Home
Cisco 16GB SD
Contents
1. B2 B1 A2 A1 G1 G2 H1 H2 J A1 Q JO JUOIS F2 F1 E2 E1 331707 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 51 SUPPLEMENTAL MATERIAL Memory Population Rules When considering the memory configuration of your server you should consider the following items m Each channel has two DIMM slots for example channel A slots Al and A2 Achannel can operate with one or two DIMMs installed If a channel has only one DIMM populate slot 1 first the blue slot m When both CPUs are installed populate the DIMM slots of each CPU identically Fill blue slots in the channels first Al E1 B1 F1 C1 G1 D1 HI Fill black slots in the channels second A2 E2 B2 F2 C2 G2 D
2. Cordset rating 10 A 250 V Z S Length 8 ft 2 in 2 5 m Connector IEC 60320 C15 Power Cord 250VAC 10A BS1363 Plug 13 A fuse UK 7 oli Cordset rating 10 A 250 V 500 V MAX f7 NI Ot Length 2500mm Connector I Plug EL 210 EN 60320 C15 s BS 1363A 13 AMP fuse Power Cord 125VAC 13A NEMA 5 15 Plug North America Power Cord 3PIN J apan Image not available Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 33 CONFIGURING the SERVER STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM The reversible cable management arm mounts on either the right or left slide rails at the rear of the server and is used for cable management Use Table 14 to order a cable management arm Table 14 Cable Management Arm Product ID PID PID Description UCSC CMA1 Cable Management Arm for C220 rack servers For more information about the cable management arm see the Cisco UCS C220 M3 Installation and Service Guide at this URL http www cisco com en US docs unified computing ucs c hw C220 install C220 pdf NOTE All UCS C220 M3 servers ship with a tool less rail kit 34 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 11 ORDER A TRUS
3. 38 STEP 15 SELECT OPERATING SYSTEM MEDIA KIT 0 2020 aa 40 STEP 16 SELECT OPTIONAL VALUE ADDED SOFTWARE 0000 cues 41 STEP 17 SELECT SERVICE and SUPPORT LEVEL 0 0 0 a ee 42 OPTIONAL STEP ORDER RACK S 2 00 ce eee ene eee eens 47 OPTIONAL STEP ORDER PDU 1 cece ee es 48 SUPPLEMENTAL MATERIAL 0 00 cee eee eee eee anyo y 49 CHASSIS ka das oe chen ho hee ee ee ee ee eee Pa AG ee 49 CPUS and DIMMS is a waw a wa Gedo eG bo oS PAD GR AREA AK GRAN NAG MANNA GA 50 PN SCO Layout nseri BNMAKAR AA NA KA MANG ROPER OTE a ANAN AHA 50 Memory Population Rules a 52 Recommended Memory Configuration ee 53 Supported DIMM Populations 0 aa 54 Low Voltage DIMM Considerations a 55 no NBSA ngs oe thes eh abeee este enGa eh Gtesn AT 56 RAID Option ROM OPROM Settings 0 0 ce ee 58 Upgrade and Servicing Related Parts ees 59 Drive Blanking PanelS 0a 60 Adding an Additional CPU with CPU heat sink 00 60 Motherboard Lithium Battery 0 a 60 CPU Removal and Installation pick n place Tool Set 60 Thermal Grease with syringe applicator for CPU to Heatsink Seal 61 Air Baffle Replacement Kit 2 2 0 0 es 61 CPU Heat Sink Cleaning Kit 2 0 ee 61 RACKS 440 0 ue O44 oo ee AA ee ee oe eS 62 POUS fa eee edd the eee RE ea ea a ee Gea Ok AT 64 KVM CABLE 00 fed o4eu ee ee CR Aad eee
4. CONFIGURING the SERVER STEP 5 SELECT HARD DISK DRIVES HDDs or SOLID STATE DRIVES SSDs The standard disk drive features are m 2 5 inch small form factor m Hot pluggable m Sled mounted Select Drives The available drives are listed in Table 8 Table 8 Available Hot Pluggable Sled Mounted HDDs and SSDs Product ID PID HDDs A03 D1TBSATA UCS HDD900GI2F 106 A03 D600GA2 A03 D500GC3 UCS HDD300GI2F105 A03 D300GA2 A03 D146GC2 SSDs UCS SD400G0KA2 G UCS SD300G0KA2 E UCS SD200G0KA2 E UCS SD100G0KA2 G UCS SD100GOKA2 E PID Description i Capacity 1TB SATA 7 2K RPM SFF HDD SATA 1TB 900 GB 6Gb SAS 10K RPM SFF HDD SAS 900 GB 600 GB 6Gb SAS 10K RPM SFF HDD SAS 600 GB 500 GB SATA 7 2K RPM SFF HDD SATA 500 GB 300 GB 6Gb SAS 15K RPM SFF HDD SAS 300 GB 300 GB 6Gb SAS 10K RPM SFF HDD SAS 300 GB 146 GB 6Gb SAS 15K RPM SFF HDD SAS 146 GB 400 GB SATA 2 5 Enterprise Value SSD SATA 400 GB 300 GB SATA 2 5 Enterprise Performance SATA SSD SATA 300 GB 200 GB SATA 2 5 Enterprise Performance SATA SSD SATA 200 GB 100 GB SATA 2 5 Enterprise Value SSD SATA 100 GB 100 GB SATA 2 5 Enterprise Performance SATA SSD SATA 100 GB NOTE When creating a RAID volume follow these guidelines SS m Use the same capacity for each drive in the volume m Use either all SAS drives or all SATA drives m Use either all HDDs or all SSDs Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 23 CONFIGURING the
5. Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 41 CONFIGURING the SERVER STEP 17 SELECT SERVICE and SUPPORT LEVEL A variety of service options are available as described in this section Unified Computing Warranty No Contract If you have noncritical implementations and choose to have no service contract the following coverage is supplied m Three year parts coverage Next business day NBD onsite parts replacement eight hours a day five days a week 90 day software warranty on media Ongoing downloads of BIOS drivers and firmware updates UCSM updates for systems with Unified Computing System Manager These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications release notes and industry standards SMARTnet for UCS For support of the entire Unified Computing System Cisco offers the Cisco SMARTnet for UCS Service This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment Access to Cisco Technical Assistance Center TAC is provided around the clock from anywhere in the world For UCS blade servers there is Smart Call Home which provides proactive embedded diagnostics and real time alerts For systems that include Unified Computing System Manager the support service includes downloads of UCSM upgrades The Cisco
6. will be installed in the full height slot RAID controllers are always installed in the Caveats half height slot For 1 CPU systems Only the full height PCle slot slot 1 is supported Neither PCle slot 2 nor the mezzanine card slot are supported Only asingle VIC card the Cisco VIC 1225 PCle card is supported and it must be installed in slot 1 the full height slot For 2 CPU systems Both PCle slots slots 1 and 2 and the mezzanine card slot are supported Only a single VIC card the half height Cisco VIC 1225 PCle card is supported and it must be installed in slot 1 the full height slot All PCle cards will fit in either slot Other considerations for the Cisco VIC 1225 Supports 10G SFP optical and copper twinax connections The server supports installation of one Cisco VIC 1225 card and it is supported only in PCle slot 1 Requires that the server has CIMC firmware version 1 4 6 or later installed There is a heartbeat LED on the top of the card that indicates when firmware Is active To use this card for UCS integration Cisco UCS Manager mode with Cisco UCS Manager 2 1 0 or later the minimum card firmware and uboot image level is 2 1 0 306 m To help ensure that your operating system is compatible with the card you have selected 26 check the Hardware Compatibility List at this URL http www cisco com en US products ps10477 prod technical reference _list html Cisc
7. 10 m 2008M 8i Mezzanine Cards 6 Gbs two versions e Cisco UCSC RAID SAS 2008M 8i Mezzanine Card supporting up to 8 SAS SATA drives supporting RAID 0 1 5 10 and 50 SAS and SATA drives can be mixed This card has a product ID PID of UCSC RAID 11 C220 e Cisco UCSC RAID SAS 2008M 8i Mezzanine Card supporting up to eight SAS SATA drives supporting RAID O 1 and 10 This card has a product ID PID of UCSC RAID MZ 220 m Plug in PCle Cards 6 Gbs e LSI MegaRAID SAS 9266CV 8i RAID 8 port PCle plug in RAID controller card with on board 1 GB data cache and chassis mounted remote supercap for data cache power backup supporting RAID levels 0 1 5 6 10 50 60 and up to eight internal SAS SATA drives e LSI MegaRAID SAS 9266 81 8 port plug in PCle RAID RAID controller card with on board 1 GB flash backed write cache backup supporting RAID levels 0 1 5 6 10 50 60 and up to 8 internal SAS SATA drives e LSI MegaRAID 9285CV 8e PCle plug in RAID controller card with on board 1 GB cache and chassis mounted remote supercap for data cache power backup supporting RAID levels 0 1 5 6 10 50 60 Supports 8 external SAS ports up to 240 external drives Interfaces m Rear panel e One RJ 45 serial port connector e Two USB 2 0 port connectors e One DB15 VGA connector e Two RJ 45 10 100 1000 Ethernet port connectors e One RJ 45 10 100 1000 Ethernet management port using Cisco Integrated Management Controlle
8. SFF drives Up to eight 2 5 inch SAS or SATA hot swappable hard disk drives HDDs or solid state drives SSDs m The server also contains one internal USB 2 0 port on the motherboard that you can use with a USB thumb drive for additional storage The server supports one internal Cisco Flexible Flash drive SD card m The SD card is pre loaded with four virtual drives The four virtual drives contain respectively the Cisco Server Configuration Utility the Cisco Host Upgrade Utility the Cisco C Series server drivers set and a blank virtual drive on which you can install an OS or a hypervisor m 4 GBis available for general use The Emulex Pilot 3 Integrated Baseboard Management Controller provides video m Matrox G200e video controller m Integrated 2D graphics core with hardware acceleration m Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at 60 Hz m 24 bit color depth for all resolutions less than 1600x1200 m 256 MB video memory 6 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model BASE SERVER STANDARD CAPABILITIES and FEATURES Capability Feature Description Storage controller m Embedded RAID 3 Gbs e Embedded SATA only RAID controller supporting up to 4 SATA only drives RAID 0 1 10 e ROM5 embedded RAID upgrade supporting up to 8 SAS SATA drives RAID 0 1 10 e ROM55 embedded RAID upgrade supporting up to 8 SAS SATA drives RAID 0 1 5
