Home
Intel I350-T4V2
Contents
1. e Up to 8 Virtual Functions per Port e Assigns time slices in equal portions in circular order for Rx Tx for balanced bandwidth allocation e Processes or VMs can be assigned a dedicated VF with VLAN support e Offloads sorting and classifying traffic in to VF or queues e On chip VM VM traffic enables PCle speed switching between VM e Enables anti spoofing filter on MAC addresses and VLAN for VFs e Monitors queues and VFs for malformed descriptors that might indicate a malicious or buggy driver I O Virtualization Features continued Features Storm control Per pool statistics offloads and jumbo frames support Independent Function Level Reset FLR for Physical and Virtual Functions IEEE 802 1q Virtual Local Area Network VLAN support with VLAN tag insertion stripping and packet filtering for up to 4096 VLAN tags IEEE 802 1q advanced packet filtering Mirroring rules Support for Simple VEPA VF Promiscuous modes Stateless Offloads Performance Features Benefits e Limits to the broadcast or multicast traffic it can receive e Each Queue Pair or Pool has its own statistics off loads and Jumbo support options e VF resets only the part of the logic dedicated to specific VF and does not influence the shared port e Adding for transmits and removing for receives of VLAN tags with no VM involvement e Filtering packets belonging to certain VLANs e Lower processor utilization e Ability to reflect network traffic to a gi
2. RIGHTS IS GRANTED BY THIS DOCUMENT EXCEPT AS PROVIDED IN INTEL S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DIS CLAIMS ANY EXPRESS OR IMPLIED WARRANTY RELATING TO SALE AND OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE MERCHANTABILITY OR INFRINGEMENT OF ANY PATENT COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT A Mission Critical Application is any application in which failure of the Intel Product could result directly or indirectly in personal injury or death SHOULD YOU PURCHASE OR USE INTEL S PRODUCTS FOR ANY SUCH MISSION CRITICAL APPLICATION YOU SHALL INDEMNIFY AND HOLD INTEL AND ITS SUBSIDIARIES SUBCONTRACTORS AND AFFILIATES AND THE DIRECTORS OFFICERS AND EM PLOYEES OF EACH HARMLESS AGAINST ALL CLAIMS COSTS DAMAGES AND EXPENSES AND REASONABLE ATTORNEYS FEES ARISING OUT OF DIRECTLY OR INDIRECTLY ANY CLAIM OF PRODUCT LIABILITY PERSONAL INJURY OR DEATH ARISING IN ANY WAY OUT OF SUCH MISSION CRITICAL APPLICATION WHETHER OR NOT INTEL ORITS SUBCONTRACTOR WAS NEGLIGENT IN THE DESIGN MANUFACTURE OR WARNING OF THE INTEL PRODUCT OR ANY OF ITS PARTS Intel may make changes to specifications and product descriptions at any time without notice Designers must not rely on the absence or characteristics of any features or instructions marked reserved or undefined Intel reserves these for future definition and shall h
3. go network UEFI 2 3 N y N Service and availability may vary by country VMware ESX 4 0 n a Y n a VMware ESX 4 13 n a y n a To see the full line of Intel Ethernet Controllers VMware ESX 5 0 Wa Y n a visit www intel com go ethernet For more information contact your Intel sales Xen n a Y n a representative Key Y affected N not affected n a OS not available on specified architecture n s OS not supported by LADSW on specified architecture 1 Itaniun Product Family 2 Minimal Validation 3 VMware ESX drivers are not included on LAD SW Release CDs They are available only from VMware s web site and are released on a separate schedule 4 SR IOV validation only 1 Feature to be enabled in Post Launch Release NOTE Low Halogen applies only to halogenated flame retardants and PVC in components Halogens are below 1 000ppm bromine and 1 000ppm chlorine By using this document in addition to any agreements you have with Intel you accept the terms set forth below You may not use or facilitate the use of this document in connection with any infringement or other legal analysis concerning Intel products described herein You agree to grant Intel a non exclusive royalty free license to any patent claim thereafter drafted which includes subject matter disclosed herein INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS NO LICENSE EXPRESS OR IMPLIED BY ESTOPPEL OR OTHERWISE TO ANY INTELLECTUAL PROPERTY
