Home

IBM System x 3750 M4

image

Contents

1. Partnumber Feature Description Maximum code supported 2 5 inch SSDs Enterprise 49Y6195 A4GH IBM 1 6TB SAS 2 5 MLC HS Enterprise SSD 16 49Y6139 A3F0 IBM 800GB SAS 2 5 MLC HS Enterprise SSD 16 49Y6134 A3EY IBM 400GB SAS 2 5 MLC HS Enterprise SSD 16 49Y6129 A3EW IBM 200GB SAS 2 5 MLC HS Enterprise SSD 16 41Y8331 A4FL 3700 200GB SATA 2 5 MLC HS Enterprise SSD 16 41Y8336 A4FN 3700 400GB SATA 2 5 MLC HS Enterprise SSD 16 41Y8341 A4FQ 3700 800GB SATA 2 5 MLC HS Enterprise SSD 16 2 5 inch SSDs Enterprise Value 00AJ000 A4KM 3500 120GB SATA 2 5 MLC HS Enterprise Value SSD 16 00AJ005 A4KN 3500 240GB SATA 2 5 MLC HS Enterprise Value SSD 16 00AJ010 A4KP 3500 480GB SATA 2 5 MLC HS Enterprise Value SSD 16 00AJ015 A4KQ S3500 800GB SATA 2 5 MLC HS Enterprise Value SSD 16 1 8 inch SSDs Enterprise 41Y8366 A4FS 3700 200GB SATA 1 8 MLC Enterprise SSD 32 41Y8371 A4FT S3700 400GB SATA 1 8 MLC Enterprise SSD 32 1 8 inch SSDs Enterprise Value 00AJ040 A4KV 3500 80GB SATA 1 8 MLC Enterprise Value SSD 32 00AJ045 A4KW 3500 240GB SATA 1 8 MLC Enterprise Value SSD 32 00AJ050 A4KX 3500 400GB SATA 1 8 MLC Enterprise Value SSD 32 00AJ455 A58U 3500 800GB SATA 1 8 MLC Enterprise Value SSD 32 Internal backup units The server does not supports any internal backup units such as tape drives or RDX dr
2. Maximum quantity supported is shown for four processors installed When two processors are installed the maximum quantity supported is a half of the quantity that is shown When one processor is installed the quantity is one quarter of that shown The following memory protection technologies are supported ECC Chipkill for x4 based memory DIMMs look for x4 in the DIMM description Memory mirroring Memory rank sparing If memory mirroring is used then DIMMs must be installed in pairs minimum of one pair per CPU and both DIMMs in a pair must be identical in type and size If memory rank sparing is used then a minimum of one quad rank DIMM or two single rank or dual rank DIMMs must be installed per populated channel the DIMMs do not need being identical In rank sparing mode one rank of a DIMM in each populated channel is reserved as spare memory The size of a rank varies depending on the DIMMs installed IBM System x3750 M4 E5 4600 v2 12 Internal storage The server can support up to 16x 2 5 inch drives up to 32x 1 8 inch drives or a combination of both 2 5 inch and 1 8 inch hot swap drives using the supported SAS SATA backplane configurations The server supports 2 5 inch hot swap SAS or hot swap SATA hard disk drives 2 5 inch hot swap SATA solid state drives or 1 8 inch hot swap SATA solid state drives
3. Partnumber Feature Description Maximum code supported 2 5 inch 10K SAS Hot Swap HDDs 00AD075 A48S IBM 1 2TB 10K 6Gbps SAS 2 5 G2HS HDD 16 81Y9650 A282 IBM 900GB 10K 6Gbps SAS 2 5 SFF HS HDD 16 90Y8872 A2XD IBM 600GB 10K 6Gbps SAS 2 5 SFF G2HS HDD 16 90Y8877 A2XC IBM 300GB 10K 6Gbps SAS 2 5 SFF G2HS HDD 16 2 5 inch 15K SAS Hot Swap HDDs 81Y9670 A283 IBM 300GB 15K 6Gbps SAS 2 5 G2HS HDD 16 90Y8926 A2XB IBM 146GB 15K 6Gbps SAS 2 5 SFF G2HS HDD 16 90Y8944 A2ZK IBM 146GB 15K 6Gbps SAS 2 5 SFF G2HS SED 16 2 5 inch NL SATA Hot Swap HDDs 81Y9730 A1AV IBM 1TB 7 2K 6Gbps NL SATA 2 5 SFF HS HDD 16 81Y9722 A1NX IBM 250GB 7 2K 6Gbps NL SATA 2 5 SFF HS HDD 16 81Y9726 A1NZ IBM 500GB 7 2K 6Gbps NL SATA 2 5 SFF HS HDD 16 2 5 inch NL SAS Hot Swap HDDs 81Y9690 A1P3 IBM 1TB 7 2K 6Gbps NL SAS 2 5 SFF HS HDD 16 90Y8953 A2XE IBM 500GB 7 2K 6Gbps NL SAS 2 5 SFF G2HS HDD 16 2 5 inch SAS Hot Swap SEDs 00AD085 A48T IBM 1 2TB 10K 6Gbps SAS 2 5 G2HS SED 16 81Y9662 A3EG IBM 900GB 10K 6Gbps SAS 2 5 SFF G2HS SED 16 90Y8908 A3EF IBM 600GB 10K 6Gbps SAS 2 5 SFF G2HS SED 16 90Y8913 A2XF IBM 300GB 10K 6Gbps SAS 2 5 SFF G2HS SED 16 SAS SSD hybrid drives 00AD102 A4G7 IBM 600GB 10K 6Gbps SAS 2 5 G2HS Hybrid 16 IBM System x3750 M4 E5 4600 v2 16 Table 9 Disk drive options for internal disk storage Part 2
4. 172701X IBM System Storage EXP3000 18 9 per port 174712X IBM System Storage EXP2512 Express 18 9 per port 174724X IBM System Storage EXP2524 Express 9 9 per port The hard disk drives listed in Table 20 are supported with external expansion enclosures Table 20 Hard drive options for external expansion enclosures Part 1 Part number Description Maximum quantity supported per one enclosure EXP3000 Hot Swap SATA 3 5 in Hard Drives 43W7630 1000 GB Dual Port Hot Swap SATA 12 49Y1940 IBM 2 TB 7200 Dual Port SATA 3 5 in HS HDD 12 EXP3000 Hot Swap SAS 3 5 in Hard Drives 44W2234 IBM 300 GB 15 K 6 Gbps SAS 3 5 in Hot Swap HDD 12 44W2239 IBM 450 GB 15 K 6 Gbps SAS 3 5 in Hot Swap HDD 12 44W2244 IBM 600 GB 15 K 6 Gbps SAS 3 5 in Hot Swap HDD 12 EXP2512 Hot Swap SAS 3 5 in Hard Drives 49Y1899 300 GB 15 K 6 Gb SAS 3 5 in HDD 12 49Y1900 450 GB 15 K 6 Gb SAS 3 5 in HDD 12 49Y1901 600 GB 15 K 6 Gb SAS 3 5 in HDD 12 49Y1903 1 TB 7 200 RPM 6 Gb SAS NL 3 5 in HDD 12 43W7630 1000 GB Dual Port Hot Swap SATA 12 49Y1902 2 TB 7 200 RPM 6 Gb SAS NL 3 5 in HDD 12 90Y8720 3 TB 7 200 RPM 6 Gb SAS NL 3 5 in HDD 12 IBM System x3750 M4 E5 4600 v2 29 Table 20 Hard drive options for external expansion enclosures Part 2 Part
5. 10 Gb Ethernet 94Y5180 A4Z6 Broadcom NetXtreme Dual Port 10GbE SFP Adapter for IBM System x 8 49Y7910 A18Y Broadcom NetXtreme II Dual Port 10GBaseT Adapter for IBM System x 8 4201820 1637 Brocade 10Gb CNA for IBM System x 8 00D8540 A4M9 Emulex Dual Port 10GbE SFP VFA Ilir for IBM System x 8 49Y7960 A2EC Intel X520 Dual Port 10GbE SFP Adapter for IBM System x 8 49Y7970 A2ED Intel X540 T2 Dual Port 10GBaseT Adapter for IBM System x 8 00D9690 A3PM Mellanox ConnectX 3 10 GbE Adapter for IBM System x 8 42C1800 5751 QLogic 10Gb CNA for IBM System x 8 90Y4600 A3MR QLogic 8200 Dual Port 10GbE SFP VFA for IBM System x 8 4709952 A47H Solarflare SFN5162F 2x10GbE SFP Performant Adapter for IBM 8 System x 47C9960 A473 Solarflare SFN6122F 2x10GbE SFP Onload Adapter for IBM System x 8 Gigabit Ethernet 90Y9352 A2V3 Broadcom NetXtreme Quad Port GbE Adapter for IBM System x 8 90Y9370 A2V4 Broadcom NetXtreme Dual Port GbE Adapter for IBM System x 8 49Y4230 5767 Intel Ethernet Dual Port Server Adapter 1340 T2 for IBM System x 8 49Y4240 5768 Intel Ethernet Quad Port Server Adapter I1340 T4 for IBM System x 8 InfiniBand 00D9550 A3PN Mellanox ConnectX 3 40GbE FDR IB VPI Adapter for IBM System x 8 Maximum quantity is achieved with processor 2 installed and the 3 slot riser card 88Y7371 With one processor the maximum quantity is three this maximum does not apply to the 10 Gb cards in the dedicated slot For more information see the list of
6. certification at high voltage AC The Intel Xeon processor E5 4600 v2 product family offers better performance over the previous generation E5 4600 although it fits into the same TDP limits Intel Intelligent Power Capability powers individual processor elements on and off as needed to reduce power draw Low voltage Intel Xeon processors draw less energy to satisfy the demands of power and thermally constrained data centers and telecommunication environments Low voltage 1 35 V DDR3 memory RDIMMs consume 19 less energy compared to 1 5 V DDR3 RDIMMs Solid state drives SSDs consume as much as 80 less power than traditional spinning 2 5 inch HDDs The server uses hexagonal ventilation holes which are a part of IBM Calibrated Vectored Cooling technology Hexagonal holes can be grouped more densely than round holes providing more efficient airflow through the system IBM Systems Director Active Energy Manager provides advanced data center power notification and management to help achieve lower heat output and reduced cooling needs Locations of key components and connectors Figure 2 shows the front of the server USB 2 0 Video Ports Status Light path lights diagnostics Optical Hot swap drive bays panel amp release drive 16x 2 5 HDDs or 32x 1 8 SSDs Figure 2 Front view of the IBM System x3750 M4 Figure 3 shows the rear of the server 3 optional PCle 5 standard PCle Two hot swap adapter
7. 46W0761 A47K 32GB 1x32GB 4Rx4 1 5V PC3 14900 CL13 ECC DDR3 48 12 per 1866MHz LP LRDIMM processor The following rules apply when selecting the memory configuration e The server supports RDIMMs and LRDIMMs UDIMMs are not supported e Mixing different types of memory RDIMMs and LRDIMMs is not supported e Mixing 1 5 V and 1 35 V DIMMs in the same server is supported in such a case all DIMMs operate at 1 5 V e The maximum number of ranks per one channel is eight with the exception of Load Reduced DIMMs where more than eight ranks are supported because one quad rank LRDIMM provides the same electrical load on a memory bus as a single rank RDIMM e The maximum quantity of DIMMs that can be installed in the server depends on the number of processors installed The table shows the maximum when all four processors are installed When two processors are installed the maximum quantity supported is a half of the quantity that is shown e All DIMMs in the server operate at the same speed which is determined as the lowest value of e Memory speed that is supported by the specific processor e Lowest of maximum operating speeds for selected memory configuration that depends on rated speed operating voltage and quantity of DIMMs per channel as shown under Max operating speed section in the next table IBM System x3750 M4 E5 4600 v2 Table highlighting e The entries highlighted in red t