9. See Figure 10 Figure 10 Zero Rack Unit PDU PID RP208 30 2P U 2 ony la a o ii z a a aa 2 z r G kp a i G f d He m th E5 281400 C13 plugs EE Breakers C19 plugs Ground connection Cisco RP Series PDU models provide two 20 ampere A circuit breakers for groups of receptacles The effects of a tripped circuit are limited to a receptacle group Simply press a button to reset that circuit 64 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL KVM CABLE The KVM cable provides a connection into the server providing a DB9 serial connector a VGA connector for a monitor and dual USB ports for a keyboard and mouse With this cable you can create a direct connection to the operating system and the BIOS running on the server The KVM cable ordering information is listed in Table 35 Table 36 KVM Cable Product ID PID PID Description N20 BKVM KVM cable for B Series Blade Server console port Figure 11 KVM Cable Connector to server front panel Ea VGA connector for a monitor DB 9 serial connector C8 Two port USB connector for a mouse and keyboard Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 65 SUPPLEMENTAL MATERIAL Motherboard USB and SD Ports and RAID Card Backup Location The C220 M3 SFF motherboard has a general pur
10. IUE Not a Not Card i oa mi no a 8 internal A allowed allowed default allowed Not Fani Installed 0 internal kola slot 1 or 240 slot 2 external Not Not Not Installed 8 internal slot 1 or 240 A A allowed allowed allowed slot 2 ay nd Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model allowed a b sent absent SUPPLEMENTAL MATERIAL Table 33 Supported RAID Configurations continued Internal Internal External Embedded Mezz Drives PCle RAID PCle PCle PCle Slots 2 CPUs RAID RAID 13 RAID 24 RAIDS Supported Installed 8 internal C220 M3 SFF 2 Pa Na slot 2 Paa Aa 240 default external Notes 1 You cannot mix RAID types You can use either embedded RAID mezzanine RAID or PCle RAID but only one at a time 2 Never disable OPROM for the mezzanine slot if the mezzanine card is present or the system will not boot If you remove the mezzanine card and disable its OPROM you can boot from another bootable device RAID card embedded RAID or from SAN via an HBA or CNA card When you boot from a device make sure its OPROM is enabled it is in the proper boot sequence and its BIOS is configured for a bootable device 3 If you want to boot from a device other than the 9266 81 or 9266CV 8i MegaRAID PCle cards you can leave the cards installed J ust disable the OPROM for their slots and the system will boot even with the cards installed 4 Dual RAID c
11. OO 1525 a20 O20 OPH a O O Q lt a O O O BO ET tas 05 O KO Ee NG 0 O O ET NG 05 O KO ET ta 5 O C2 O O QO fes 8 5 29 KO O sga O O e O O O a O O O O e O O Ka 03 o ES Sa OY lt a O O FAN4 O aXe OC SPER 08G 0004 awa one C 0 fe 3 E3 o Ko IN e 88 8 8 o PE FANS O O O90 ace 1020 OPH lt a O O Q 59 O BO la O a O O oQ OSO es 0 O a O O Q O Ee NG ea Q O lt 2 O O Q fes 8 3 So 1 Drives Trusted platform module socket on hot swappable accessed through front panel motherboard Drive backplane EE Standard profile PCle riser PCle slot 1 SuperCap backup unit mounting location Low profile PCle riser PCle slot 2 Cooling fans five Cisco Flexible Flash SD socket SD2 on PCle riser 2 SCU upgrade ROM header RAID key ki Cisco Flexible Flash SD socket SD1 on PCle riser 2 6 DIMM slots on motherboard 16 Internal USB port Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive
12. SERVER Approved Configurations 1 Onboard RAID Mezzanine Cards and all Plug In RAID Controllers m f you have not selected an onboard RAID upgrade option ROM5 or ROM55 a mezzanine card or a plug in RAID controller for internal drives LSI MegaRAID SAS 9266 8 or LSI MegaRAID SAS 9266CV 81 you may select up to 4 SATA only drives which will be controlled with the embedded SATA only RAID controller m Otherwise select up to eight SAS SATA drives listed in Table 8 You can mix SAS and SATA drives Caveats m You can mix SATA and SAS drives 24 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 6 SELECT PCle OPTION CARD s The standard PCie card offerings are m Converged Network Adapters CNAs m Network Interface Cards NICs m Host Bus Adapters HBAs Select PCle Option Cards The available PCle option cards are listed in Table 9 Table 9 Available PCle Option Cards Product ID PID PID Description Page Converged Network Adapters CNAs UCSC PCIE BSFP Broadcom 57712 Dual Port 10Gb SFP w TOE iSCSI Half UCSC PCIE CSC 02 Cisco VIC 1225 Dual Port 10Gb SFP CNA Half UCSC PCIE C10T 02 Cisco VIC 1225T Dual Port 10GBaseT CNA Half UCSC PCIE ESFP Emulex OCe11102 FX dual port 10 GbE FCoE CNA Gen 3 CNA Half UCSC PCIE QSFP Qlogic QLE8242 CU dual port 10 GbE FCoE CNA Half UCSC PCIE B3SFP Broadcom 57810 10Gb A FEX SFP Half Network Interface Car
13. SFS 250V 10A Israel Images pisaan 2500 mm 721 Ah Cordset rating 10 A 250 500 V MAX Plug EL 219 IRAM 2073 Length 8 2 ft Connector EL 701 IEC60320 C13 5 oy Plug EL 210 uga UNA Cordset rating 10 A 250 V 500 V MAX Length 2500mm Connector EL 701C EN 60320 C15 Jo BS 1363A 13 AMP fuse Plug EL 218 CCEE GB2009 i Cordset rating 10A 250V Connector EL 701 o IEC60320 C13 3 NIT OS Cordset rating 10A 16 A 250 V Length 8 ft 2 in 2 5 m Plug EL 208 i f Cordset rating 16A 250V m ra 2500mm IEC60320 C13 CONFIGURING the SERVER Table 13 Available Power Cords Product ID PID CAB 9K10A IT CAB 9K10A SW CAB 9K10A UK CAB 9K12A NA CAB PN 3PIN PID Description Images Power Cord 250VAC 10A CEI 23 16 VII Plug Italy j mii inne ordset rating nica C15M EN60320 C15 Power Cord 250VAC 10A MP232 Plug Switzerland ma 17 18
14. Standard profile PCle slot on riser USB ports full height half length x24 connector x16 lane width gt pw VGA video connector oa Rear Identification button LED Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 5 BASE SERVER STANDARD CAPABILITIES and FEATURES BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 lists the capabilities and features of the base server Details about how to configure the server for a particular feature or capability for example number of processors disk drives or amount of memory are provided in CONFIGURING the SERVER page 9 Table 1 Capabilities and Features Capability Feature Description Chassis One rack unit 1RU chassis CPU One or two Intel E5 2600 series processor family CPUs Chipset Intel C600 series chipset Memory 16 slots for registered or unbuffered ECC DIMMs RDIMMs or UDIMMs or load reduced DIMMs LRDIMMs NIC Embedded dual port Intel i350 PCle based Gigabit Ethernet controller Expansion slots Internal storage devices Cisco Flexible Flash drives Video supporting the following m Pre Execution Boot PXE boot m iSCSI boot Two PCle slots on a riser card m One full height profile half length slot with x24 connector and x16 lane m One half height profile half length slot with x16 connector and x8 lane Drives are Installed into front panel drive bays that provide hot pluggable access m Small Form Factor
15. You may also select an appropriate optional RAID configuration listed in Table 7 on page 20 2 bd 2 CPU Configurations Select an embedded RAID option from Table 5 or one mezzanine RAID controller from Table 6 on page 19 along with an external RAID controller if desired or one internal or external drive PCle RAID controller or one of each if desired from Table 7 on page 20 You may also select an appropriate optional RAID configuration listed in Table 7 on page 20 3 Available RAID Controller Combinations Q Caveats NOTE For more important information regarding RAID combinations and support see RAID Summary page 56 and RAID Option ROM OPROM Settings page 58 m Note that only a single Cisco VIC card the half height Cisco VIC 1225 PCle card is supported and it must be installed in the full height PCle slot slot 1 on riser 1 So take this into account when populating RAID controller cards m You can choose an optional RAID configuration RAID 0 1 5 6 or 10 which is preconfigured at the factory The RAID level you choose must be an available RAID choice for the controller selected RAID levels 50 and 60 are supported although they are not available as configuration options Q NOTE For more important information regarding RAID support see RAID Summary page 56 and RAID Option ROM OPROM Settings page 58 22 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model
16. external SAS ports up to 240 external drives NOTE For SAS 9285CV 8e external drive enclosure support see the O compatibility list enclosure section at the following link http tinyurl com b4etshk Cisco is able to support customers with questions related to the SAS 9285CV 8e RAID card however customers should contact their storage vendor for technical support related to enclosure BOD m Includes an chassis mount remote supercapacitor to power on board 1 GB flash backed write cache m Factory configured RAID options RAID 0 1 5 6 10 see the RAID Configuration section in this table Super Capacitor Option UCS RAID CV SC LSI CacheVault Power Module for SAS 9266CV 8i This is a spare supercapacitor It is the exact same supercapacitor that ships with the 9266CV 8i and 9285CV 8e cards listed earlier in this table and can be used as a replacement Or upgrade part 20 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Table 7 Available Plug In PCle Card RAID Options continued Product ID PID PID Description RAID Configuration Options not available for embedded RAID R2XX SRAIDO R2XX RAIDO R2XX RAID1 R2XX RAID5 R2XX RAID6 R2XX RAID10 Enable Single Disk Raid 0 Setting for the following PIDs only m UCS RAID 9266 NB m UCS RAID 9266CV m UCSC RAID 11 C220 m UCSC RAID MZ 220 Factory preconfigured RAID striping option
17. four SATA only drives RAID 0 1 10 Q NOTE When creating a RAID volume follow these guidelines m Use the same capacity for each drive in the volume m Use either all SAS drives or all SATA drives m Use either all HDDs or all SSDs 6 NOTE The number of RAID groups virtual drives supported per controller is as follows m Embedded RAID 8 m LSI MegaRAID 9266CV 8i RAID controller card 64 m LSI MegaRAID SAS 9266 8i RAID controller card 64 m LSI MegaRAID 9285CV 8e RAID controller card 64 m Cisco UCSC RAID SAS 2008M 8i Mezzanine Card 16 The RAID controller choices are 1 Embedded RAID on motherboard NOTE The RAID configuration options listed in Table 7 on page 20 are not available if you choose embedded RAID in this case you must configure RAID yourself using separate software 2 Mezzanine RAID controller cards not supported in 1 CPU configurations 3 Plug in PCle RAID controller cards Cisco can provide factory configured RAID systems depending on the RAID controller chosen and the number of drives ordered Factory configured RAID options are listed with each RAID card description 18 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Select RAID Options Select as follows these choices are dependent on the number of CPUs installed m One embedded RAID upgrade option or One mezzanine RAID controller or One me