4. multiprocessor systems e Enables higher and better throughput of data e Based on the sensitivity of the incoming data the controller can bypass the automatic moderation of time intervals between the interrupts e Helps the driver to focus on the relevant part of the packet without the need to parse it e Provides hints on a per transaction basis e Optimized descriptor fetch and write back for efficient system memory and PCle bandwidth usage Remote Boot Options Features Preboot execution Environment PXE flash interface support Intel Ethernet iSCSI Remote Boot for Windows Linux and VMware Intel Boot Agent software Linux boot via PXE or BOOTP Windows Deployment Services or UEFI Benefits e Enables system boot up via the EFI 32 bit and 64 bit e Flash interface for PXE 2 1 option ROM e Enables system boot up via iSCSI e Provides additional network management capability e Enables networked computer to boot using a program code image supplied by a remote server e Complies with the Pre boot eXecution Environment PXE Version 2 1 Specification Manageability Features Features Management Component Transport Protocol MCTP Firmware Based Thermal Management IEEE 802 3 MII Management Interface MAC PHY Control and Status Watchdog timer Extended error reporting Controller Memory Protection 4 Benefits e Baseboard management controller BMC communication between add in devices using a standardized protoco
5. E T operation e Fiber MMF 62 5 50 um e 10 100 1000 Mbps Copper 1000 Mbps Fiber e PCI Express 2 1 5 GT s e 4 lane PCI Express operable in x4 x8 and x16 slots e INTA INTB INTC INTD MSI MSI X e FCC B UL CE VCCI BSMI CTICK KCC e Intel Ethernet Controller 1350 e Copper I350T2V2 4 4 W I350T4V2 5 0 W e Fiber I350F2 5 5 W I350F4 6 0 W e 0 C to 55 C 32 F to 131 F e 40 C to 70 C 40 F to 158 F e 90 non condensing relative humidity at 35 C Connect Speed LED Indicators e Not illuminated 10 Mb s green 100 Mb s amber 1 Gb s Copper e Green 1 Gb s Not illuminated no link Fiber Physical Dimensions Copper T2 amp T4 Fiber F2 Length e 13 54 cm 5 33 in Width e 6 89 cm 2 71 in Full height end bracket e 12 0 cm 4 725 in Low profile end bracket e 7 92 cm 3 117 in Fiber F4 Length e 13 54 cm 5 33 in Width 11 12 cm 4 376 in Full height end bracket 12 0 cm 4 725 in Low profile end bracket N A O1 Operating System Architecture Support Product Codes OPERATING SYSTEM IA32 X64 IPF Dual Port Copper CODE Windows Server 2003 SP2 y y N Intel Ethernet Server Adapter 1350 T2 I350T2V2 m T a CC Bulk Pack RJ45 IEEE I350T2V2BLK Windows Server 2008 SP2 YoY N eee Gals aman ok i ke Ga ge ee Quad Port Copper CODE Windows Server 2008 SP2 Core Y Y n a i T Intel Ethernet Server Adapter 1350 T4V2 I350T4V2 Windows Server 2008 SP2 w Hyper V role n a Y n a Bul
6. Halogen free dual or quad port Gigabit Ethernet adapters with copper or fiber interface options Innovative power management features including Energy Efficient Ethernet EEE and DMA Coalescing for increased efficiency and reduced power consumption Flexible I O virtualization for port partitioning and quality of service QoS of up to 32 virtual ports Scalable iSCSI performance deliver ing cost effective SAN connectivity High performing bridgeless design Supporting PCI Express Gen 2 1 5GT s Reliable and proven Gigabit Ethernet technology from Intel Corporation The new Intel Ethernet Server Adapter 1350 family builds on Intel s history of excel lence in Ethernet products Intel continues its market leadership with this new genera tion of PCle GbE network adapters Built with the bridgeless Intel Ethernet Controller 1350 these adapters represent the next step in the Gigabit Ethernet GbE networking evolution for the enterprise and data center by introducing new levels of performance through industry leading enhancements for both virtualized and iSCSI Unified Network ing environments This new family of adapters also includes new power management technologies such as Energy Efficient Ethernet EEE and DMA Coalescing DMAC The Intel Ethernet Server Adapter 1350 family includes Intel Virtualization Technology for connectivity Intel VT c to deliver I O virtualization and Quality of Service QoS features designed
7. ave no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them The information here is subject to change without notice Do not finalize a design with this information The products described in this document may contain design defects or errors known as errata which may cause the product to deviate from published spe cifications Current characterized errata are available on request Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order Copies of documents which have an order number and are referenced in this document or other Intel literature may be obtained by calling 1 800 548 4725 or go to http www intel com design literature Atm Intel and Intel logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries E Copyright 2014 Intel Corporation f nN e Other names and brands may be claimed as the property of others Printed in USA 0914 LH RE Recycle 325511 006US 6