8. FC Dual port HBA for IBM System x 8 42D0501 3578 QLogic 8Gb FC Single port HBA for IBM System x 8 SAS 46C9010 A3MV N2125 SAS SATA HBA for IBM System x 8 Maximum quantity is achieved with processor 2 and the 3 slot riser card 88Y7371 installed With one processor the maximum quantity is three For more information see the list of IBM Redbooks Product Guides in the Host bus adapters category http www redbooks ibm com portals systemx Open amp page pg amp cat hba IBM System x3750 M4 E5 4600 v2 22 PCle SSD adapters The server supports the High IOPS SSD adapters listed Table 15 Note The server supports a maximum quantity of three of the full height adapters which must be installed in slots 1 2 and 3 These slots require the second processor and the 3 slot riser card 88Y7371 Table 15 SSD adapters Part number Feature Description Maximum code supported 90Y4377 A3DY IBM 1 2TB High IOPS MLC Mono Adapter 7 90Y4397 A3DZ IBM 2 4TB High IOPS MLC Duo Adapter 3 46C9078 A3J3 IBM 365GB High IOPS MLC Mono Adapter 7 46C9081 A3J4 IBM 785GB High IOPS MLC Mono Adapter 7 90Y4361 A3MZ IBM 300GB High IOPS MLC Modular Adapter 3 90Y4365 A3N0 IBM 600GB High IOPS MLC Modular Adapter 3 90Y4369 A3N1 IBM 800GB High IOPS MLC Modular Adapter 3 90Y4373 A3N2 IBM 300GB High IOPS SLC Modular A
9. IBM Redbooks Product Guides in the Networking adapters category http www redbooks ibm com portals systemx Open amp page pg amp cat networkadapters IBM System x3750 M4 E5 4600 v2 21 Storage host bus adapters Table 14 lists storage HBAs supported by x3750 M4 server The maximum quantity is achieved with processor 2 and the 3 slot riser card 88Y 7371 installed With one processor the maximum quantity is three this configuration does not apply to the 10 Gb cards in the dedicated slot Table 14 Storage adapters Part number Feature Description Maximum code supported Fibre Channel 16 Gbps 81Y1675 A2XV Brocade 16Gb FC Dual port HBA for IBM System x 8 81Y1668 A2XU Brocade 16Gb FC Single port HBA for IBM System x 8 81Y1662 A2W6 Emulex 16Gb FC Dual port HBA for IBM System x 8 81Y1655 A2W5 Emulex 16Gb FC Single port HBA for IBM System x 8 00Y3341 A3KX QLogic 16Gb FC Dual port HBA for IBM System x 8 00Y3337 A3KW QLogic 16Gb FC Single port HBA for IBM System x 8 Fibre Channel 8 Gbps 46M6050 3591 Brocade 8Gb FC Dual port HBA for IBM System x 8 46M6049 3589 Brocade 8Gb FC Single port HBA for IBM System x 8 42D0494 3581 Emulex 8Gb FC Dual port HBA for IBM System x 8 42D0485 3580 Emulex 8Gb FC Single port HBA for IBM System x 8 42D0510 3579 QLogic 8Gb
10. USB 2 0 one DB 15 video one DB 9 serial one RJ 45 systems management ports mezzanine LOM adapter with either four 1 GbE network ports or two 10 GbE RJ 45 or SFP network ports in dedicated slot Internal Two internal USB ports for the embedded hypervisor Cooling IBM Calibrated Vectored Cooling with up to six N N redundant hot swap fans all six standard each fan has two rotors Power supply Up to two hot swap redundant AC power supplies 80 PLUS Platinum certification Standard models use 900W supplies available 1400W AC and 750W DC options Second power supply requires processor expansion tray 88Y7365 or the power interposer card 88Y7367 installed Video Matrox G200eR2 with 16 MB memory integrated into the IMM2 Maximum resolution is 1600x1200 at 75 Hz with 16 M colors Hot swap parts Drives power supplies and fans Systems UEFI IBM Integrated Management Module II IMM2 Predictive Failure Analysis Light Path management Diagnostics Automatic Server Restart IBM Systems Director and Active Energy Manager and the IBM ServerGuide IMM Advanced Upgrade software feature for remote presence are standard with the x3750 M4 Security Power on password administrator s password Trusted Platform Module TPM features Operating Microsoft Windows Server 2008 R2 2012 2012 R2 RHEL 6 x64 SLES 11 x64 VMware systems vSphere 5 1 5 5
11. You can mix drives in the same server if you do not mix drives on the same array Backplanes IBM System x3750 M4 server supports various internal storage configurations based on four different backplanes e 4 drive backplane for 2 5 inch drives Up to four backplanes can be installed each requiring one SAS connection to a supported controller One RAID controller can connect to two of these backplanes e 8 drive backplane for 2 5 inch drives Up to two backplanes can be installed each requiring two SAS connections One RAID controller per backplane e 8 drive backplane with a SAS expander for 2 5 inch drives Use with the other 2 5 inch drive backplanes 8 drive or one 4 drive or two 4 drive backplanes which will result in being able to connect up to 16 2 5 inch drive bays to the one RAID controller e 8 drive backplane for 1 8 inch solid state drives eXFlash Pack Up to four backplanes can be installed each requiring two SAS connections One RAID controller per backplane Cannot be connected to the 8 drive backplane with a SAS expander When building drive backplane configurations all 1 8 inch SSD drive backplanes must be installed to the right of all 2 5 inch HDD or 2 5 inch SSD drive backplanes when looking at the front of the server Every four drives uses a SAS signal cable except when the 8 drive backplane with SAS expander is used When the 8 drive backplane with SAS expander is used the other backplanes connect to the SAS e
12. countries Linux is a trademark of Linus Torvalds in the United States other countries or both LTO Ultrium the LTO Logo and the Ultrium logo are trademarks of HP IBM Corp and Quantum in the U S and other countries Microsoft Windows and the Windows logo are trademarks of Microsoft Corporation in the United States other countries or both Java and all Java based trademarks and logos are trademarks or registered trademarks of Oracle and or its affiliates Other company product or service names may be trademarks or service marks of others IBM System x3750 M4 E5 4600 v2 43
13. memory expansion tray standard on most models Two QPI links up to 8 0 GTps each Chipset Intel C600 series Memory Up to 48 DIMM sockets 12 DIMMs per processor RDIMMs and LRDIMMs Load Reduced DIMMs are supported but memory types cannot be intermixed The memory speed is up to 1866 MHz There are 24 DIMM sockets on the system board There are an additional 24 DIMM sockets on the processor and memory expansion tray standard on most models Memory With RDIMMs Up to 768 GB with 48x 16 GB RDIMMs and four processors maximums With LRDIMMs Up to 1 5 TB with 48x 32 GB LRDIMMs and four processors Memory ECC Chipkill for x4 based memory DIMMs memory mirroring and memory sparing protection Disk drive bays Up to 16 2 5 inch hot swap SAS SATA bays or up to 32 1 8 inch hot swap solid state drive SSD eXFlash bays Drive bays can be in any combination of four 2 5 inch drives or eight 1 8 inch eXFlash SSD drives Maximum Up to 25 6 TB with 1 6 TB 2 5 SSDs up to 19 2 TB with 1 2 TB 2 5 SAS HDDs up to 16 TB with 1 TB 2 5 NL SAS SATA HDDs Intermix of SAS SATA supported RAID support RAID 0 1 10 with integrated ServeRAID M5210e with LSI SAS3108 RAID on Chip ROC controller Optional upgrades to RAID 5 and 50 are available 1GB cache no battery or 1 or 2 GB flash backed cache Optional upgrades to RAID 6 and 60 when cache is also installed Optical drive There is one bay for an optional Multiburner drive bays T
14. one stop shopping for a total IT solution so you can acquire IBM hardware software services and the financing you need from one IT provider Plus we provide simple easy to understand contracts and quick approvals As the world s largest IT financing provider with an asset base of US 35 8 billion and over 125 000 customers IBM Global Financing offers highly competitive rates that promote low total cost of ownership and low monthly payments IBM Global Financing operates in more than 50 countries Go to the following website for financing options in your country and to contact a local financing specialist http ibm com financing IBM Global Financing offerings are provided through IBM Credit LLC in the United States and other IBM subsidiaries and divisions worldwide to qualified commercial and government clients Rates and availability subject to client s credit rating financing terms offering type equipment and product type and options and might vary by country Non hardware items must be one time nonrecurring charges and are financed by using loans Other restrictions might apply Rates and offerings are subject to change extension or withdrawal without notice and might not be available in all countries Contact your local IBM Global Financing representative for additional detail IBM System x3750 M4 E5 4600 v2 40 Related publications and links For more information see these resources IBM US Announcement Letter http i
15. routing requirements One of the supported riser cards must be installed These slots also require that Processor 2 be installed IBM System x3750 M4 E5 4600 v2 Table 8 lists the optional upgrades supported with the ServeRAID controllers Table 8 RAID controller upgrades Part number Feature Description Upgrade Maximum code type supported 47C8656 A3Z0 ServeRAID M5200 Series 1GB Cache RAID 5 Upgrade Hardware 4 47C8660 A3Z1 ServeRAID M5200 Series 1GB Flash RAID 5 Upgrade Hardware 4 47C8664 A3Z2 ServeRAID M5200 Series 2GB Flash RAID 5 Upgrade Hardware 4 47C8706 A3Z5 ServeRAID M5200 Series RAID 6 Upgrade FoD FoD 1 47C8708 A3Z6 ServeRAID M5200 Series Zero Cache RAID 5 FoD FoD 1 47C8710 A3Z7 ServeRAID M5200 Series Performance FoD 1 Accelerator FoD 4708712 A3Z8 ServeRAID M5200 Series SSD Caching Enabler FoD FoD 1 M5200 RAID upgrades require one of the cache upgrades 47C8656 47C8660 or 47C8664 IBM System x3750 M4 E5 4600 v2 Internal drive options Table 9 lists the hard disk drive options for the internal disk storage of the x3750 M4 server Table 9 Disk drive options for internal disk storage Part 1