18. in its socket without damage Must be used each time a CPU is installed in a UCS M3 server Instructions for using this tool set are found at the following link http www cisco com en US docs unified_ computing ucs c hw C220 install replace html wp1233864 NOTE When you purchase a spare CPU the Pick n Place Toolkit is included 60 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL Thermal Grease with syringe applicator for CPU to Heatsink Seal Thermal grease must be applied to the top of the CPU where it comes in contact with the heat sink Instructions for applying thermal grease are found at http www cisco com en US docs unified_ computing ucs c hw C220 install replace html wp1233864 CAUTION Use only the thermal grease specified for this server AA UCS CPU GREASE2 Thermal grease for other systems may have different thermal conductivity properties and may cause overheating if used in the C220 M3 server DO NOT use thermal grease available for purchase at any commercial electronics store If these instructions are not followed the CPU may overheat and be destroyed he o O NOTE When you purchase a spare CPU the thermal grease with syringe applicator NG is included Air Baffle Replacement Kit Air baffles are designed to direct airflow through the server to maintain server temperature at a safe operating level These baffles must
19. of Destruction CoD confirming that the drive has been removed from the system listed is no longer in service and has been destroyed Sophisticated data recovery techniques have made classified proprietary and confidential information vulnerable even on malfunctioning disk drives The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised which reduces the risk of any potential liabilities This service also enables you to comply with regulatory local and federal requirements If your company has a need to control confidential classified sensitive or proprietary data you might want to consider one of the Drive Retention Services listed in Table 26 Q NOTE Cisco does not offer a certified drive destruction service as part of this service Table 27 Drive Retention Service Options Service Service Service Description Program Name Level GSP Service Level Product ID PID SMARTnet for UCS UCSD7 24x7x4 Onsite CON UCSD7 C220M3SF Service with Drive UCS DR Retention UCSD7 8x5XNBD Onsite CON UCSD5 C220M3SF Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 45 46 CONFIGURING the SERVER Table 27 Drive Retention Service Options continued ee Service Service Service Description Program Name Level GSP Service Level Product ID PID SMART net for UCS UCWD7 24x7x4 Onsite CON UCWD7 C220M3SF HW ONLY Drive UCS HW D
20. x 8 GB 6 48 GB 96 GB 4x8 GB 4x4 GB 8 48 GB 4x8 GB 4x4 GB 8 48 GB 96 GB 7 xX 8 GB 7 56 GB 7 x8 GB 7 56 GB 112 GB 4x 16GB 4 64 GB 4x 16 GB 4 64 GB 128 GB 8 x 8 GB 8 64 GB 8 x 8 GB 8 64 GB 128 GB 2 x 32 GB 2 64 GB 2 x 32 GB 2 64 GB 128 GB 5 x 16 5 80 GB 5 x 16 5 80 GB 160 GB 4x16 GB 4x4 GB 8 80 GB 4x16 GB 4x4 GB 8 80 GB 160 GB 6 x 16 GB 6 96 GB 6 x 16 GB 6 96 GB 192 GB 4x8 GB 4x16 GB 8 96 GB 4x8 GB 4x16 GB 8 96 GB 192 GB 3 x 32 GB 3 96 GB 3 x 32 GB 3 96 GB 192 GB 7 Xx 16 GB 112GB 7x16 GB 7 112 GB 224 GB 8 x 16 GB 8 128 GB 8x16GB 8 128 GB 256 GB 4x 32 GB 4 128GB 4x 32GB 4 128 GB 256 GB 8 x 32 GB 8 256GB 8x 32GB 8 256 GB 512 GB 54 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL Low Voltage DIMM Considerations The C220 M3 server can be ordered with dual voltage 1 5 1 35 V DIMMs only Note the following considerations m Low voltage DIMMs within the server must have the identical manufacturer type speed and size m Low voltage DIMMs and standard voltage DIMMs can be mixed in the same server Note that this causes the system BIOS to default to standard voltage operation Performance Mode That is the server cannot operate in Power Saving Mode unless all DIMMs are low voltage DIMMs m CPUs that have a maximum memory frequency less than 1333 MHz support low voltage DIMMs operating in Power Saving Mode only and do not support Performance Mode Cisco UCS Cisc
21. 0 single rank x4 1 35v 135V 1 UCS MR 1X041RX A 4GB DDR3 1333 MHz RDIMM PC3 10600 single rank x4 1 35v 135V 1 UCS MU 1X042RE A 4GB DDR3 1600 MHz ECC UDIMM PC3 12800 dual rank x8 1 35v 1 35V 2 Memory Mirroring Option NO1 MMIRROR Memory mirroring option 14 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Approved Configurations 1 1 CPU configuration without memory mirroring m Select from 1 to 8 DIMMs Refer to Memory Population Rules page 52 for more detailed information 2 1 CPU configuration with memory mirroring m Select 2 4 6 or 8 identical DIMMs The DIMMs will be placed by the factory as shown in the following table Total CPU 1 DIMM Placement in Channels Number for identical DIMMs Nia Blue Slots Black Slots 2 Al B1 4 A1 B1 C1 D1 6 A1 B1 C1 D1 A2 B2 8 A1 B1 C1 D1 A2 B2 C2 D2 m Select the memory mirroring option NO1 MMIRROR as shown in Table 4 on page 14 3 2 CPU configuration without memory mirroring m Select from 1 to 8 DIMMs per CPU Refer to Memory Population Rules page 52 for more detailed information Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 15 CONFIGURING the SERVER 4 2 CPU configuration with memory mirroring m Select 2 4 6 or 8 identical DIMMs per CPU The DIMMs will be placed by the factory as shown in the following tab
22. 0Gb SFP CNA Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 27 CONFIGURING the SERVER Choose Optional SFP Modules Optical Cisco SFP modules are listed in Table 11 Table 11 Available SFP Modules Product ID PID PID Description SFP 10G SR 10GBASE SR SFP Module 850 nm multimode SR 3 3V LC connector with Digital Optical Monitoring DS SFP FC8G SW 8 Gbit SFP Module 850 nm multimode SR 3 3V LC connector with Digital Optical Monitoring Approved Configurations 1 Choose Up to Two SFP Modules for Each Network Card Ordered m You may choose one or two SFP optical modules cables for each network card ordered You would normally order two modules for connecting to the primary and redundant network switching equipment With the SFP optical modules you can use common fiber optic cables widely available See Figure 5 on page 29 for typical SFP and twinax connections to the network cards Caveats The SFP 10G SR optical module listed in Table 11 should be ordered only for the following PCle cards as they do not come by default with any optical modules UCSC PCIE BSFP Broadcom 57712 N2XX ABPCI02 Broadcom 57711 UCSC PCIE CSC 02 Cisco VIC 1225 Dual Port 10Gb SFP CNA The DS SFP FC8G SW optical module listed in Table 11 should be ordered only for the following PCle cards as they do not come by default with any optical modules N2XX AEPC105 Emu
23. 2 H2 m Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized m Observe the DIMM mixing rules shown in Table 29 Table 30 DIMM Rules for C220 M3 Servers DIMM Parameter Mix Across a Single Bank DIMM Size RDIMM 4 8 or 16 GB No Must be same size in the same bank 2 You cannot mix 32 GB BAN ean LRDIMMs with any RDIMM DIMM Speed 1333 or 1600 MHz No Must be same speed in the same bank DIMM Type RDIMMs or LRDIMMs You cannot mix LRDIMMs with RDIMMS 1 DPC or 2 DPC 32 GB DIMM Population Notes Mix Across Multiple Bank Yes Different banks can use different DIMM sizes as long as all DIMMs in a single bank use the same DIMM size You cannot mix 32 GB LRDIMMs with any RDIMM Yes but if DIMMs of mixed speed are used the server will clock down to the lowest speed You cannot mix LRDIMMs with RDIMMS DIMMs will run at 1333 MHz at either 1 35 Vor1 5V 1 Only 1333 and 1600 MHz DIMMs are currently available for the C220 M3 server 52 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL Recommended Memory Configuration This section explains the recommended DIMM population order rules for the C220 M3 server m All DIMMs must be DDR3 DIMMs m Do not mix DIMMs with different sizes or clock rates in a bank RDIMMs and LRDIMMs ECC and non ECC DIMMs m There are blue and black DIMM slots Populate blu
24. 220 M3 High Density SFF Rack Server Figure 2 Chassis Front View eee Hat A D7 Ka EBL HODS LE H01 8 7 HDD2 8 Hons 81 bo BONG Riese pag EE a Thons Eat IIs PAY cpa 3 Gas xX E 331682 7 Power button power status LED 6 Power supply status LED EE Identification button LED To Network link activity LED 3 System status LED status LED 8 Asset tag serial number i status LED LE connector used with KVM cable that provides two ea one VGA and one serial connector Li Temperature status LED bd Drives up to eight hot swappable 2 5 inch drives For more information about the KVM cable connection see KVM CABLE page 65 4 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model DETAILED VIEWS Chassis Rear View Figure 3 shows the external features of the rear panel Figure 3 Chassis Rear View Od PCle1 OAD na GaSe ae Se SSSeseeea O 7 mr Sa Pe N n H papano H ASS ee 331683 Power supplies up to two One 10 100 1000 Ethernet dedicated management port Slot 2 Low profile PCle slot on riser Dual 1 Gb Ethernet ports half height half length x16 connector x8 LAN1 and LAN2 lane width Slot 1
25. AS and SATA drives can be mixed m Factory configured RAID options available RAID O 1 and 10 see the RAID PIDs section in this table m No data cache backup Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 19 CONFIGURING the SERVER Table 7 Available Plug In PCle Card RAID Options Product ID PID PID Description RAID Controllers Note that plug in PCle RAID controllers are installed by default in slot 1 for 1 CPU systems and slot 2 for 2 CPU systems UCS RAID 9266CV LSI MegaRAID SAS 9266CV 8i RAID controller card with data cache backup RAID 0 1 10 5 6 50 60 operating at 6 Gbs m Supports up to eight internal SAS SATA drives SAS and SATA drives can be mixed m Includes a 1 GB Transportable Memory Module TMM and a chassis mounted remote supercapacitor for data cache power backup m Factory configured RAID options available RAID O 1 5 6 and 10 see the RAID PIDs section in this table UCS RAID 9266NB LSI MegaRAID SAS 9266 81 RAID controller card with no data cache backup RAID 0 1 5 6 10 50 and 60 supported operating at 6 Gbs m Supports up to eight internal SAS SATA drives SAS and SATA drives can be mixed m Includes 1 GB of write cache m Factory configured RAID options available RAID 0 1 5 6 and 10 see the RAID PIDs section in this table UCS RAID 9285CV E LSI MegaRAID SAS 9285CV 8e RAID 0 1 5 6 10 m Supports from one to eight
