Home
Socomec NETYS RT 11000VA
Contents
1. e STANDARDS Performance amp topology EN 62040 3 VFI SS 111 Safety EMC EN 62040 1 TUV GS certified EN 62040 2 Product certifications CE TUV GS C Tick IP rating IP20 ENVIRONMENT Operating ambient temperature from 0 C to 40 C from 15 C to 25 C for best battery life Storage temperature range from 15 C to 50 C from 15 C to 25 C for best battery life Relative Humidity 0 90 non condensing Noise level ISO 3746 lt 450B lt 55 dB DIMENSIONS amp WEIGHT UPS size std W x D x H 88 7x332x 440 mm 88 7x430x440 mm 88 7x430x440 mm 88 7x608x440 mm 177 4x670x440 mm 177 4x670x440 mm 261 2x623x440 mm 261 2x623x440 mm UPS size RACK 2U 2U 2U 2U 2U 2U 2U 2U 3U 3U 3U 3U UPS weight std 13 kg 21 kg 22 kg 31 kg 15 5 40 kg 16 40 kg 19 5 66 kg 20 66 kg EBM module size W x D x H 88 7x332x 440 mm 88 7x430x440 mm 88 7x430x440 mm 88 7x608x440 mm 88 7x608x440mm 88 7x608x440 130 6x623x440 mm 130 6x623x440 mm EBM module RACK 2U 2U 2U 2U 2U 2U 3U 3U EBM module weight 16 kg 29 kg 29 kg 43 kg 40 kg 40 kg 66 kg 66 kg 75 of nominal load 7 50comec Innovative Power Solutions Catalogue 2013 17 NeTYS RT from 1100 to 11000 VA Single phase UPS Connections Converts from Tower to Rack mounted 2 8 9 4 5 6 9 10 11 T 1100 VA 1700 VA 2200 VA 3000 VA 10 5 17 6 11 2 2 16 12 15 13 14 5000 VA 7000 VA battery 9000 VA 11000 VA battery 1 Mains input
2. 1100 VA 1700 VA 2200 VA 3000 VA 5000 VA 7000 VA 9000 VA 11000 VA Pn 800 W 1200 W 1600 W 2100 W 4500 W 5400 W 7200 W 9000 W Architecture online double conversion VFI with input PFC and automatic bypass Parallel redundant function 1 1 1 1 1 1 1 1 INPUT Voltage 230 V 1ph 160 275 Vac up to 130 Vac 70 load 230 V 1ph 181 280 Vac up to 100 Vac 50 load Frequency 50 60 Hz 10 Auto Selectable Power factor THDi gt 0 98 lt 6 gt 0 99 lt 5 OUTPUT Voltage 230 V 1ph selectable 200 208 220 240V 50 or 60 Hz 2 0 05 Hz in battery mode Efficiency up to 91 online mode up to 92 online mode Overload capability up to 105 continuously 125 x 3 min 150 x 30 sec up to 105 continuously 125 x 5 min 150 x 30 sec Output connections 6x a T 3 6 x IEC 320 C13 10 A 1 x IEC 320 C20 16 A terminals BATTERY Standard autonomy 8 12 8 10 8 6 8 6 Voltage 24 Vdc 48 Vdc 48 Vdc 72 dc 192 Vdc 192 Vde 240 Vdc 240 Vdc Recharge time lt 6 hr to recover 90 capacity lt 6 hr to recover 90 capacity COMMUNICATION Mimic panel LED LCD 6 languages RS232 MODBUS protocol USB HID protocol e e e e WEB SNMP Ethernet RJ45 port option option option option e e COMM slot e e e e e e e e Dry contacts card option option option option option option option option EPO input RJ11 port Modem ADSL surge protection Parallel port e
3. Single phase UPS Simple to install e IEC input and output connections 1100 3000 VA or terminal input and output connections with built in magnetothermal input switch 5000 11000 VA e Compact footprint for installation in rack cabinets e Attractive design Easy to use e No configuration necessary on first startup e Wide range of communication protocols for integration into LAN networks or Building Management Systems BMS e Clear LED interface with buzzers that immediately indicate the operating status of the UPS even for less specialist users 1100 3000 VA e LCD display with menu available in 6 languages 5000 11000 VA Catalogue 2013 NeCTYS RT from 1100 to 11000 VA complete solution for IT infrastructures lt Ww xt oO Meets practical needs e Online double conversion technology with sinusoidal waveform completely filters out all disturbances from to the mains power supply and ensures maximum protection of the utility e Modular battery extension EBM to meet all back up time requirements even after installation e Possibility of 1 1 parallel redundant configuration to maximise the availability of critical utilities even in the event of a module breakdown 5000 11000 VA The solution for gt Switching gt Storage gt Servers and networking devices gt VolP communication systems gt Structured cabling systems gt Control systems gt Video surveillanc