16. server contains IBM Integrated Management Module II IMM2 which provides advanced service processor control monitoring and alerting functions If an environmental condition exceeds a threshold or if a system component fails the IMM2 lights LEDs to help you diagnose the problem records the error in the event log and alerts you to the problem A virtual presence capability also comes standard in this server for remote server management Remote server management is provided through industry standard interfaces Intelligent Platform Management Interface IPMI Version 2 0 Simple Network Management Protocol SNMP Version 3 Common Information Model CIM Web browser The server also supports virtual media and remote control features which provide the following functions Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel regardless of the system state Remotely accessing the server using the keyboard and mouse from a remote client Mapping the CD or DVD drive diskette drive and USB flash drive on a remote client and mapping ISO and diskette image files as virtual drives that are available for use by the server Uploading a diskette image to the IMM2 memory and mapping it to the server as a virtual drive Capturing blue screen errors Supported operating systems The server supports the following operating systems Microsoft Windows Server 2012 R2 Microsoft Windows Server 2012 Micros
17. slots adapter slots power supplies eee eee _ i x Y e Seesecese E PATTON OPTASE SEa Dae ir wit ay Mezzanine LOM ML2 slot with either Ethernet Video Serial Status Two USB four 1 GbE ports or two 10 GbE ports port for IMM port port LEDs ports dedicated slot Figure 3 Rear view of the IBM System x3750 M4 machine type 8752 IBM System x3750 M4 E5 4600 v2 Figure 4 shows the locations of key components inside the server Processor and memory CPUs 1 amp 2 and Mezzanine expansion tray with CPU 3 amp 4 24 DIMM sockets LOM and 24 DIMM sockets under expansion tray adapter Hot swap power supplies Hot swap CPU3with CPU 4with 12 PCleriser Five PCle USB fan packs 12 DIMMs DIMMs with 3 slots slots ports Figure 4 Inside view of the IBM System x3750 M4 machine type 8752 IBM System x3750 M4 E5 4600 v2 Standard specifications Table 1 lists the standard specifications Table 1 Standard specifications part 1 Components Specification Machine type 8752 Form factor 2U rack internal storage Processor Up to four Intel Xeon E5 4600 v2 processors each with 12 cores 2 4 GHz ten cores up to 2 4 GHz eight cores up to 3 3 GHz six cores 2 6 GHz or four cores 2 2 GHz Up to 1866 MHz memory speed Up to 30 MB L3 cache per processor Two processor sockets on the system board and two processors on the processor and
18. supported Limited Three year customer replaceable unit and onsite limited warranty with 9x5 next business day warranty NBD Service and Optional service upgrades are available through IBM ServicePac offerings Four hour or support two hour response time eight hour fix time one year or two year warranty extension remote technical support for IBM hardware and some IBM and third party applications Dimensions Height 86 mm 3 4 in width 445 mm 17 5 in depth 746 mm 29 4 in Weight Minimum configuration 25 kg 55 Ib maximum 30 kg 65 Ib The x3750 M4 servers are shipped with the following items Statement of Limited Warranty Important Notices Rack Installation Instructions Documentation CD that contains the nstallation and User s Guide IBM System x Gen lll Slides Kit IBM System x Gen lIl Cable Management Arm CMA 2 8 m 9 2 ft C13 C14 power cord one for models with one power supply and two for models with two power supplies IBM System x3750 M4 E5 4600 v2 Standard models Table 2 lists the standard models Table 2 Standard models Model Intel Xeon processor Memory RAID Hot swap Disks PCle GbEt Power four maximum RDIMMs controller disk bays supply Models announced March 2014 8752 A1x 2x E5 4627 v2 8C 3 3GHz 2x 8 GB M5210e 4x 2 5 Open 5 8 4x 1GbE 1x 900W 16MB 1866MHz 130W 1866 MHz 16 max 8752 A2
19. to an IBM product program or service is not intended to state or imply that only that IBM product program or service may be used Any functionally equivalent product program or service that does not infringe any IBM intellectual property right may be used instead However it is the user s responsibility to evaluate and verify the operation of any non IBM product program or service IBM may have patents or pending patent applications covering subject matter described in this document The furnishing of this document does not give you any license to these patents You can send license inquiries in writing to IBM Director of Licensing IBM Corporation North Castle Drive Armonk NY 10504 1785 U S A The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This information could include technical inaccuracies or typographical errors Changes are periodically made to the information herein these changes will be incorporated in new editions of the publication IBM may make
20. 00 V 120 V 53952KX IBM 2200VA LCD 2U Rack UPS 230 V 53953AX IBM 3000VA LCD 3U Rack UPS 100 V 120 V 53953J5X IBM 3000VA LCD 3U Rack UPS 200 V 208 V 53956AX IBM 6000VA LCD 4U Rack UPS 200 V 208 V 53959KX IBM 11000VA LCD 5U Rack UPS 200 V 208 V 230 V For more information see the list of IBM Redbooks Product Guides in the Power infrastructure category http www redbooks ibm com portals systemx Open amp page pg amp cat power IBM System x3750 M4 E5 4600 v2 35 Power distribution units The server supports attachments to the power distribution units PDUs listed in Table 27 Table 27 Power distribution units part 1 Part number Description Switched and Monitored PDUs 46M4002 IBM 1U 9 C19 3 C13 Active Energy Manager DPI PDU 46M4003 IBM 1U 9 C19 3 C13 Active Energy Manager 60A 3 Phase PDU 46M4004 IBM 1U 12 C13 Active Energy Manager DPI PDU 46M4005 IBM 1U 12 C13 Active Energy Manager 60A 3 Phase PDU 46M4167 IBM 1U 9 C19 3 C13 Switched and Monitored 30A 3 Phase PDU 46M4116 IBM OU 24 C13 Switched and Monitored 30A PDU 46M4134 IBM OU 12 C19 12 C13 Switched and Monitored 50A 3 Phase PDU Enterprise PDUs 71762NX IBM Ultra Density Enterprise PDU C19 PDU WW 71763MU IBM Ultra Density Enterprise PDU C19 3 Phase 60A PDU NA 71763NU IBM Ultra Density Enterprise PDU C19 3 Phase 60A PDU NA 39M2816 IBM DPI C
21. 13 Enterprise PDU without power cord 39Y8923 DPI 60A Three Phase C19 Enterprise PDU with IEC309 3P G 208 V fixed power cord 39Y8941 DPI Single Phase C13 Enterprise PDU without power cord 39Y8948 DPI Single Phase C19 Enterprise PDU without power cord Front end PDUs 39Y8938 30 A 125 V Front end PDU with NEMA L5 30P connector 39Y8939 30 A 250 V Front end PDU with NEMA L6 30P connector 39Y8940 60 A 250 V Front end PDU with IEC 309 60A 2P N Gnd connector IBM System x3750 M4 E5 4600 v2 36 Table 27 Power distribution units part 2 Part number Description Universal PDUs 39Y8951 DPI Universal Rack PDU with US LV and HV line cords 39Y8952 DPI Universal Rack PDU with CEE7 VII Europe LC 39Y8953 DPI Universal Rack PDU with Denmark LC 39Y8954 DPI Universal Rack PDU with Israel LC 39Y8955 DPI Universal Rack PDU with Italy LC 39Y8956 DPI Universal Rack PDU with South Africa LC 39Y8957 DPI Universal Rack PDU with UK LC 39Y8958 DPI Universal Rack PDU with AS NZ LC 39Y8959 DPI Universal Rack PDU with China LC 39Y8962 DPI Universal Rack PDU Argentina 39Y8960 DPI Universal Rack PDU Brazil 39Y8961 DPI Universal Rack PDU India OU Basic PDUs 46M4125 IBM OU 24 C13 30A 3 Phase PDU 46M4128 IBM OU 24 C13 30
22. 5000 meters 44X4152 A54E IBM 1400W HE Redundant Power Supply 2 88Y7431 A2A7 IBM 900 W Power Supply 2 All models 88Y7433 A2EA IBM System x 4S 750W High Efficiency 48 V DC 2 Power Supply 88Y7367 A2A0 IBM Power Interposer for Redundant Power Supply 1 The power interposer is not needed if the processor and memory expansion tray 88Y7365 is installed Each AC power supply ships standard with one 2 8 m C13 C14 power cord Two installed power supplies form a redundant pair Under extreme configurations with two 1400 W supplies installed it might still be possible to exceed 1400 W DC output If this condition exists and a power supply fails the server caps power at 1400 W until the second power supply is back online Integrated virtualization The server supports VMware ESXi installed on a USB memory key The key is installed in a USB socket inside the server Table 17 lists the virtualization options Table 17 Virtualization options Part number Feature Description Maximum code supported 41Y8298 A2G0 IBM Blank USB Memory Key for VMware ESXi Downloads 1 Download a supported VMware vSphere hypervisor image from http ibm com systems x os vmware and load it on the memory key using the instructions provided IBM System x3750 M4 E5 4600 v2 24 Remote management The