26. ATE KENT EE CISCO Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN J OSE CA 95134 Rev B 11 MARCH 20 2013 WWW CISCO COM OVERVIEW wang 28 eA Ee KAG eee a ee ee DS 3 DETAILED VIEWS 64 044 6 64 869 KAB DAG WADA DN LABAG AA GANG BAD WA AA 4 Chassis Front VIEW xx wa GA KKK Goh DEG EOE EAD Pe NG KAPA MA KIA AG PAM PA 4 Chassis Rear View 2a 5 BASE SERVER STANDARD CAPABILITIES and FEATURES rss 6 CONFIGURING the SERVER 2 000 cee ee eee eee eee eee ees 9 Slee AL VERY SERVEROKU o aod oes ee oO Oe EOS ee ee eee a ao ee ae 10 SIEF ZOELECL GPUS ca ace ho ha tae eS eT EE Sad ES a Oe 11 SIEP 3 SELECT MEMORY 22x nanan akwi k4 BAGA he ee eee eee ee 13 STEP 4 SELECT RAID CONFIGURATION 0 00 0 ee aa 18 STEP 5 SELECT HARD DISK DRIVES HDDs or SOLID STATE DRIVES SSDs 23 STEP 6SELECT PCle OPTION CARD s ouaaa ee 25 STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES 000000 ee eens 27 STEP 8 ORDER POWER SUPPLY 0 aa 30 STEP 9 SELECT AC POWER CORD s 00222 31 STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM 34 STEP 11 ORDER A TRUSTED PLATFORM MODULE OPTIONAL 0005 35 STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE OPTIONAL 36 STEP 13 ORDER OPTIONAL USB 2 0 DRIVE 2 2022 a aa 37 STEP 14 SELECT OPERATING SYSTEM 02
27. Enable RAID 0 Setting Requires a minimum of one hard drive Factory preconfigured RAID mirroring option Enable RAID 1 Setting Requires exactly two drives with the same size speed Capacity Factory preconfigured RAID option Enable RAID 5 Setting Requires a minimum of three drives of the same size speed capacity Factory preconfigured RAID option Enable RAID 6 Setting Requires a minimum of four drives of the same size speed capacity Factory preconfigured RAID option Enable RAID 10 Setting Requires a even number of drives minimum of four drives of the same size speed capacity Q NOTE Although RAID levels 50 and 60 are not orderable from the factory they are supported for selected controllers as shown in Table 5 Approved Configurations 1 1 CPU Configurations Mezzanine cards are not supported for 1 CPU configurations Therefore only the following RAID controllers are supported for single CPU configurations Embedded RAID on motherboard LSI MegaRAID SAS 9266 8i PCle slot 1 only LSI MegaRAID SAS 9266CV 8i PCle slot 1 only LSI MegaRAID SAS 9285CV e PCle slot 1 only O NOTE PCle slot 2 is not supported for 1 CPU configurations Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 21 CONFIGURING the SERVER Select an embedded RAID option from Table 5 on page 19 or one internal or external drive PCle RAID controller or one of each from Table 7 on page 20
28. Guest 3Yr Svcs Required RHEL 2 Socket 4 Guest 1Yr Svcs Required RHEL 2 Socket 4 Guest 3Yr Svcs Required RHEL 2 Socket U Guest 1Yr Svcs Required RHEL 2 Socket U Guest 3Yr Svcs Required RHEL Option High Availability 2 Socket 1Yr Svcs Required RHEL Option Resilient w Ha 2 Socket 1 Yr Svcs Required RHEL Option Scalable File System 2 Socket 1 Yr Svcs Required RHEL Option High Availability 2 Socket 3Yr Svcs Required RHEL Option Resilient Storage w HA 2 Socket 3 Yr Svcs Reqd RHEL Option Scalable File System 2 Socket 3 Yr Svcs Required Windows Server MSWS 08R2 STHV MSWS 08R2 ENHV Windows Svr 2008 EN media R2 EN 1 8CPU 25CAL MSWS 08R2 DCHV2S Windows Svr 2008 R2 2 CPU Data Center MSWS 08R2 DCHV4S Windows Svr 2008 R2 4 CPU Data Center VMWare Server VMW VS5 STD 1A VMW VS5 STD 2A Windows Svr 2008 ST media R2 ST 1 4CPU 5CAL VMware vSphere 5 Standard for 1 Processor 1 Year Support Required VMware vSphere 5 Standard for 1 Processor 2 Year Support Required Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Table 19 Operating Systems continued PID Description VMW VS5 STD 3A VMW VS5 STD 4A VMW VS5 STD 5A VMW VS5 ENT 1A VMW VS5 ENT 2A VMW VS5 ENT 3A VMW VS5 ENT 4A VMW VS5 ENT 5A VMW VS5 ENTP 1A VMW VS5 ENTP 2A VMW VS5 ENTP 3A VMW VS5 ENTP 4A VMW VS5 ENTP 5A Product ID PID VMware vSphere 5 Standard for 1 Processor 3 Ye
29. HOOD OSGOO OOOO GRE 00000 Oss eX e3 EI y FAN5 GRE H q INBOO 0000 00000 OOOO lere oo 0000 90600 HOOD rexel lieve HOOD GRE OOGOO 331714 a SD1 socket Em USB connector 2 SD2 socket CE SuperCap module mounting location 66 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 37 UCS C220 M3 Dimensions and Weight Parameter Value Height 1 7 in 4 32 cm Width 16 92 in 43 0 cm Depth 28 5 in 72 4cm Front Clearance 3 in 76 mm Side Clearance lin 25 mm Rear Clearance bin 152 mm Weight Maximum 8 HDDs 2 CPUs 16 DIMMs 2 power supplies 35 6 Ibs 16 2 kg Minimum 1 HDD 1 CPU 1 DIMM 1 power supply 26 8 Ibs 12 1 kg Bare 0 HDD 0 CPU O DIMM 1 power supply 22 Ibs 10 kg Power Specifications The general power specifications for the C220 M3 SFF server 450 W power supply are listed in Table 37 Table 38 UCS C220 M3 SFF 450 W Power Supply Specifications Description Specification AC input voltage 90 to 264 VAC self ranging 100 to 120 VAC nominal 200 to 240 VAC nominal AC input frequency Range 47 to 63 Hz single phase 50 to 60 Hz nominal Maximum AC input current 7 6 A peak at 100 VAC 3 65 A peak at 208 VAC Maximum AC inrush current 11A Maximum output power for each 450 W power supply Power supply output
30. Model 49 SUPPLEMENTAL MATERIAL CPUs and heatsinks two Power supplies two hot swappable access through rear panel Integrated RAID on motherboard and mini SAS 17 RTC battery on motherboard connectors Mezzanine RAID card mini SAS connectors Software RAID 5 header RAID key SAS1 and SAS2 CPUs and DIMMs Physical Layout Each CPU has four DIMM channels m CPUl has channels A B C and D m cCPU2 has channels E F G and H Each DIMM channel has two banks bank 1 and bank 2 The blue colored DIMM slots are for bank 1 and the black colored slots are for bank 2 As an example DIMM slots Al B1 C1 and D1 belong to bank 1 while A2 B2 C2 and D2 belong to bank 2 Figure 7 shows how banks and channels are physically laid out on the motherboard The DIMM slots on the right channels A B C and D are associated with CPU1 while the DIMM slots on the left channels E F G and H are associated with CPU2 The bank 1 blue DIMM slots are always located farther away from a CPU than the corresponding bank 2 black slots Bank 1 slots blue are populated before bank 2 slots black 50 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL Figure 7 Physical Layout of CPU DIMM Channels and Banks C 2 a D1 D2 Uu OK
31. R Partner Support Service for UCS provides hardware and software support including triage support for third party software backed by Cisco technical resources and level three support See Table 23 Table 24 Partner Support Service for UCS Service Product ID PID Level si Description Site GSP CON P5 1 C220M3SF PSJ 1 No UCS SUPP PSS 8X5XNBD UCS C220 M3 SFF CON PSJ 2 C220M3SF PSJ 2 No UCS SUPP PSS 8X5X4 UCS C220 M3 SFF CON PS 3 C220M3SF PSJ 3 No UCS SUPP PSS 24X7X4 UCS C220 M3 SFF CON PSJ 4 C220M3SF PSJ 4 No UCS SUPP PSS 24X7X2 UCS C220 M3 SFF Partner Support Service for UCS Hardware Only provides customers with replacement parts in as little as two hours See Table 24 Table 25 Partner Support Service for UCS Hardware Only Product ID PID eee ae Description CON PSW2 C220M3SF PSW2 No UCS W PL PSS 8X5X4 UCS C220 M3 SFF CON PSW3 C220M3SF PSW3 No UCS W PL PSS 24X7X4 UCS C220 M3 SFF CON PSW4 C220M3SF PSW4 No UCS W PL PSS 24X7X2 UCS C220 M3 SFF Unified Computing Combined Support Service Combined Services makes it easier to purchase and manage required services under one contract SMART net services for UCS help increase the availability of your vital data center infrastructure and realize the most value from your unified computing investment The more benefits you realize from the Cisco Unified Computing System Cisco UCS the more important the technology becomes to your business These services allow you to m Optimi
32. R Retention UCWD5 8x5xNBD Onsite CON UCWD5 C220M35SF For more service and support information see the following URL http www cisco com en US services ps2961 ps10312 Unified_Computing Services Overview pdf For a complete listing of available services for Cisco Unified Computing System see this URL http www cisco com en US products ps10312 serv_group_home html Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model OPTIONAL STEP ORDER RACK s OPTIONAL STEP ORDER RACK s The optional R42610 rack is available from Cisco for the C Series servers including the C220 M3 SFF server This rack is a Standard 19 inch rack and can be ordered with a variety of options as listed in Table 27 Racks are shipped separately from the C220 M3 SFF server Table 28 Racks and Rack Options Product ID PID RACK UCS RACK UCS2 RACK BLANK 001 RACK CBLMGT 001 RACK CBLMGT 011 RACK FASTEN 001 RACK FASTEN 002 RACK OIN 001 Notes PID Description Cisco R42610 expansion rack no side panels Cisco R42610 standard rack w side panels Filler panels qty 12 1U plastic toolless Cable mgt D rings qty 10 metal Cable mgt straps qty 10 Velcro Mounting screws qty 100 M6 Cage nuts qty 50 M6 Rack joining kit 1 Use these same base PIDs to order spare racks available only as next day replacements For more information about the R42610 rack see RACKS page 62 Cisco UCS Ci
33. S13438 Class A EMC Immunity EN55024 CISPR24 EN300386 KN24 NE KENT IT CISCO Americas Headquarters Asia Pacific Headquarters Europe Headquarters Cisco Systems Inc Cisco Systems USA Pte Ltd Cisco Systems International BV Amsterdam San Jose CA Singapore The Netherlands Cisco has more than 200 offices worldwide Addresses phone numbers and fax numbers are listed on the Cisco Website at www cisco com go offices Cisco and the Cisco Logo are trademarks of Cisco Systems Inc and or its affiliates in the U S and other countries A listing of Cisco s trademarks can be found at www cisco com go trademarks Third party trademarks mentioned are the property of their respective owners The use of the word partner does not imply a partnership relationship between Cisco and any other company 1005R 70 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model
