Home

Eaton Power-Sure 700

image

Contents

1. 00 Hz 40 dBA per decade Less than 1 added 1 cycle typical 1 5 cycle maximum 200 for 10 seconds 1000 for 1 cycle Automatic electronic shutdown if output voltage exceeds 10 for 6 seconds adjustable Normal mode noise attenuation Total harmonic distortion Correction time Overload rating Overvoltage protection ENVIRONMENTS Indicator lights Three green lights indicate regulated voltage on each phase A fourth red light indicates an overtemperature condition Audible noise Less than 50 dBA 1 meter depending on size Operating temperature 10 C to 40 C Altitude Up to 10 000 ft STANDARDS Safety agency UL 1012 CSA FCC Cat A Meets ANSI IEEE Standard C62 41 1991 Warranty One year Surge suppression Due to continuing product improvement programs specifications are subject to change without notice POWER SURE 700 POWER CONDITIONERS THREE PHASE Output Cabinet size Part Number kVA Input voltage Output voltage distribution H x W x D in Weight Ib T__ 010k _ 10 208 240 480 208Y 120 Hardwire 30 0 x 21 5 x 29 0 440 T_ _ 015k _ 15 208 240 480 208Y 120 Hardwire 30 0 x 21 5 x 29 0 520 T_ _ 025k _ 25 208 240 480 600 208Y 120 Hardwire 44 0 x 21 5 x 29 0 700 T_ _ 030k _ 30 208 240 480 600 208Y 120 Hardwire 44 0 x 21 5 x 29 0 720 T_ _ 045k _ 45 208 240 480 600 208Y 120 Hardwire 44 0 x 45 0 x 29 0 950 T__ 050k _ 50 208 240 480 600 208 120 480 277 Hardwire 44 0 x 45 0 x 29 0 970 T_ _ 075k _ 75 480 600
2. 208 120 480 277 Hardwire 44 0 x 45 0 x 29 0 1100 T__ 100k _ 100 480 600 208 120 480 277 Hardwire 44 0 x 45 0 x 29 0 1660 T_ _ 125k _ 125 480 600 208 120 480 277 Hardwire 44 0 x 45 0 x 29 0 1980 T_ _ 150k _ 150 480 600 208 120 480 277 Hardwire 44 0 x 45 0 x 29 0 2200 T_ _ 225k _ 225 480 600 208 120 480 277 Hardwire 77 0 x 56 0 x 41 5 3300 T_ _ 300k _ 300 480 600 208 120 480 277 Hardwire 77 0 x 56 0 x 41 5 4000 Part T 010k ____ Frequency rating e 75 300 kVA are available with 480 600V input only requires 6 60 Hz 5 50 Hz an additional auto transformer for lower input voltage e Listings UL listed CSA Certified except for 600V no UL CSA on 600V units e For output distribution option call factory e K factor rated units available on request w W Input options Output options B 208 Vac C 240 Vac L 208 120 Vac wye output D 480 Vac E 600 Vac N 480 277 Vac wye output UNITED STATES CANADA 8609 Six Forks Road Ontario 416 798 0112 Raleigh NC 27615 U S A Toll Free 1 800 356 5794 EUROPE MIDDLE EAST AFRICA Denmark 45 3686 7910 Finland 358 94 52 661 France 33 1 6012 7400 Germany 49 0 7841 604 0 Italy 39 02 66 04 05 40 Norway 47 23 03 65 50 Portugal 55 11 3616 8500 Sweden 46 8 598 940 00 United Kingdom 44 1753 608 700 ASIA PACIFIC Australia NZ 61 2 9693 9366 China 86 21 6361 5599 HK Korea Taiwan 852 2745 6682 India 91 11 4223 2300 Singapore SEA 65 6829 8888 LATIN AMERICA Brazil 55 11 3616 8500
3. Caribbean 1 949 452 9610 M xico amp Central America 52 55 9000 5252 South Cone 54 11 4343 6323 www eaton com powerquality Eaton Power Sure and PowerChain Management are tradenames trademarks and or service marks of Eaton Corporation All other trademarks are the property of their respective owners a o e s 2009 Eaton Corporation E To All Rights Reserved mz Printed in USA PowarChain Powering Business Worldwid POWE RTINA Management g Business Worldwide gemen July 2009
4. Pulsar series Eaton Power Sure 700 Intelligent protection for transmitters amp industrial controls 10 300 kVA Features e Processor controlled voltage regulation e Tight output voltage regulation e Zero current switching e Wide input regulation range e Triple shielded computer grade transformer e Highly efficient 97 percent typical e High inrush capability e Transient protection and high frequency filter e Over under voltage protection optional e Includes input circuit breaker e Manual bypass switch optional ELN Powering Business Worldwide The Eaton Power Sure 700 three phase power line conditioning system provides exceptional system reliability that can be attributed to Eaton s processor controlled zero current cross tap switching technology The Power Sure 700 combines voltage regulation with a transformer and filter to remove transients and noise The combined effect is a regulating and shielded isolation transformer system that solves 99 percent of the electrical disturbance problems including electrical brownouts sags surges transients and other electrical disturbances This state of the art power conditioner also provides the protection efficiency and reliability that are critical to every application with sensitive equipment Options e RRM2020 Regulation Range Monitor has above below and normal LED indicator lights that indicate when the input is beyond the regulation range o
5. r within the range e RBS202x Integral Manual Rotary Maintenance Bypass Switch Specific models numbers include RBS2020 10 to 15 kVA units RBS2021 25 to 30 kVA units RBS2022 45 to 125 kVA units RBS2023 150 kVA units RBS2024 225 to 300 kVA units e REP2020 Remote Emergency Power Off Option REPO a remotely mounted pushbutton is provided with 50 feet of cable The ShuntTrip option STC2020 is required with this option e STC2020 Shunt Trip for Main Circuit Breaker Option e VOV2020 Under Over Voltage Shutdown Option if the output exceeds preset values the unit output will shut off electronically amp illuminate a diagnostic light e PS02020 Under Over Voltage Shutdown with Loss of Power Shut Off instead of disabling the output this option will shunt trip the main circuit breaker if the output voltage exceeds preset values The ShuntTrip option STC2020 is required with this option e ERR1040 Extended Regulation Range Option provides 10 to 40 input regulation range for intermittent duty only Output regulation is 5 to 6 from nominal with this option TECHNICAL SPECIFICATIONS Technology Tap changer 10 to 20 3 typical 47 53 Hz for 50 Hz models 57 73 Hz for 60 Hz models 97 typical 95 minimum Input voltage range Output voltage range Input frequency range Efficiency Load power factor 0 6 leading to 0 6 lagging Common mode noise attenuation 140 dB 3 dB 10