23. 600 v2 Key features The IBM System x3750 M4 blends outstanding flexibility and expandability The x3750 M4 2 2 socket design enables pay as you grow processing with the new Intel Xeon E5 4600 v2 series processors and memory scalability to help lower cost and manage growth The 5 3 PCle socket design allows you to pay for PCle capabilities as needed With the capability to support up to 48 DIMMs four sockets mix and match internal storage with up to 16 HDDs or 32 eXFlash SSD drives 6 hot swap dual rotor fans two power supplies and a dedicated slot for Gigabit or 10 GbE networking with options the x3750 M4 provides unmatched features and capabilities in a dense 2U design Scalability and performance The x3750 M4 offers numerous features to boost performance improve scalability and reduce costs IBM System x3750 M4 E5 4600 v2 The Intel Xeon processor E5 4600 v2 family improves productivity by offering superior system performance It provides increased productivity by offering processors up to 12 cores each and processors with core speeds up to 3 3 GHz L3 cache up to 30 MB and two QuickPath Interconnect QPI interconnect links operating at up to 8 GTps The x3750 M4 2 2 processor socket design enables pay as you grow processing with the Intel Xeon E5 4600 v2 series processors and memory scalability to help lower cost and manage growth Up to four processors 48 cores and 96 threads maximize the concurrent execution of multithre
24. A PDU 46M4140 IBM OU 12 C19 12 C13 60A 3 Phase PDU For more information see the list of IBM Redbooks Product Guides in the Power infrastructure category http www redbooks ibm com portals systemx Open amp page pg amp cat power IBM System x3750 M4 E5 4600 v2 37 Rack cabinets The server supports the rack cabinets listed in Table 28 Table 28 Rack cabinets Part number Description 93072PX IBM 25U Static S2 Standard Rack 93072RX IBM 25U Standard Rack 93074RX IBM 42U Standard Rack 93074XX IBM 42U Standard Rack Extension 93084EX IBM 42U Enterprise Expansion Rack 93084PX IBM 42U Enterprise Rack 93604EX IBM 42U 1200 mm Deep Dynamic Expansion Rack 93604PX IBM 42U 1200 mm Deep Dynamic Rack 93614EX IBM 42U 1200 mm Deep Static Expansion Rack 93614PX IBM 42U 1200 mm Deep Static Rack 93624EX IBM 47U 1200 mm Deep Static Expansion Rack 93624PX IBM 47U 1200 mm Deep Static Rack 99564RX IBM S2 42U Dynamic Standard Rack 99564XX IBM S2 42U Dynamic Standard Expansion Rack For more information see the list of IBM Redbooks Product Guides in the Rack cabinets and options category http www redbooks ibm com portals systemx Open amp page pg amp cat rack IBM System x3750 M4 E5 4600 v2 38 Rack options The server supports the rack console switches and m
25. Networking RackSwitch G8264CS Front to Rear 7309BD5 IBM System Networking RackSwitch G8124DC 7309BR6 IBM System Networking RackSwitch G8124ER 7309BF7 IBM System Networking RackSwitch G8124EF 7309G64 IBM System Networking RackSwitch G8264R 730964F IBM System Networking RackSwitch G8264F 7309CR9 IBM System Networking RackSwitch G8264TR 7309CF9 IBM System Networking RackSwitch G8264TF 0719410 Juniper Networks EX4500 Front to Back Airflow 0719420 Juniper Networks EX4500 Back to Front Airflow IBM System Networking 40 Gb top of rack switches 8036BRX IBM System Networking RackSwitch G8332 Rear to Front 8036BFX IBM System Networking RackSwitch G8332 Front to Rear 8036ARX IBM System Networking RackSwitch G8316R 8036AFX IBM System Networking RackSwitch G8316F For more information see the list of IBM Redbooks Product Guides in the Top of rack switches category http www redbooks ibm com portals systemx Open amp page pg amp cat tor IBM System x3750 M4 E5 4600 v2 34 Uninterruptible power supply units The server supports attachments to the uninterruptible power supply UPS units listed in Table 26 Table 26 Uninterruptible power supply units Part number Description Rack mounted UPS 21304RX IBM UPS 10000XHV 53952AX IBM 2200VA LCD 2U Rack UPS 1
26. U Intel Xeon E5 4603 v2 4C 2 2GHz 10MB 1333MHz 95W 8752 A2x 00D1953 A43L A43V Intel Xeon E5 4607 v2 6C 2 6GHz 15MB 1333MHz 95W 8752 A3x 00D1958 A43M A43W Intel Xeon E5 4610 v2 8C 2 3GHz 16MB 1600MHz 95W 8752 B1x 00D1963 A43N A43X Intel Xeon E5 4620 v2 8C 2 6GHz 20MB 1600MHz 95W 8752 B2x 00D1978 A43R A440 Intel Xeon E5 4627 v2 8C 3 3GHz 16MB 1866MHz 130W 8752 A1x 00D0574 A452 A453 Intel Xeon E5 4624L v2 10C 1 9GHz 25MB 1866MHz 70W 00D1968 A43P A43Y Intel Xeon E5 4640 v2 10C 2 2GHz 20MB 1866MHz 95W 8752 C1x 00D1973 A43Q A43Z Intel Xeon E5 4650 v2 10C 2 4GHz 25MB 1866MHz 95W 8752 C2x 00D1988 A43T A442 Intel Xeon E5 4657L v2 12C 2 4GHz 30MB 1866MHz 115W The first feature code corresponds to the first processor installed the second feature is for all additional processors Memory options IBM DDR3 memory is compatibility tested and tuned for optimal System x performance and throughput IBM memory specifications are integrated into the light path diagnostics for immediate system performance feedback and optimum system uptime From a service and support standpoint IBM memory automatically assumes the IBM system warranty and IBM provides service and support worldwide The IBM System x3750 M4 supports DDR3 memory The server supports up to 48 DIMMs when four processors are installed with 12 DIMMs for each processor There are 24 DIMM sockets for processors 1 and 2 on the system board The remaining DIMM sockets for process
27. aded applications Intelligent and adaptive system performance with Intel Turbo Boost Technology 2 0 allows processor cores to run at maximum speeds during peak workloads by temporarily going beyond processor TDP Intel Hyper Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core up to two threads per core Intel Virtualization Technology integrates hardware level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads 48 Load Reduced DIMMs LRDIMMs of 1866 MHz DDR3 ECC memory provide speed high availability and a memory capacity of up to 1 5 TB The use of IBM eXFlash solid state drives SSDs instead of or along with traditional spinning drives HDDs can improve I O performance An SSD can support up to 100 times more I O operations per second IOPS than a typical HDD Up to 16 HDDs or 32 eXFlash SSDs together with an optical drive at the same time provide a flexible and scalable all in one platform to meet your increasing demands The server offers a SAS switch backplane option to allow up to 16x 2 5 inch drives to attach to a single controller The 5 3 PCI Express socket design of the server allows you to pay for PCle capabilities as needed The server has a dedicated flexible mezzanine LOM slot offering a variety of 10 GbE or Gigabit Ethernet adapters that do not occupy one of the 8 st
28. anagement Remote presence support is standard e The integrated industry standard Unified Extensible Firmware Interface UEFI enables improved setup configuration and updates and simplifies error handling e Integrated Trusted Platform Module TPM 1 2 support enables advanced cryptographic functionality such as digital signatures and remote attestation e Industry standard Advanced Encryption Standard AES NI support for faster stronger encryption IBM System x3750 M4 E5 4600 v2 3 IBM Systems Director is included for proactive systems management It offers comprehensive systems management tools that increases uptime reduces costs and improves productivity through advanced server management capabilities Intel Execute Disable Bit functionality can prevent certain classes of malicious buffer overflow attacks when combined with a supported operating system Intel Trusted Execution Technology provides enhanced security through hardware based resistance to malicious software attacks allowing an application to run in its own isolated space protected from all other software running on a system Energy efficiency The x3750 M4 offers the following energy efficiency features to save energy reduce operational costs and increase energy availability IBM System x3750 M4 E5 4600 v2 Energy efficient planar components help lower operational costs Highly efficient 750 W DC 900 W AC and 1400 W AC power supplies 80 PLUS Platinum
29. andard PCle slots The server offers PCI Express 3 0 I O expansion capabilities that improve the theoretical maximum bandwidth by almost 100 8 GTps per link using 128b 130b encoding compared to the previous generation of PCI Express 2 0 5 GTps per link using 8b 10b encoding With Intel Integrated I O Technology the PCI Express 3 0 controller is integrated into the Intel Xeon processor E5 family This integration reduces I O latency and increases overall system performance Availability and serviceability The x3750 M4 provides many features to simplify serviceability and increase system uptime e The server offers Chipkill memory mirroring and memory rank sparing for redundancy in the event of a memory failure e The server provides restart recovery for any failed processor If a failure of processor 1 occurs the server connects the Southbridge to processor 2 for reboot e Tool less cover removal provides easy access to upgrades and serviceable parts such as the processor memory and adapter cards e The server offers hot swap drives supporting RAID redundancy for data protection and greater system uptime e The server has up to two redundant hot swap power supplies and six hot swap dual rotor N N redundant fans to provide availability for business critical applications e The power source independent light path diagnostics panel and individual light path LEDs lead the technician to failed or failing components which simplif