34. SELECT HARD DISK DRIVES HDDs or SOLID STATE DRIVES SSDs page 23 STEP 6 SELECT PCle OPTION CARD s page 25 STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES page 27 STEP 8 ORDER POWER SUPPLY page 30 STEP 9 SELECT AC POWER CORD s page 31 STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM page 34 STEP 11 ORDER A TRUSTED PLATFORM MODULE OPTIONAL page 35 STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE OPTIONAL page 36 STEP 13 ORDER OPTIONAL USB 2 0 DRIVE page 37 STEP 14 SELECT OPERATING SYSTEM page 38 STEP 15 SELECT OPERATING SYSTEM MEDIA KIT page 40 STEP 16 SELECT OPTIONAL VALUE ADDED SOFT WARE page 41 STEP 17 SELECT SERVICE and SUPPORT LEVEL page 42 OPTIONAL STEP ORDER RACK s page 47 OPTIONAL STEP ORDER PDU page 48 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 9 CONFIGURING the SERVER STEP 1 VERIFY SERVER SKU Verify the product ID PID of the server as shown in Table 2 Table 2 PID of the C220 M3 High Density SFF Rack Base Server Product ID PID Description UCSC C220 M3S UCS C220 M3 SFF no CPU memory HDD SDD power supply SD card or PCle cards with 1 rail kit The Cisco C220 M3 server m Includes one tool less rail kit m Does not include power supply CPU memory hard disk drives HDDs solid state drives SSDs SD card or plug in PCle cards Q NOTE Use the steps on the following pages to configure the server with the compo
35. SMARTnet for UCS Service includes flexible hardware replacement options including replacement in as little as two hours There is also access to Cisco s extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment You can choose a desired service listed in Table 21 Table 22 Cisco SMARTnet for UCS Service Product ID PID On Site Description CON PREM C220M3SF Yes ONSITE 24X7X2 UCS C220 M3 SFF CON OSP C220M3SF Yes ONSITE 24X7X4 UCS C220 M3 SFF CON OSE C220M3SF Yes ONSITE 8X5X4 UCS C220 M3 SFF CON OS C220M3SF Yes ONSITE 8X5XNBD UCS C220 M3 SFF CON S2P C220M3SF No SMARTNET 24X7X2 UCS C220 M3 SFF CON SNTP C220M3SF No SMARTNET 24X7X4 UCS C220 M3 SFF CON SNTE C220M3SF No SMARTNET 8X5X4 UCS C220 M3 SFF CON SNT C220M3SF No SMARTNET 8X5XNBD UCS C220 M3 SFF 42 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER SMARTnet for UCS Hardware Only Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty Cisco offers the Cisco SMARTnet for UCS Hardware Only Service You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours SMARTnet for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization RMA is required You can choose a service lis
36. TED PLATFORM MODULE OPTIONAL Trusted Platform Module TPM is a computer chip microcontroller that can securely store artifacts used to authenticate the platform server These artifacts can include passwords certificates or encryption keys A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy Authentication ensuring that the platform can prove that it is what it claims to be and attestation a process helping to prove that a platform is trustworthy and has not been breached are necessary steps to ensure safer computing in all environments The TPM ordering information is listed in Table 15 Table 15 Trusted Platform Module Product ID PID PID Description UCSX TPM1 001 Trusted Platform Module Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 35 CONFIGURING the SERVER 36 STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE OPTIONAL You can order one optional preloaded 16 GB Cisco Flexible Flash secure digital SD card This SD card contains preloaded software for simplified server operation The ordering information is listed in Table 16 Table 16 Secure Digital SD Card preloaded with software Product ID PID PID Description UCSC SD 16G C220 16GB SD Card for C220 servers See Figure 6 on page 49 for the location of the SD cards There are two locations SD1 and SD2 NOTE You can order an optional second
37. VM KVM local IO cable for UCS servers console port UCS CPU EP PNP Pick n place CPU tool set for Intel E5 EP Socket R UCS CPU GREASE2 C220 and C240 CPU thermal grease syringe needed for heatsink seal UCSX HSCK UCS Processor Heat Sink Cleaning Kit when replacing a CPU Notes 1 This part is included configured with your UCS server in some cases as determined by the configuration of your server Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 59 SUPPLEMENTAL MATERIAL 2 If your server contains an LSI MegaRAID SAS 9266 81 RAID controller card with battery backup UCS RAID 9266 the card contains a battery backup unit UCS RAID BBU which can be replaced If your server contains an LSI MegaRAID SAS 9266 8 RAID controller card without a battery backup unit UCS RAID 9266NB the card does not contain a battery backup unit UCS RAID BBU however you can retrofit the card with a battery backup if desired Note that you cannot retrofit a UCS RAID 9266NB or UCS RAID 9266 RAID card with an LSI Cachevault Power Module also known as a Supercap 3 You can order a replacement only for the RAID cards listed You cannot retrofit a UCS RAID 9266NB or UCS RAID 9266 RAID card with an LSI Cachevault Power Module also known as a Supercap The server is shipped with the inner rail attached to the chassis This SD card is preloaded with an image specific to the C220 server This SD card
38. ack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 16 SELECT OPTIONAL VALUE ADDED SOFTWARE You can select from a variety of value added software listed in Table 20 Table 21 Value Added Software Product ID PID BMC SE 4C BMC SE 6C BMC SE 8C BMC SE 10C BMC AE 4C BMC AE 6C BMC AE 8C BMC AE 10C BMC 002 BMC 012 VMW VC5 STD 1A VMW VC5 STD 2A VMW VC5 STD 3A VMW VC5 STD 4A VMW VC5 STD 5A N1K VLEM UCS 1 N1K CSK9 UCS 404 PID Description BMC BladeLogic Standard Edition 4 Cores Support Required BMC BladeLogic Standard Edition 6 Cores Support Required BMC BladeLogic Standard Edition 8 Cores Support Required BMC BladeLogic Standard Edition 10 Cores Support Required BladeLogic Advanced Edition 4 Cores Support Required BMC BladeLogic Advanced Edition 6 Cores Support Required BMC BladeLogic Advanced Edition 8 Cores Support Required BMC BladeLogic Advanced Edition 10 Cores Support Required BMC BladeLogic CM for Physical Cisco Servers BMC BPPM Per Server VMware vCenter 5 Standard for 1 Processor 1 Year Support Required VMware vCenter 5 Standard for 1 Processor 2 Year Support Required VMware vCenter 5 Standard for 1 Processor 3 Year Support Required VMware vCenter 5 Standard for 1 Processor 4 Year Support Required VMware vCenter 5 Standard for 1 Processor 5 Year Support Required Nexus 1000V License PAK for 1 Virtual Ethernet module Nexus 1000V VSM Virtual Appliance Software
39. ae ee ee eee ae ew Ga eee 65 Motherboard USB and SD Ports and RAID Card Backup Location 66 TECHNICAL SPECIFICATIONS 2 00 cee ee eee es 67 Dimensions and Weight 0 ee 67 Power Specifications va 6ceaee Ce AA ew aS 67 Environmental Specifications 0 a 69 Compliance Requirements 0 0 ee ee 70 2 Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model OVERVIEW OVERVIEW The Cisco UCS C220 M3 rack server is designed for performance and density over a wide range of business workloads from web serving to distributed database Building on the success of the Cisco UCS C200 M2 rack server the enterprise class UCS C220 M3 server further extends the capabilities of Cisco s Unified Computing System portfolio in a 1U form factor with the addition of the Intel E5 2600 series product family CPUs that deliver significant performance and efficiency gains In addition the UCS C220 M3 server provides 16 DIMM slots up to 8 drives and 2 x 1 GbE LAN on motherboard LOM ports delivering outstanding levels of density and performance in a compact 1U package Figure 1 Cisco UCS C220 M3 High Density SFF Rack Server Front View Po HAH a E a Rear View TEY U teaa a ls Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 shows the Cisco UCS C
40. always remain installed during server operation The Air Baffle Replacement Kit includes the air baffles needed for one UCS C220 M3 server CPU Heat Sink Cleaning Kit The cleaning kit is used to remove the existing thermal compound from the bottom of the heat sink during a CPU replacement process Instructions for cleaning are found at the following link http www cisco com en US docs unified computing ucs c hw C220 install replace html wp1233864 O NOTE When you purchase a spare CPU the CPU cleaning kit is included NG Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 61 SUPPLEMENTAL MATERIAL RACKS The Cisco R42610 rack see Figure 9 is certified for Cisco UCS installation at customer sites and is suitable for the following equipment m Cisco UCS B Series servers and fabric interconnects m Cisco UCS C Series and select Nexus switches The rack is compatible with hardware designed for ElA standard 19 inch racks Rack specifications are listed in Table 34 Table 35 Cisco R42610 Rack Specifications Parameter Dimensions H x W x D Dimensions H x W x D with packaging Distance from front mounting rail to rear mounting rail Weight Weight with packaging Side panels included Equipment mounting Capacity Static load capacity Dynamic load capacity Standard Rack 78 74 x 24 x 43 38 in 2000 x 610 x 1102 mm 89 x 33 x 47 In 2261 x 838 x 1194
41. and B must be identical and pairs in channels C and D must be identical However the DIMMs used in channels A and B and in C and D can be different m Non ECC DIMMs are not supported m Memory mirroring reduces the amount of available memory by 50 quantity of DIMMs must be even for mirroring m When single and dual rank DIMMs are populated for 2DPC always populate the dual rank DIMM in the blue DIMM slot and the single rank DIMM in the black DIMM slot only the 4GB DIMMs are single rank m By default all DIMMs run at 1 35 V which yields 1333 MHz memory speeds To run the memory DIMMS at 1600 MHz you need to go into the BIOS or set the policy with UCSM service profile to run in Performance Mode This forces the DIMMs to operate at 1 5 V and yields 1600 MHz speeds provided The DIMMs are 1600 MHz devices and the DIMM type is RDIMM The CPUs chosen support 1600 MHz operation O NOTE 32 GB LRDIMMs run at a maximum speed of 1333 MHz for 1DPC and 2DPC even GS though their specified maximum speed is 1600 MHz For more information regarding memory see CPUs and DIMMs page 50 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 17 CONFIGURING the SERVER STEP 4 SELECT RAID CONFIGURATION NOTE If you do not select a mezzanine card a plug in PCle RAID card or one of the embedded RAID upgrade options you will have an embedded SATA only RAID controller that supports up to