8. chronizes DMA calls across all controller ports to ensure maximum power Savings Software Tools and Management Intel Advanced Network Services Intel ANS include new teaming technologies and techniques such as Virtual Machine Load Balancing VMLB for Hyper V environments Today Intel ANS includes a variety of teaming configurations for up to eight adapters support for mixed vendors server adapters teaming and includes support for 802 1q VLANs making Intel ANS one of the most capable and comprehensive tools for Supporting server adapter teaming Additionally Intel PROSet for Windows Device Manager and PROset CL extends driver functionality to provide additional reliability and Quality of Service features and configuration With DMA Coalescing High Ti Power Low Normal Power EEE Enabled Source Intel Labs Energy Efficient Ethernet reduces the con troller power to approximately 50 of its normal operating level As shown by the red line components have less time between DMA calls to reach and Stay in lower power states With more time between DMA calls com ponents can reach lower power states and remain in them longer General Features Features Intel Ethernet Controller 1350 with PCI Express V2 1 5 GT s Support Halogen Free Copper Low Profile Dual and Quad Port Copper Dual Port Fiber and Standard height Quad Port Fiber Benefits e Industry leading smallest non bridge
9. d PCle Gen2 quad port 1 GbE controller e Enables customers to take full advantage of 1 GbE by providing maximum bi directional throughput per port ona single quad port adapter e Leadership in an environmentally friendly ecosystem e Enables higher bandwidth and throughput from standard and low profile PCle slots and servers Ethernet Features Features IEEE 802 3 auto negotiation 1Gb s Ethernet IEEE 802 3 802 3u 802 3ab PHY specifications Compliant Integrated PHY for 10 100 1000 Mb s for multispeed full and half duplex IEEE 802 3x and 802 3z compliant flow control support with software controllable Rx thresholds and Tx pause frames Automatic cross over detection function MDI MDI X IEEE 1588 protocol and 802 1AS implementation Benefits e Automatic link configuration for speed duplex flow control e Robust operation over installed base of Category 5 twisted pair cabling e Smaller footprint and lower power dissipation compared to multiple discreet MAC and PHY e Local control of network congestion levels e Frame loss reduced from receive overruns e The PHY automatically detects which application is being used and configures itself accordingly e Time stamping and synchronization of time sensitive applications e Distribute common time to media devices Power Management and Efficiency Features lt 1W SO Max state JOOOBASE T Active 900C mode lt 400mW SO Typ state IJOOBASE T Active mode IEEE802 3az E
10. directly into the controller on the adapter I O virtualization advances network connectivity models used in today s servers to more efficient models by pro viding Flexible Port Partitioning FPP multiple Rx Tx queues and on controller QoS functionality that can be used in both virtual and non virtual server deployments By taking advantage of the PCI SIG SR IOV specification Intel Ethernet products en able Flexible Port Partitioning FPP With FPP virtual controllers can be used by the Linux host directly and or assigned to virtual machines With this port partitioning administrators can create up to eight dedicated connections ona single Ethernet port for use in bare metal and virtualized server deployments In a bare metal Linux server host processes can be assigned to dedicated network resources to provide traffic isolation and balanced bandwidth allocation In a virtualized environment a VM can be assigned to a virtual controller to reduce the CPU overhead seen when using a software based network bridge by offloading network traffic management to the controller Scalable iSCSI Performance An Intel Ethernet Server Adapter 1350 with native iSCSI initia tors built into Microsoft Windows Linux and VMware ESX platforms provides a simple dependable cost effective way to connect to iSCSI SANs These native initiators are broadly tested using multiple generations of operating systems stor age systems and OS tools to help