30. ape drive bays None internal Use a supported external tape drive Network interfaces Dedicated mezzanine LOM adapter slot for a choice of 2 port 10 GbE RJ45 or SFP or 4 port 1 GbE controller One port can optionally be shared with the IMM2 management processor Standard models include Intel 1350 T4 ML2 Quad Port GbE Adapter 1350 based except model C2x which includes Broadcom NetXtreme II ML2 Dual Port 10GbaseT BCM57712 based PCI Expansion slots Up to eight slots five on the system board up to three on an optional riser card Slots 1 2 and 3 are physically x16 slots Alternative 2 slot riser with one x16 and one x8 slot also available The slots are as follows e Slot 1 PCle 3 0 x8 full height half length optional with riser card requires processor 2 Slot 2 PCle 3 0 x8 full height half length optional with riser card requires processor 2 Slot 3 PCle 3 0 x8 full height half length optional with riser card requires processor 2 Slot 4 PCle 3 0 x8 low profile requires processor 2 Slot 5 PCle 3 0 x8 low profile requires processor 2 Slot 6 PCle 3 0 x8 low profile Slot 7 PCle 3 0 x8 low profile Slot 8 PCle 3 0 x8 low profile IBM System x3750 M4 E5 4600 v2 Table 1 Standard specifications part 2 Components Specification Ports Front Two USB 2 0 and one DB 15 video on front Rear Two
31. at are supported by x3750 M4 and can be ordered through the System x sales channel The server might support other IBM disk systems that are not listed in this table See the IBM System Storage Interoperation Center for further information http www ibm com systems support storage ssic Table 23 External disk storage systems Part number Description 1746A2D IBM System Storage DS3512 Express Dual Controller Storage System 1746A2S IBM System Storage DS3512 Express Single Controller Storage System 1746A4D IBM System Storage DS3524 Express Dual Controller Storage System 1746A4S IBM System Storage DS3524 Express Single Controller Storage System 181420A IBM System Storage DS5020 Midrange Disk System For more information see the list of IBM Redbooks Product Guides in the System Storage category http www redbooks ibm com portals systemx Open amp page pg amp cat externalstorage IBM System x3750 M4 E5 4600 v2 31 External backup units The server supports the external backup attachment options that are listed in Table 24 Table 24 External backup options Part 1 Part number Description External tape expa nsion enclosures for internal tape drives 87651UX 1U Tape Drive Enclosure 8767HHX Half High Tape Drive Enclosure 87651NX 1U Tape Drive Enclosure with Nema 5 15P power cord 8767HNX Half High Tape Drive Enclosure with Nema 5 15P power cor
32. bm com common ssi cgi bin ssialias infotype dd amp subtype ca amp amp htmlfid 89 7 ENUS 114 037 IBM System x3750 M4 product page http www ibm com systems x hardware rack x3750m4 index html IBM System x3750 M4 Installation and Service Guide http ibm com support entry portal docdisplay Indocid MIGR 5090828 Integrated Management Module II User s Guide http ibm com support entry portal docdisplay Indocid MIGR 5086346 IBM ServerProven hardware compatibility page for the x3750 M4 http www ibm com systems info x86servers serverproven compat us xseries 8752 html IBM Redbooks Product Guides for IBM System x servers and options http www redbooks ibm com portals systemx Open amp page pgbycat Configuration and Options Guide http www ibm com systems xbc cog xREF IBM x86 Server Reference http www redbooks ibm com xref IBM System x Support Portal http ibm com support entry portal http ibm com support entry portal Downloads Hardware Systems System_x System_x3750_M4 IBM System Storage Interoperation Center SSIC http www ibm com systems support storage ssic IBM System x3750 M4 E5 4600 v2 41 Notices This information was developed for products and services offered in the U S A IBM may not offer the products services or features discussed in this document in other countries Consult your local IBM representative for information on the products and services currently available in your area Any reference
33. d Tape enclosure adapters with cables 44E8869 USB Enclosure Adapter Kit 40K2599 SAS Enclosure Adapter Kit Internal backup drives supported by external tape enclosures 43W8478 IBM Half High LTO Gen 3 SAS Tape Drive 44E8895 IBM Half High LTO Gen 4 SAS Tape Drive IBM System x3750 M4 E5 4600 v2 32 Table 24 External backup options Part 2 Part number Description External backup units 36251TY IBM RDX USB 3 0 Dock with 1TB Cartridge 362532Y IBM RDX USB 3 0 Dock with 320GB Cartridge 362550Y IBM RDX USB 3 0 Dock with 500GB Cartridge 3628L3X IBM Half High LTO Gen 3 External SAS Tape Drive with US power cord 3628L4X IBM Half High LTO Gen 4 External SAS Tape Drive with US power cord 3628L5X IBM Half High LTO Gen 5 External SAS Tape Drive with US power cord 3628N3X IBM Half High LTO Gen 3 External SAS Tape Drive without power cord 3628N4X IBM Half High LTO Gen 4 External SAS Tape Drive without power cord 3628N5X IBM Half High LTO Gen 5 External SAS Tape Drive without power cord 00D8924 IBM Half High LTO Ultrium Gen 6 Internal SAS Tape Drive The external tape drives listed can be ordered through System x sales channel The server might support other IBM tape drives that are not listed in this table See the IBM System Storage Interoperation Center for further infor
34. dapter 3 These modular adapters are not available through CTO or Special build The adapter cannot be shipped installed and instead must be shipped in its option box and configured at the final installation location For more information see http ibm com support entry portal docdisplay Indocid SERV IOMA For details about these adapters see the IBM Redbooks Product Guide BM High IOPS SSD PCle Adapters found at the following address http www redbooks ibm com abstracts tips0729 html Open IBM System x3750 M4 E5 4600 v2 23 Power supplies The server supports up to two redundant power supplies Standard models come with one or two 900 W power supplies model dependent see Table 2 1400 W AC and 750 W DC power supplies also available through CTO or Special Bid Installing a second power supply requires that the processor and memory expansion tray 88Y7365 or the power interposer card 88Y7367 be installed The power interposer card option enables redundancy power support when the processor and memory expansion tray is not installed If you do not have the processor and memory expansion tray installed and want to install two power supplies then the power interposer card must be installed Table 16 Power supplies Part number Feature Description Maximum Models code supported where used 44X4150 A54D IBM 1400W HE Redundant Power Supply for altitudes 2 gt
35. e 6 5 bels e Operating 6 6 bels IBM System x3750 M4 E5 4600 v2 26 Warranty options The IBM System x3750 M4 has a three year onsite warranty with 9x5 next business day terms IBM offers the warranty service upgrades through IBM ServicePac offerings described in this section The IBM ServicePac is a series of prepackaged warranty maintenance upgrades and post warranty maintenance agreements with a well defined scope of services including service hours response time term of service and service agreement terms and conditions IBM ServicePac offerings are country specific that is each country might have its own service types service levels response times and terms and conditions Not all covered types of ServicePac offerings might be available in a particular country For more information about the IBM ServicePac offerings that are available in your country see the IBM ServicePac Product Selector https www 304 ibm com sales gss download spst servicepac Table 18 explains the warranty service definitions in more detail Table 18 Warranty service definitions Term Description IBM onsite A service technician comes to the server s location for equipment repair repair IOR 24x7x2 hour A service technician is scheduled to arrive at your customer s location within two hours after remote problem determination is completed We provide service around the clock every day including IBM holidays 24x7x4
36. ext in Table 5 indicate that the IBM System x3750 M4 supports higher memory frequencies than the Intel processor specification In some instances this configuration also results larger memory capacity that the specification recommends e Tables cells highlighted with a gray background indicate when the specific combination of DIMM voltage and number of DIMMs per channel still allows the DIMMs to operate at rated speed Table 5 Maximum memory speeds DIMM specification RDIMM LRDIMM Ranks Single rank DIMMs Dual rank DIMMs Quad rank LRDIMMs Part numbers 00D5024 4 GB 00D5020 4 46W0672 16 GB 00D5048 46W0761 00D5036 8 GB GB 16 GB 32 GB 00D5032 8 GB Rated speed 1600 MHz 1866 MHz 1600 MHz 1866 MHz 1866 MHz Rated voltage 1 35 V 15V 1 35 V 15V 15V Operating voltage 1 35 V 1 5V 1 5V 1 35 V 1 5V 1 5V 1 5V Max qty supported 48 48 48 48 48 48 48 Max DIMM capacity 8 GB 8 GB 8 GB 16 GB 16 GB 16 GB 32 GB Max mem capacity 384 GB 384 GB 384 GB 768 GB 768 GB 768 GB 1 5 TB Max memory at 256 GB 256 GB 256 GB 512 GB 768 GB 512 GB 1 0 TB maximum speed Max operating speed MHz 1 DIMM per channel 1333 MHz 1600 MHz 1866 MHz 1333 MHz 1600 MHz 1866 MHz 1866 MHz 2 DIMMs per channel 1600 MHz 1600 MHz 1866 MHz 1600 MHz 1600 MHz 1866 MHz 1866 MHz 3 DIMMs per channel 1066 MHz 1333 MHz 1333 MHz 1066 MHz 1333 MHz 1333 MHz 1333 MHz