42. ar Support Required VMware vSphere 5 Standard for 1 Processor 4 Year Support Required VMware vSphere 5 Standard for 1 Processor 5 Year Support Required VMware vSphere 5 Enterprise for 1 Processor 1 Year Support Required VMware vSphere 5 Enterprise for 1 CPU 2 Yr Support Required VMware vSphere 5 Enterprise for 1 CPU 3 Yr Support Required VMware vSphere 5 Enterprise for 1 Processor 4 Year Support Required VMware vSphere 5 Enterprise for 1 CPU 5 Yr Support Required VMware vSphere 5 Enterprise Plus for 1 Processor 1 Year Support Required VMware vSphere 5 Enterprise Plus for 1 CPU 2 Yr Support Required VMware vSphere 5 Enterprise Plus for 1 Processor 3 Year Support Required VMware vSphere 5 Enterprise Plus for 1 Processor 4 Year Support Required VMware vSphere 5 Enterprise Plus for 1 Processor 5 Year Support Required Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 39 CONFIGURING the SERVER STEP 15 SELECT OPERATING SYSTEM MEDIA KIT Select the optional operating system media listed in Table 19 Table 20 OS Media Product ID PID RHEL 6 SLES 11 MSWS 08R2 STHV RM MSWS 08R2 ENHV RM MSWS 08R2 DCHV RM PID Description RHEL 6 Recovery Media Only Multilingual SLES 11 media only multilingual Windows Svr 2008 R2 ST 1 4CPU 5CAL Media Windows Svr 2008 R2 EN 1 8CPU 25CAL Media Windows Svr 2008 R2 DC 1 8CPU 25CAL Media 40 Cisco UCS Cisco UCS C220 M3 High Density R
43. blank SD card The PID for the second SD blank card is shown in Table 17 Q Table 17 Second Secure Digital SD Card blank Product ID PID PID Description UCSC SD 16G 16GB SD Card optional Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 13 ORDER OPTIONAL USB 2 0 DRIVE You can order one optional USB 2 0 drive The USB drive ordering information is listed in Table 17 Table 18 USB 2 0 Drive Product ID PID PID Description UCS USBFLSH S 4GB 4GB Flash USB Drive shorter length for all servers except C260 See Figure 6 on page 49 for the location of the USB connector Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 37 CONFIGURING the SERVER 38 STEP 14 SELECT OPERATING SYSTEM Several operating systems are available from which to choose Select one of the operating systems shown in Table 18 Table 19 Operating Systems PID Description Product ID PID SUSE Linux Enterprise Server SLES 1A SLES 3A SLES lyr subscription svcs required 0 media SLES 3yr subscription svcs required 0 media Red Hat Enterprise Linux RHEL 2S 1G 1A RHEL 2S 1G 3A RHEL 2S 4G 1A RHEL 25 4G 3A RHEL 2S UG 1A RHEL 2S UG 3A RHEL Add Ons RHEL HA 2S 1A RHEL RS 2S 1A RHEL SFS 2S 1A RHEL HA 25 3A RHEL RS 2S 3A RHEL SFS 2S 3A RHEL 2 Socket 1 Guest 1Yr Svcs Required RHEL 2 Socket 1
44. ds NICs N2XX ABPCIO1 M3 Broadcom 5709 Dual Port 1Gb w TOE iSCSI for M3 Servers Half N2XX ABPCI03 M3 Broadcom 5709 Quad Port 1Gb w TOE iSCSI for M3 Servers Half N2XX AIPCIO1 Intel X520 Dual Port 10Gb SFP Adapter Half UCSC PCIE ITG Intel X540 Dual Port 10GBase T Adapter Half UCSC PCIE IRJ 45 Intel i1350 Quad Port 1Gb Adapter Half UCSC PCIE BTG Broadcom 57712 Dual Port 10GBASE T w TOE iSCSI Half Host Bus Adapters HBAs N2XX AEPCI03 Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA Half N2XX AEPCI05 Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Half N2XX AQPCI03 Qlogic QLE2462 Dual Port 4Gb Fibre Channel HBA Half N2XX AQPCI05 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA Half Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 25 CONFIGURING the SERVER Approved Configurations 1 No RAID controller plug in card If you did not choose a plug in RAID controller for example you are using embedded RAID Or a mezzanine RAID controller you can select up to one PCie option card for 1 CPU systems or two PCie option cards for 2 CPU systems listed in Table 9 on page 25 2 One RAID controller plug in card If you selected a plug in PCle RAID controller you can select none of the optional PCle cards for 1 CPU systems or one of the optional PCle cards for 2 CPU systems listed in Table 9 on page 25 NOTE If a plug in RAID controller card is installed any optional PCle card you select
45. e slots first m When single and dual rank DIMMs are populated for 2DPC always populate the dual rank DIMM in the blue DIMM slot and the single rank DIMM in the black DIMM slot Many memory configurations are possible For best results follow Table 30 when populating DIMMs Table 31 Recommended Memory Configurations DIMM Max Total Blue Slots Black Slots Blue Slots Black Slots Operating DIMMs in Bank 1 Bank 2 Bank 1 Bank 2 Speed the pon B1 o B2 pag F1 mb F2 Notes 1 Rows marked in yellow indicate best performance 2 Even though the specified maximum speed of 32 GB LRDIMMs is 1600 MHz they run at a maximum speed of 1333 MHz in 2DPC configurations Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 53 SUPPLEMENTAL MATERIAL Supported DIMM Populations The supported DIMM populations are listed in Table 31 Table 32 Supported DIMM Configurations curom THINS PUL couzpmms TDMS CPU Capacity for S 1 x 8 GB 1 8 GB 1 x 8 GB 1 8 GB 16 GB 1 x 16 GB 1 16 GB 1 x 16 GB 1 16 GB 32 GB 2X4 GB 2 8 GB 2X4 GB 2 8 GB 16 GB 4X4 GB 4 16 GB 4x4 GB 4 16 GB 32 GB 2 x 8 GB 2 16 GB 2 x8 GB 2 16 GB 32 GB 6 x 4GB 6 24 GB 6 x 4GB 6 24 GB 48 GB 8 xX 4 GB 8 32 GB 8 x 4GB 8 32 GB 64 GB 4x8 GB 4 32 GB 4x8 GB 4 32 GB 64 GB 8X4 GB 8 32 GB 8X4 GB 8 32 GB 64 GB 1 x 32 GB 1 32 GB 1 x 32 GB 1 32 GB 64 GB 5 x 8 GB 5 40 GB 5 x 8 GB 5 40 GB 80 GB 3 x 16 GB 3 48 GB 3 x 16 GB 3 48 GB 96 GB 6 x 8 GB 6 48 GB 6
46. is blank The required image for the C220 server can be downloaded to the card This part is included configured with the server chassis This part is included with the purchase of an optional or spare CPU processor kit COM QO UI RA Drive Blanking Panels A drive blanking panel N20 BBLKD must be installed if you remove a disk drive from a UCS server These panels are required to maintain system temperatures at safe operating levels and to keep dust away from system components Adding an Additional CPU with CPU heat sink All Cisco UCS two CPU socket capable servers can be upgraded from having one to having two CPUs configured You will need to order and install a heat sink when adding any additional CPU to a server Instructions for installing the new CPU and heat sink can be found at the following link http www cisco com en US docs unified_ computing ucs c hw C220 install replace html wp1233864 Motherboard Lithium Battery You can order a replacement motherboard battery Installation instructions are found at this link http www cisco com en US docs unified computing ucs c hw C220 install replace html wp1235772 CPU Removal and Installation pick n place Tool Set The Pick n Place tool set includes two tools m Pick and pull cap tool used to pull off the plastic protective cap covering an empty CPU socket and to remove or lift a CPU processor without touching it m Pick and place tool used to install a CPU
47. ity Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL Upgrade and Servicing Related Parts This section lists the upgrade and servicing related parts you may need during the life of your server Some of these parts are configured with every server and some may be ordered when needed or may be ordered and kept on hand as spares for future use See Table 33 Table 34 Upgrade and Servicing related Parts for UCS C220 M3 SFF Server Spare Product ID PID Description N20 BBLKD 2 5 inch HDD Blanking Panel UCSC CABLE1 Set of two 2 SAS SATA Cables for C220 M3 SFF 2 5 in UCSC PCIF O1H PCle Low Profile blanking panel for UCS C Series Server UCSC PCIF O1F PCle Full Height blanking panel for UCS C Series Server UCSC HS C220M3 Heat Sink for UCS C220 M3 Rack Server UCSC AIRBAF C220 Air Baffle Replacement Kit for C220 M3 Server N20 MBLIBATT Replacement Lithium Battery for Server Motherboard CR2032 UCS RAID BBU Battery Back Up for 92662 UCS RAID CV SC LSI CacheVault Power Module 9266CV 9265CV and 9285CV 8e UCSC PSU BLKP Power supply blanking panel filler for C Series Servers UCSC CMA1 Reversible Cable Management Arm for C220 rack servers UCSC RAIL1 Rail Kit for C220 rack servers UCSC RAIL1 l Inner rail spare for C2204 UCSC SD 16G C220 16GB SD Card for C220 Servers UCS SD 16G Blank SD Card for UCS servers UCS USBFLSH S 4GB 4GB SLC Flash USB Drive shorter for all servers except C260 N20 BK
48. le Number CPU 1 DIMM Placement in Channels CPU 2 DIMM Placement in Channels of for identical dual rank DIMMs for identical dual rank DIMMs se Gh Blue Slots Black Slots Blue Slots Black Slots 2 Al B1 E1 F1 4 A1 B1 C1 D1 E1 F1 G1 H1 6 A1 B1 C1 D1 A2 B2 E1 F1 G1 H1 E2 F2 8 A1 B1 C1 D1 A2 B2 C2 D2 E1 F1 G1 H1 E2 F2 G2 H2 m Select the memory mirroring option N01 MMIRROR as shown in Table 4 on page 14 O NOTE System performance is optimized when the DIMM type and quantity are equal for both CPUs and when all channels are filled equally across the CPUs in the server 16 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Caveats m For optimum performance do not mix DIMMs with different frequencies If you mix DIMM frequencies the system defaults to the lower frequency m Do not mix RDIMMs and LRDIMMs m DIMMs for CPU 1 and CPU 2 when populated must always be configured identically m The server supports 1 or 2 DIMMs per channel for single or dual rank RDIMMs m The server supports 1 or 2 DIMMs per channel for quad rank LRDIMMs m The server supports registered DIMMs RDIMMs or load reduced DIMMS LRDIMMs however do not mix RDIMMs and LRDIMMs in a server m When using mirroring DIMMs must be installed in identical pairs across paired DDR3 buses That is mirrored pairs in channels A