11. ensure reliability and ease of use Standardizing on Intel Ethernet Adapters for iSCSI enables administrators to use a single initiator TCP IP stack and a common set of management tools and IT policies In addition Intel Ethernet Server Adapters include a number of hardware features designed to accelerate iSCSI traffic and enhance data processing For example TCP segmentation offload and checksum offload capabilities help reduce proces sor usage increase throughput and deliver exceptional iSCSI performance Finally using native OS initiators an Intel Ether net Server Adapter 1350 supports the CRC 32 digest instruc tion set included with Intel Xeon processor products which improves transmission reliability and delivers an enterprise class iSCSI solution Power Management Technologies Today companies everywhere are looking for ways to de crease energy consumption across the enterprise to reduce costs and environmental impact while at the same time solv ing increasingly important power density challenges That s why Intel has introduced new advanced Power Management Technologies PMTs with the Intel Ethernet Server Adapter 1350 family that enable enterprises to configure power op tions on the adapter and more effectively manage their power consumption Energy Efficient Ethernet EEE The Intel Ethernet Server Adapter 1350 family supports the IEEE802 3az Energy Efficient Ethernet EEE standard so that during period
12. k Pack Order 5 Get 5 RJ45 IEEE N 2 Hyper V Server 2008 SP2 n a Y n a Dual Port Fiber CODE Windows Server 2008 R2 n a Y N Intel Ethernet Server Adapter 1350 F2 I350F2 Windows Server 2008 R2 Core n a Y N Bulk Pack Order 5 Get 5 LC Fiber Optic IEEE I350F2BLK Windows Server 2008 R2 w Hyper V role n a ye n a Quad Port Fiber CODE Hyper V Server 2008 R2 ma y2 aie Intel Ethernet Server Adapter I350 F4 I350F4 Bulk Pack Order 5 Get 5 LC Fiber Optic IEEE IS50F4BLK WinPE 1 6 2003 PE Y Y n a WinPE 2 1 2008 PE y y n a For Product Information To see the full line of Intel Network Adapters for PCI Express visit www WinPE 3 0 2008 R2 PE y Y n a intel com go ethernet Linux Stable Kernel version 3 X 2 6 X y y n a To speak to a customer service representative regarding Intel products please call 1 800 538 3373 U S and Canada or visit support intel com Linux RHEL 5 6 Y Y N support go network contact htm for the telephone number in your area Linux RHEL 6 1 Y Y n a Warranty Linux SLES 10 SPA y y n a Limited lifetime hardware warranty within 90 days of purchase See the support document for complete warranty information at Linux SLES 11 SP1 7 Y N www intel com support network sb cs 009721 htm DOS NDIS 2 Y n a n a Customer Support DOS ODI y n a n a Intel Customer Support Services offers a broad selection of programs including phone support and warranty service For more information MEF 221 N Y N contact us at support intel com support
13. l e Can be programmed via the BMC to initiate thermal actions and report thermal occurrences e Enables the MAC and software to monitor and control the state of the PHY e Enhanced control capabilities through PHY reset link status duplex indication and MAC Dx power state e Defined by the FLASHT register to minimize Flash updates e Messaging support to communicate multiple types severity of errors e Main internal memories are protected by error correcting code ECC or parity bits Adapter Product Features Plug and play specification support e Standard Intel I O Acceleration Technology Intel I OAT e Extreme system throughput Ships with full height bracket installed low profile bracket Streamlines installation included in package T2 T4 and F2 Cable distance Intel Backing Limited Lifetime Warranty 90 day money back guarantee U S and Canada Specifications General Connectors e RJ 45 Copper IEEE standard network topology Cabling Technical Data rate supported per port Bus type Bus width Interrupt levels Hardware certifications Controller processor Power consumption typical Operating temperature Storage temperature Storage humidity e Copper up to 100 m e Fiber up to 300 m e LC Fiber Optic Fiber e IEEE 802 3 10BASE T TOOBASE TX TOOOBASE T e Copper Category 3 or higher for 1OBASE T operation Category 5 or higher for IOOBASE TX operation Category 5e or higher for IOOOBAS
14. nergy Efficient Ethernet EEE DMA Coalescing Smart Power Down SPD at SO no link Sx no link Active State Power Management ASPM Support LAN disable function Full wake up support e Advanced Power Management APM Support formerly Wake on LAN e Advanced Configuration and Power Interface ACPI specification v2 0c e Magic Packet wake up enable with unique MAC address ACPI register set and power down functionality supporting DO and D3 states MAC Power Management controls Low Power Link Up Link Speed Control Power Management Protocol Offload Proxying Latency Tolerance Reporting LTR I O Virtualization Features Benefits e Controller is designed for low power consumption e Power consumption of the PHY is reduced by approximately 50 link transitions to low power Idle LPI state as defined in the IEEE802 3az EEE standard e Reduces platform power consumption by coalescing aligning and synchronizing DMA e Enables synchronizing port activity and power management of memory CPU and RC internal circuitry e PHY powers down circuits and clocks that are not required for detection of link activity e Optionality Compliance bit to help determine whether to enable ASPM or whether to run ASPM compliance tests to support entry to LOs e Option to disable the LAN Port and or PCle Function Disabling just the PCle function but keeping the LAN port that resides on it fully active for manageability purposes and BMC pa