37. hour A service technician is scheduled to arrive at your customer s location within four hours after remote problem determination is completed We provide service around the clock every day including IBM holidays 9x5x4 hour A service technician is scheduled to arrive at your customer s location within four business hours after remote problem determination is completed We provide service from 8 00 a m to 5 00 p m in the customer s local time zone Monday through Friday excluding IBM holidays If the time is after 1 00 p m and it is determined that onsite service is required the customer can expect the service technician to arrive the morning of the following business day For noncritical service requests a service technician arrives by the end of the following business day 9x5 next A service technician is scheduled to arrive at your customer s location on the business day after we business day receive your call following remote problem determination We provide service from 8 00 a m to 5 00 p m in the customer s local time zone Monday through Friday excluding IBM holidays In general the types of IBM ServicePac offerings are as follows e Warranty and maintenance service upgrades e One 2 3 4 or 5 years of 9x5 or 24x7 service coverage e Onsite repair from next business day to 4 or 2 hours e One or two years of warranty extension e Remote technical support service
38. icantly Some measurements may have been made on development level systems and there is no guarantee that these measurements will be the same on generally available systems Furthermore some measurement may have been estimated through extrapolation Actual results may vary Users of this document should verify the applicable data for their specific environment COPYRIGHT LICENSE This information contains sample application programs in source language which illustrate programming techniques on various operating platforms You may copy modify and distribute these sample programs in any form without payment to IBM for the purposes of developing using marketing or distributing application programs conforming to the application programming interface for the operating platform for which the sample programs are written These examples have not been thoroughly tested under all conditions IBM therefore cannot guarantee or imply reliability serviceability or function of these programs Copyright International Business Machines Corporation 2014 All rights reserved Note to U S Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp IBM System x3750 M4 E5 4600 v2 42 This document was created or updated on March 31 2014 Send us your comments in one of the following ways e Use the online Contact us review form found at ibm com redbooks e Send your comments in an e ma
39. ies servicing speeds up problem resolution and helps improve system availability e The x3750 M4 provides error checking Predictive Failure Analysis PFA or both on the following components Alerts are generated in advance of a possible failure therefore increasing uptime Memory ECC correction Chipkill technology Microprocessor built in self test BIST and internal error checking PCle Bus parity checking SAS Bus Parity HDD and SSD drive CRC checking Diskette CRC checking USB CRC checking Over temperature detection Over under voltage detection Power supply error checking Fan failure detection Serial interface parity overrun and frame checking e Solid state drives SSDs offer more reliability than traditional mechanical HDDs for greater uptime e The built in Integrated Management Module Version II IMM2 continuously monitors system parameters triggers alerts and performs recovery actions in case of failures to minimize downtime e Built in diagnostics using Dynamic Systems Analysis DSA Preboot speed up troubleshooting tasks to reduce service time e Three year customer replaceable unit and onsite limited warranty 9 x 5 next business day Optional service upgrades are available Manageability and security Powerful systems management features simplify local and remote management of the x3750 M4 e The server includes an Integrated Management Module II IMM2 to monitor server availability and perform remote m
40. il to redbook us ibm com e Mail your comments to IBM Corporation International Technical Support Organization Dept HYTD Mail Station P099 2455 South Road Poughkeepsie NY 12601 5400 U S A This document is available online at http www ibm com redbooks abstracts tips1159 html Trademarks IBM the IBM logo and ibm com are trademarks or registered trademarks of International Business Machines Corporation in the United States other countries or both These and other IBM trademarked terms are marked on their first occurrence in this information with the appropriate symbol or indicating US registered or common law trademarks owned by IBM at the time this information was published Such trademarks may also be registered or common law trademarks in other countries A current list of IBM trademarks is available on the Web at http www ibm com legal copytrade shtml The following terms are trademarks of the International Business Machines Corporation in the United States other countries or both Calibrated Vectored Cooling Express Storage IBM Systems Director Active Energy Manager IBM Redbooks Redbooks logo ServerProven ServicePac System Storage System x The following terms are trademarks of other companies Intel Intel Xeon Intel logo Intel Inside logo and Intel Centrino logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other
41. improvements and or changes in the product s and or the program s described in this publication at any time without notice Any references in this information to non IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you Information concerning non IBM products was obtained from the suppliers of those products their published announcements or other publicly available sources IBM has not tested those products and cannot confirm the accuracy of performance compatibility or any other claims related to non IBM products Questions on the capabilities of non IBM products should be addressed to the suppliers of those products This information contains examples of data and reports used in daily business operations To illustrate them as completely as possible the examples include the names of individuals companies brands and products All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental Any performance data contained herein was determined in a controlled environment Therefore the results obtained in other operating environments may vary signif
42. ion Standard models Maximum code where used supported 88Y7371 A2A1 IBM x3750 M4 PCle 3 x8 riser B2x C1x 1 00D2009 A419 IBM x3750 M4 PCle 1x16 and 1x8 1 riser The three slots on the PCle 3 x8 riser are as follows e Slot 1 PCle 3 0 x8 x16 mechanical Full height half length requires processor 2 e Slot 2 PCle 3 0 x8 x16 mechanical Full height half length requires processor 2 e Slot 3 PCle 3 0 x8 x16 mechanical Full height half length requires processor 2 The two slots on the PCle 1x16 and 1x8 riser are as follows e Slot 1 PCle 3 0 x16 Full height half length requires processor 2 e Slot 2 PCle 3 0 x8 x16 mechanical Full height half length requires processor 2 e Slot 3 Not present The five standard slots on the system board are as follows Slot 4 PCle 3 0 x8 Low profile half length requires processor 2 Slot 5 PCle 3 0 x8 Low profile half length requires processor 2 Slot 6 PCle 3 0 x8 Low profile half length Slot 7 PCle 3 0 x8 Low profile half length Slot 8 PCle 3 0 x8 Low profile half length IBM System x3750 M4 E5 4600 v2 Network adapters The x3750 M4 machine type 8752 using Intel Xeon E5 4600 v2 processors offers a dedicated Mezzanine LOM slot for integrated networking In addition to the usual networking functions for the installed operating system this adapter also supports shared access to the IMM2 service processor if so enabled in UEFI Table 12 lists
43. ives IBM System x3750 M4 E5 4600 v2 17 Optical drives The server supports the optical drive options listed in Table 10 Table 10 Optical drives Part number Feature Description Maximum Models code supported where used 46M0902 4163 UltraSlim Enhanced SATA Multi Burner 1 The IBM UltraSlim Enhanced SATA Multi Burner 46M0902 supports the following media and speeds for reading CD ROM 24X CD DA DAE 20X CD R 24X CD RW 24X DVD ROM single layer 8X DVD ROM dual layer 8X DVD R 4 7 GB 6X DVD R DL 4X DVD R 6X DVD R DL 4X DVD RW 4 7 GB 4X DVD RW 4X DVD RAM 4 7 9 4 GB 4X The drive also supports the following media and speeds for writing CD R 24X CD RW 4X High Speed CD RW 10X Ultra Speed CD RW 16X Ultra Speed Plus CD RW 16X DVD R 8X DVD R DL 6X DVD R 8X DVD R DL 6X DVD RW 6X DVD RW 8X DVD RAM 5X IBM System x3750 M4 E5 4600 v2 I O expansion options The server supports up to eight PCle slots not including the mezzanine LOM slot Five slots are on the system board and three are through a riser card A riser card is standard on some models as shown in the table below It is optional on all other models The use of slots 1 5 require processor 2 to be installed Table 11 lists the ordering information for the riser cards Table 11 PCI riser card options Part number Feature Descript