49. lex LPe 12002 8Gb dual port Fibre Channel HBA 28 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Figure 5 Network Card Connections Network PCle Card Optical SFP Modules Fiber Optic Cables a Redundant Top of Rack Access Switches a agi Network PCle Card Twinax Copper Cables Redundant Top of Rack Access Switches Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 29 CONFIGURING the SERVER STEP 8 ORDER POWER SUPPLY The C220 M3 SFF server accommodates two power supplies A lightly loaded server can operate from one 650 W power supply A fully loaded server might need to be powered with two 450 W or two 650 W power supplies see Table 12 Use the power calculator at the following link to determine the needed power based on the options chosen CPUs drives memory and so on https express salire com Go Cisco Cisco UCS Power Calculator aspx Table 12 Power Supply PIDs Product ID PID PID Description UCSC PSU 450W 450 W power supply UCSC PSU 650W 650 W power supply NOTE In a two power supply server both power supplies must be identical 30 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 9 SELECT AC POWER CORD s Using Table 13 select the appropriate AC power cords You can select a mini
50. mm 29 2 in 741 mm 299 83 b 136 kg 354 Ib 161 kg Yes 42RU 2100 Ib 954 kg Not applicable Expansion Rack 78 74 x 23 58 x 43 38 In 2000 x 599 x 1102 mm 89 x 33 x 47 In 2261 x 838 x 1194 mm 29 2 in 741 mm 231 49 Ib 105 kg 284 Ib 129 kg No 42RU 2100 Ib 954 kg Not applicable O NOTE The AC input connector is an IEC 320 C 14 15 A 250 VAC power inlet 62 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL Figure 9 Cisco R42610 Rack Front view door closed Front view door open Front view door removed Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 63 SUPPLEMENTAL MATERIAL PDUs Cisco RP Series Power Distribution Units PDUs offer power distribution with branch circuit protection Cisco RP Series PDU models distribute power to up to 24 outlets The architecture organizes power distribution simplifies cable management and enables you to move add and change rack equipment without an electrician With a Cisco RP Series PDU in the rack you can replace up to two dozen input power cords with just one The fixed input cord connects to the power source from overhead or under floor distribution Your IT equipment is then powered by PDU outlets in the rack using short easy to manage power cords The C series severs accept the zero rack unit ORU PDU
51. mum of no power cords and a maximum of two If you select the option R2XX DMYMPWRCORD no power cord is shipped with the server Table 13 Available Power Cords Product ID PID PID Description Images R2XX DMYMPWRCORD No power cord dummy PID to Not applicable allow for a no power cord option CAB N5K6A NA Power Cord 200 240V 6A North America CAB AC L620 C13 AC Power Cord NEMA L6 20 C13 2M 6 5ft CAB C13 CBN CABASY WIRE UMPER CORD 27 L C13 C14 10A 250V E pa s SE Hos CAB C13 C14 2M CABASY WIRE J UMPER CORD PWR PO 2 Meter C13 C14 10A 250V 5 Ng ME CAB C13 C14 AC CORD PWR MP IEC60320 C14 IECH 0320 C13 3 0M Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 31 CONFIGURING the SERVER Table 13 Available Power Cords Product ID PID SFS 250V 10A AR CAB 9K10A AU SFS 250V 10A CN CAB 250V 10A CN CAB 9K10A EU SFS 250V 10A ID SFS 250V 10A IS 32 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model PID Description Power Cord SFS 250V 10A Argentina Power Cord 250VAC 10A 3112 Plug Australia Power Cord SFS 250V 10A China AC Power Cord 250V 10A PRC Power Cord 250VAC 10A CEE 7 7 Plug EU Power Cord SFS 250V 10A India Power Cord
52. nents that you want to include 10 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model STEP 2 SELECT CPU s The standard CPU features are m Intel E5 2600 series processor family CPUs m Intel C600 series chipset m Cache size of 10 15 or 20 MB Select CPUs The available CPUs are listed in Table 3 Table 3 Available Intel CPUs E5 2600 Series Processor Family CPUs CONFIGURING the SERVER Product ID PID UCS CPU E5 2690 UCS CPU E5 2680 UCS CPU E5 2670 UCS CPU E5 2667 UCS CPU E5 2665 UCS CPU E5 2660 UCS CPU E5 2650 UCS CPU E5 2650L UCS CPU E5 2643 UCS CPU E5 2640 UCS CPU E5 2630 UCS CPU E5 2630L UCS CPU E5 2620 UCS CPU E5 2609 Notes Intel Number E5 2690 E5 2680 E5 2670 E5 2667 E5 2665 E5 2660 E5 2650 E5 2650L E5 2643 E5 2640 E5 2630 E5 2630L E5 2620 E5 2609 Clock Freq GHz 2 90 2 10 2 60 2 90 2 40 2 20 2 00 1 80 3 30 2 50 2 30 2 00 2 00 2 40 Power W 135 130 115 130 115 95 95 10 130 95 95 60 95 80 Cache Size MB 20 20 20 15 20 20 20 20 10 15 15 15 15 10 Cores gt O O O O A O co O O 0 O OO OO QPI 8 GT s 8 GT s 8 GT s 8 GT s 8 GT s 8 GT s 8 GT s 8 GT s 8 GT s 7 2 GT s 7 2 GT s 7 2 GT s 7 2 GT s 6 4 GT s Highest DDR3 DIMM Clock Support MHz 1600 1600 1600 1600 1600 1600 1600 1600 1600 1333 1333 1333 1333 1066 1 If higher or lower speed DIMMs a
53. o UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 55 SUPPLEMENTAL MATERIAL RAID Summary The C220 M3 SFF server has an 8 drive backplane ROM5 and ROM55 embedded RAID upgrade options support up to 8 drives Mezzanine card UCSC RAID 11 C220 supports up to 8 drives Mezzanine card UCSC RAID MZ 220 supports up to 8 drives SAS 9266 81 and SAS 9266CV 8i PCle cards support up to 8 drives LSI MegaRAID SAS 9285CV 8e supports up to 8 external SAS ports 240 external drives NOTE If you do not select a mezzanine card a plug in PCle RAID card or one of the embedded RAID upgrade options you will have an embedded SATA only RAID NI controller that supports up to four SATA only drives RAID 0 1 10 See Table 32 for a summary of the supported RAID configuration options Table 33 Supported RAID Configurations Server C220 M3 SFF C220 M3 SFF C220 M3 SFF C220 M3 SFF C220 M3 SFF C220 M3 SFF C220 M3 SFF C220 M3 SFF C220 M3 SFF 56 Embedded Mezz Internal Internal External Drives PCle RAID PCle PCle 2 CPUs RAID RAID 13 RAID 24 RAIDS Supported Not Not maa el AE r EDD 1 Not Not Masa ba d Not d allowed allowed default allowed PCle Slots 8 internal 1 Not Not Installed O internal U moor allowed absent allowed in slot 1 external Not Not nG Not Installed Ga allowed allowed default allowed in slot2 Hino Not Not Not Not senit rar JC Ir
54. o UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES Copper twinax cables and SFP optical modules may be ordered to support the two port network cards that are available with the server Choose Optional Twinax Cables Table 10 lists the copper twinax cables available for the PCle cards You can choose cable lengths of 1 3 5 7 or 10 meters The two longer cables 7 and 10 meters are active which means that they contain active components within the SFP housing to improve signal quality Table 10 Available Twinax Cables Product ID PID PID Description SFP H10GB CU1M 10GBASE CU SFP Cable 1 M SFP H10GB CU3M 10GBASE CU SFP Cable 3 M SFP H10GB CU5M 10GBASE CU SFP Cable 5 M SFP H1O0GB ACU7M 10GBASE CU SFP Cable 7 M SFP H10GB ACU10M 10GBASE CU SFP Cable 10 M Approved Configurations 1 Choose Up to Two Twinax Cables for Each Network Card Ordered m You may choose one or two twinax cables for each network card ordered The cables can be different lengths however you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment Caveats The twinax cables listed in Table 10 can be ordered only for the following PCle cards UCS PCIE BSFP Broadcom 57712 N2XX AIPCI01 Intel Dual Port Ethernet X520 UCSC PCIE CSC 02 Cisco VIC 1225 Dual Port 1
55. ontrollers are not supported in this server 5 External RAID card is the 9285CV 8e The 9285C V e can be installed simultaneously with either one mezzanine RAID controller card or one internal RAID controller card 9266 81 or 9266CV 81 6 A available slot O occupied slot U unsupported slot slot 2 is not supported in 1 CPU systems 7 The mezzanine slot is not supported in 1 CPU systems Server Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 57 SUPPLEMENTAL MATERIAL The server contains an Option ROM OPROM for the PCle slots The server has a finite amount of option ROM with which it can boot up devices Go into the BIOS and disable the OPROM on the PCle slots not used for booting so that resources are available for the slots that are used for booting An example OPROM BIOS screen is shown in Figure 8 Figure 8 Example BIOS Screen for OPROM Aptio Setup Utility Copyright C 2012 American Megatrends Inc mj NG RA Advanced alEnable or Disable all PCIe 5lots oprom execution LOM Port O OptionRoH Enabled LOM Port 1 OptionRoM Enabled All PCIe Slots OptionROH Enabled m F me m7 J PA Aq Na 4 i r ro LL PETe 510t10 1 Opt ilonkoM LEnabled 51011D 2 OptionkoH Et at led 11 Enter 5 3 r 7 f ee na re J 4 SlotID M OptionROM Ena Lec Version 2 15 1226 Copyright C 2012 American Megatrends Inc 58 Cisco UCS Cisco UCS C220 M3 High Dens
56. pose USB socket and two SD sockets as shown in Figure 12 The mounting location for the RAID SuperCap data cache power backup module is also shown Figure 12 Motherboard USB and SD Ports and RAID Card Super Capacitor Location 8 8 8 a 6g 25 OO 35373 a of JT O a O j6 ee Q KO SO la OO ei So O ee Lul Q nba Se o OO Coi Q Ca Se O ee eo fa O Se Xe 0G Q Se SO ja SS Q je le la te O Oy a O O oQ OD SOS ome Q ene faa ORD 86 T gt Z mad O Xe Sc a Raj VUVUVUVUY Q Se SO ta OO PCle1 la a Se O a O O O O PO q Oy a O O O O O O O KISS 00000 E3 cj 3 Oss Oo j e3 63I Ew 90809 INGOO HOOD 00000 HOOD 0690 QO 0000 00000 HOOD OSBOO SEES WR FAN3 One PULO ko H LE B3 a BRL INGOO 0000 00000 KAO BED FAN4
57. power specifications for the C220 M3 server are listed in Table 39 Table 40 UCS C220 M3 Environmental Specifications Parameter Minimum Temperature operating 41 to 104 F 5 to 40 C derate the maximum temperature by 1 C per every 305m of altitude above sea level Temperature nonoperating 40 to 149 F 40 to 65 C Humidity RH nonoperating 10 to 90 non condensing Altitude operating 0 to 3 000 m 0 to 10 000 ft Altitude nonoperating 0 to 12 192 m 0 to 40 000 ft Sound Power level Measure 5 4 A weighted per 1507779 LWAd Bels Operation at 73 F 23 C Sound Pressure level Measure 37 A weighted per ISO7779 LpAm dBA Operation at 73 F 23 C Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 69 TECHNICAL SPECIFICATIONS Compliance Requirements The regulatory compliance requirements for C Series servers are listed in Table 40 Table 41 UCS C Series Regulatory Compliance Requirements Parameter Description Regulatory Compliance Products should comply with CE Markings per directives 2004 108 EC and 2006 95 EC Safety UL 60950 1 Second Edition CAN CSA C22 2 No 60950 1 Second Edition EN 60950 1 Second Edition IEC 60950 1 Second Edition AS NZS 60950 1 GB4943 2001 EMC Emissions 47CFR Part 15 CFR 47 Class A AS NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000 3 2 EN61000 3 3 KN22 Class A CN
