral PDF (551 ko)  Fujitsu LIFEBOOK E733  LAVAPISTOLE INOX HOT H2H Mod. H2H  SISTEMA INFOMEX- Gobierno Federal  

Copyright © All rights reserved.
Failed to retrieve file