44. mation For the latest information about the specific versions and service levels supported and any other prerequisites see the IBM ServerProven website http www ibm com systems info x86servers serverproven compat us nos matrix shtml For more information see the list of IBM Redbooks Product Guides in the Backup units category http www redbooks ibm com portals systemx Open amp page pg amp cat tape IBM System x3750 M4 E5 4600 v2 33 Top of rack Ethernet switches The server supports the top of rack Ethernet switches from IBM System Networking listed in Table 25 Table 25 IBM System Networking Top of rack switches Part number Description IBM System Networking 1 Gb top of rack switches 0446013 IBM System Networking RackSwitch G8000R 7309CFC IBM System Networking RackSwitch G8000F 7309CD8 IBM System Networking RackSwitch G8000DC 7309G52 IBM System Networking RackSwitch G8052R 730952F IBM System Networking RackSwitch G8052F 427348E IBM Ethernet Switch J48E 6630010 Juniper Networks EX2200 24 Port 6630011 Juniper Networks EX2200 24 Port with PoE 6630012 Juniper Networks EX2200 48 Port 6630013 Juniper Networks EX2200 48 Port with PoE IBM System Networking 10 Gb top of rack switches 7309DRX IBM System Networking RackSwitch G8264CS Rear to Front 7309DFX IBM System
45. number Description Maximum quantity supported per one enclosure EXP2524 Hot Swap SAS 2 5 in Hard Drives 49Y1896 146 GB 15 K 6 Gb SAS 2 5 in HDD 24 49Y1895 300 GB 10 K 6 Gb SAS 2 5 in HDD 24 81Y9596 600 GB 10 K 6 Gb SAS 2 5 in HDD 24 49Y1898 500 GB 7 200 RPM 6 Gb SAS NL 2 5 in HDD 24 EXP2524 Hot Swap SAS 2 5 in Solid State Drives 81Y9956 200 GB 2 5 in SAS SSD 24 81Y9960 400 GB 2 5 in SAS SSD 24 The RAID controllers listed in Table 21 are supported with external expansion enclosures Table 21 RAID controller and options for external storage expansion enclosures Part number Feature Description Maximum code supported 81Y4478 A1WX ServeRAID M5120 SAS SATA Controller 4 81Y4487 A1J4 ServeRAID M5100 Series 512MB Flash RAID 5 Upgrade 1 per one M5120 81Y4559 A1WY ServeRAID M5100 Series 1GB Flash RAID 5 Upgrade 1 per one M5120 81Y4546 A1X3 ServeRAID M5100 Series RAID 6 Upgrade 1 per server 90Y4273 A2MC ServeRAID M5100 Series SSD Performance Accelerator 1 per server 90Y4318 A2MD ServeRAID M5100 Series SSD Caching Enabler 1 per server Each M5120 controller must have either the 512MB Flash RAID 5 or the 1GB Flash RAID 5 upgrade installed The ServeRAID M5120 SAS SATA Controller has the following specifications Eight external 6 Gbps SAS SATA ports T
46. oft Windows Server 2008 R2 with SP1 Red Hat Enterprise Linux 6 Server x64 Edition SUSE Linux Enterprise Server 11 for AMD64 EM64T SP3 SUSE Linux Enterprise Server 11 with Xen for AMD64 EM64T SP3 VMware vSphere 5 5 ESXi VMware vSphere 5 1 ESXi Update 1 For the latest information about the specific versions and service levels supported and any other prerequisites see the IBM ServerProven website found at the following address http www ibm com systems info x86servers serverproven compat us nos matrix shtml IBM System x3750 M4 E5 4600 v2 25 Physical and electrical specifications Dimensions and weight Width 446 mm 17 5 in Depth 734 mm 28 9 in Height 87 mm 3 4 in Approximate weight fully configured 31 1 kg 68 5 Ib Supported environment e Air temperature e 5 40 C 41 104 F at 0 3048 m 10 000 ft ASHRAE A3 compliant Humidity 8 80 Electrical 100 127 nominal V AC 50 Hz or 60 Hz and System 20 A 10 A per power supply 200 208 nominal V AC 50 Hz or 60 Hz and System 10 A 200 240 nominal V AC 50 Hz or 60 Hz and System 9 A Minimum configuration 0 20 kVA one power supply Minimum configuration 0 26 kVA two power supplies Typical configuration 1 12 kVA two power supplies Maximum configuration 2 16 kVA two power supplies BTU output e Minimum configuration 648 BTU hr 190 watts e Maximum configuration 7 336 BTU hr 2150 watts e Noise level e Idl
47. onitor kits listed in Table 29 Table 29 Rack options Part number Feature code Description Monitor kits and keyboard trays 17238BX 1723HC1 fc ASEK IBM 1U 18 5 Standard Console 17238EX 1723HC1 fc ASEL IBM 1U 18 5 Enhanced Media Console 172317X 1723HC1 fc 0051 1U 17in Flat Panel Console Kit 172319X 1723HC1 fc 0052 1U 19in Flat Panel Console Kit Console switches 3858D3X 3858HC1 fc A4X1 Avocent Universal Management Gateway 6000 for IBM 1754D2X 1754HC2 fc 6695 IBM Global 4x2x32 Console Manager GCM32 1754D1X 1754HC1 fc 6694 IBM Global 2x2x16 Console Manager GCM16 1754A2X 1754HC4 fc 0726 IBM Local 2x16 Console Manager LCM16 1754A1X 1754HC3 fc 0725 IBM Local 1x8 Console Manager LCM8 Console cables 00AK142 A4X4 UM KVM Module VGA SD Dual RJ45 43V6147 3757 IBM Single Cable USB Conversion Option UCO 39M2895 3756 IBM USB Conversion Option 4 Pack UCO 46M5383 5341 IBM Virtual Media Conversion Option Gen2 VCO2 46M5382 5340 IBM Serial Conversion Option SCO For more information see the list of IBM Redbooks Product Guides in the Rack cabinets and options category http www redbooks ibm com portals systemx Open amp page pg amp cat rack IBM System x3750 M4 E5 4600 v2 39 IBM Global Financing IBM Global Financing can help you obtain the IT sol
48. ors 3 and 4 are on the processor and memory expansion tray Each processor has four memory channels and there are three DIMMs per channel IBM System x3750 M4 E5 4600 v2 10 The x3750 M4 memory system has been carefully tuned so that the server supports higher memory frequencies than the Intel processor specification You can for example use low voltage DIMMs but still operate them at the rated speed Table 4 lists the memory options that are available for the x3750 M4 server Table 4 Memory options Part Feature Description Maximum Models number code supported where used RDIMMs 1866 MHz 00D5048 A3QL 16GB 1x16GB 2Rx4 1 5V PC3 14900 CL13 ECC DDR3 48 12 per 1866MHz LP RDIMM processor 00D5032 A3QG 8GB 1x8GB 1Rx4 1 5V PC3 14900 CL13 ECC DDR3 48 12 per 8752 A1x 1866MHz LP RDIMM processor 00D5020 A3QD 4GB 1x4GB 1Rx4 1 5V PC3 14900 CL13 ECC DDR3 48 12 per 1866MHz LP RDIMM processor RDIMMs 1600 MHz 46W0672 A3QM 16GB 1x16GB 2Rx4 1 35V PC3L 12800 CL11 ECC DDR3 48 12 per l 1600MHz LP RDIMM processor 00D5036 A3QH 8GB 1x8GB 1Rx4 1 35V PC3L 12800 CL11 ECC DDR3 48 12 per All other 1600MHz LP RDIMM processor 8752 models 00D5024 A3QE 4GB 1x4GB 1Rx4 1 35V PC3L 12800 CL11 ECC DDR3 48 12 per 1600MHz LP RDIMM processor LRDIMMs
49. s e One or three years with 24x7 coverage severity 1 or 9x5 next business day for all other severities e Installation and start up support for System x servers Remote technical support for System x servers e Software support Support Line e Microsoft or Linux software e VMware e IBM Systems Director IBM System x3750 M4 E5 4600 v2 27 Regulatory compliance The server conforms to the following standards ASHRAE A3 FCC Verified to comply with Part 15 of the FCC Rules Class A Canada ICES 003 issue 4 Class A UL IEC 60950 1 CSA C22 2 No 60950 1 NOM 019 Argentina IEC60950 1 Japan VCCI Class A Australia New Zealand AS NZS CISPR 22 Class A IEC 60950 1 CB Certificate and CB Test Report China CCC GB4943 GB9254 Class A GB17625 1 Taiwan BSMI CNS13438 Class A CNS14336 1 Korea KN22 Class A KN24 Russia GOST ME01 IEC 60950 1 GOST R 51318 22 GOST R 51318 24 GOST R 51317 3 2 and GOST R 51317 3 3 IEC 60950 1 CB Certificate and CB Test Report CE Mark EN55022 Class A EN60950 1 EN55024 EN61000 3 2 and EN61000 3 3 CISPR 22 Class A TUV GS EN60950 1 IEC60950 1 EK1 ITB2000 RoHS compliance Directive 2002 95 EC IBM System x3750 M4 E5 4600 v2 28 External disk storage expansion The external disk storage expansion enclosures listed Table 19 are available Table 19 External storage expansion enclosures Part number Description Maximum quantity supported per one adapter
50. sor memory speed t Models C1x and C2x include the ServeRAID M5200 Series 1GB Flash RAID 5 Upgrade part number 47C8660 which is a 1 GB flash backed cache with support for RAID 5 See the Standards specifications section for information about the standard features of the server IBM System x3750 M4 E5 4600 v2 Processor options The x3750 M4 supports the processor options listed in Table 3 The server supports up to four processors Two processors are installed in sockets on the system board Processors 3 and 4 are installed on the processor and memory expansion tray Most models with the exception of A2x as listed in Table 2 have the expansion tray installed as standard For model A2x order part number 88Y7365 for the processor and memory expansion tray The following processor quantities are supported e One processor installed in socket 1 e Two processors installed in sockets 1 and 2 e Four processors installed in all four sockets Table 3 also shows which server models have each processor standard If there is no corresponding where used model for a particular processor this processor is only available through CTO Table 3 Processor options Partnumber Feature code Description Models where used 88Y7365 A29Z IBM System x3750 M4 processor and memory expansion tray A except x 00D1948 A43K A43