15. s of low network activity EEE reduces the power High Power Low Without DMA Coalescing consumption of an Ethernet connection by negotiating with a compliant EEE switch port to transition to a low power idle LPI state This reduces the controller power to approximately 50 of its normal operating power saving power on the net work port and the switch port As soon as increased network traffic is detected the controller and the switch quickly come back to full power to handle the increased network traffic EEE is supported for both TIOOOBASE T and 100BASE TX DMA Coalescing Another power management technology that can reduce power on the server platform is DMA Coalescing DMAC Typically when a packet arrives at a server DMA calls are made to transfer the packet within the server These calls wake up the processor memory and other system compo nents from a lower power state in order to perform the tasks required to handle the incoming packet Based on the configurable DMAC settings incoming packets are buffered momentarily before any DMA calls are made This enables the controller to intelligently identify opportunities to batch multiple packets together so that when components are wakened from lower power states they can efficiently handle the batched packets at the same time This enables platform components to remain in lower power states longer which can dramatically reduce platform energy consumption DMAC syn
16. ss through traffic e APM Designed to receive a broadcast or unicast packet with an explicit data pattern Magic Pack and assert a signal to wake up the system e ACPI PCle power management based wake up that can generate system wake up events from a number of sources e A power managed link speed control lowers link speed and power when highest link performance is not required e Power management controls in the MAC the PHY can be entered into a low power state e Enables a link to come up at the lowest possible speed in cases where power is more important than performance e Avoid spurious wake up events and reduce system power consumption when the device is in D3 low power state and system is in S3 or S4 low power states e Reports service latency requirements for memory reads and writes to the Root Complex for system power management Features Eight transmit Tx and receive Rx queue pairs per port Flexible Port Partitioning 32 Virtual Functions on Quad port or 16 Virtual Functions on Dual port Support for PCI SIG SR IOV specification Rx Tx Round Robin Scheduling Traffic Isolation Traffic Steering VM to VM Packet forwarding Packet Loopback MAC and VLAN anti spoofing Malicious driver detection Benefits e Supports VMware NetQueue and Microsoft VMQ e Virtual Functions VFs appear as Ethernet Controllers in Linux OSes that can be assigned to VMs Kernel processes or teamed using the Linux Bonding Drivers
17. ven VM or VLAN based on up to four rules e Support for external VM switching e VLAN unicast multicast Features TCP UDP IPv4 checksum offloads Rx Tx Large send Extended Tx descriptors for more offload capabilities IPv6 support for IP TCP and IP UDP receive checksum offload Tx TCP segmentation offload IPv4 IPv6 Transmit Segmentation Offloading TSO Interrupt throttling control Legacy and Message Signal Interrupt MSI Modes Message Signal Interrupt Extension MSI X Intelligent interrupt generation Receive Side Scaling RSS for Windows environment Scalable I O for Linux environments IPv4 IPv6 TCP UDP Support for packets up to 9 5K Bytes Jumbo Frames Low Latency Interrupts Header packet data split in receive PCle v2 1 TLP Processing Hint Requester Descriptor ring management hardware for Transmit and Receive Benefits e Improved CPU usage e Checksum and segmentation capability extended to new standard packet type e Improved CPU usage e Increased throughput and lower processor usage e Compatible with large send offload e Large TCP UDP I O is segmented by to the device it to L2 packets according to the requested MSS e Limits maximum interrupt rate and improves CPU utilization e Interrupt mapping e Dynamic allocation of up to 25 vectors per port e Enhanced software device driver performance e Up to eight queues per port e Improves the system performance related to handling of network data on
Download Pdf Manuals