58. r CIMC firmware m Various PCle card ports dependent on which cards are installed e Converged Network Adapter CNA ports e Network Interface Card NIC ports e Host Bus Adapter HBA ports m Front panel e One KVM console connector supplies two USB one VGA and one serial connector Front Panel A front panel controller provides status indications and control buttons Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 7 BASE SERVER STANDARD CAPABILITIES and FEATURES Capability Feature Description Power subsystem Up to two 450 W 650 W power supplies One is mandatory one more can be added for 1 1 redundancy Fans Chassis m Five hot swappable fans for front to rear cooling Power supply m Each power supply is equipped with a fan Integrated management Cisco Integrated Management Controller CIMC firmware pooner Depending on your CIMC settings the CIMC can be accessed through the 1 Gb Ethernet dedicated management port the 1 Gb Ethernet LOM ports or a Cisco 1225 virtual interface card VIC 8 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS C220 M3 High Density SFF Rack Server STEP 1 VERIFY SERVER SKU page 10 STEP 2 SELECT CPU s page 11 STEP 3 SELECT MEMORY page 13 STEP 4 SELECT RAID CONFIGURATION page 18 STEP 5
59. r CPU up to 2 DIMMs per channel Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 13 CONFIGURING the SERVER Select DIMMs and Memory Mirroring Select the memory configuration and whether or not you want the memory mirroring option The available memory DIMMs and mirroring option are listed in Table 4 NOTE When memory mirroring is enabled the memory subsystem simultaneously writes identical data to two channels If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error the system automatically retrieves the data from the other channel A transient or soft error in one channel does not affect the mirrored data and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM Memory mirroring reduces the amount of memory available to the operating system by 50Y6because only one of the two populated channels provides data Q Table 4 Available DDR3 DIMMs Product ID PID PID Description Voltage Papa DIMM Options UCS ML 1X324RY A 32GB DDR3 1600 MHz LR DIMM PC3 12800 quad rank x4 1 35v 135V 4 UCS MR 1X162RY A 16GB DDR3 1600 MHz RDIMM PC3 12800 dual rank x4 1 35v 135V 2 UCS MR 1X082RY A 8GB DDR3 1600 MHz RDIMM PC3 12800 dual rank x4 1 35v 135V 2 UCS MR 1X082RX A 8GB DDR3 1333 MHz RDIMM PC3 10600 dual rank x4 1 35v 135V 2 UCS MR 1X041RY A 4GB DDR3 1600 MHz RDIMM PC3 1280
60. re selected than what is shown in the table for a given CPU the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 11 CONFIGURING the SERVER Approved Configurations 1 1 CPU configurations m Select any one CPU listed in Table 3 2 2 CPU Configurations m Select two identical CPUs from any one of the rows of Table 3 on page 11 Caveats m You can select either one processor or two identical processors m For optimal performance select DIMMs with the highest clock speed for a given processor see Table 3 on page 11 If you select DIMMs whose speeds are lower or higher than that shown in the tables suboptimal performance will result 12 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 3 SELECT MEMORY The standard memory features are m DIMMs Clock speed 1333 or 1600 MHz Ranks per DIMM 1 2 or 4 Operational voltage dual voltage capable 1 5 V or 1 35 V Registered or unbuffered ECC DDR3 DIMMs RDIMMs or UDIMMs or load reduced DIMMs LRDIMMs m Memory is organized with four memory channels per CPU with up to two DIMMs per channel as shown in Figure 4 Figure 4 C220 M3 SFF Memory Organization Bank 2 Bank 1 Bank 1 CPU 1 sn CPU2 f 16 DIMMS 512 GB maximum memory 4 memory channels pe
61. sco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 47 OPTIONAL STEP ORDER PDU OPTIONAL STEP ORDER PDU An optional power distribution unit PDU is available from Cisco for the C Series rack servers including theC220 M3 server This PDU is available in a zero rack unit RU style see Table 27 Table 29 PDU Options Product ID PID PID Description RP208 30 2P U 2 Zero RU PDU For more information about the PDU see PDUs page 64 48 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL CHASSIS An internal view of the C220 M3 chassis with the top cover removed is shown in Figure 6 Figure 6 C220 M3 SFF With Top Cover Off 25 5 O O 8 85 O o O Ca O O O O ey Xe 0 O SO BO te 05 O O O O 120 a Xe Xe O O O 0 BO 225 ene 959 HPN Q 83 ei OF Ss Q 28 o O ES O Ka O QO QO O O O O a O O SO Be Xs es O KO NG a Rs Q Xe ta Xe G ay O O O O SO te 06 O O O o 2A Ka Xe Xa O O O O Q Da 2 BO Ka 03 je ei 130 Q fes Fe ea Ko O 88
62. ted in Table 22 Table 23 SMART net for UCS Hardware Only Service Service On LOPE Product ID PID Level GSP Site Description CON UCW7 C220M3SF UCW7 Yes UCS HW 24X7X40S UCS C220 M3 SFF CON UCW5 C220M3SF UCW5 Yes UC PLUS 8X5XNBDOS UCS C220 M3 SFF Unified Computing Partner Support Service Cisco Partner Support Service PSS is a Cisco Collaborative Services service offering that is designed for partners to deliver their own branded support and managed services to enterprise customers Cisco PSS provides partners with access to Cisco s support infrastructure and assets to help them m Expand their service portfolios to support the most complex network environments m Lower delivery costs m Deliver services that increase customer loyalty Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high value technical support that capitalizes on Cisco intellectual assets This helps partners to realize higher margins and expand their practice PSS is available to all Cisco PSS partners but requires additional specializations and requirements For additional information see the following URL www cisco com go partnerucssupport The two Partner Unified Computing Support Options include m Partner Support Service for UCS m Partner Support Service for UCS Hardware Only Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 43 CONFIGURING the SERVE
63. voltage Main power 12 VDC Standby power 12 VDC Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model 67 TECHNICAL SPECIFICATIONS Table 38 UCS C220 M3 SFF 450 W Power Supply Specifications Description Specification Power supply efficiency CSCI Platinum NOTE AC input connector is an IEC 320 C 14 15A 250VAC power inlet The general power specifications for the C220 M3 SFF server 650 W power supply are listed in Table 37 Table 39 UCS C220 M3 SFF 650 W Power Supply Specifications Description Specification AC input voltage AC input frequency Maximum AC input current Maximum AC inrush current Maximum output power for the power supply Power supply output voltage Power supply efficiency 90 to 264 VAC self ranging 100 to 120 VAC nominal 200 to 240 VAC nominal Range 47 to 63 Hz single phase 50 to 60 Hz nominal 7 6 A peak at 100 VAC 3 65 A peak at 208 VAC 11A 650 W Main power 12 VDC Standby power 12 VDC CSCI Platinum Q NOTE AC input connector is an IEC 320 C 14 15A 250VAC power inlet For configuration specific power specifications use the Cisco UCS Power Calculator at this URL https express salire com Go Cisco Cisco UCS Power Calculator aspx 68 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model TECHNICAL SPECIFICATIONS Environmental Specifications The
64. ze the uptime performance and efficiency of your UCS m Protect your vital business applications by rapidly identifying and addressing issues m Strengthen in house expertise through knowledge transfer and mentoring B Improve operational efficiency by allowing UCS experts to augment your internal staff resources Enhance business agility by diagnosing potential issues before they affect your operations 44 Cisco UCS Cisco UCS C220 M3 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER You can choose a service listed in Table 25 Table 26 UCS Computing Combined Support Service Product ID PID eee ie Description CON NCF2 C220M3SF NCF2 No CMB SPT SVC 24X7X2 UCS C220 M3 SFF CON NCF2P C220M3SF NCF2P Yes CMB SPT SVC 24X7X20S UCS C220 M3 SFF CON NCF4P C220M3SF NCF4P Yes CMB SPT SVC 24X7X40S UCS C220 M3 SFF CON NCF4S C220M3SF NCF4S Yes CMB SPT SVC 8X5X40S UCS C220 M3 SFF CON NCFCS C220M3SF NCFCS Yes CMB SPT SVC 8X5XNBDOS UCS C220 M3 SFF CON NCFE C220M3SF NCFE No CMB SPT SVC 8X5X4 UCS C220 M3 SFF CON NCFP C220M3SF NCFP NO CMB SPT SVC 24X7X4 UCS C220 M3 SFF CON NCFT C220M3SF NCFT No CMB SPT SVC 8X5XNBD UCS C220 M3 SFF Unified Computing Drive Retention Service With the Cisco Unified Computing Drive Retention UCDR Service you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive In exchange for a Cisco replacement drive you provide a signed Certificate
65. zzanine RAID controller and one external RAID controller or One internal RAID controller or One internal RAID controller and one external RAID controller Q NOTE For all valid combinations of embedded RAID mezzanine RAID and internal external RAID controller combinations see RAID Summary page 56 Table 5 Available Embedded RAID Options Product ID PID RAID Controllers UCSC RAID ROM5 UCSC RAID ROM55 PID Description Onboard RAID supporting up to 8 SAS SATA drives This option supports RAID 0 1 and 10 and operates at 3 Gb s Operating systems supported are Windows and Linux only no VMware support Onboard RAID supporting up to 8 SAS SATA drives This option supports RAID 0 1 5 and 10 and operates at 3 Gb s Operating systems supported are Windows and Linux only no VMware support Table 6 Available Mezzanine Card RAID Options Product ID PID PID Description Mezzanine RAID Controllers not supported in 1 CPU systems UCSC RAID 11 C220 UCSC RAID MZ 220 Cisco UCSC RAID SAS 2008M 8i Mezzanine Card RAID O 1 5 10 and 50 supported operating at 6 Gbs m Supports up to eight internal SAS SATA drives SAS and SATA drives can be mixed m Factory configured RAID options available RAID O 1 5 and 10 see the RAID PIDs section in this table Cisco UCSC RAID SAS 2008M 8i Mezzanine Card RAID 0 1 10 supported operating at 6 Gbs m Supports up to eight internal SAS SATA drives S
Download Pdf Manuals
Related Search
Related Contents
PowerLogic PM8000 user manual Kolcraft W025-R2 User's Manual Peerless ACC314-AB mounting kit PA 4080 KB keyboard combo user manual operation instructions mode d´emploi manual de instrucciones ministère de I`Ecoiogie du Développement et de I LS5105 Document No 2 [PDF 1MB] - Australian Electoral Commission ~ -ティ ジ撃ル ・ プログラマフ・ル Link Gate PRI Copyright © All rights reserved.