51. the supported ML2 adapters that are installed in this slot Only one adapter is supported Table 12 Mezzanine LOM network adapters Partnumber Feature Description Maximum code supported 10 Gb Ethernet 00D2026 A40S Broadcom NetXtreme I ML2 Dual Port 10GbaseT for IBM System x 1 00D2028 A40T Broadcom NetXtreme II ML2 Dual Port 1OGbE SFP for IBM System x 1 00D1996 A40Q Emulex VFA5 ML2 Dual Port 10GbE SFP Adapter for IBM System x 1 00D8544 A4NZ Emulex VFA5 ML2 FCoE iSCSI License for IBM System x FoD 1 FCoE iSCSI upgrade for 00D1996 00D1994 A40P Intel X540 ML2 Dual Port 10GbaseT Adapter for IBM System x 1 1 Gb Ethernet 00D1998 A40R Intel 1350 T4 ML2 Quad Port GbE Adapter for IBM System x 1 These ML2 adapters occupy the same dedicated slot and are mutually exclusive IBM System x3750 M4 E5 4600 v2 20 Table 13 lists additional supported network adapters that can be installed in the eight regular PCle slots Table 13 Network adapters Part number Feature Description Maximum code supported 40 Gb Ethernet 00D9550 A3PN Mellanox ConnectX 3 40GbE FDR IB VPI Adapter for IBM System x 8
52. ts the RAID controllers and SAS HBAs used for the internal disk storage of the x3750 M4 server Table 7 RAID controllers for internal storage Part number Feature code Description Maximum Models supported where used None A3QA SeveRAID M5210e SAS SATA Controller 1 integrated All 4609110 A3YZ ServeRAID M5210 SAS SATA Controller 3 47C8675 A3YY N2215 SAS SATA HBA for IBM System x 3 The integrated ServeRAID M5210e SAS SATA controller in a chip on the system board for machine type 8752 It has the following specifications Note The drives and backplanes currently supported in the x3750 M4 operate at 6 Gbps speeds so the LSI SAS3108 RAID on Chip ROC controller Eight internal SAS SATA ports Two internal x4 HD Mini SAS connectors SFF 8643 PCI Express 3 0 x8 host interface Support for RAID 0 1 and 10 standard Support for RAID 5 50 6 and 60 with optional upgrades Optional onboard data cache 1 GB no battery backup or 1 or 2 GB with flash backup Optional support for self encrypting drives SEDs with MegaRAID SafeStore M5210e will also operate at 6 Gbps For more information see the list of IBM Redbooks Product Guides in the RAID adapters category http www redbooks ibm com portals systemx Open amp page pg amp cat raid Note The supported adapters for internal storage need to be installed in slots 1 2 and 3 because of cable
53. ution you need while preserving funding for other strategic investments and optimizing cash flow Our Fair Market Value FMV lease helps ensure that you have the latest IBM technology and with our mid lease upgrade capability you can increase the capacity of the system with little to no change in monthly payments At the end of the lease take advantage of our flexible end of lease options to fit your changing business needs Only IBM Global Financing has the breadth and depth of offerings longevity proven success and global reach to help you develop a robust financing and asset management strategy that provides you the opportunity to use new technologies and turn your ambitious vision into a tangible solution Here are some other reasons why working with us makes solid financial sense e Expand your purchasing power Affordable monthly payments allow you to change the technology acquisition discussion from what can afford right now to what solution is really right for my business IBM Global Financing allows you to expand your purchase power to get you the right solution e Accelerate your project s cash flow break even point Acquire your IBM technology today and begin to realize its benefits now An FMV lease can help you get the solution you need now with low monthly payments that better align up front costs with the anticipated return on investment ROI from the technology e Easy to acquire with affordable rates We offer
54. we Redbooks IBM System x3750 M4 E5 4600 v2 IBM Redbooks Product Guide The IBM System x3750 M4 is a 4 socket server featuring a streamlined design optimized for price and performance with best in class flexibility and expandability Models of the x3750 M4 machine type 8752 are powered with Intel Xeon E5 4600 v2 processors up to 12 cores each for an entry level 4 socket solution The x3750 M4 provides maximum storage density with flexible PCI and 10 Gb Ethernet networking options in a 2U form factor Suggested uses High performance computing HPC workloads with floating point computations and small to medium databases requiring fast I O applications that require 4 socket performance without needing the scalability that the IBM X6 systems provide A e AAAA cn Figure 1 The IBM System x3750 M4 Did you know With a dense 2U design the IBM System x3750 M4 provides advanced features and capabilities These include support for up to four sockets and 48 DIMMs mix and match internal storage up to 16 HDDs or 32 eXFlash solid state drives SSDs six hot swap dual rotor fans and two power supplies A Mezzanine LOM socket provides a choice of 1 Gigabit Ethernet GbE or 10 GbE networking options Predictive Failure Analysis and light path diagnostics proactively monitor the system s sub components and provide advanced warning on power supplies fans drives processors and memory IBM System x3750 M4 E5 4
55. wo external x4 mini SAS connectors SFF 8088 Supports RAID levels 0 1 and 10 Supports RAID levels 5 and 50 with the required M5100 Series RAID 5 upgrades Supports RAID 6 and 60 with the optional M5100 Series RAID 6 Upgrade Supports 512 MB battery backed cache or 512 MB or 1 GB flash backed cache 6 Gbps throughput per port PCle 3 0 x8 host interface Based on the LSI SAS2208 6 Gbps ROC controller Supports connectivity to the EXP2512 and EXP2524 storage expansion enclosures For more information see the IBM Redbooks Product Guide ServeRAID M5120 SAS SATA Controller for IBM System x TIPS0858 http www redbooks ibm com abstracts tips0858 html Open IBM System x3750 M4 E5 4600 v2 The external SAS cables listed in the following table are supported with external expansion enclosures and RAID controllers Table 22 External SAS cables for external storage expansion enclosures Partnumber Feature Description Maximum quantity code supported per enclosure 39R6531 3707 IBM 3m SAS Cable 1 39R6529 3708 IBM 1m SAS Cable 1 The EXP3000 and EX2500 series can be chained with each other In such a case one cable is used to connect first EXP25xx or EXP3000 to the RAID controller and every consecutive EXP unit is connected to the previous one by one cable External disk storage systems Table 23 lists the external storage systems th
56. x 1x E5 4603 v2 4C 2 2GHz 1x 8 GB M5210e Open Open 5 8 4x 1GbE 1x 900W 10MB 1333MHz 95W 1333 MHz 8752 A3x 2x E5 4607 v2 6C 2 6GHz 2x 8 GB M5210e 4x 2 5 Open 5 8 4x 1GbE 1x 900W 15MB 1333MHz 95W 1333 MHz 16 max 8752 B1x 2x E5 4610 v2 8C 2 3GHz 2x 8 GB M5210e 4x 2 5 Open 5 8 4x 1GbE 1x 900W 16MB 1600MHz 95W 1600 MHz 16 max 8752 B2x 2x E5 4620 v2 8C 2 6GHz 2x 8 GB M5210e 8x 1 8 Open 8 8 4x 1GbE 1x 900W 20MB 1600MHz 95W 1600 MHz 32 max 8752 C1x 2x E5 4640 v2 10C 2 2GHz 2x8 GB M5210e 4x 2 5 Open 8 8 4x 1GbE 1x 900W 20MB 1866MHz 95W 1600 MHz 1GB F R5 t 16 max 8752 C2x 2x E5 4650 v2 10C 2 4GHz 2x8 GB M5210e 4x 2 5 Open 5 8 2x 10GbE 1x 900W 25MB 1866MHz 95W 1600 MHz 1GB F R5 t 16 max Processor detail Processor quantity and model cores core speed L3 cache memory speed and power consumption All models except for 8752 A2x include the processor and memory expansion tray containing sockets for processors 3 and 4 and 24 DIMMs For model A2x order part number 88Y7365 Model 8752 C2x includes the Broadcom NetXtreme II ML2 Dual Port 10GbaseT adapter 00D2026 All other models include the Intel 1350 T4 ML2 Quad Port GbE Adapter 00D1998 For these models the standard DIMM is rated at 1600 MHz but operates at up to 1333 MHz to match the proces
57. xpander backplane with the supplied cables and then the SAS expander backplane is connected to the single RAID controller with two cables All backplane options include the necessary cables See the BM System x3750 M4 Installation and Service Guide for a description of all supported backplane combinations Standard models all models except A2x ship with at least one backplane see Table 2 for details Table 6 shows the backplane options that are available for a x3750 M4 server Table 6 Internal storage expansion options Part number Feature Name Maximum code supported 00D2020 A2A3 IBM 4x 2 5 in HS SAS HDD Backplane 4 00D2022 A2A4 IBM 8x 2 5 in HS SAS HDD Backplane 2 00D2011 A2A2 IBM 8x 2 5 in HS SAS HDD Backplane 1 with RAID expansion SAS expander 00D2024 9281 IBM eXFlash 8x 1 8 in HS SAS SSD Backplane 4 When a server is ordered via CTO only one 4 drive backplane can be selected If the order has more than 4 drive bays 8 drive backplanes will be selected instead Only one backplane with SAS expander 00D2011 can be installed in a server and can be used connected to a single 8 drive backplane 00D2022 a single 4 drive backplane 00D2020 or two 4 drive backplanes 00D2020 The SAS expander backplane cannot be used with the eXFlash backplane IBM System x3750 M4 E5 4600 v2 13 Controllers for internal storage Table 7 lis

Download Pdf Manuals

image

Related Search

Related Contents

Samsung Цветной лазерный принтер Samsung CLX-3185 Инструкция по использованию    Loyers et CopropriÉtÉ  Allegato 1 - Schema di contratto con allegati pdf  Krautkramer Serie CL 5  istisbl3fc410rim 0.3.vp  ÄKTA avant Operating Instructions  DeLOCK 46207 flat panel wall mount    Juin 2010 - Bienvenue à Monchecourt  