4. e systems Technology gt VFI online double conversion Certifications a pad lt T V T V Rheinland Gr SW gy o S o inland Group F O 7000009 S N876 N876 BACK UP TIME Be WEB SNMP 7 s0comec Innovative Power Solutions NeTYS RT from 1100 to 11000 VA Single phase UPS Standard communication features e LOCAL VIEW ideal UPS monitoring and shutdown point to point solution for Windows Linux and Mac OS X operating systems e HID UPS management based on Windows and Mac OS X embedded service USB interface 1100 3000 VA e MODBUS JBUS RTU RS232 e RT VISION professional WEB SNMP interface for UPS monitoring and shutdown management of several operating systems 5000 11000 VA Standard electrical features Communication options e Built in backfeed protection e Protection against atmospheric phenomena NTP for telephone ADSL modems e RJ11 connection for Emergency Power Off EPO e Connection for battery extension modules e Port for parallel operation 5000 11000 VA e RT VISION professional WEB SNMP interface for UPS monitoring and shutdown management of several operating systems 1100 3000 VA e Dry contact interface Electrical options e 1 1 parallel module 5000 11000 VA e Manual bypass without interruption 5000 11000 VA e Battery extension modules Technical data N TYS RT Sn
5. nd can therefore be set up at a later date simply by using two UPS modules and a collector manual bypass module which simplifies cabling and maintenance of the UPS installation To further streamline the solution it is also possible to select between operation with separate battery or shared battery which is extremely useful in the case of applications requiring high levels of autonomy Yellow LED lit Operation in bypass mode Green LED lit Mains healthy OFF button Green LED lit Normal operation inverter in line ON TEST and buzzer override button LED bar Depending on the situation this indicates either the charge level or the capacity of the battery Navigator buttons Alphanumeric LCD display Green LED lit Status of the load O 0l OND oO O N Catalogue 2013 19
6. socket IEC 320 10 Battery extension connector 2 Fan 11 Slot for optional communication boards 3 Output socket full power 12 Battery extension connector 4 Telephone modem line protection 13 Output terminals 5 EPO Emergency Power Off input 14 Input terminals 6 RS232 interface MODBUS protocol 15 Input switch 7 USB port 16 RJ45 LAN ethernet connector 8 Input protection 17 Parallel port connector 9 Output sockets IEC 320 10 A 18 Catalogue 2013 Ja socomec Innovative Power Solutions APPLI 057 058 059 060 061 062 063 064 A NETYS115 A NETYS 118 B GB NETYS116 A NETYS 119 B GB N TYS RT 1100 3000 VA Battery extension Back up time minutes UPS EBM 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 NRT U1100 Internal p NRT U1100 1xNRT B81100 S NRT U1100 2xNRT B1100 S i NRT U1700 Internal NRT U1700 1xNRT B2200 S i NRT U1700 2xNRT B2200 SR NRT U2200 Internal NRT U2200 1xNRT B2200 S NRT U2200 2xNRT B2200 l NRT U3000 Internal Se NRT U3000 1x NRT B3000 NRT U3000 2x NRT 83000 UPS 2 EBM 50 of nominal load NeTYS RT 5000 11000 VA UPS NRT2 5000K NRT2 5000K NRT2 5000K NRT2 7000K NRT2 7000K NRT2 7000K NRT2 9000K NRT2 9000K NRT2 9000K UPS standard UPS 1 EBM UPS 2 EBM NRT2 11000K NRT2 11000K 1 x NRT B11000 NRT2 11000K 2 x NRT B11000 EBM Standard 1 x NRT B7000 2 x NRT B7000 S
7. tandard 1 x NRT B7000 2 X NRT B7000 Standard 1 x NRT B11000 2 x NRT B11000 Standard 50 of nominal load Control panel ETYS 108A 1100 VA 1700 VA 2200 VA 3000 VA 7 50comec Innovative Power Solutions 75 of nominal load m 100 of nominal load Battery extension Back up time minutes 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 l arjan F a r _ A dl E 75 of nominal load 100 of nominal load oko NETYS 110A ONNO 5000 VA 7000 VA 9000 VA 11000 VA NETYS 117 A GB NeTYS RT from 1100 to 11000 VA Single phase UPS Parallel redundant operation for business continuity To achieve the highest level of availability and to power critical utilities NETYS RT UPS modules above 3 kVA can be configured for 1 1 redundancy Redundant operation 1 1 means the system incorporates one more UPS module than is needed to protect the load in the event of a breakdown it guarantees sufficient power supply capacity to the load by maintaining online protection Parallel technology is based on the principle of load sharing whereby both units are always kept active In a redundant configuration overall system availability is much higher than a conventional UPS system using similar technology 1 1 redundant configuration does not require additional circuits a
Download Pdf Manuals
Related Search
Related Contents
ICEE15A-462 ショップチャンネル視聴ガイド JVC KW-NT3HDT Product Comparison Chart M POUR PRESSOIRS A MEMBRANE N° Réf: 40 90 04 ARCPOW-06C10/12/15 - Arcus Elektronika Diseño Asistido y Visualización 取扱説明書 Contrôleur KAPPA Soft version 3.xx MANUEL D`UTILISATION User`s Manual - Field Wireless Copyright © All rights reserved.